Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Environ Sci Technol ; 52(2): 628-637, 2018 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-29257678

RESUMO

Sorption is an important natural and technical process. Sorption coefficients are typically determined in batch experiments, but this may be challenging for weakly sorbing compounds. An alternative method enabling analysis of those compounds is column chromatography. A column packed with the sorbent is used and sorption data are determined by relating sorbate retention to that of a nonretarded tracer. In this study, column chromatography was applied for the first time to study sorption of previously hardly investigated heterocyclic organic compounds to multiwalled carbon nanotubes (MWCNTs). Sorption data for these compounds are very limited in literature, and weak sorption is expected from predictions. Deuterium oxide was used as nonretarded tracer. Sorption isotherms were well described by the Freundlich model and data showed reasonable agreement with predicted values. Sorption was exothermic and physisorption was observed. H-bonding may contribute to overall sorption, which is supported by reduced sorption with increasing ionic strength due to blocking of functional groups. Lowering pH reduced sorption of ionizable compounds, due to electrostatic repulsion at pH 3 where sorbent as well as sorbates were positively charged. Overall, column chromatography was successfully used to study sorption of heterocyclic compounds to MWCNTs and could be applied for other carbon-based sorbents.


Assuntos
Compostos Heterocíclicos , Nanotubos de Carbono , Adsorção , Carbono , Compostos Orgânicos , Concentração Osmolar
2.
Environ Sci Technol ; 52(17): 9731-9740, 2018 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-30075076

RESUMO

Sorption studies of carbon-based materials and nanomaterials are typically conducted using batch experiments, but the analysis of weakly sorbing compounds may be challenging. Column chromatography represents a promising complement as higher sorbent to solution ratios can be applied. The sorbent is packed in a column, and sorption data are calculated by relating sorbate retention times to that of a nonretarded tracer. In this study, sorption of heterocyclic organic compounds (pyrazole, pyrrole, furan, and thiophene) by carbon-based materials (activated carbon, biochar, and graphite) and nanomaterials (functionalized carbon nanotubes and graphene platelets) was compared for the first time using column chromatography. D2O was used as nonretarded tracer. Sorption isotherms were nonlinear and described well by the Freundlich model. Sorption differed between the materials regarding determined Freundlich coefficients ( Kf) by more than two orders of magnitude for isotherms in a similar concentration range. Normalization of Kf with the surface area of the sorbent significantly reduced but did not remove the differences between the sorbents. Overall, column chromatography represents the opportunity to study sorption of weakly sorbing compounds to diverse carbon-based sorbent materials with a single experimental approach, which is challenging in batch experiments because of the very different sorption properties of some sorbent materials.


Assuntos
Grafite , Nanotubos de Carbono , Adsorção , Cromatografia Líquida , Compostos Orgânicos
3.
Water Res ; 219: 118549, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35561623

RESUMO

Wastewater treatment plants (WWTPs) may represent point sources for microplastic discharge into the environment. Quantification of microplastic in effluents of WWTPs has been targeted by several studies although standardized methods are missing to enable a comparability of results. This study discusses theoretical and practical perspectives on best practices for microplastic sampling campaigns of WWTPs. One focus of the study was the potential for synergies between thermoanalytical and spectroscopic analysis to gain more representative sampling using the complementary information provided by the different analytical techniques. Samples were obtained before and after sand filtration from two WWTPs in Germany using cascade filtration with size classes of 5,000 - 100 µm, 100 - 50 µm, and 50 - 10 µm. For spectroscopic methods samples were treated by a Fenton process to remove natural organic matter, whereas TED-GC-MS required only sample extraction from the filter cascade. µFTIR spectroscopy was used for the 100 µm and 50 µm basket filters and µRaman spectroscopy was applied to analyze particles on the smallest basket filter (10 µm). TED-GC-MS was used for all size classes as it is size independent. All techniques showed a similar trend, where PE was consistently the most prominent polymer in WWTP effluents. Based on this insight, PE was chosen as surrogate polymer to investigate whether it can describe the total polymer removal efficiency of tertiary sand filters. The results revealed no significant difference (ANOVA) between retention efficiencies of tertiary sand filtration obtained using only PE and by analyzing all possible polymers with µFTIR and µRaman spectroscopy. Findings from this study provide valuable insights on advantages and limitations of cascade filtration, the benefit of complementary analyses, a suitable design for future experimental approaches, and recommendations for future investigations.


Assuntos
Poluentes Químicos da Água , Purificação da Água , Monitoramento Ambiental , Microplásticos , Plásticos/análise , Polímeros , Análise Espectral , Águas Residuárias/química , Poluentes Químicos da Água/análise
4.
MethodsX ; 7: 100778, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32300541

RESUMO

The combination of a representative microplastic sampling method and a fast-quantitative analysis using Pyrolysis-GC-MS (Py-GC-MS) for investigation of the microplastic load and mass balances is presented in this work. A representative microplastic filtration requires a method allowing quick extraction of the sample. The developed steel based cascadic microplastic filtration uses steel basket filters with mesh sizes of 100 µm, 50 µm and 10 µm and a mean recovery of 86 % without cross contamination was achieved. Thermoanalytical methods have the advantage of minimal sample preparation with short analysis times. The presented platinum filament-based Py-GC-MS method requires little sample preparation and quantification limits for polystyrene (PS) and polyethylene (PE) were 0.03 µg and 1 µg absolute, respectively. The relative standard deviation of the analytical method is 11 %. The combined method allows representative sampling and analysis of MP from water bodies and waste water treatment plants within 48 h. •Presentation of a validated steel based cascadic microplastic filtration plant.•Fast and reproduceable Py-GC-MS analysis method for microplastic.•Py-GC-MS allows microplastic analysis with little sample preparation.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa