Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Lasers Med Sci ; 38(1): 261, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37947919

RESUMO

COVID-19 Related Long-Term Taste Impairment (CRLTTI) is a condition that can be expressed after COVID-19 contagion, lasting for months or even years, affecting the routine and quality of life of individuals. Participants expressing CRLTTI, with a minimum of 2 months, attested by PCR-RT test were assessed for taste and smell, and underwent experimental treatments in 6 distinct groups: Photobiomodulation (PBM) in tongue dorsum and lateral (660 nm, 808 nm, association of 660 and 808 nm), Transmucosal Laser Irradiation of Blood (TLIB)-ventral surface of tongue (660 nm), B complex supplementation, and Sham laser. No intergroup statistical differences were observed at the final evaluation, despite the tendencies of better results with PBM and TLIB observed. PBM, TLIB, and B complex might be treatment options in the management of CRLTTI, despite the lack of total remission of taste and smell perception after 8 sessions (PBM and TLIB) or 30 days of B complex supplementation.


Assuntos
COVID-19 , Terapia com Luz de Baixa Intensidade , Humanos , COVID-19/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Qualidade de Vida , Paladar , Método Duplo-Cego
2.
Molecules ; 27(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35268785

RESUMO

This study aimed to investigate matrix metalloproteinase (MMP) activity in human dentin using in-situ and gelatin zymography, after at-home and in-office bleaching, related to their clinical exposure times. Dentin specimens (n = 5) were treated with 35% hydrogen peroxide (50 min per session/4 sessions), 10% carbamide peroxide (180 min/21 sessions), or no treatment. All were subjected to in-situ zymography. Dentin slices were, subsequently, obtained, covered with fluorescein-conjugated gelatin, and examined with confocal laser-scanning microscopy. The fluorescence intensity was quantified and statistically analyzed using one-way ANOVA and Bonferroni tests (α = 0.05). Furthermore, gelatin zymography was performed on protein extracts obtained from dentin powder (N = 8 teeth), treated with hydrogen peroxide or carbamide peroxide, with different exposure times (10/50 min for hydrogen peroxide; 252/1260 min for carbamide peroxide). The results of the in-situ zymography showed no statistical differences between the bleached specimens and the control group, with a medium level of gelatinolytic activity expressed in the dentin tubules. The results of gelatin zymography showed an increased expression of pro-MMP-9 in carbamide peroxide groups. The expression of pro-MMP-2 decreased in all the experimental groups. The bleaching treatments performed on the enamel of sound teeth do not influence dentinal enzymatic activity. However, when unprotected dentin tissue is bleached, matrix metalloproteinases are more expressed, particularly when carbamide peroxide is used, proportional to the exposure time.


Assuntos
Peróxido de Carbamida
3.
Caries Res ; 55(6): 617-628, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34689142

RESUMO

OBJECTIVES: This single-blind, controlled crossover in situ study aimed to evaluate the effect of CO2 laser (9.3 µm) irradiation combined with AmF/NaF/SnCl2 solution on prevention and control of erosive tooth wear (ETW) in human enamel. MATERIALS AND METHODS: Two trial conditions were analyzed, condition 1 as ETW prevention (sound tooth surface) and condition 2 as ETW control (in vitro initial erosive lesion). The experiment was conducted in 2 phases, one with and one without exposure to AmF/NaF/SnCl2 solution. Hundred and ninety-two samples of human enamel (3 × 3 × 1 mm) were randomly divided into 4 experimental groups for each condition: C, without treatment (negative control); F, AmF/NaF/SnCl2 solution (positive control); L, CO2 laser irradiation; and L + F, CO2 laser + AmF/NaF/SnCl2 solution. Twelve volunteers used a removable device, each containing 8 samples per phase. Ex vivo erosive challenges (4 × 5 min/day) and rinsing protocol (1 × 30 s/day) were performed. The surface loss was determined using optical profilometer (n = 12 per group), and the surface morphology was observed with scanning electron microscopy (n = 3). RESULTS: In condition 1, data were analyzed by one-way ANOVA and condition 2 by two-way repeated-measures ANOVA, both with Tukey post hoc tests (α = 5%). In condition 1, groups L (4.59 ± 2.95 µm) and L + F (1.58 ± 1.24 µm) showed significantly less surface loss in preventing ETW than groups C and F. In condition 2, in controlling the progression of ETW, L + F was the only group with no significant surface loss between initial erosive lesion (3.65 ± 0.16 µm) and after erosive challenge (4.99 ± 1.17 µm). CONCLUSIONS: CO2 9.3-µm laser application prevented and controlled ETW progression in human enamel, with greater efficiency when combined with AmF/NaF/SnCl2 solution application.


Assuntos
Lasers de Gás , Erosão Dentária , Desgaste dos Dentes , Esmalte Dentário , Humanos , Lasers de Gás/uso terapêutico , Método Simples-Cego , Fluoreto de Sódio/uso terapêutico , Erosão Dentária/etiologia , Erosão Dentária/prevenção & controle
4.
Lasers Med Sci ; 36(7): 1487-1495, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33216247

RESUMO

To evaluate the effect of Er:YAG laser conditioning of a glass-infiltrated alumina-based zirconia-reinforced ceramic on its flexural strength and on bonding to a resin cement. Sixteen blocks (5 × 5 × 4 mm) and 50 discs (Ø 12 mm, 1 mm thickness) of In-Ceram Zirconia (ICZ) obtained from CAD-CAM blocks were infiltrated with glass. For the microtensile bond strength (µTBS) test, all blocks were treated with aluminum oxide (AOX) and divided into 4 groups (n = 4): G1 (AOX), no combined surface treatment; G2 (ROC), tribochemical silica-coating; G3 (EY200), Er:YAG laser 200 mJ/15 Hz; and G4 (EY250), Er:YAG laser 250 mJ/10 Hz. The ceramic blocks were silanated and cemented with a resin cement (Panavia F2.0/Kuraray) to composite resin blocks and subjected to the µTBS test. For the flexural strength evaluation, the discs were divided into 5 groups (n = 10) as described above, in addition to a control group (G5 - CTRL, mirror-polished without further treatment). Each surface treatment was submitted to qualitative evaluation under SEM. One-way ANOVA (α = 5%) revealed the highest bond strength value for EY200 with no significant difference from ROC. The groups AOX and EY250 showed similar µTBS values that were statistically lower than those of EY200. For flexural strength, ROC was the only group with significantly lower values when compared with the CTRL. The use of Er:YAG laser at 200 mJ/15 Hz can be considered an innovative and effective alternative for surface conditioning of ICZ since it did not reduce the flexural strength of the ceramic and improved the resin cement bond to this substrate.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Cerâmica , Lasers de Estado Sólido/uso terapêutico , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Zircônio
5.
Lasers Med Sci ; 36(2): 311-315, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32372235

RESUMO

Biosafety materials used in the correct handling of low power laser equipment may interfere on the power delivered at the target tissue and, possibly, on the effects on biological tissues. The aim of this study was to evaluate the interference of the use of polyvinyl chloride (PVC) and polyethylene (PEAD) protection materials on the output power of low power lasers. Two low power diode laser devices with different wavelengths (red and infrared) were used. For each wavelength, two protection materials and two evaluation times (before and after protection) were considered. The output power (mW) was measured with the tip positioned in close contact with the power meter receiver. Parametric statistical test, two-way ANOVA for repeated measures (protection material and time), was performed considering the level of significance of 5%. In respect to "time", all groups had the output power reduced after placing the protective material (p < 0.05). Comparing the protection materials, the PEAD showed a greater reduction in output power than the PVC for both red and infrared wavelengths. It was concluded that, among the biosafety materials tested, PVC is the most suitable for the protection of the tip of the low power lasers.


Assuntos
Contenção de Riscos Biológicos , Lasers , Humanos , Raios Infravermelhos , Polietileno/química , Cloreto de Polivinila/química
6.
Lasers Med Sci ; 35(7): 1629-1636, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32382936

RESUMO

The aim of this study is to evaluate the ability of quantitative light-induced fluorescence (QLF) to monitor enamel caries lesions of different severity stages located on the occlusal surfaces of permanent teeth before and after treatment with resin infiltrant. Sixty extracted permanent teeth had one occlusal site selected and were categorized according to the International Caries Detection and Assessment System (ICDAS) criteria. The teeth were divided into three groups (n = 20): ICDAS 1, ICDAS 2, and ICDAS 3. The teeth were assessed by a trained examiner using QLF in two phases: (A) before and (B) after treatment with resin infiltrant. The caries lesions were evaluated using the following QLF parameters: area (mm2); ΔF, fluorescence loss (%); and ΔQ, fluorescence loss integrated over the lesion area (%*mm2). The resin infiltrant (Icon™) was applied on the occlusal surface following the manufacturer's recommendations. The teeth were then sectioned and prepared for polarized light microscopy analysis. The penetration of resin infiltrant was measured with ImageJ. The groups showed a statistically significant difference in all QLF parameters before and after caries infiltration, with the reduction of fluorescence values posttreatment (p < 0.05). Infiltrant penetration was observed in all groups, with a statistical difference between all groups (p < 0.05). The reduction in QLF parameters after resin infiltration suggests that QLF is able to monitor enamel caries lesions of different severity stages located on the occlusal surfaces of permanent teeth before and after treatment with resin infiltrant.


Assuntos
Cárie Dentária/diagnóstico , Esmalte Dentário/efeitos da radiação , Fluorescência Quantitativa Induzida por Luz , Resinas Sintéticas/farmacologia , Cárie Dentária/patologia , Esmalte Dentário/efeitos dos fármacos , Humanos , Dente/patologia
7.
Lasers Med Sci ; 34(7): 1391-1399, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30762196

RESUMO

The purpose of this study was to explore the influence of Er:YAG laser irradiation with different pulse durations on the organic matrix, micromorphology of the hybrid layer (HL), and bond strength over time. Sixty caries-free human molars were cut to obtain flat dentin surfaces which were randomly divided into 4 groups: control (not irradiated-G1) and laser groups (80 mJ/2 Hz) with pulse duration ranging between 50 (G2), 300 (G3), and 600 µs (G4). A self-etch adhesive system (Universal 3M ESPE) was applied on pre-treated dentin surfaces and cylinders of resin composite were built up and stressed in a universal testing machine (µSBS) at 24 h and after12 months (n = 12). In addition, 3 other dentin-bonded specimens were prepared as previously described for each group with the adhesive doped with 0.1 wt% Rhodamine B to analyze hybrid layer morphology under Confocal Laser Microscope Scanning (CLMS). Organic matrix and collagen fibrils were analyzed by second harmonic generation (SGH). Two-way ANOVA and Tukey's test detected significantly higher µSBS values for the control group, whereas the lower values were observed in all laser groups at 24 h (p < 0.05). Storage in artificial saliva did not reduce µSBS in all groups. The low signal emitted by SHG images below the irradiated area demonstrated thermal damage of the collagen matrix. CLMS images of laser groups exhibited thicker and irregular resin-dentin interfaces than the control group. Regardless of the pulse duration, Er:YAG laser pre-treatment altered the organic matrix and HL formation which resulted in low µSBS values at 24 h. The alterations on dentin's organic structure did not jeopardize the µSBS after 1 year of saliva storage.


Assuntos
Dentina/efeitos da radiação , Lasers de Estado Sólido , Resinas Sintéticas/efeitos da radiação , Colagem Dentária , Adesivos Dentinários/efeitos da radiação , Humanos , Resistência à Tração
8.
Gen Dent ; 67(3): 67-70, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31199748

RESUMO

In-office dental bleaching allows the dentist to have greater control of the procedure and prevents patients from ingesting chemicals. To obtain optimum results, in-office bleaching usually requires a longer period of application as well as changes of the bleaching agent applied to the tooth surfaces at each appointment. The objective of this case report was to assess, by means of a split-mouth design in a single patient, the final tooth color and tooth sensitivity resulting from 2 different bleaching protocols: 1 application of 35% hydrogen peroxide for 45 minutes and 3 applications of 35% hydrogen peroxide for 15 minutes each. Neither the patient nor 5 individuals who were blinded to the techniques noted a difference in the final esthetic results of the 2 protocols immediately after the procedure. In addition, the patient reported that no tooth sensitivity was associated with either protocol. The results of dental bleaching on both sides were maintained after 15 days. The results shown in the present case report suggest that there may be no need to renew the gel during in-office dental bleaching.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/etiologia , Sensibilidade da Dentina/prevenção & controle , Estética Dentária , Humanos , Peróxido de Hidrogênio/administração & dosagem , Peróxido de Hidrogênio/efeitos adversos , Clareamento Dental/métodos , Clareadores Dentários/administração & dosagem , Clareadores Dentários/efeitos adversos
10.
Lasers Med Sci ; 33(4): 745-753, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29204915

RESUMO

The present study aims to evaluate the current scientific data regarding the effectiveness of photobiomodulation (PBM) in the treatment of dentin hypersensitivity (DH) as an alternative method for pain control. A systematic review was conducted to assess the effectiveness of PBM as treatment for DH. A complete literature search was performed up to October 2016. Searches were conducted using Boolean operators and MeSH terms. References of all selected full-text articles and related reviews were scanned. A total of 280 articles were identified (241 articles were excluded by the title and abstract). Of the 39 articles selected for analysis, 36 were excluded because they presented one or more exclusion criteria. Therefore, three articles were qualified for inclusion in this systematic review. PBM may not lead to adverse effects provided that adequately controlled parameters are followed when treating DH. More consistent studies should be conducted in order to adequately observe the advantageous therapeutic effect of PBM.


Assuntos
Sensibilidade da Dentina/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Feminino , Humanos , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto
11.
Gen Dent ; 66(2): 69-73, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29513240

RESUMO

Despite nearly a century of research, the treatment of cervical dentinal hypersensitivity (DH) remains challenging. This case report discusses the indications for different approaches to the treatment of DH in a single patient; the chosen alternatives took into account the different degrees of tooth wear and levels of pain at different sites. A 31-year-old woman reported DH in the maxillary right canine and first premolar and the maxillary left lateral incisor and canine in response to thermal, tactile, and osmotic stimuli. Clinical examination revealed that the teeth on the right side presented noncarious cervical lesions deeper than 1 mm, while the teeth on the left side presented only minimal wear. Therefore, the right canine and premolar were restored with composite resin to create a mechanical barrier against stimuli and reestablish form, function, and esthetics. Prior to restoration, the teeth on the right side were irradiated with a low-power laser (808 nm, 100 mW, 1.1 J/point, 10 seconds), which was applied in a single session at 2 locations on each tooth. In contrast, the left lateral incisor and canine were irradiated in 3 sessions with the low-power laser, which reduces pain levels and depolarizes nerve fibers by means of cell biomodulation, and received no restorations. A visual analog scale (0.0-10.0) was used to record the patient's pain, and it was found that pain levels for the restored teeth decreased from 9.4 initially to 0.0 immediately after restoration, and pain levels for the irradiated teeth decreased from 5.4 initially to 2.0 after 3 sessions. After 6 months of clinical evaluation, both sets of teeth showed scores of 0.0 (no pain). Based on the results presented, it can be concluded that both treatments provided satisfactory outcomes when applied for the appropriate indication.


Assuntos
Restauração Dentária Permanente/métodos , Sensibilidade da Dentina/terapia , Terapia com Luz de Baixa Intensidade , Adulto , Dente Pré-Molar , Resinas Compostas/uso terapêutico , Dente Canino , Estética Dentária , Feminino , Humanos , Medição da Dor , Desgaste dos Dentes
12.
Oral Health Prev Dent ; 15(4): 365-370, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28831459

RESUMO

PURPOSE: To evaluate whether increasing the frequency of its use can enhance the protective effect of AmF/NaF/SnCl2 solution against dental erosion. MATERIALS AND METHODS: Sixty human enamel samples were obtained from sound human third molars, and after the formation of incipient erosive lesions (1% citric acid, pH 4.0, for 3 min), they were divided into five treatment groups (n = 12): G1 - deionised water (negative control); G2 - NaF solution (positive control) once a day; G3 - NaF solution (positive control) twice a day; G4 - AmF/NaF/SnCl2 solution once a day; G5 - AmF/NaF/SnCl2 solution twice a day. The samples were then subjected to 5 days of erosive cycling through 6 daily immersions (2 min each) in citric acid solution (0.05 M, pH 2.6). At the end of erosive cycling, surface wear was determined by means of optical profilometry. RESULTS: One-way ANOVA showed that the surface wear was affected by surface treatments (p < 0.001). Tukey's test showed no difference between the groups in which NaF was applied once or twice, but they showed limited reduction in wear compared to the deionised water group (G1). In the groups treated with the AmF/NaF/SnCl2 solution, there was a statistically significant difference between one and two application times (p < 0.001). Although both demonstrated statistically significantly reduced tissue loss, increasing the frequency increased its anti-erosive potential. CONCLUSION: The AmF/NaF/SnCl2 solution proved to be effective in reducing dental enamel surface loss and its use twice a day potentiated its anti-erosive effect.


Assuntos
Cariostáticos/administração & dosagem , Esmalte Dentário/efeitos dos fármacos , Fluoretos Tópicos/administração & dosagem , Fluoreto de Sódio/administração & dosagem , Compostos de Estanho/administração & dosagem , Erosão Dentária/prevenção & controle , Progressão da Doença , Combinação de Medicamentos , Humanos , Técnicas In Vitro , Soluções
13.
Gen Dent ; 65(4): e8-e11, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28682288

RESUMO

Postoperative sensitivity is one of the most common side effects of in-office bleaching with hydrogen peroxide. Laser phototherapy (LPT) has been suggested as an adjunctive treatment to prevent or minimize tooth sensitivity. This case report aimed to verify the efficacy of LPT in the reduction of sensitivity after in-office bleaching. Tooth bleaching was performed with 35% hydrogen peroxide activated with a hybrid LED-laser device. Immediately after the bleaching treatment, the patient reported dental sensitivity, as measured with a visual analog scale (VAS). To reduce sensitivity, LPT was applied with a 780-nm laser using the following parameters: 70 mW, exposure time of 10 seconds per point of irradiation (middle region of the buccal surfaces of each compromised tooth) in contact mode, energy of 1 J per point. Immediately after LPT, the patient reported a substantially lower level of pain on the VAS. Twenty-four hours after bleaching, the score on the VAS indicated that sensitivity levels had rebounded, and the patient received additional LPT. After 48 hours, the patient reported no dental sensitivity. The results in this patient indicated that irradiation with an infrared low-power laser substantially reduced dental pain generated by bleaching, suggesting that LPT should be considered as an auxiliary method to reduce postbleaching tooth sensitivity.


Assuntos
Sensibilidade da Dentina/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Clareamento Dental/efeitos adversos , Adulto , Sensibilidade da Dentina/etiologia , Humanos , Masculino , Medição da Dor
14.
Lasers Med Sci ; 30(2): 611-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23812850

RESUMO

One possible undesirable consequence of orthodontic therapy is the development of incipient caries lesions of enamel around brackets. The aim of this study was to compare the effects of CO2 (λ = 10.6 µm) and Nd:YAG (λ = 1,064 nm) lasers associated or not with topical fluoride application on the prevention of caries lesions around brackets. Brackets were bonded to the enamel of 65 premolars. The experimental groups (n = 13) were: G1--application of 1.23% acidulated fluoride phosphate gel (AFP, control); G2--Nd:YAG laser irradiation (0.6 W, 84.9 J/cm(2), 10 Hz, 110 µs, contact mode); G3--Nd:YAG laser irradiation associated with AFP; G4--CO2 laser irradiation (0.5 W, 28.6 J/cm(2), 50 Hz, 5 µs, and 10 mm focal distance); and G5--CO2 laser irradiation associated with AFP. Quantitative light-induced fluorescence was used to assess enamel demineralization. The data were statistically compared (α = 5%). The highest demineralization occurred in the Nd:YAG laser group (G2, 26.15% ± 1.94). The demineralization of all other groups was similar to that of the control group. In conclusion, CO2 laser alone was able to control enamel demineralization around brackets at the same level as that obtained with topical fluoride application.


Assuntos
Dente Pré-Molar/cirurgia , Cárie Dentária/prevenção & controle , Esmalte Dentário/efeitos da radiação , Lasers de Gás , Lasers de Estado Sólido , Braquetes Ortodônticos/efeitos adversos , Fluoretos/química , Humanos , Metais , Neodímio , Ortodontia/instrumentação , Fosfatos/química
15.
Lasers Med Sci ; 30(1): 17-26, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23649611

RESUMO

Limited information is available regarding the adhesion to eroded dentin. This study aims to evaluate the effect of different surface treatments on eroded dentin morphology and on microtensile bond strength (µTBS) of adhesive systems to this substrate. Ninety-six extracted third molars were randomly divided into eight groups (n = 12) according to the type of surface treatment and the adhesive system: G1 = Control + Clearfil SE Bond [SE], G2 = Diamond bur [DB] + SE, G3 = Er:YAG laser (60 mJ, 2 Hz, 0.12 W, 19.3 J/ cm(2)) + SE, G4 = Er,Cr:YSGG laser (50 mJ, 30 Hz, 1.5 W, 4.5 J/ cm(2)) + SE, G5 = Control + Single Bond [SB], G6 = DB + SB, G7 = Er:YAG + SB, G8 = Er,Cr:YSGG + SB. The erosive cycling was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1 h, between acid attacks), during 5 days. Blocks of composite were bonded to the samples according to the manufacturers' instructions. After 24 h-storage in distilled/deionized water (37 °C), stick-shaped samples were obtained and submitted to µTBS test. Each surface treatment was analyzed under scanning electron microscopy (n = 4) and the bond strength values (megapascal) were analyzed by two-way ANOVA and Tukey tests (α = 0.05). All surface treatments lead to changes on eroded dentin. G4 showed the highest bond strength mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other groups (p < 0.05). The surface treatment with Er,Cr:YSGG laser irradiation (4.5 J/cm(2)/50 mJ/30 Hz/140 µs) prior to bonding with a self-etching adhesive system significantly increases adhesion to eroded dentin, as compared to conventional treatment.


Assuntos
Cromo/química , Cimentos Dentários/farmacologia , Dentina/efeitos da radiação , Érbio/química , Lasers de Estado Sólido/uso terapêutico , Erosão Dentária/radioterapia , Colagem Dentária , Dentina/efeitos dos fármacos , Dentina/ultraestrutura , Adesivos Dentinários/farmacologia , Humanos , Resistência à Tração/efeitos dos fármacos
16.
Lasers Med Sci ; 30(4): 1395-406, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24519261

RESUMO

Post-traumatic nerve repair represents a major challenge to health sciences. Although there have been great advances in the last few years, it is still necessary to find methods that can effectively enhance nerve regeneration. Laser therapy has been widely investigated as a potential method for nerve repair. Therefore, in this article, a review of the existing literature was undertaken with regard to the effects of low-power laser irradiation on the regeneration of traumatically/surgically injured nerves. The articles were selected using either electronic search engines or manual tracing of the references cited in key papers. In electronic searches, we used the key words as "paresthesia", "laser therapy", "low-power laser and nerve repair", and "laser therapy and nerve repair", considering case reports and clinical studies. According to the findings of the literature, laser therapy accelerates and improves the regeneration of the affected nerve tissues, but there are many conflicting results about laser therapy. This can be attributed to several variables such as wavelength, radiation dose, and type of radiation. All the early in vivo studies assessed in this research were effective in restoring sensitivity. Although these results indicate a potential benefit of the use of lasers on nerve repair, further double-blind controlled clinical trials should be conducted in order to standardize protocols for clinical application.


Assuntos
Terapia com Luz de Baixa Intensidade , Regeneração Nervosa/efeitos da radiação , Parestesia/radioterapia , Animais , Humanos , Parestesia/fisiopatologia
17.
Lasers Med Sci ; 29(2): 565-73, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23354743

RESUMO

The aim of this in vitro study was to evaluate the effect of different surface treatments (control, diamond bur, erbium-doped yttrium aluminum garnet (Er:YAG) laser, and erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser) on sound dentin surface morphology and on microtensile bond strength (µTBS). Sixteen dentin fragments were randomly divided into four groups (n = 4), and different surface treatments were analyzed by scanning electron microscopy. Ninety-six third molars were randomly divided into eight groups (n = 12) according to type of surface treatment and adhesive system: G1 = Control + Clearfil SE Bond (SE); G2 = Control + Single Bond (SB); G3 = diamond bur (DB) + SE; G4 = DB + SB, G5 = Er:YAG laser (2.94 µm, 60 mJ, 2 Hz, 0.12 W, 19.3 J/cm(2)) + SE; G6 = Er:YAG + SB, G7 = Er,Cr:YSGG laser (2.78 µm, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm(2)) + SE; and G8 = Er,Cr:YSGG + SB. Composite blocks were bonded to the samples, and after 24-h storage in distilled/deionized water (37 °C), stick-shaped samples were obtained and submitted to µTBS test. Bond strength values (in megapascal) were analyzed by two-way ANOVA and Tukey tests (α = 0.05). G1 (54.69 ± 7.8 MPa) showed the highest mean, which was statistically significantly higher than all the other groups (p < 0.05). For all treatments, SE showed higher bond strength than SB, except only for Er,Cr:YSGG treatment, in which the systems did not differ statistically from each other. Based on the irradiation parameters considered in this study, it can be concluded that Er:YAG and Er,Cr:YSGG irradiation presented lower values than the control group; however, their association with self-etching adhesive does not have a significantly negative effect on sound dentin (µTBS values of >20 MPa).


Assuntos
Adesivos/farmacologia , Adesivos Dentinários , Dentina/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Resistência à Tração , Bis-Fenol A-Glicidil Metacrilato , Colagem Dentária , Restauração Dentária Permanente/métodos , Dentina/ultraestrutura , Humanos , Microscopia Eletrônica de Varredura , Dente Serotino/efeitos da radiação
18.
Lasers Med Sci ; 29(4): 1517-29, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23584730

RESUMO

Recurrent herpes labialis is a worldwide life-long oral health problem that remains unsolved. It affects approximately one third of the world population and causes frequent pain and discomfort episodes, as well as social restriction due to its compromise of esthetic features. In addition, the available antiviral drugs have not been successful in completely eliminating the virus and its recurrence. Currently, different kinds of laser treatment and different protocols have been proposed for the management of recurrent herpes labialis. Therefore, the aim of the present article was to review the literature regarding the effects of laser irradiation on recurrent herpes labialis and to identify the indications and most successful clinical protocols. The literature was searched with the aim of identifying the effects on healing time, pain relief, duration of viral shedding, viral inactivation, and interval of recurrence. According to the literature, none of the laser treatment modalities is able to completely eliminate the virus and its recurrence. However, laser phototherapy appears to strongly decrease pain and the interval of recurrences without causing any side effects. Photodynamic therapy can be helpful in reducing viral titer in the vesicle phase, and high-power lasers may be useful to drain vesicles. The main advantages of the laser treatment appear to be the absence of side effects and drug interactions, which are especially helpful for older and immunocompromised patients. Although these results indicate a potential beneficial use for lasers in the management of recurrent herpes labialis, they are based on limited published clinical trials and case reports. The literature still lacks double-blind controlled clinical trials verifying these effects and such trials should be the focus of future research.


Assuntos
Herpes Labial/radioterapia , Terapia com Luz de Baixa Intensidade , Animais , Antivirais/uso terapêutico , Herpes Labial/tratamento farmacológico , Humanos , Fotoquimioterapia , Fármacos Fotossensibilizantes/uso terapêutico , Recidiva
19.
J Prosthet Dent ; 111(1): 35-41, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24176179

RESUMO

STATEMENT OF PROBLEM: Translucent fiber posts were developed to conduct light into the root canal more effectively, thereby contributing to the polymerization of dual-polymerized resin luting agents. However, there is no consensus in the literature regarding their effectiveness. PURPOSE: The purpose of this study was to evaluate the tensile bond strength of fiber posts with different degrees of translucency to bovine dentin with 3 types of resin luting agents. MATERIAL AND METHODS: Ninety bovine roots were endodontically treated and divided into 9 groups (n=10) according to the type of post (translucent, white, and black) and resin luting agent (dual-polymerized self-adhesive; dual-polymerized + etch-and-rinse adhesive system; and autopolymerized + etch-and-rinse adhesive system). Tensile tests were performed on a universal testing machine (0.5 mm/min). To determine tensile stress, the bond area of each specimen was calculated. Data were statistically analyzed with ANOVA, Kruskal-Wallis, and Mann-Whitney tests (α=.05). RESULTS: Mean (standard deviation) tensile bond strength values (5.53 ± 2.29 MPa) were significantly lower for translucent posts than for white (9.51 ± 1.31 MPa) and black posts (10.12 ± 3.44 MPa) with a dual-polymerized luting agent in combination with an adhesive system (P=.012). For white (6.02 ± 1.88 MPa) and black posts (4.14 ± 0.6 MPa), the self-adhesive luting agent led to lower tensile bond strength than the dual-polymerized luting agent in combination with an adhesive system (P=.003). Irrespective of post type, the autopolymerized luting agent provided the lowest tensile bond strength (P<.001). Microscopic analysis revealed that resin luting agents adhered more to the post surface than to the root dentin. CONCLUSION: Post translucency did not increase the tensile bond strength of dual-polymerized resin luting agents.


Assuntos
Colagem Dentária , Planejamento de Prótese Dentária , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Técnica para Retentor Intrarradicular/instrumentação , Cimentos de Resina/química , Condicionamento Ácido do Dente/métodos , Adesividade , Animais , Carbono/química , Fibra de Carbono , Bovinos , Colagem Dentária/métodos , Resinas Epóxi/química , Vidro/química , Luz , Cura Luminosa de Adesivos Dentários/métodos , Polimerização , Autocura de Resinas Dentárias/métodos , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Dente não Vital/terapia
20.
Photodiagnosis Photodyn Ther ; 42: 103245, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36640856

RESUMO

PURPOSE: There has been growing demand for dental bleaching worldwide, however, despite being effective, hydrogen peroxide (HP) can negatively affect the dental structure. Thus, new techniques, such as violet LED light have emerged and need to be studied. The aim of this study was to analyze and compare the effectiveness of violet LED light alone or combined with 35% HP gel. METHODS: Six different tooth bleaching techniques (n = 10) were performed in intrinsically pigmented bovine teeth: G1 - 35% HP (1x/week for 4 weeks, 45 min of gel application); G2 - 35% HP (1x/week for 4 weeks, 15 min of gel application); G3 - violet LED (1x/week for 4 weeks); G4 - violet LED (2x/week for 2 weeks); G5 - violet LED (4x/week for 1 week); G6 - Violet LED + 35% HP (hybrid technique, 1x/week for 4 weeks, 15 min of gel application). Specimens were submitted to color evaluation at predetermined times using Konica Minolta® spectrophotometer, and the surface morphology (n = 3) was qualitatively analyzed by Scanning Electron Microscope (SEM). Data of the color change test were analyzed considering a 5% level of significance. RESULTS: There was significant difference in color (p <0.05) for all groups after bleaching protocols. SEM analysis revealed that the greatest change in surface occurred in Group G1, with demineralization of the dental enamel. When considering the same time interval, there were no statistical differences for axis L*, but differences were shown for axis a* (G2, G3, G4 ≥ G1, G5 ≥ G6) and b* (G1, G2, G3, G4, G5 > G6). Regarding the comparison of ΔE00 between groups, results showed statistical difference between groups, with G1 ≥ G2, G5, G6 ≥ G3, G4. CONCLUSION: Bleaching protocols with less time (15 min) or no exposure to 35% HP (violet LED, 4x/week) could promote bleaching results as those obtained by the conventional technique using 35% HP for 45 min, with no enamel surface changes, showing to be a promising alternative to tooth bleaching.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Peróxido de Hidrogênio , Clareamento Dental/métodos , Clareadores Dentários/farmacologia , Ácido Hipocloroso
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa