1.
Radiother Oncol ; 195: 110229, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38492672

RESUMO

BACKGROUND AND PURPOSE: To evaluate the performance of automated surface-guided gating for left-sided breast cancer with DIBH and VMAT. MATERIALS AND METHODS: Patients treated in the first year after introduction of DIBH with VMAT were retrospectively considered for analysis. With automated surface-guided gating the beam automatically switches on/off, if the surface region of interest moved in/out the gating tolerance (±3 mm, ±3°). Patients were coached to hold their breath as long as comfortably possible. Depending on the patient's preference, patients received audio instructions during treatment delivery. Real-time positional variations of the breast/chest wall surface with respect to the reference surface were collected, for all three orthogonal directions. The durations and number of DIBHs needed to complete dose delivery, and DIBH position variations were determined. To evaluate an optimal gating window threshold, smaller tolerances of ±2.5 mm, ±2.0 mm, and ±1.5 mm were simulated. RESULTS: 525 fractions from 33 patients showed that median DIBH duration was 51 s (range: 30-121 s), and median 4 DIBHs per fraction were needed to complete VMAT dose delivery. Median intra-DIBH stability and intrafractional DIBH reproducibility approximated 1.0 mm in each direction. No large differences were found between patients who preferred to perform the DIBH procedure with (n = 21) and without audio-coaching (n = 12). Simulations demonstrated that gating window tolerances could be reduced from ±3.0 mm to ±2.0 mm, without affecting beam-on status. CONCLUSION: Independent of the use of audio-coaching, this study demonstrates that automated surface-guided gating with DIBH and VMAT proved highly efficient. Patients' DIBH performance far exceeded our expectations compared to earlier experiences and literature. Furthermore, gating window tolerances could be reduced.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Unilaterais da Mama/radioterapia , Adulto , Dosagem Radioterapêutica
2.
Radiother Oncol ; 200: 110458, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39069089

RESUMO

BACKGROUND AND PURPOSE: A novel Cone-Beam Computed Tomography (CBCT) named HyperSight provides superior CBCT image quality compared to conventional ring gantry CBCT imaging, and it is suitable for dose calculations for prostate cancer, but it comes with considerable additional costs. The aim of this study was to determine the added value of HyperSight CBCT imaging compared to conventional CBCT imaging in terms of organ visibility in the male pelvic region. MATERIALS AND METHODS: Twenty prostate cancer patients were included in this prospective clinical study. For each patient three CBCT pairs, consisting of HyperSight and conventional CBCT scans acquired on consecutive days, were included. CBCT scans were evaluated by four observers in terms of visibility of the prostate, bladder, rectum and seminal vesicles. Visibility was scored on a 1-to-5 scale and by annotating axial slices where the organs were hard to delineate. Lastly, observers indicated whether the CBCT scans were of sufficient quality for an online adaptive radiation therapy workflow. RESULTS: All four organs were better visible on HyperSight CBCT scans compared to conventional CBCT scans. The mean visibility scores increased from 3.1 to 4.5 on a 1--5 scale of and the mean number of annotated slices reduced from 4.5 to 1.1. 99% Of the HyperSight CBCT scans were considered suitable for an online adaptive workflow vs 25-83% for the conventional CBCT scans. CONCLUSION: HyperSight CBCT scans yielded a visibility of prostate, bladder, rectum and seminal vesicles comparable to planning CT scans and, can replace a repeat planning CT scan in case of anatomical changes requiring a new treatment plan.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias da Próstata , Humanos , Masculino , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Estudos Prospectivos , Idoso , Pessoa de Meia-Idade , Reto/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Glândulas Seminais/diagnóstico por imagem
4.
Artigo em Inglês | MEDLINE | ID: mdl-35243045

RESUMO

INTRODUCTION: Nowadays, deep inspiratory breath-hold is a common technique to reduce heart dose in left-sided breast radiotherapy. This study evaluates the evolution of the breath-hold technique in our institute, from portal imaging during dose delivery to continuous monitoring with surface-guided radiotherapy (SGRT). MATERIALS AND METHODS: Setup data and portal imaging results were analyzed for 98 patients treated before 2014, and SGRT data for 228 patients treated between 2018 and 2020. For the pre-SGRT group, systematic and random setup errors were calculated for different correction protocols. Residual errors and reproducibility of breath-holds were evaluated for both groups. The benefit of using SGRT for initial positioning was evaluated for another cohort of 47 patients. RESULTS: Online correction reduced the population mean error from 3.9 mm (no corrections) to 1.4 mm. Despite online setup correction, deviations greater than 3 mm were observed in about 10% and 20% of the treatment beams in ventral-dorsal and cranial-caudal directions, respectively. However, these percentages were much smaller than with offline protocols or no corrections. Mean absolute differences between breath-holds within a fraction were smaller in the SGRT-group (1.69 mm) than in the pre-SGRT-group (2.10 mm), and further improved with addition of visual feedback (1.30 mm). SGRT for positioning did not improve setup accuracy, but slightly reduced the time for imaging and setup correction, allowing completion within 3.5 min for 95% of fractions. CONCLUSION: For accurate radiotherapy breast treatments using deep inspiration breath-hold, daily imaging and correction is required. SGRT provides accurate information on patient positioning during treatment and improves patient compliance with visual feedback.