Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
Eur J Clin Invest ; : e14292, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39058274

RESUMO

BACKGROUND: Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) are new anti-hyperglycaemic drugs with proven cardiovascular (CV) benefit in diabetic and non-diabetic patients at high CV risk. Despite a neutral class effect on arrhythmia risk, data on semaglutide suggest a possible drug-specific benefit in reducing atrial fibrillation (AF) occurrence. OBJECTIVE: To perform a meta-analysis of randomized clinical trials (RCTs) to assess the risk of incident AF in patients treated with semaglutide compared to placebo. METHODS AND RESULTS: Ten RCTs were included in the analysis. Study population encompassed 12,651 patients (7285 in semaglutide and 5366 in placebo arms), with median follow-up of 68 months. A random effect meta-analytic model was adopted to pool relative risk (RR) of incident AF. Semaglutide reduces the risk of AF by 42% (RR .58, 95% CI .40-.85), with low heterogeneity across the studies (I2 0%). At subgroup analysis, no differences emerged between oral and subcutaneous administration (oral: RR .53, 95% CI .23-1.24, I2 0%; subcutaneous: RR .59, 95% CI .39-.91, I2 0%; p-value .83). In addition, meta-regression analyses did not show any potential influence of baseline study covariates, in particular the proportion of diabetic patients (p-value .14) and body mass index (BMI) (p-value .60). CONCLUSIONS: Semaglutide significantly reduces the occurrence of incident AF by 42% as compared to placebo in individuals at high CV risk, mainly affected by type 2 diabetes mellitus. This effect appears to be consistent independently of the route of administration of the drug (oral or subcutaneous), the presence of underlying diabetes and BMI.

2.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38375690

RESUMO

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) detects myocardial scarring, a risk factor for ventricular arrhythmias (VAs) in hypertrophic cardiomyopathy (HCM). The LGE-CMR distinguishes core, borderzone (BZ) fibrosis, and BZ channels, crucial components of re-entry circuits. We studied how scar architecture affects inducibility and electrophysiological traits of VA in HCM. METHODS AND RESULTS: We correlated scar composition with programmed ventricular stimulation-inducible VA features using LGE intensity maps. Thirty consecutive patients were enrolled. Thirteen (43%) were non-inducible, 6 (20%) had inducible non-sustained, and 11 (37%) had inducible sustained mono (MMVT)- or polymorphic VT/VF (PVT/VF). Of 17 induced VA, 13 (76%) were MMVT that either ended spontaneously, persisted as sustained monomorphic, or degenerated into PVT/VF. Twenty-seven patients (90%) had LGE. Of these, 17 (57%) had non-sustained or sustained inducible VA. Scar mass significantly increased (P = 0.002) from non-inducible to inducible non-sustained and sustained VA patients in both the BZ and core components. Borderzone channels were found in 23%, 67%, and 91% of non-inducible, inducible non-sustained, and inducible sustained VA patients (P = 0.003). All 13 patients induced with MMVT or monomorphic-initiated PVT/VF had LGE. The origin of 10/13 of these VTs matched scar location, with 8/10 of these LGE regions showing BZ channels. During follow-up (20 months, interquartile range: 7-37), one patient with BZ channels and inducible PVT had an ICD shock for VF. CONCLUSION: Scar architecture determines inducibility and electrophysiological traits of VA in HCM. Larger studies should explore the role of complex LGE patterns in refining risk assessment in HCM patients.


Assuntos
Cardiomiopatia Hipertrófica , Canal de Sódio Disparado por Voltagem NAV1.5/deficiência , Taquicardia Ventricular , Fibrilação Ventricular , Humanos , Cicatriz/complicações , Cicatriz/patologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Meios de Contraste , Gadolínio/farmacologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações
3.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38652090

RESUMO

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração , Tomografia Computadorizada Multidetectores , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Idoso , Átrios do Coração/cirurgia , Átrios do Coração/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Recidiva , Frequência Cardíaca , Potenciais de Ação
4.
J Cardiovasc Electrophysiol ; 34(3): 598-606, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640425

RESUMO

INTRODUCTION: Despite numerous ECG algorithms being developed to localize the site of manifest accessory pathways (AP), they often require stepwise multiple-lead analysis with variable accuracy, limitations, and reproducibility. The study aimed to develop a single-lead ECG algorithm incorporating the P-Delta interval (PDI) as an adjunct criterion to discriminate between right and left manifest AP. METHODS: Consecutive WPW patients undergoing electrophysiological study (EPS) were retrospectively recruited and split into a derivation and validation group (1:1 ratio). Sinus rhythm ECG analysis in lead V1 was performed by three independent investigators blinded to the EPS results. Conventional ECG parameters and PDI were assessed through the global cohort. RESULTS: A total of 140 WPW patients were included (70 for each group). A score-based, single-lead ECG algorithm was developed through derivation analysis incorporating the PDI, R/S ratio, and QRS onset polarity in lead V1. The validation group analysis confirmed the proposed algorithm's high accuracy (95%), which was superior to the previous ones in predicting the AP side (p < 0.05). A score of ≤+1 was 96.5% accurate in predicting right AP while a score of ≥+2 was 92.5% accurate in predicting left AP. The new algorithm maintained optimal performance in specific subgroups of the global cohort showing an accuracy rate of 90%, 92%, and 96% in minimal pre-excitation, posteroseptal AP, and pediatric patients, respectively. CONCLUSIONS: A novel single-lead ECG algorithm incorporating the PDI interval with previous conventional criteria showed high accuracy in differentiating right from left manifest AP comprising pediatric and minimal pre-excitation subgroups in the current study.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Criança , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Algoritmos , Síndrome de Wolff-Parkinson-White/cirurgia
5.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36935638

RESUMO

AIMS: Insertable cardiac monitors (ICMs) are indicated for long-term monitoring of unexplained syncope or palpitations, and for detection of bradycardia, ventricular tachycardia, and/or atrial fibrillation (AF). The aim of our study was to evaluate the safety and clinical value associated with a new generation ICM (Confirm Rx™, Abbott, Illinois, USA), featuring a new remote monitoring system based on smartphone patient applications. METHODS AND RESULTS: The SMART Registry is an international prospective observational study. The main endpoints were ICM safety (incidence of serious adverse device and procedure-related events (SADEs) at 1 month), ICM clinical value (incidence of device-detected true arrhythmias and of clinical diagnoses and interventions), and patient-reported experience measurements (PREMs). A total of 1400 subjects were enrolled. ICM indications included syncope (49.1%), AF (18.8%), unexplained palpitations (13.6%), risk of ventricular arrhythmia (6.6%), and cryptogenic stroke (6.0%). Freedom from SADEs at 1 month was 99.4% (95% Confidence Interval: 98.8-99.7%). In the 6-month monitoring period, the ICM detected true cardiac arrhythmias in 45.7% of patients and led to clinical interventions in a relevant proportion of patients; in particular, a pacemaker implant was performed after bradycardia detection in 8.9% of subjects who received an ICM for syncope and oral anticoagulation therapy was indicated after AF detection in 15.7% of subjects with cryptogenic stroke. PREMs showed that 78.2% of subjects were satisfied with the remote monitoring patient app. CONCLUSION: The evaluated ICM is associated with an excellent safety profile and high diagnostic yield. Patients reported positive experiences associated with the use of their smartphone for the device remote monitoring.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Humanos , Bradicardia/complicações , Eletrocardiografia Ambulatorial/métodos , Fibrilação Atrial/diagnóstico , Síncope/diagnóstico , Síncope/epidemiologia , Sistema de Registros
6.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38011712

RESUMO

AIMS: Epicardial adipose tissue might promote atrial fibrillation (AF) in several ways, including infiltrating the underlying atrial myocardium. However, the role of this potential mechanism has been poorly investigated. The aim of this study is to evaluate the presence of left atrial (LA) infiltrated adipose tissue (inFAT) by analysing multi-detector computer tomography (MDCT)-derived three-dimensional (3D) fat infiltration maps and to compare the extent of LA inFAT between patients without AF history, with paroxysmal, and with persistent AF. METHODS AND RESULTS: Sixty consecutive patients with AF diagnosis (30 persistent and 30 paroxysmal) were enrolled and compared with 20 age-matched control; MDCT-derived images were post-processed to obtain 3D LA inFAT maps for all patients. Volume (mL) and mean signal intensities [(Hounsfield Units (HU)] of inFAT (HU -194; -5), dense inFAT (HU -194; -50), and fat-myocardial admixture (HU -50; -5) were automatically computed by the software. inFAT volume was significantly different across the three groups (P = 0.009), with post-hoc pairwise comparisons showing a significant increase in inFAT volume in persistent AF compared to controls (P = 0.006). Dense inFAT retained a significant difference also after correcting for body mass index (P = 0.028). In addition, more negative inFAT radiodensity values were found in AF patients. Regional distribution analysis showed a significantly higher regional distribution of LA inFAT at left and right superior pulmonary vein antra in AF patients. CONCLUSION: Persistent forms of AF are associated with greater degree of LA intramyocardial adipose infiltration, independently of body mass index. Compared to controls, AF patients present higher LA inFAT volume at left and right superior pulmonary vein antra.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Átrios do Coração/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia , Ablação por Cateter/métodos
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37125968

RESUMO

AIMS: Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF. METHODS AND RESULTS: Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 ± 9.5 years) were included. Procedure time was 57 min (IQR 50-67), fluoroscopy time was 43 s (IQR 20-71), and radiofrequency (RF) time was 16.5 min (IQR 14.3-18.4). The median AI tailored to the local LAWT was 387 (IQR 360-410) for the anterior wall and 335 (IQR 300-375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up. CONCLUSION: In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Resultado do Tratamento
8.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36932709

RESUMO

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/diagnóstico , Seguimentos , Estudos Prospectivos , Cardioversão Elétrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
9.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37350404

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Administração Intravenosa , Antibacterianos , Hospitalização , Resultado do Tratamento
10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37724686

RESUMO

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Humanos , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Bradicardia , Progressão da Doença , Trifosfato de Adenosina
11.
Europace ; 25(4): 1423-1431, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794691

RESUMO

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos de Casos e Controles , Morte Súbita Cardíaca/etiologia , Estudos Retrospectivos , Resultado do Tratamento
12.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37536671

RESUMO

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Cardiomiopatias , Canalopatias , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Canalopatias/complicações , Canalopatias/terapia , Resultado do Tratamento , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Sistema de Registros
13.
Heart Vessels ; 38(5): 680-688, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36418560

RESUMO

No real-world data are available about the complications rate in drug-induced type 1 Brugada Syndrome (BrS) patients with an implantable cardioverter-defibrillator (ICD). Aim of our study is to compare the device-related complications, infections, and inappropriate therapies among drug-induced type 1 BrS patients with transvenous- ICD (TV-ICD) versus subcutaneous-ICD (S-ICD). Data for this study were sourced from the IBRYD (Italian BRugada sYnDrome) registry which includes 619 drug-induced type-1 BrS patients followed at 20 Italian tertiary referral hospitals. For the present analysis, we selected 258 consecutive BrS patients implanted with ICD. 198 patients (76.7%) received a TV-ICD, while 60 a S-ICD (23.4%). And were followed-up for a median time of 84.3 [46.5-147] months. ICD inappropriate therapies were experienced by 16 patients (6.2%). 14 patients (7.1%) in the TVICD group and 2 patients (3.3%) in S-ICD group (log-rank P = 0.64). ICD-related complications occurred in 31 patients (12%); 29 (14.6%) in TV-ICD group and 2 (3.3%) in S-ICD group (log-rank P = 0.41). ICD-related infections occurred in 10 patients (3.88%); 9 (4.5%) in TV-ICD group and 1 (1.8%) in S-ICD group (log-rank P = 0.80). After balancing for potential confounders using the propensity score matching technique, no differences were found in terms of clinical outcomes between the two groups. In a real-world setting of drug-induced type-1 BrS patients with ICD, no significant differences in inappropriate ICD therapies, device-related complications, and infections were shown among S-ICD vs TV-ICD. However, a reduction in lead-related complications was observed in the S-ICD group. In conclusion, our evidence suggests that S-ICD is at least non-inferior to TV-ICD in this population and may also reduce the risk of lead-related complications which can expose the patients to the necessity of lead extractions.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/etiologia , Pontuação de Propensão , Cardioversão Elétrica/efeitos adversos , Eletrocardiografia/métodos , Morte Súbita Cardíaca/epidemiologia , Resultado do Tratamento
14.
Eur Heart J Suppl ; 25(Suppl B): B12-B15, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37091634

RESUMO

Hypertrophic cardiomyopathy (HCM) is a genetic disease of the myocardium that is relatively common in the general population, with an autosomal dominant inheritance as a genetic basis. Clinical and natural history pathways can be very different among patients with HCM. Treatment strategies have made very important advances in the last two decades, especially reducing cases of sudden death through effective risk stratification and the use of implantable defibrillators. Heart failure has become the predominant cause of morbidity and mortality in patients with HCM, being responsible for as many as 60% of disease-related deaths. HCM is most often characterized by the presence of left ventricular outflow tract (LVOT) obstruction, and this obstruction is the most frequent cause of impaired exercise tolerance in HCM and a strong independent predictor of heart failure progression and mortality. The different treatment strategies of LVOT obstruction in HCM are discussed below: surgical, invasive, and the more recent pharmacological.

15.
J Cardiovasc Electrophysiol ; 33(1): 81-89, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34797012

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an effective alternative to the transvenous ICD. No study has yet compared S-ICD and transvenous ICD by assessing patient acceptance as a patient-centered outcome. OBJECTIVE: To evaluate the patient acceptance of the S-ICD and to investigate its association with clinical and implantation variables. In patients with symptomatic heart failure and reduced ejection fraction (HFrEF), the acceptance of the S-ICD was compared with a control group of patients who received a transvenous ICD. METHODS: Patient acceptance was calculated with the Florida Patient Acceptance Survey (FPAS) which measures four factors: return to function (RTF), device-related distress (DRD), positive appraisal (PA), and body image concerns (BIC). The survey was administered 12 months after implantation. RESULTS: 176 patients underwent S-ICD implantation. The total FPAS and the single factors did not differ according to gender, body habitus, or generator positioning. Patients with HFrEF had lower FPAS and RTF. Younger patients showed better RTF (75 [56-94] vs. 56 [50-81], p = .029). Patients who experienced device complications or device therapies showed higher DRD (40 [35-60] vs. 25 [10-50], p = .019). Patients with HFrEF receiving the S-ICD had comparable FPAS, RTF, DRD, and BIC to HFrEF patients implanted with the transvenous ICD while exhibited significantly better PA (88 [75-100] vs. 81 [63-94], p = .02). CONCLUSIONS: Our analysis revealed positive patient acceptance of the S-ICD, even in groups at risk of more distress such as women or patients with thinner body habitus, and regardless of the generator positioning. Among patients receiving ICDs for HFrEF, S-ICD was associated with better PA versus transvenous ICD.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Inquéritos e Questionários , Resultado do Tratamento
16.
Europace ; 24(9): 1384-1394, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-34966939

RESUMO

The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at high risk of sudden cardiac death. The heterogeneity of clinical scenarios in HCM and the availability of ICDs with distinct characteristics emphasizes the need for selecting the right device for the right patient. There is growing awareness that unnecessarily complex devices can lead to short- and long-term complications without adding significant clinical benefits. Young patients have the greatest potential years of life gained from the ICD but are also most exposed to device-related complications. This increases the complexity of decision-making of ICD prescription in these often otherwise well patients in whom device selection should be tailored to preserve survival benefit without introducing morbidity. In the light of the multiple clinical phenotypes characterizing HCM, the present article offers evidence-based perspectives helpful in predicting the individual impact of the ICD and choosing the most appropriate device.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Medição de Risco , Fatores de Risco
17.
J Cardiovasc Electrophysiol ; 32(6): 1695-1703, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33969578

RESUMO

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.


Assuntos
Desfibriladores Implantáveis , Índice de Massa Corporal , Cardioversão Elétrica/efeitos adversos , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Tela Subcutânea , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 31(8): 2093-2098, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32437006

RESUMO

INTRODUCTION: The prognostic impact of nonsustained ventricular tachycardia (NSVT) morphology has never been explored in hypertrophic cardiomyopathy (HCM). In a single-center cohort of consecutive HCM patients implanted with an implanted cardioverter-defibrillator (ICD), we assessed NSVT morphology patterns and their prognostic implications. METHODS: A cohort of consecutive HCM patients implanted with an ICD was followed from ICD implantation to last follow-up visit. Patients were assessed for NSVT as stored events in ICD memory. Ventricular tachycardias (VTs) were classified as monomorphic (MM) or polymorphic according to intracardiac electrogram morphology. RESULTS: One hundred nine consecutive HCM patients (68 males; mean age: 45 ± 17 years) composed the study population. During follow-up (71 ± 48 months), 7 polymorphic NSVT in 4 patients and 370 MM NSVT in 42 patients were retrieved from ICD memory. Among patients with only MM NSVT, 19 (45%) had one morphology, 17 (41%) had two morphologies, 3 (7%) had three morphologies, and 3 (7%) had four morphologies. Patients with polymorphic NSVT had the highest risk of ICD interventions (HR, 5.04; 95% CI, 1.26-20.19; P = .02). A stepwise increase of the risk of ICD interventions in patients with two, three, and four NSVT morphologies was observed. Out of 16 patients with both NSVT and ICD-treated VTs, 13 (81%) had at least one ICD-treated VT with the same morphology of a previous long-lasting NSVT. CONCLUSIONS: In high-risk HCM patients, the occurrence of polymorphic NSVT and of NSVT with multiple morphologies carries a high risk for ICD interventions. Sustained VTs tend to recur with the same morphology of previous long-lasting NSVTs.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Taquicardia Ventricular , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/terapia , Cardioversão Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia
19.
Europace ; 22(12): 1822-1829, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33118017

RESUMO

AIMS: The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing. We assessed whether the S-ICD implantation technique affects optimal position of the defibrillation system according to the PRAETORIAN score. METHODS AND RESULTS: We analysed consecutive patients undergoing S-ICD implantation. The χ2 test and regression analysis were used to determine the association between the PRAETORIAN score and implantation technique. Two hundred and thirteen patients were enrolled. The S-ICD generator was positioned in an IM pocket in 174 patients (81.7%) and the two-incision approach was adopted in 199 (93.4%). According to the PRAETORIAN score, the risk of conversion failure was classified as low in 198 patients (93.0%), intermediate in 13 (6.1%), and high in 2 (0.9%). Patients undergoing the two-incision and IM technique were more likely to have a low (<90) PRAETORIAN score than those undergoing the three-incision and subcutaneous technique (two-incision: 94.0% vs. three-incision: 78.6%; P = 0.004 and IM: 96.0% vs. subcutaneous: 79.5%; P = 0.001). Intermuscular plus two-incision technique was associated with a low-risk PRAETORIAN score (hazard ratio 3.76; 95% confidence interval 1.01-14.02; P = 0.04). Shock impedance was lower in PRAETORIAN low-risk patients than in intermediate-/high-risk categories (66 vs. 96 Ohm; P = 0.001). The PRAETORIAN score did not predict shock failure at 65 J. CONCLUSION: In this cohort of S-ICD recipients, combining the two-incision technique and IM generator implantation yielded the lowest PRAETORIAN score values, indicating optimal defibrillation system position. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/ Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Estudos de Coortes , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Fatores de Risco
20.
Pacing Clin Electrophysiol ; 42(6): 610-616, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30903669

RESUMO

BACKGROUND: In hypertrophic cardiomyopathy (HCM) patients implanted with an implantable cardioverter defibrillator (ICD), clinical outcomes of antitachycardia pacing (ATP) have been poorly explored. In a retrospective analysis of a cohort of consecutive HCM patients implanted with an ICD, we aimed to assess the efficacy, safety, and clinical value of ATP. METHODS: The cohort of HCM patients implanted with a transvenous ICD and followed in our center was assessed for device intervention from implantation to last clinical follow-up. RESULTS: Overall 77 patients (45 males; mean age: 46 ± 16 years) were analyzed. After 67 ± 41 months, 24 patients had 49 ventricular tachycardia/fibrillation (VT/VF) appropriately treated (5.8% per year). Among 39 monomorphic VTs, ATP was effective in 27 (success rate: 69%). Mean time from VT onset to ATP delivery was 9.1 ± 4.9 s. The only clinical variable improving ATP success was use of beta-blockers (81% vs 50%; P = .04). Out of 12 ineffectively treated VTs, one was immediately shocked, four self-terminated after 18 ± 12 s, and seven (18%) were accelerated to a new VT. ATP was also delivered for 27 of 42 inappropriately detected episodes and induced two de novo VTs (7%). In the per patient analysis, 14 out 77 (18%) patients had one or more appropriate and effective ATP (3.4% per year), and only six (8%; 1.4% per year) received more than one ATP. CONCLUSION: ATP is moderately effective for the treatment of monomorphic VTs in HCM patients. However, the rate of appropriate ATP therapies is low, ATP is often prematurely delivered, and ATP-induced arrhythmia degeneration is of concern.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Desfibriladores Implantáveis , Taquicardia Ventricular/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Estudos Retrospectivos , Medição de Risco , Prevenção Secundária
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa