Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Manipulative Physiol Ther ; 43(6): 635-645, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32900546

RESUMO

OBJECTIVE: Advances in mobile technology have led to the development of smartphones, whose applications present numerous utilities, such as the analysis of human movement based on inertial sensors. The purpose of this review was to investigate validity and reliability of smartphones in assessing the kinematics of the human spine. METHODS: A systematic search was performed on MEDLINE, Embase, Scopus, and LILACS databases, as well as manual searches. The included studies evaluated psychometric properties of smartphones in assessing kinematic variables of the spine (range of motion [ROM], speed, and acceleration). Two independent reviewers performed the selection, reading, data extraction, and risk of bias assessment of the studies. RESULTS: Of the 2651 articles initially found, 9 were included and had their results for ROM analyzed. The meta-analyses for validity showed very high correlation coefficients in the evaluation of cervical flexion, extension, and lateral flexion; high ones in the evaluation of cervical rotation; and also high ones for intrarater and interrater reproducibility of all cervical movements. The meta-analyses for interrater reproducibility showed high correlation coefficients in the evaluation of lumbar flexion and very high ones for intrarater reproducibility. CONCLUSION: The use of smartphones for assessing the ROM of cervical flexion, extension, and lateral flexion and lumbar flexion is feasible. Their use for assessing thoracic rotation is potentially viable, but further validation studies are still needed to ensure a safe use. There is a lack of validation studies that evaluate the applicability of this device in assessing other kinematic characteristics, such as speed and acceleration.


Assuntos
Fenômenos Biomecânicos/fisiologia , Guias como Assunto , Movimento/fisiologia , Amplitude de Movimento Articular/fisiologia , Smartphone/normas , Coluna Vertebral/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
2.
J Manipulative Physiol Ther ; 43(2): 93-99, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32660713

RESUMO

OBJECTIVE: To analyze the concurrent validity of the Digital Image-based Postural Assessment (DIPA) method for identifying the magnitude and classification of thoracic kyphosis in adults. METHODOLOGY: On the same day and in the same place, thoracic kyphosis was assessed in 68 adults using 2 methods: the DIPA software protocol and radiography. The DIPA software provided angular values of thoracic kyphosis based on trigonometric relations, while with the radiograph, the curvature was calculated using the Cobb method. The following tests were applied in the statistical analysis: Pearson's correlation, Bland-Altman's graphic representation, root mean square error, and receiver operating characteristic (ROC) curve; α = 0.05. The reference angular values for the standard thoracic posture used in DIPA were determined with the ROC curve based on the Cobb angles. RESULTS: The correlation between the angles obtained for thoracic kyphosis using the DIPA and Cobb methods was found to be high (r = 0.813, P < .001), and the accuracy was ±4°. According to Bland-Altman's representation, the magnitudes provided by the DIPA software were in agreement with those of the Cobb method. In reference values for determining the standard posture of the thoracic spine, the ROC curve indicated good accuracy in diagnosing a decrease in thoracic kyphosis (with a value of 33.9°) and excellent accuracy in diagnosing thoracic hyperkyphosis (with a value 39.9°) when using DIPA. CONCLUSION: The DIPA postural assessment method is valid in the sagittal plane for identifying the magnitude of thoracic kyphosis in adults. Furthermore, it is accurate in diagnosing alterations in thoracic kyphosis.


Assuntos
Cifose/diagnóstico por imagem , Postura/fisiologia , Vértebras Torácicas/diagnóstico por imagem , Adulto , Estudos Transversais , Interpretação Estatística de Dados , Feminino , Humanos , Masculino , Radiografia , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem
3.
J Manipulative Physiol Ther ; 40(9): 700-707, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29229061

RESUMO

OBJECTIVE: The purpose of this study was to assess a radiographic method for spinal curvature evaluation in children, based on spinous processes, and identify its normality limits. METHODS: The sample consisted of 90 radiographic examinations of the spines of children in the sagittal plane. Thoracic and lumbar curvatures were evaluated using angular (apex angle [AA]) and linear (sagittal arrow [SA]) measurements based on the spinous processes. The same curvatures were also evaluated using the Cobb angle (CA) method, which is considered the gold standard. For concurrent validity (AA vs CA), Pearson's product-moment correlation coefficient, root-mean-square error, Pitman- Morgan test, and Bland-Altman analysis were used. For reproducibility (AA, SA, and CA), the intraclass correlation coefficient, standard error of measurement, and minimal detectable change measurements were used. RESULTS: A significant correlation was found between CA and AA measurements, as was a low root-mean-square error. The mean difference between the measurements was 0° for thoracic and lumbar curvatures, and the mean standard deviations of the differences were ±5.9° and 6.9°, respectively. The intraclass correlation coefficients of AA and SA were similar to or higher than the gold standard (CA). The standard error of measurement and minimal detectable change of the AA were always lower than the CA. CONCLUSION: This study determined the concurrent validity, as well as intra- and interrater reproducibility, of the radiographic measurements of kyphosis and lordosis in children.


Assuntos
Processamento de Imagem Assistida por Computador , Cifose/diagnóstico por imagem , Lordose/diagnóstico por imagem , Adolescente , Fatores Etários , Brasil , Criança , Pré-Escolar , Estudos de Coortes , Diagnóstico Precoce , Feminino , Humanos , Vértebras Lombares/anormalidades , Vértebras Lombares/diagnóstico por imagem , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores Sexuais , Curvaturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/anormalidades , Vértebras Torácicas/diagnóstico por imagem
4.
J Manipulative Physiol Ther ; 40(9): 692-699, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29229060

RESUMO

OBJECTIVE: The purpose of this study was to develop, assess the reliability of, and validate prediction equations that estimate the sagittal curves of the spine from the skin surface. METHODS: Forty digital panoramic radiographs were used to develop the prediction equation, and 59 radiographs were used to assess reliability and validate the equations. For evaluation of the thoracic and lumbar curves, anatomical reference points were marked on the vertebral body, spinous process, and skin surface at the C6, C7, T2, T4, T6, T8, T10, T12, L2, L4, and S2 vertebrae. Three third-degree polynomials were obtained, estimated with the least squares method: inner curves from the centroid of the vertebral bodies and from the apex of the spinous processes and external curve from the skin surface. The magnitude of the curves of each region was estimated based on the angle between tangent lines at several vertebral levels. Prediction equations were obtained (simple linear regression) for the vertebral levels that had the best correlation between the inner and surface curves. The validation of the prediction equations was confirmed using Pearson's correlation (r), Student t test, and root mean square error. The reliability of the method was confirmed using the intraclass correlation coefficient, standard error of measurement, and minimal detectable change (α = 0.05). RESULTS: The best correlations were obtained between the T4-T12 (thoracic) and T10-S2 (lumbar) levels (r > 0.85). For the intrarater and interrater reliability, the correlation was higher than 0.965 and higher than 0.896, respectively. There was a significant and strong correlation between estimated and actual values for the thoracic and lumbar curves, which was confirmed by the t-test results and by the root mean square error inferior to 1°. CONCLUSION: Prediction equations can precisely and accurately estimate the angles of the internal sagittal curves of the spine from the skin surface.


Assuntos
Postura/fisiologia , Radiografia Panorâmica/métodos , Curvaturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/fisiologia , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiologia , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos de Amostragem , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/fisiologia
5.
J Chiropr Med ; 18(4): 270-277, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32952472

RESUMO

OBJECTIVE: This prospective study aimed to assess the concurrent validity and diagnostic accuracy of a mathematical procedure for measurement of the spinal inclination angle, analogous to the Cobb angle, by means of photogrammetry. METHODS: Sixty-one subjects (aged 7 to 18 years), male and female, underwent radiographic (Cobb angle) and photogrammetric (DIPA [Digital Image-based Postural Assessment] angle) evaluations. The measurement of spinal inclination angle obtained through photogrammetry followed the Digital Image-Based Postural Assessment software protocol. Concurrent validity was appraised using Spearman rank correlation, the coefficient of determination, the root-mean-square error, Bland-Altman plot analysis, and receiver operating characteristic analysis, adopting P ≤ .05. RESULTS: The analyses were divided according to the topography of the scoliotic curve (thoracic, lumbar, or thoracolumbar). The correlations were excellent (from 0.72 to 0.81) and significant for all the regions of the spine, and the coefficients of determination ranged between 0.75 and 0.88. The root-mean-square error was between 5° and 11°, and the mean difference was very close to 0. The area under the curve was excellent and significant, ranging between 95% and 99%. CONCLUSION: The mathematical procedure presented is valid to evaluate the spinal inclination angle in photogrammetry, analogous to the Cobb angle in radiography.

6.
Rev Bras Fisioter ; 15(6): 511-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22045292

RESUMO

BACKGROUND: The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures. OBJECTIVE: To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays. METHODS: 52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA. RESULTS: There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA. CONCLUSION: It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.


Assuntos
Cifose/patologia , Lordose/patologia , Vértebras Lombares/anormalidades , Exame Físico/instrumentação , Vértebras Torácicas/anormalidades , Estudos Transversais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
7.
Braz. j. phys. ther. (Impr.) ; 15(6): 511-517, Nov.-Dec. 2011. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-611333

RESUMO

BACKGROUND: The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures. OBJECTIVE: To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays. METHODS: 52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA. RESULTS: There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA. CONCLUSION: It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.


CONTEXTUALIZAÇÃO: A necessidade de identificação precoce de alterações posturais, sem expor as pessoas à radiação constante, tem estimulado a construção de instrumentos para medir as curvaturas da coluna vertebral. OBJETIVO: Verificar a validade, repetibilidade e reprodutibilidade dos ângulos das curvaturas sagitais da coluna vertebral, obtidos por meio de um arcômetro adaptado, comparando-os com os ângulos de Cobb (AC) das respectivas curvaturas, obtidos por meio de exames radiográficos. MÉTODOS: Cinquenta e dois indivíduos foram submetidos a dois procedimentos destinados a avaliar as curvaturas torácica e lombar: (1) exame de raios-X, a partir do qual os AC de ambas as curvaturas foram obtidos e (2) medição dos ângulos das curvaturas com o arcômetro (AA). Dois avaliadores coletaram os dados usando o arcômetro com as hastes sobre os processos espinhosos T1, T12, L1 e L5, de modo a permitir medidas que, com auxílio de trigonometria, forneceram os AA. RESULTADOS: Encontrou-se correlação muito forte e significativa entre AA e AC (r=0,94, p<0,01), sem diferença significativa (p=0,32) para a curvatura torácica, enquanto, para a curvatura lombar, encontrou-se uma forte e significativa correlação (r=0,71, p<0,01) entre AA e AC, sem diferença significativa (p=0,30). Existe uma correlação muito forte intra-avaliador e inter-avaliador nos AA. CONCLUSÃO: O arcômetro permitiu quantificar as curvaturas torácica e lombar, podendo-se considerar as medições válidas, fidedignas e objetivas para uso na avaliação de curvaturas da coluna vertebral no plano sagital.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cifose/patologia , Lordose/patologia , Vértebras Lombares/anormalidades , Exame Físico/instrumentação , Vértebras Torácicas/anormalidades , Estudos Transversais , Desenho de Equipamento , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa