Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
Neurosurg Rev ; 47(1): 374, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39083214

RESUMO

The Woven EndoBridge (WEB) device is primarily used for treating wide-neck intracranial bifurcation aneurysms under 10 mm. Limited data exists on its efficacy for large aneurysms. We aim to assess angiographic and clinical outcomes of the WEB device in treating large versus small aneurysms. We conducted a retrospective review of the WorldWide WEB Consortium database, from 2011 to 2022, across 30 academic institutions globally. Propensity score matching (PSM) was employed to compare small and large aneurysms on baseline characteristics. A total of 898 patients were included. There was no significant difference observed in clinical presentations, smoking status, pretreatment mRS, presence of multiple aneurysms, bifurcation location, or prior treatment between the two groups. After PSM, 302 matched pairs showed significantly lower last follow-up adequate occlusion rates (81% vs 90%, p = 0.006) and higher retreatment rates (12% vs 3.6%, p < 0.001) in the large aneurysm group. These findings may inform treatment decisions and patient counseling. Future studies are needed to further explore this area.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Pontuação de Propensão , Humanos , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Adulto , Embolização Terapêutica/métodos
2.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483647

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/etiologia , Embolização Terapêutica/efeitos adversos , Pontuação de Propensão , Estudos Retrospectivos , Estudos de Coortes , Procedimentos Endovasculares/efeitos adversos
3.
J Stroke Cerebrovasc Dis ; 33(11): 107897, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39069148

RESUMO

INTRODUCTION: The Woven EndoBridge (WEB) device is emerging as a novel therapy for intracranial aneurysms, but its use for off-label indications requires further study. Using machine learning, we aimed to develop predictive models for complete occlusion after off-label WEB treatment and to identify factors associated with occlusion outcomes. METHODS: This multicenter, retrospective study included 162 patients who underwent off-label WEB treatment for intracranial aneurysms. Baseline, morphological, and procedural variables were utilized to develop machine-learning models predicting complete occlusion. Model interpretation was performed to determine significant predictors. Ordinal regression was also performed with occlusion status as an ordinal outcome from better (Raymond Roy Occlusion Classification [RROC] grade 1) to worse (RROC grade 3) status. Odds ratios (OR) with 95 % confidence intervals (CI) were reported. RESULTS: The best performing model achieved an AUROC of 0.8 for predicting complete occlusion. Larger neck diameter and daughter sac were significant independent predictors of incomplete occlusion. On multivariable ordinal regression, higher RROC grades (OR 1.86, 95 % CI 1.25-2.82), larger neck diameter (OR 1.69, 95 % CI 1.09-2.65), and presence of daughter sacs (OR 2.26, 95 % CI 0.99-5.15) were associated with worse aneurysm occlusion after WEB treatment, independent of other factors. CONCLUSION: This study found that larger neck diameter and daughter sacs were associated with worse occlusion after WEB therapy for aneurysms. The machine learning approach identified anatomical factors related to occlusion outcomes that may help guide patient selection and monitoring with this technology. Further validation is needed.

4.
Radiology ; 304(2): 372-382, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35438564

RESUMO

Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the treatment of sidewall aneurysms, with promising outcomes. Purpose To compare the angiographic and clinical outcomes of the WEB device for the treatment of sidewall aneurysms compared with the treatment of bifurcation aneurysms. Materials and Methods A retrospective review of the WorldWideWEB Consortium, a synthesis of retrospective databases spanning from January 2011 to June 2021 at 22 academic institutions in North America, South America, and Europe, was performed to identify patients with intracranial aneurysms treated with the WEB device. Characteristics and outcomes were compared between bifurcation and sidewall aneurysms. Propensity score matching (PSM) was used to match by age, pretreatment ordinal modified Rankin Scale score, ruptured aneurysms, location of aneurysm, multiple aneurysms, prior treatment, neck, height, dome width, daughter sac, and incorporated branch. Results A total of 683 intracranial aneurysms were treated using the WEB device in 671 patients (median age, 61 years [IQR, 53-68 years]; male-to-female ratio, 1:2.5). Of those, 572 were bifurcation aneurysms and 111 were sidewall aneurysms. PSM was performed, resulting in 91 bifurcation and sidewall aneurysms pairs. No significant difference was observed in occlusion status at last follow-up, deployment success, or complication rates between the two groups. Conclusion No significantly different outcomes were observed following the off-label use of the Woven EndoBridge, or WEB, device for treatment of sidewall aneurysms compared with bifurcation aneurysms. The correct characterization of the sidewall aneurysm location, neck angle, and size is crucial for successful treatment and lower retreatment rate. © RSNA, 2022 See also the editorial by Hetts in this issue.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Aneurisma Roto/terapia , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
5.
Neurosurg Rev ; 43(4): 1173-1178, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31332702

RESUMO

Loss of consciousness (LOC) at presentation with aneurysmal subarachnoid hemorrhage (aSAH) has been associated with early brain injury and poor functional outcome. The impact of LOC on the clinical course after aSAH deserves further exploration. A retrospective analysis of 149 aSAH patients who were prospectively enrolled in the Cerebral Aneurysm Renin Angiotensin Study (CARAS) between 2012 and 2015 was performed. The impact of LOC was analyzed with emphasis on patients presenting in excellent or good neurological condition (Hunt and Hess 1 and 2). A total of 50/149 aSAH patients (33.6%) experienced LOC at presentation. Loss of consciousness was associated with severity of neurological condition upon admission (Hunt and Hess, World Federation of Neurosurgical Societies (WFNS), Glasgow Coma Scale (GCS) grade), hemorrhage burden on initial head CT (Fisher CT grade), acute hydrocephalus, cardiac instability, and nosocomial infection. Of Hunt and Hess grade 1 and 2 patients, 21/84 (25.0%) suffered LOC at presentation. Cardiac instability and nosocomial infection were significantly more frequent in these patients. In multivariable analysis, LOC was the predominant predictor of cardiac instability and nosocomial infection. Loss of consciousness at presentation with aSAH is associated with an increased rate of complications, even in good-grade patients. The presence of LOC may identify good-grade patients at risk for complications such as cardiac instability and nosocomial infection.


Assuntos
Hemorragia Subaracnóidea/complicações , Inconsciência/etiologia , Adulto , Idoso , Estudos de Coortes , Infecção Hospitalar/complicações , Infecção Hospitalar/epidemiologia , Feminino , Seguimentos , Escala de Coma de Glasgow , Cardiopatias/complicações , Cardiopatias/epidemiologia , Humanos , Hidrocefalia/complicações , Hidrocefalia/epidemiologia , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/etiologia , Hemorragia Subaracnóidea/epidemiologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Inconsciência/epidemiologia
6.
Stroke ; 48(5): 1322-1330, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28411263

RESUMO

BACKGROUND AND PURPOSE: Thromboembolic complications constitute a significant source of morbidity after neurointerventional procedures. Flow diversion using the pipeline embolization device for the treatment of intracranial aneurysms necessitates the use of dual antiplatelet therapy to reduce this risk. The use of platelet function testing before pipeline embolization device placement remains controversial. METHODS: A retrospective review of prospectively maintained databases at 3 academic institutions was performed from the years 2009 to 2016 to identify patients with intracranial aneurysms treated with pipeline embolization device placement. Clinical and radiographic data were analyzed with emphasis on thromboembolic complications and clopidogrel responsiveness. RESULTS: A total of 402 patients underwent 414 pipeline embolization device procedures for the treatment of 465 intracranial aneurysms. Thromboembolic complications were encountered in 9.2% of procedures and were symptomatic in 5.6%. Clopidogrel nonresponders experienced a significantly higher rate of thromboembolic complications compared with clopidogrel responders (17.4% versus 5.6%). This risk was significantly lower in nonresponders who were switched to ticagrelor when compared with patients who remained on clopidogrel (2.7% versus 24.4%). In patients who remained on clopidogrel, the rate of thromboembolic complications was significantly lower in those who received a clopidogrel boost within 24 hours pre-procedure when compared with those who did not (9.8% versus 51.9%). There was no significant difference in the rate of hemorrhagic complications between groups. CONCLUSIONS: Clopidogrel nonresponders experienced a significantly higher rate of thromboembolic complications when compared with clopidogrel responders. However, this risk seems to be mitigated in nonresponders who were switched to ticagrelor or received a clopidogrel boost within 24 hours pre-procedure.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Embolia Intracraniana/prevenção & controle , Trombose Intracraniana/prevenção & controle , Avaliação de Resultados em Cuidados de Saúde , Inibidores da Agregação Plaquetária/farmacologia , Testes de Função Plaquetária , Ticlopidina/análogos & derivados , Adenosina/administração & dosagem , Adenosina/análogos & derivados , Adenosina/farmacologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Clopidogrel , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Embolia Intracraniana/etiologia , Trombose Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/farmacologia , Estudos Retrospectivos , Ticagrelor , Ticlopidina/administração & dosagem , Ticlopidina/farmacologia , Adulto Jovem
7.
Stroke ; 48(4): 1098-1100, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28246277

RESUMO

BACKGROUND AND PURPOSE: Intraprocedural thrombosis poses a formidable challenge during neuroendovascular procedures because the risks of aggressive thromboembolic treatment must be balanced against the risk of postprocedural hemorrhage. The aim of this study was to identify predictors of ischemic stroke after intraprocedural thrombosis after stent-assisted coiling and pipeline embolization device placement. METHODS: A retrospective analysis of intracranial aneurysms treated with stent-assisted coiling or pipeline embolization device placement between 2007 and 2016 at 4 major academic institutions was performed to identify procedures that were complicated by intraprocedural thrombosis. RESULTS: Intraprocedural thrombosis occurred in 34 (4.6%) procedures. Postprocedural ischemic stroke and hemorrhage occurred in 20.6% (7/34) and 11.8% (4/34) of procedures complicated by intraprocedural thrombosis, respectively. Current smoking was an independent predictor of ischemic stroke. There was no statistically significant difference in the rate of ischemic stroke or postprocedural hemorrhage with the use of abciximab compared with the use of eptifibatide in treatment of intraprocedural thrombosis. CONCLUSIONS: Current protocols for treatment of intraprocedural thrombosis associated with placement of intra-arterial devices were effective in preventing ischemic stroke in ≈80% of cases. Current smoking was the only independent predictor of ischemic stroke.


Assuntos
Isquemia Encefálica/etiologia , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Fármacos Hematológicos/uso terapêutico , Aneurisma Intracraniano/terapia , Trombose Intracraniana , Complicações Intraoperatórias , Trombólise Mecânica/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Stents , Acidente Vascular Cerebral/etiologia , Angiografia Digital , Anticoagulantes/uso terapêutico , Isquemia Encefálica/epidemiologia , Embolização Terapêutica/estatística & dados numéricos , Procedimentos Endovasculares/estatística & dados numéricos , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Aneurisma Intracraniano/epidemiologia , Trombose Intracraniana/complicações , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/epidemiologia , Trombose Intracraniana/terapia , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/terapia , Masculino , Trombólise Mecânica/estatística & dados numéricos , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia
8.
Stroke ; 53(2): e47-e49, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34915737
9.
Nitric Oxide ; 71: 52-56, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29079038

RESUMO

INTRODUCTION: Cardiac abnormalities are observed frequently after aneurysmal subarachnoid hemorrhage (aSAH). A subset of aSAH patients develops neurogenic cardiomyopathy, likely induced by catecholamine excess. Genetic polymorphisms of the endothelial nitric oxide synthase (eNOS) gene have been linked to decreased nitric oxide (NO) levels, coronary artery spasm, and myocardial infarction. The role of the eNOS single nucleotide polymorphism (SNP) -786 T/C in cardiac instability following aSAH has not been previously investigated. METHODS: From 2012 to 2015, aSAH patients were prospectively enrolled in the Cerebral Aneurysm Renin Angiotensin System (CARAS) study at two academic institutions. Blood samples were used to assess the eNOS SNP -786 T/C rs2070744 through 5'exonuclease (Taqman) genotyping assays. Associations between this polymorphism and cardiac instability following aSAH were analyzed. RESULTS: Multivariable analysis demonstrated a dominant effect of the C allele of eNOS SNP -786 T/C on cardiac instability in patients with aSAH. A lower Glasgow Coma Scale score and a history of ischemic vascular disease were also associated with cardiac instability. Furthermore, cardiac instability independently predicted poor functional outcome upon discharge from the hospital. CONCLUSIONS: The C allele of the eNOS SNP -786 T/C was independently associated with an increased risk for cardiac instability following aSAH. Cardiac instability itself was a risk factor for an unfavorable functional outcome upon discharge from the hospital.


Assuntos
Cardiopatias/etiologia , Cardiopatias/genética , Óxido Nítrico Sintase Tipo III/genética , Polimorfismo Genético/genética , Hemorragia Subaracnóidea/complicações , Adulto , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/genética , Feminino , Humanos , Hipotensão/etiologia , Hipotensão/genética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/genética
10.
Acta Neurochir (Wien) ; 158(1): 189-95, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26589958

RESUMO

BACKGROUND: Intracranial hemorrhage (ICH) has been reported in association with sexual activity. A case-series of patients with ICH following sexual activity is presented to further elucidate the role of the physiologic sexual response as a trigger of ICH. METHOD: A retrospective review of the medical record was performed, identifying patients presenting with ICH temporally related to sexual activity. Clinical and radiographic data were collected and reported. RESULTS: Sixteen patients presented with non-traumatic ICH temporally related to sexual activity. Eight (50 %) patients presented with aneurysmal subarachnoid hemorrhage, four (25 %) with angiogram-negative subarachnoid hemorrhage, two (12.5 %) with a ruptured arteriovenous malformation, and two (12.5 %) with an intracerebral basal ganglia hemorrhage. Overall average age was 49.9 (range, 28-74) years. Sexual activity involved male-female intercourse in 14 (87.5 %) patients and masturbation in 2 (12.5 %) patients. CONCLUSIONS: Sexual-activity-related ICH is rare and includes various etiologies. The human sexual response in associated with dramatic increases in arterial blood pressure, which likely underlies the association.


Assuntos
Hemorragias Intracranianas/etiologia , Comportamento Sexual , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Br J Neurosurg ; 29(6): 865-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26312946

RESUMO

Carotid endarterectomy (CEA) is a common and efficacious surgical procedure for the prevention of ischemic stroke due to atherosclerosis of the internal carotid artery (ICA). A high common carotid artery bifurcation can make CEA technically difficult due to limited carotid artery exposure. A cadaveric study was performed to evaluate the efficacy of nasotracheal intubation for improving access to a high carotid artery bifurcation. Based on this study, nasotracheal intubation does not improve access to a high carotid artery bifurcation as compared with orotracheal intubation.


Assuntos
Artérias Carótidas/patologia , Artérias Carótidas/cirurgia , Endarterectomia das Carótidas/métodos , Intubação Intratraqueal/métodos , Aterosclerose/complicações , Aterosclerose/patologia , Isquemia Encefálica/patologia , Isquemia Encefálica/cirurgia , Cadáver , Artéria Carótida Interna/cirurgia , Estenose das Carótidas , Humanos , Acidente Vascular Cerebral/patologia , Acidente Vascular Cerebral/cirurgia
12.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862717

RESUMO

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Stents
13.
Interv Neuroradiol ; : 15910199241267320, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39127463

RESUMO

BACKGROUND: Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond-Roy classification 1 or 2) remains challenging. OBJECTIVE: Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. METHODS: We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. RESULTS: A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535-0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024-0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer-Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/. CONCLUSION: The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.

14.
AJNR Am J Neuroradiol ; 45(7): 906-911, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977286

RESUMO

BACKGROUND AND PURPOSE: Despite the numerous studies evaluating the occlusion rates of aneurysms following WEB embolization, there are limited studies identifying predictors of occlusion. Our purpose was to identify predictors of aneurysm occlusion and the need for retreatment. MATERIALS AND METHODS: This is a review of a prospectively maintained database across 30 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB who had available intraprocedural data and long-term follow-up. RESULTS: We studied 763 patients with a mean age of 59.9 (SD, 11.7) years. Complete aneurysm occlusion was observed in 212/726 (29.2%) cases, and contrast stasis was observed in 485/537 (90.3%) of nonoccluded aneurysms. At the final follow-up, complete occlusion was achieved in 497/763 (65.1%) patients, and retreatment was required for 56/763 (7.3%) patients. On multivariable analysis, history of smoking, maximal aneurysm diameter, and the presence of an aneurysm wall branch were negative predictors of complete occlusion (OR, 0.5, 0.8, and 0.4, respectively). Maximal aneurysm diameter, the presence of an aneurysm wall branch, posterior circulation location, and male sex increase the chances of retreatment (OR, 1.2, 3.8, 3.0, and 2.3 respectively). Intraprocedural occlusion resulted in a 3-fold increase in the long-term occlusion rate and a 5-fold decrease in the retreatment rate (P < .001), offering a specificity of 87% and a positive predictive value of 85% for long-term occlusion. CONCLUSIONS: Intraprocedural occlusion can be used to predict the chance of long-term aneurysm occlusion and the need for retreatment after embolization with a WEB device. Smoking, aneurysm size, and the presence of an aneurysm wall branch are associated with decreased chances of successful treatment.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Estudos Retrospectivos , Resultado do Tratamento , Idoso , Fatores de Risco
15.
J Neurointerv Surg ; 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238006

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS: This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS: Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS: Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.

16.
J Neurosurg ; : 1-8, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701528

RESUMO

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

17.
J Neurointerv Surg ; 15(6): 558-565, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35483912

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device has Food and Drug Administration approval for treatment of wide-necked intracranial bifurcation aneurysms. The WEB device has been shown to result in adequate occlusion in bifurcation aneurysms overall, but its usefulness in the individual bifurcation locations has been evaluated separately only in few case series, which were limited by small sample sizes. OBJECTIVE: To compare angiographic and clinical outcomes after treatment of bifurcation aneurysms at various locations, including anterior communicating artery (AComA), anterior cerebral artery (ACA) bifurcation distal to AComA, basilar tip, internal carotid artery (ICA) bifurcation, and middle cerebral artery (MCA) bifurcation aneurysms using the WEB device. METHODS: A retrospective cohort analysis was conducted at 22 academic institutions worldwide to compare treatment outcomes of patients with intracranial bifurcation aneurysms using the WEB device. Data include patient and aneurysm characteristics, procedural details, angiographic and functional outcomes, and complications. RESULTS: A total of 572 aneurysms were included. MCA (36%), AComA (35.7%), and basilar tip (18.9%) aneurysms were most common. The rate of adequate aneurysm occlusion was significantly higher for basilar tip (91.6%) and ICA bifurcation (96.7%) aneurysms and lower for ACA bifurcation (71.4%) and AComA (80.6%) aneurysms (p=0.04). CONCLUSION: To our knowledge, this is the most extensive study to date that compares the treatment of different intracranial bifurcation aneurysms using the WEB device. Basilar tip and ICA bifurcation aneurysms showed significantly higher rates of aneurysm occlusion than other locations.


Assuntos
Doenças das Artérias Carótidas , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Doenças das Artérias Carótidas/terapia
18.
Transl Stroke Res ; 14(4): 455-464, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36066701

RESUMO

Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011-2015 (N = 66), 2016-2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020-2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
19.
J Neurointerv Surg ; 15(9): 844-850, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35868856

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. METHODS: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. RESULTS: The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. CONCLUSION: There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Embolização Terapêutica/métodos
20.
Transl Stroke Res ; 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37165289

RESUMO

The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa