Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Neurophysiol ; 119(8): 1909-1916, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18571984

RESUMO

OBJECTIVE: The current study evaluates the efficacy of a P300-based brain-computer interface (BCI) communication device for individuals with advanced ALS. METHODS: Participants attended to one cell of a N x N matrix while the N rows and N columns flashed randomly. Each cell of the matrix contained one character. Every flash of an attended character served as a rare event in an oddball sequence and elicited a P300 response. Classification coefficients derived using a stepwise linear discriminant function were applied to the data after each set of flashes. The character receiving the highest discriminant score was presented as feedback. RESULTS: In Phase I, six participants used a 6 x 6 matrix on 12 separate days with a mean rate of 1.2 selections/min and mean online and offline accuracies of 62% and 82%, respectively. In Phase II, four participants used either a 6 x 6 or a 7 x 7 matrix to produce novel and spontaneous statements with a mean online rate of 2.1 selections/min and online accuracy of 79%. The amplitude and latency of the P300 remained stable over 40 weeks. CONCLUSIONS: Participants could communicate with the P300-based BCI and performance was stable over many months. SIGNIFICANCE: BCIs could provide an alternative communication and control technology in the daily lives of people severely disabled by ALS.


Assuntos
Esclerose Lateral Amiotrófica/patologia , Esclerose Lateral Amiotrófica/fisiopatologia , Encéfalo/fisiopatologia , Potenciais Evocados P300/fisiologia , Interface Usuário-Computador , Adulto , Idoso , Análise Discriminante , Eletroencefalografia/métodos , Retroalimentação Psicológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reconhecimento Visual de Modelos/fisiologia , Estimulação Luminosa , Tempo de Reação
2.
J Neurosci Methods ; 203(1): 233-40, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-21963400

RESUMO

The goal of the current study is to find a suitable classifier for electroencephalogram (EEG) data derived from a new learning paradigm which aims at communication in paralysis. A reflexive semantic classical (Pavlovian) conditioning paradigm is explored as an alternative to the operant learning paradigms, currently used in most brain-computer interfaces (BCIs). Comparable with a lie-detection experiment, subjects are presented with true and false statements. The EEG activity following true and false statements was classified with the aim to separate covert 'yes' from covert 'no' responses. Four classification algorithms are compared for classifying off-line data collected from a group of 14 healthy participants: (i) stepwise linear discriminant analysis (SWLDA), (ii) shrinkage linear discriminant analysis (SLDA), (iii) linear support vector machine (LIN-SVM) and (iv) radial basis function kernel support vector machine (RBF-SVM). The results indicate that all classifiers perform at chance level when separating conditioned 'yes' from conditioned 'no' responses. However, single conditioned reactions could be successfully classified on a single-trial basis (single conditioned reaction against a baseline interval). All of the four investigated classification methods achieve comparable performance, however results with RBF-SVM show the highest single-trial classification accuracy of 68.8%. The results suggest that the proposed paradigm may allow affirmative and negative (disapproving negative) communication in a BCI experiment.


Assuntos
Encéfalo/fisiologia , Condicionamento Clássico/fisiologia , Eletroencefalografia , Semântica , Máquina de Vetores de Suporte , Interface Usuário-Computador , Adulto , Algoritmos , Análise Discriminante , Feminino , Humanos , Masculino , Adulto Jovem
3.
Psychophysiology ; 46(3): 617-25, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19170946

RESUMO

This study was designed to develop and test an auditory event-related potential (ERP) based spelling system for a brain-computer interface (BCI) and to compare user's performance between the auditory and visual modality. The spelling system, where letters in a matrix were coded with acoustically presented numbers, was tested on a group of healthy volunteers. The results were compared with a visual spelling system. Nine of the 13 participants presented with the auditory ERP spelling system scored above a predefined criterion level control for communication. Compared to the visual spelling system, users' performance was lower and the peak latencies of the auditorily evoked ERPs were delayed. It was concluded that auditorily evoked ERPs from the majority of the users could be reliably classified. High accuracies were achieved in these users, rendering item selection with a BCI based on auditory stimulation feasible for communication.


Assuntos
Encéfalo/fisiologia , Potenciais Evocados P300/fisiologia , Interface Usuário-Computador , Estimulação Acústica , Adolescente , Adulto , Eletroencefalografia , Feminino , Humanos , Idioma , Masculino , Estimulação Luminosa , Desempenho Psicomotor/fisiologia , Adulto Jovem
4.
Physiol Meas ; 30(10): 1051-60, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19738317

RESUMO

We propose a multi-stage approach using Wavelet and Hilbert transforms to identify uterine contraction bursts in magnetomyogram (MMG) signals measured using a 151 magnetic sensor array. In the first stage, we decompose the MMG signals by wavelet analysis into multilevel approximate and detail coefficients. In each level, the signals are reconstructed using the detail coefficients followed by the computation of the Hilbert transform. The Hilbert amplitude of the reconstructed signals from different frequency bands (0.1-1 Hz) is summed up over all the sensors to increase the signal-to-noise ratio. Using a novel clustering technique, affinity propagation, the contractile bursts are distinguished from the noise level. The method is applied on simulated MMG data, using a simple stochastic model to determine its robustness and to seven MMG datasets.


Assuntos
Eletromiografia/normas , Magnetismo/normas , Contração Uterina/fisiologia , Eletromiografia/métodos , Feminino , Humanos , Magnetismo/métodos , Miografia/métodos , Miografia/normas , Gravidez
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa