1.
Clin Chem Lab Med ; 61(7): 1280-1287, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37043622

RESUMO

OBJECTIVES: Monitoring quality indicators (QIs) is an important part of laboratory quality assurance (QA). Here, the Canadian Society of Clinical Chemists (CSCC) Point of Care Testing (POCT) and QI Special Interest Groups describe a process for establishing and monitoring QIs for POCT glucose testing. METHODS: Key, error prone steps in the POCT glucose testing process were collaboratively mapped out, followed by risk assessment for each step. Steps with the highest risk and ability to detect a non-conformance were chosen for follow-up. These were positive patient identification (PPID) and repeat of critically high glucose measurements. Participating sites were asked to submit aggregate data for these indicators from their site(s) for a one-month period. The PPID QI was also included as part of a national QI monitoring program for which fifty-seven sites submitted data. RESULTS: The percentage of POCT glucose tests performed without valid PPID ranged from 0-87%. Sites without Admission-Discharge-Transfer (ADT) connectivity to POCT meters were among those with the highest percentage of POCT glucose tests performed without valid PPID. The percentage repeated critically high glucose measurements ranged from 0-50%, indicating low compliance with this recommendation. A high rate of discordance was also noted when critically high POCT glucose measurements were repeated, demonstrating the importance of repeat testing prior to insulin administration. CONCLUSIONS: Here, a process for establishing these QIs is described, with preliminary data for two QIs chosen from this process. The findings demonstrate the importance of QIs for identification and comparative performance monitoring of non-conformances to improve POCT quality.


Assuntos
Glucose , Sistemas Automatizados de Assistência Junto ao Leito , Indicadores de Qualidade em Assistência à Saúde , Canadá , Opinião Pública , Glucose/química , Testes Imediatos , Humanos
2.
Infect Immun ; 90(1): e0047921, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34662213

RESUMO

A variety of eubacteria, plants, and protozoa can modify membrane lipids by cyclopropanation, which is reported to modulate membrane permeability and fluidity. The ability to cyclopropanate membrane lipids has been associated with resistance to oxidative stress in Mycobacterium tuberculosis, organic solvent stress in Escherichia coli, and acid stress in E. coli and Salmonella. In bacteria, the cfa gene encoding cyclopropane fatty acid (CFA) synthase is induced during the stationary phase of growth. In the present study, we constructed a cfa mutant of Salmonella enterica serovar Typhimurium 14028s (S. Typhimurium) and determined the contribution of CFA-modified lipids to stress resistance and virulence in mice. Cyclopropane fatty acid content was quantified in wild-type and cfa mutant S. Typhimurium. CFA levels in the cfa mutant were greatly reduced compared to CFA levels in the wild type, indicating that CFA synthase is the major enzyme responsible for cyclopropane modification of lipids in Salmonella. S. Typhimurium cfa mutants were more sensitive to extreme acid pH, the protonophore CCCP, and hydrogen peroxide compared to the wild type. In addition, cfa mutants exhibited reduced viability in murine macrophages and could be rescued by the addition of the NADPH phagocyte oxidase inhibitor diphenyleneiodonium (DPI) chloride. S. Typhimurium lacking cfa was also attenuated for virulence in mice. These observations indicate that CFA modification of lipids makes an important contribution to Salmonella virulence.


Assuntos
Ciclopropanos/metabolismo , Ácidos Graxos/metabolismo , Infecções por Salmonella/microbiologia , Salmonella typhimurium/fisiologia , Animais , Fenômenos Fisiológicos Bacterianos , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Vias Biossintéticas , Ciclopropanos/química , Ciclopropanos/farmacologia , Modelos Animais de Doenças , Ácidos Graxos/química , Ácidos Graxos/farmacologia , Concentração de Íons de Hidrogênio , Macrófagos/efeitos dos fármacos , Macrófagos/imunologia , Macrófagos/microbiologia , Camundongos , Viabilidade Microbiana/efeitos dos fármacos , Viabilidade Microbiana/imunologia , Mutação , Estresse Oxidativo , Infecções por Salmonella/imunologia , Infecções por Salmonella/mortalidade , Salmonella typhimurium/efeitos dos fármacos , Virulência
3.
Clin Chem Lab Med ; 56(2): 327-340, 2018 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-28723610

RESUMO

BACKGROUND: Accurate reference intervals (RIs) based on a healthy pediatric population are essential for pediatric test result interpretation. The CALIPER project has recruited a large healthy cohort and completed a series of a priori studies to address gaps in pediatric RIs. As immunoassays from different manufacturers for endocrine and special chemistry markers are not standardized and show marked intermethod differences, direct RI studies are needed for each major analytical platform. Here, we report age- and sex-specific pediatric RIs for 29 immunoassays on the Ortho Clinical Diagnostics (Ortho) VITROS® 5600 analyzer. METHODS: Health information and blood samples were collected from healthy pediatric subjects. Using the Ortho VITROS 5600 Integrated System MicroWell Technology, 29 biomarkers were measured. Analyte concentrations were partitioned by age and sex according to the Harris and Boyd method. After removing outliers, age- and sex-specific RIs and corresponding 90% confidence intervals were calculated according to CLSI guidelines. RESULTS: All analytes required age partitioning except ß-human chorionic gonadotropin (ß-hCG), cancer antigen 15-3 (CA15-3), rubella immunoglobulin G (rubella IgG), and vitamin D. Several analytes including estradiol, progesterone, testosterone, follicle-stimulating hormone (FSH), luteinizing hormone (LH), free triiodothyronine (FT3), total triiodothyronine (TT3), total thyroxine (TT4), thyroid uptake, ferritin, intact parathyroid hormone (iPTH), total prostate-specific antigen (tPSA), free prostate-specific antigen (fPSA), cancer antigen 125 (CA125), creatine kinase MB (CK-MB), and myoglobin showed sex differences, observed mostly with the onset of puberty. CONCLUSIONS: Complex reference value trends were observed across the pediatric age range for several biomarkers examined on Ortho VITROS immunoassays. The availability of VITROS immunoassay RIs will enable accurate laboratory test interpretation and diagnosis for the pediatric population. As recommended by the CLSI EP28-A3c guidelines, implementation of these RIs should be validated for each laboratory's local pediatric population.


Assuntos
Biomarcadores/sangue , Imunoensaio/estatística & dados numéricos , Pediatria/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Voluntários Saudáveis , Humanos , Imunoensaio/normas , Lactente , Recém-Nascido , Masculino , Valores de Referência , Caracteres Sexuais , Maturidade Sexual
4.
Clin Chem Lab Med ; 56(6): 964-972, 2018 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-29389662

RESUMO

BACKGROUND: 1,25-dihydroxyvitamin D (1,25(OH)2D), the biologically active vitamin D metabolite, plays a critical role in calcium and phosphate homeostasis. 1,25(OH)2D is measured to assess calcium and phosphate metabolism, particularly during periods of profound growth and development. Despite its importance, no reliable pediatric reference interval exists, with those available developed using adult populations or out-dated methodologies. Using the fully automated chemiluminescence immunoassay by DiaSorin, we established 1,25(OH)2D pediatric reference intervals using healthy children and adolescents from the CALIPER cohort. METHODS: Serum samples from healthy subjects (0 to <19 years) were analyzed for 1,25(OH)2D using the DiaSorin LIAISON XL assay and age-specific reference intervals were established. The Mann-Whitney U-test was used to determine seasonal differences. Pooled neonatal and infantile samples were quantified using liquid chromatography tandem mass spectrometry (LC-MS/MS) to determine if elevated concentrations during the first year of life may be attributed to cross-reacting moieties. RESULTS: Three reference interval age partitions were required with highest levels in subjects 0 to <1 year (77-471 pmol/L), which declined and narrowed after 1 year (113-363 pmol/L) and plateaued at 3 years (108-246 pmol/L). 1,25(OH)2D concentration was not significantly affected by seasonal variation or sex. Elevated 1,25(OH)2D concentrations in neonatal and infantile samples may be the result of an interfering substance. The absence of 3-epi-1,25-dihydroxyvitamin D in the pooled samples makes it unlikely to be the interfering moiety. CONCLUSIONS: Pediatric reference intervals for 1,25(OH)2D were established to improve test result interpretation in children and adolescents. 1,25(OH)2D is elevated in a proportion of neonates and infants, which may be the result of a cross-reacting moiety.


Assuntos
Vitamina D/análogos & derivados , Adolescente , Criança , Cromatografia Líquida , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência , Estações do Ano , Espectrometria de Massas em Tandem , Vitamina D/sangue
6.
RNA ; 20(8): 1210-22, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24935875

RESUMO

Escherichia coli leucyl/phenylalanyl-tRNA protein transferase catalyzes the tRNA-dependent post-translational addition of amino acids onto the N-terminus of a protein polypeptide substrate. Based on biochemical and structural studies, the current tRNA recognition model by L/F transferase involves the identity of the 3' aminoacyl adenosine and the sequence-independent docking of the D-stem of an aminoacyl-tRNA to the positively charged cluster on L/F transferase. However, this model does not explain the isoacceptor preference observed 40 yr ago. Using in vitro-transcribed tRNA and quantitative MALDI-ToF MS enzyme activity assays, we have confirmed that, indeed, there is a strong preference for the most abundant leucyl-tRNA, tRNA(Leu) (anticodon 5'-CAG-3') isoacceptor for L/F transferase activity. We further investigate the molecular mechanism for this preference using hybrid tRNA constructs. We identified two independent sequence elements in the acceptor stem of tRNA(Leu) (CAG)-a G3:C70 base pair and a set of 4 nt (C72, A4:U69, C68)-that are important for the optimal binding and catalysis by L/F transferase. This maps a more specific, sequence-dependent tRNA recognition model of L/F transferase than previously proposed.


Assuntos
Aminoaciltransferases/metabolismo , Escherichia coli/genética , Escherichia coli/metabolismo , RNA de Transferência de Leucina/genética , Anticódon , Cinética , Conformação de Ácido Nucleico , Nucleotídeos , Aminoacil-RNA de Transferência , RNA de Transferência de Leucina/química , RNA de Transferência de Leucina/metabolismo , Especificidade por Substrato , Aminoacilação de RNA de Transferência
10.
Clin Biochem ; 125: 110731, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38360198

RESUMO

BACKGROUND: An analytical benchmark for high-sensitivity cardiac troponin (hs-cTn) assays is to achieve a coefficient of variation (CV) of ≤ 10.0 % at the 99th percentile upper reference limit (URL) used for the diagnosis of myocardial infarction. Few prospective multicenter studies have evaluated assay imprecision and none have determined precision at the female URL which is lower than the male URL for all cardiac troponin assays. METHODS: Human serum and plasma matrix samples were constructed to yield hs-cTn concentrations near the female URLs for the Abbott, Beckman, Roche, and Siemens hs-cTn assays. These materials were sent (on dry ice) to 35 Canadian hospital laboratories (n = 64 instruments evaluated) participating in a larger clinical trial, with instructions for storage, handling, and monthly testing over one year. The mean concentration, standard deviation, and CV for each instrument type and an overall pooled CV for each manufacturer were calculated. RESULTS: The CVs for all individual instruments and overall were ≤ 10.0 % for two manufacturers (Abbott CVpooled = 6.3 % and Beckman CVpooled = 7.0 %). One of four Siemens Atellica instruments yielded a CV > 10.0 % (CVpooled = 7.7 %), whereas 15 of 41 Roche instruments yielded CVs > 10.0 % at the female URL of 9 ng/L used worldwide (6 cobas e411, 1 cobas e601, 4 cobas e602, and 4 cobas e801) (CVpooled = 11.7 %). Four Roche instruments also yielded CVs > 10.0 % near the female URL of 14 ng/L used in the United States (CVpooled = 8.5 %). CONCLUSIONS: The number of instruments achieving a CV ≤ 10.0 % at the female 99th-percentile URL varies by manufacturer and by instrument. Monitoring assay precision at the female URL is necessary for some assays to ensure optimal use of this threshold in clinical practice.


Assuntos
Infarto do Miocárdio , Humanos , Masculino , Feminino , Estudos Prospectivos , Canadá , Infarto do Miocárdio/diagnóstico , Bioensaio , Troponina , Troponina T , Biomarcadores , Valores de Referência
11.
Phys Med ; 107: 102551, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36867911

RESUMO

PURPOSE: An ocular applicator that fits a commercial proton snout with an upstream range shifter to allow for treatments with sharp lateral penumbra is described. MATERIALS AND METHODS: The validation of the ocular applicator consisted of a comparison of range, depth doses (Bragg peaks and spread out Bragg peaks), point doses, and 2-D lateral profiles. Measurements were made for three field sizes, 1.5, 2, and 3 cm, resulting in 15 beams. Distal and lateral penumbras were simulated in the treatment planning system for seven range-modulation combinations for beams typical of ocular treatments and a field size of 1.5 cm, and penumbra values were compared to published literature. RESULTS: All the range errors were within 0.5 mm. The maximum averaged local dose differences for Bragg peaks and SOBPs were 2.6% and 1.1%, respectively. All the 30 measured point doses were within +/-3% of the calculated. The measured lateral profiles, analyzed through gamma index analysis and compared to the simulated, had pass rates greater than 96% for all the planes. The lateral penumbra increased linearly with depth, from 1.4 mm at 1 cm depth to 2.5 mm at 4 cm depth. The distal penumbra ranged from 3.6 to 4.4 mm and increased linearly with the range. The treatment time for a single 10 Gy (RBE) fractional dose ranged from 30 to 120 s, depending on the shape and size of the target. CONCLUSIONS: The ocular applicator's modified design allows lateral penumbra similar to dedicated ocular beamlines while enabling planners to use modern treatment tools such as Monte Carlo and full CT-based planning with increased flexibility in beam placement.


Assuntos
Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Síncrotrons , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos
12.
EJIFCC ; 34(2): 153-166, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37455838

RESUMO

Lithium is the first-line treatment for maintenance therapy in bipolar disorder. It is an effective mood stabilizer agent, and may have potential benefits in neuroprotection and reducing the risk of suicide. Toxicity has been a concern in recent decades, particularly in older adults (≥60 years). In 2019, the Older Adults Task Force within the International Society for Bipolar Disorder (ISBD) published recommendations for age-stratified lithium therapeutic ranges for therapy of Older Age Bipolar Disorder (OABD), namely 0.4 - 0.8 mmol/L for ages 60 to 79 and 0.4 - 0.7 mmol/L for ages 80 and above. Clinical laboratory practice surveys in Canada indicated that adoption and implementation of the proposed ranges has been limited to date. In this article, we describe the approach and steps taken to evaluate and implement recommended lithium therapeutic ranges in Ontario and other provinces in Canada for laboratory quality improvement. Sources of variation in lithium reporting practices are discussed and shared here to highlight potential barriers to implementation. The overall goal of this article is to bring attention across the global laboratory community that lower lithium therapeutic target ranges in older patients are crucial for patient safety in OABD.

13.
Horm Res Paediatr ; 96(3): 332-340, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36030768

RESUMO

INTRODUCTION: Hypervitaminosis D is a relatively uncommon etiology of hypercalcemia. Toxicity is usually caused by very high doses, mostly secondary to erroneous prescription or administration of vitamin D, and less commonly, contaminated foods or manufacturing errors of vitamin D-containing supplements. CASE PRESENTATION: A 16-year-old male, previously healthy, presented with 2-week history of nonspecific symptoms (fatigue, gastrointestinal complaints). Investigations showed acute kidney injury and hypercalcemia (total calcium 3.81 mmol/L). Further diagnostic workup revealed markedly elevated 25-hydroxyvitamin D levels (1,910 nmol/L). He denied taking any vitamin D supplements; however, he reported consumption of creatine and protein supplements. Mass spectrometry analysis of the creatine supplement estimated a vitamin D content of 425,000 IU per serving (100 times the upper tolerable daily dose). A few months later, another previously healthy adolescent presented with severe hypercalcemia and acute kidney injury secondary to hypervitaminosis D. He was also using a creatine supplement, from the same manufacturer brand and lot. Both patients were treated with intravenous hydration, calcitonin, and pamidronate. They maintained normocalcemia after their initial presentation but required low-calcium diets and laboratory testing for months after this exposure. DISCUSSION/CONCLUSION: We present 2 cases of hypervitaminosis D caused by a manufacturing error of a natural health product which did not claim to contain vitamin D. The use of dietary supplements is highly prevalent; this should be incorporated while taking medical history, and considered a potential source of toxicity when an alternative source cannot be found, regardless of the product label.


Assuntos
Injúria Renal Aguda , Hipercalcemia , Masculino , Humanos , Adolescente , Hipercalcemia/induzido quimicamente , Cálcio , Creatina , Vitamina D/efeitos adversos , Vitaminas/efeitos adversos , Suplementos Nutricionais/efeitos adversos , Injúria Renal Aguda/induzido quimicamente
16.
Clin Biochem ; 88: 11-17, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33264650

RESUMO

Point of Care Testing (POCT) refers to clinical laboratory testing performed outside the central laboratory, nearer to the patient and sometimes at the patient bedside. The testing is usually performed by clinical staff, such as physicians or nurses, who are not laboratory trained. This document was developed by the POCT Interest group of the Canadian Society of Clinical Chemists (CSCC) as practical guidance for quality assurance practices related to POCT performed in hospital and outside hospital environments. The aspects of quality assurance addressed in this document include: (1) device selection, (2) initial device verification, (3) ongoing device verification, (4) ongoing quality assurance including reagent and quality control (QC) lot changes, and (5) quality management including operator and document management.


Assuntos
Técnicas de Laboratório Clínico/normas , Testes Imediatos/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Canadá , Humanos , Guias de Prática Clínica como Assunto/normas , Controle de Qualidade
17.
J Clin Microbiol ; 48(1): 124-30, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19923482

RESUMO

Clostridium difficile is the most common infectious cause of diarrhea in hospitalized patients. The optimal approach for the detection of toxigenic C. difficile remains controversial because no single test is sensitive, specific, and affordable. We have developed a real-time PCR method (direct stool PCR [DPCR]) to detect the tcdB gene encoding toxin B directly from stool specimens and have combined it with enzyme immunoassays (EIAs) in a three-step protocol. DPCR was performed on 699 specimens that were positive for C. difficile glutamate dehydrogenase (GDH) by Wampole C Diff Quik Chek EIA (GDH-Q) and negative for toxins A and B by Wampole Tox A/B Quik Chek EIA (AB-Q), performed sequentially. The performance of this three-step algorithm was compared with a modified "gold standard" that combined tissue culture cytotoxicity (CYT) and DPCR. A separate investigation was performed to evaluate the sensitivity of the GDH-Q as a screening test, and toxigenic C. difficile was found in 1.9% of 211 GDH-Q-negative specimens. The overall sensitivity, specificity, and positive and negative predictive values, respectively, were as follows for an algorithm combining GDH-Q, AB-Q, and DPCR: 83.8%, 99.7%, 97.1%, and 97.9%. Those for CYT alone were 58.8%, 100%, 100%, and 94.9%, respectively. In comparison, the sensitivity and specificity of DPCR were estimated to be 97.5% and 99.7%, respectively, using the same modified gold standard. Neither CYT nor toxin EIA was sufficiently sensitive to exclude toxigenic C. difficile, and combining EIAs with CYT in a three-step algorithm failed to substantially improve sensitivity. DPCR is a sensitive and specific method for the detection of toxigenic C. difficile that can provide same-day results at a cost-per-positive test comparable to those of other methods. A three-step algorithm in which DPCR is used to analyze GDH EIA-positive, toxin EIA-negative specimens provides a convenient and specific alternative with rapid results for 87.7% of specimens, although this approach is less sensitive than performing DPCR on all specimens.


Assuntos
Proteínas de Bactérias/análise , Proteínas de Bactérias/genética , Toxinas Bacterianas/análise , Toxinas Bacterianas/genética , Técnicas Bacteriológicas/métodos , Clostridioides difficile/isolamento & purificação , Enterocolite Pseudomembranosa/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Reação em Cadeia da Polimerase/métodos , Adulto , Algoritmos , Clostridioides difficile/química , Clostridioides difficile/genética , Clostridioides difficile/patogenicidade , Fezes/química , Fezes/microbiologia , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Adulto Jovem
18.
Pract Lab Med ; 22: e00187, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33204792

RESUMO

Point of care testing (POCT) is one of the fastest growing disciplines in clinical laboratory medicine. POCT devices are widely used in both acute and chronic patient management in the hospital and primary physician office settings. As demands for POCT in various healthcare settings increase, managing the quality and regulatory compliance are continually challenging. Despite technological advances in applying automatic system checks and built-in quality control to prevent analytical and operator errors, poor planning for POCT connectivity and informatics can limit data accessibility and management efficiency which impedes the utilization of POCT to its full potential. This article will summarize how connectivity and data management system can improve timely access to POCT results, effective management of POCT programs, and ensure regulatory compliance.

19.
J Clin Pathol ; 73(2): 61-69, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31690564

RESUMO

Mass spectrometry-based assays have been increasingly implemented in various disciplines in clinical diagnostic laboratories for their combined advantages in multiplexing capacity and high analytical specificity and sensitivity. It is now routinely used in areas including reference methods development, therapeutic drug monitoring, toxicology, endocrinology, paediatrics, immunology and microbiology to identify and quantify biomolecules in a variety of biological specimens. As new ionisation methods, instrumentation and techniques are continuously being improved and developed, novel mass spectrometry-based clinical applications will emerge for areas such as proteomics, metabolomics, haematology and anatomical pathology. This review will summarise the general principles of mass spectrometry and specifically highlight current and future clinical applications in anatomical pathology.


Assuntos
Espectrometria de Massas , Patologia Clínica/métodos , Genômica/métodos , Humanos , Metabolômica/métodos , Imagem Molecular/métodos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
20.
Can J Kidney Health Dis ; 7: 2054358120970716, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33240520

RESUMO

BACKGROUND: The StatSensor is a point-of-care device which measures creatinine in capillary whole blood. Previous studies reported an underestimation of the creatinine measurements at high creatinine concentrations and were performed in the prestandardization era for creatinine. OBJECTIVE: This accuracy-based study evaluates the use of this device in kidney-transplanted patients and those with chronic kidney disease (CKD). DESIGN: Cross-sectional diagnostic accuracy study. SETTING: Nephrology outpatient clinic in an urban tertiary center. PARTICIPANTS: Adults with CKD or a functioning kidney transplant. MEASUREMENTS: Duplicate StatSensor creatinine measurements were performed on capillary whole blood samples collected by direct fingerstick and SAFE-T-FILL collection device. Results were compared with simultaneous venous blood sampling for serum and plasma creatinine measured by an enzymatic method on the Roche Integra 400 mainframe analyzer with traceability to the ID-GC-MS (isotope dilution gas chromatography mass spectrometry) reference method. METHODS: Deming regression, Pearson correlation coefficient, and Bland-Altman analysis were used to assess accuracy and comparability between capillary whole blood measured by StatSensor and plasma creatinine measured by routine analyzer with traceability to the reference method. Estimated glomerular filtration (eGFR) rates were calculated using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation and concordance with Kidney Disease Improving Global Outcomes (KDIGO) CKD stage classification was evaluated. RESULTS: There were 60 participants (mean age = 61.9 ± 15.0 years, 55% men, 33% transplant, mean plasma creatinine = 137 ± 59 µmol/L). Bland-Altman analysis indicated a positive mean bias of 12.7 µmol/L between StatSensor fingerstick creatinine measurement and plasma creatinine. Comparison of eGFR (CKD-EPI) calculated from the StatSensor fingerstick creatinine versus plasma creatinine showed misclassification across all KDIGO CKD stages. Postanalytical correction of the bias did not improve misclassifications. The use of mean of duplicate StatSensor creatinine results did not improve performance compared with the use of singlet results. LIMITATIONS: Single center, limited participant numbers. CONCLUSIONS: The results of our study suggest that the limiting characteristics of the StatSensor device are not only bias, but also imprecision. The level of imprecision observed may influence clinical decision-making and limit the usefulness of StatSensor as a CKD screening tool. If choosing to utilize it for either screening for or monitoring CKD, it is essential that clinicians understand the limitations of point-of-care devices and apply this knowledge to test interpretation.


CONTEXTE: Le StatSensor est un appareil portatif conçu pour mesurer le taux de créatinine dans le sang capillaire total. Des études antérieures, réalisées avant la standardisation des mesures de la créatinine, ont rapporté une sous-estimation des mesures à des concentrations élevées. OBJECTIF: Cette étude centrée sur la précision a examiné l'utilisation de cet appareil chez des patients transplantés d'un rein et des patients atteints d'insuffisance rénale chronique (IRC). TYPE D'ÉTUDE: Étude transversale centrée sur la précision du diagnostic. CADRE: La clinique ambulatoire de néphrologie d'un centre de soins tertiaires en milieu urbain. SUJETS: Des adultes atteints d'IRC ou transplantés avec un rein fonctionnel. MESURES: Les mesures de créatinine par StatSensor ont été effectuées en double sur des échantillons de sang capillaire total prélevés par ponction digitale directe et à l'aide du dispositif de prélèvement SAFE-T-FILL. Ces résultats ont été comparés à un prélèvement veineux simultané pour la mesure des taux de créatinine sérique et plasmatique par la méthode enzymatique avec l'analyseur Integra 400 de Roche avec traçabilité à la méthode de référence ID-GC-MS. MÉTHODOLOGIE: La régression de Deming, le coefficient de corrélation de Pearson et l'analyse de Bland-Altman ont été utilisés pour évaluer la précision et la comparabilité entre les mesures du sang capillaire total par StatSensor et la mesure de créatinine plasmatique obtenue par l'analyseur de routine avec traçabilité à la méthode de référence. Le débit de filtration glomérulaire estimé (DFGe) a été calculé avec l'équation CKD-EPI, puis la concordance avec la classification des stades KDIGO pour l'IRC a été évaluée. RÉSULTATS: L'étude a inclus 60 patients (55 % d'hommes; âge moyen 61,9 ± 15,0 ans) dont 33 % étaient transplantés. Le taux moyen de créatinine plasmatique s'établissait à 137 ± 59 µmol/L. L'analyse de Bland-Altman indique un biais positif moyen de 12,7 µmol/L entre la mesure de créatinine obtenue avec StatSensor par ponction digitale et le taux de créatinine plasmatique. La comparaison entre le DFGe (CKD-EPI) calculé à partir des mesures obtenues par ponction digitale avec StatSensor et de la mesure de créatinine plasmatique a montré une classification erronée à tous les stades KDIGO pour l'IRC. La correction du biais après l'analyse n'a pas amélioré les erreurs de classification. L'utilisation de la moyenne des résultats obtenus par StatSensor sur les échantillons prélevés en double n'a pas amélioré les performances par rapport à l'utilisation de singulets. LIMITES: Étude monocentrique, nombre de participants limité. CONCLUSION: Nos résultats suggèrent que les caractéristiques de limitation du StatSensor ne constituent pas qu'un biais, mais également une imprécision. Ce degré d'imprécision peut influencer la prise de décision clinique et limiter l'utilité du StatSensor comme outil de dépistage de l'IRC. Il est essentiel que les cliniciens soient conscients des limites de ces dispositifs et qu'ils appliquent ces connaissances à l'interprétation des résultats s'ils choisissent de les utiliser pour dépister ou surveiller l'IRC. ENREGISTREMENT DE L'ESSAI: Sans objet, il ne s'agissait pas d'un essai clinique.