Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Paediatr Anaesth ; 34(2): 153-159, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37925608

RESUMO

BACKGROUND AND AIMS: Virtual reality has been shown to be an effective non-pharmacological intervention for reducing anxiety of pediatric patients. A newer immersive technology, that of augmented reality, offers some practical advantages over virtual reality, and also seems to show beneficial effects on anxiety. The main objective of this study was to determine whether augmented reality could reduce preoperative anxiety in pediatric patients undergoing elective day surgeries. A secondary outcome was to document the level of satisfaction from pediatric patients toward augmented reality intervention. METHODS: Children and adolescents aged between 5 and 17 years old scheduled for elective day surgery under general anesthesia were randomly divided into two groups. Patients in the control group received standard care, whereas patients in the augmented reality group were accompanied by two virtual characters who taught them relaxation techniques and provided emotional and informational support. Anxiety was measured at the time of admission and at the time of induction using the short version of the modified Yale Preoperative Anxiety Scale. RESULTS: The analysis included 37 pediatric patients in the augmented reality group and 64 in the control group. Anxiety scores were statistically significantly lower in the augmented reality group than those in the control group at the time of admission (median difference [95% CI]: 6.3 [0-10.4], p = .01), while no difference was observed between groups at the time of induction (median difference [95% CI]: -4.2 [-5.2-4.2], p = .58). Most patients in the augmented reality group wished to wear the glasses again and reported to be very satisfied with the intervention. CONCLUSION: To our knowledge, this study is the first large randomized controlled trial to provide empirical evidence of reduction in anxiety for children and adolescents using augmented reality prior to induction of general anesthesia.


Assuntos
Realidade Aumentada , Criança , Humanos , Adolescente , Recém-Nascido , Ansiedade/prevenção & controle , Ansiedade/psicologia , Procedimentos Cirúrgicos Eletivos , Anestesia Geral/métodos , Procedimentos Cirúrgicos Ambulatórios
2.
J Vasc Surg ; 76(1): 165-173, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35351603

RESUMO

OBJECTIVE: The primary objective of this study is to describe and illustrate the technique of ultrasound-guided percutaneous proximal axillary artery (PAA) access, and secondarily to evaluate the versatility and safety of this approach in peripheral, visceral, and aortic endovascular interventions. METHODS: This is a single-center retrospective review of all peripheral, visceral, and aortic endovascular cases using percutaneous PAA access from February 2019 to March 2021 compared with a sample of an equivalent number of consecutive cases completed via percutaneous common femoral artery (CFA) access during the same time period. Access entry success, minor and major access site complications within 30 days, major adverse events within 30 days, demographics, and procedural details were analyzed using standard statistical analyses. RESULTS: A total of 115 accesses-59 PAA and 56 CFA-were reviewed during the study period. Group demographics were not significantly different. Access entry success was achieved in 58 (98.3%) and 56 (100%) of PAA and CFA accesses, respectively, with no statistically significant difference. There were no significant differences in minor access-site complications (13.6% vs 5.4%; P = .21) major access site complications (3.4% vs 7.1%; P = .43), or major adverse events (6.8% vs 5.4%). between the PAA and CFA groups. With respect to versatility, PAA cases had a significantly greater mean number of vessels intervened on per procedure compared with CFA access (2.59 ± 1.31 vs 1.95 ± 0.98; P < .01). A wide range of target vessels were intervened on in both groups. PAA cases had significantly more bilateral lower leg interventions (28.8% vs 12.5%; P = .04). PAA access had a significantly longer mean procedure time (103.2 minutes vs 58.63 minutes; P < .001) and fluoroscopy time (18.21 minutes vs 12.87 minutes; P = .02). CONCLUSIONS: The PAA is a feasible, versatile, and safe percutaneous access option for endovascular intervention. The in-line trajectory from this site facilitates visceral, renal, aortic, and bilateral lower extremity interventions with ease. Outcomes, complications, and major adverse events are similar to those of conventional CFA access in the short term.


Assuntos
Cateterismo Periférico , Procedimentos Endovasculares , Artéria Axilar/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Artéria Femoral/diagnóstico por imagem , Humanos , Extremidade Inferior , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
3.
BMC Public Health ; 22(1): 1764, 2022 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-36115946

RESUMO

BACKGROUND: Body image variables such as body size perception (BSP) and body size dissatisfaction (BSD) can influence health-related behaviors. However, few studies have investigated these body image variables in adolescent girls participating in a physical activity intervention. Therefore, the study objectives were to examine the 1) associations between health-related behaviors (physical activity, screen-time, eating habits and sleep duration) and BSP and BSD among girls participating in FitSpirit, a physical activity intervention for girls; and 2) influence of weight control practices on the association between health-related behaviors and BSP and BSD. METHODS: This cross-sectional study assessed a sample of 545 adolescent girls (mean age: 15.0±1.5 years) from 240 schools. Body mass index, health-related behaviors, perceived actual body size and desired body size variables were self-reported and collected via an online questionnaire at the end of the FitSpirit intervention. A negative BSP score [perceived actual body size - calculated BMI z-score] indicates an underestimation of body size. A positive BSD score [perceived actual body size - desired body size] indicates a desire to reduce body size. A multiple linear regression analysis examined the effects of age, zBMI and health behaviors on BSP and BSD. A second multiple linear regression analysis examined the independent associations between BSP and BSD by weight control practice. The linear relationships between BSP and BSD were evaluated with Pearson's correlations. RESULTS: Underestimation and dissatisfaction of body size are more prevalent in participants living with overweight/obesity. Screen-time and sleep duration were independently associated with BSP score (Beta=0.02; P<0.05 and Beta=-0.07; P<0.05, respectively), whereas only screen-time was associated with the BSD score (Beta=0.07; P<0.001). Physical activity was independently associated with the BSP score only in participants trying to control (maintain) their weight (Beta=-0.18; P<0.05). CONCLUSIONS: Body size overestimation and dissatisfaction are associated with health-related behaviors, specifically with more screen-time and less optimal sleeping habits. Physical activity level does not appear to be associated with body image in girls engaged in a physical activity intervention and who want to lose or gain weight. Health promotion interventions could include screen-time and sleep components as they may influence body image.


Assuntos
Imagem Corporal , Comportamentos Relacionados com a Saúde , Adolescente , Índice de Massa Corporal , Estudos Transversais , Feminino , Humanos , Sobrepeso
4.
Catheter Cardiovasc Interv ; 98(7): E985-E989, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34586756

RESUMO

Thoracic pseudoaneurysm in the ascending aorta is an uncommon condition associated with significant risk of morbidity and mortality. Treatment is recommended in all cases regardless of symptoms as the mortality rate if left untreated has been documented to be as high as 61%. The current standard of care for managing these lesions is open surgical repair. However, this is associated with significant morbidity. In-hospital mortality reported for patients undergoing surgical repair of an ascending aortic pseudoaneurysm ranges from 6.7% to 41%. When anatomically suitable, a less invasive approach using amplatzer vascular plug or septal occluder is an attractive approach. We present a case report of repair of a post-surgical ascending aortic false aneurysm using an amplatzer septal occluder with an Oscor ™ steerable guiding sheath; a novel approach to increase platform stability when engaging an aneurysm neck. Endovascular occluder deployment for closure of aortic false aneurysms remains a relatively novel technique. It is limited by the requirement to develop a stable endovascular platform to deliver the device and avoid system prolapse, particularly when accessing challenging lesions on the inner aortic curvature. We present the first case to utilize a steerable guiding sheath system to improve system stability and facilitate successful device delivery. Given the significant morbidity associated with open repair of these lesions we hope this will further expand the range of lesions viewed as appropriate for endovascular repair.


Assuntos
Falso Aneurisma , Aneurisma Aórtico , Dispositivo para Oclusão Septal , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Humanos , Resultado do Tratamento
5.
J Vasc Surg ; 71(1): 158-172.e1, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31303475

RESUMO

OBJECTIVE: Previous investigations have suggested that a minimum venous outflow diameter (MVOD) and perianastomotic arterial diameter are associated with successful autogenous arteriovenous maturation and patency. The goal of this study was to determine anatomic and clinical variables that may influence access patency to guide optimal autogenous access configuration selection. METHODS: Accesses created from 2010 to 2016 were analyzed from data entered into a prospective database. Preprocedure duplex ultrasound mapping data of artery and tourniquet-derived vein diameters and demographic and clinical variables were collected. Survival-based cut point analysis was used to determine anatomic parameters most predictive of access failure. Kaplan-Meier and Cox proportional hazards analyses were used to assess patencies and maturation and to identify independent predictors of access failure. RESULTS: A total of 356 first-time autogenous accesses were created (median follow-up, 20 months; range, 0-73 months). Of these, 202 (56.7%) were radiocephalic and 154 (43.3%) were brachiocephalic. Maturation failure at end of follow-up for arteriovenous accesses was 26% ± 3% for radiocephalic accesses and 15% ± 3% for brachiocephalic accesses (P < .001). For radiocephalic accesses, MVOD <3.0 mm and radial artery diameter <2.1 mm independently predicted access maturation failure (MVOD <3.0 mm: hazard ratio [HR], 2.62 [95% confidence interval (CI), 1.27-5.39; P = .009]; radial artery diameter <2.1 mm: HR, 2.20 [95% CI, 1.20-4.05; P = .011]) and secondary patency loss (MVOD <3.0 mm: HR, 2.21 [95% CI, 1.24-3.96; P = .007]; radial artery diameter <2.1 mm: HR, 2.11 [95% CI, 1.26-3.63; P = .004]). A combination of radial artery diameter <2.1 mm and MVOD <3.0 mm most strongly predicted maturation failure (HR, 4.24; 95% CI, 1.71-10.49; P = .002) and loss of secondary patency (HR, 4.03; 95% CI, 1.88-8.64; P < .001). Only diabetes mellitus (HR, 2.24; P = .012) predicted secondary patency loss. For brachiocephalic accesses, MVOD <3.4 mm (HR, 2.12; 95% CI, 1.02-4.46; P = .043) was found to independently predict secondary patency loss in addition to previous ipsilateral (HR, 2.37; P = .038) and bilateral (HR, 4.00; P = .015) tunneled hemodialysis catheters. Brachial artery diameter was not associated with either access maturation or patency. CONCLUSIONS: Artery and tourniquet-derived vein diameters independently predict radiocephalic access patency and functional outcomes. A combination of a radial artery diameter <2.1 mm and MVOD <3.0 mm best predicts maturation failure and patency loss for radiocephalic access. MVOD <3.4 mm was associated with increased loss of brachiocephalic access secondary patency, but MVOD was not associated with maturation.


Assuntos
Derivação Arteriovenosa Cirúrgica , Artéria Braquial/cirurgia , Artéria Radial/cirurgia , Diálise Renal , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular , Veias/cirurgia , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiopatologia , Bases de Dados Factuais , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Artéria Radial/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Torniquetes , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Veias/diagnóstico por imagem , Veias/fisiopatologia
6.
Ann Vasc Surg ; 61: 124-133, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31344465

RESUMO

BACKGROUND: Adjuncts for early detection and treatment of spinal cord ischemia (SCI) in thoracic aortic surgery are supported by robust clinical experience in open repair. The utility of cerebrospinal fluid (CSF) drainage and neurophysiologic monitoring (NPM) in thoracic endovascular aortic repair (TEVAR) is less clear. The purpose of this investigation is to determine the influence of a selective institutional spinal cord protection protocol using prophylactic NPM and CSF on outcomes for standard TEVAR. METHODS: Patients undergoing standard TEVAR entered into a prospectively maintained database from a single institution from 2007 to 2016 were retrospectively reviewed. Preoperative characteristics, aneurysm extent, and etiology were reviewed. Utilization of CSF drains including volume of fluid removed, duration of drainage, and catheter-related complications were collected. NPM data were reviewed to determine the influence on intraoperative management. Exact logistic regression was used to identify independent predictors of SCI. RESULTS: Of 223 patients undergoing TEVAR, 130 met inclusion criteria for the study. CSF drains were used in 71 patients (54.6%), and 56 of 130 (43%) had NPM. SCI occurred in 7 patients (5.4%), of whom 5 had partial or complete recovery. Median time to symptoms of SCI was delayed in all cases (median 52 hr, range 8-312), and none of the 4 of 7 patients with adjunct NPM demonstrated intraoperative changes. Intraoperative changes in NPM occurred in 26 (46%), and represented unilateral leg ischemia in all but 2 cases. In both patients, changes consistent with SCI were associated with intraoperative hypotension and resolved with blood pressure augmentation. Neither patient developed postoperative SCI. Median length of stay (22 vs. 9 days, P = 0.012), operative room time (262 vs. 209, P = 0.040), and perioperative mortality (28.6% vs. 4.1%, P = 0.046) were significantly higher for patients with SCI versus those without. Length of aortic coverage was found to be the sole independent predictor of SCI (odds ratio 8.2, P = 0.026). Complications related to CSF drainage occurred in 4 patients (5.6%) with major complications occurring in 2 patients (2.8%), including 1 with an intrathecal hematoma and permanent bilateral paraparesis. CONCLUSIONS: Selective use of prophylactic CSF drainage in TEVAR was associated with moderate risk and questionable benefit. The use of neurophysiological monitoring allowed for early detection and treatment of spinal ischemia, but its utility is limited by logistical factors and to the minority of patients with intraoperative spinal ischemic events.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Monitorização Neurofisiológica Intraoperatória , Isquemia do Cordão Espinal/prevenção & controle , Punção Espinal , Aneurisma da Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Implante de Prótese Vascular/mortalidade , Colúmbia Britânica , Bases de Dados Factuais , Diagnóstico Precoce , Procedimentos Endovasculares/mortalidade , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Punção Espinal/efeitos adversos , Punção Espinal/mortalidade , Fatores de Tempo , Resultado do Tratamento
7.
J Vasc Surg ; 67(5): 1491-1500, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29224945

RESUMO

OBJECTIVE: Current Kidney Disease Outcomes Quality Initiative guidelines do not incorporate age in determining autogenous arteriovenous hemodialysis access placement, and the optimal initial configuration in elderly patients remains controversial. We compared patency, maturation, survival, and complications between several age cohorts (<65 years, 65-79 years, >80 years) to determine whether protocols should be modified to account for advanced age. METHODS: All patients at two teaching hospitals undergoing a first autogenous arteriovenous access creation in either arm between 2007 and 2013 were retrospectively analyzed from a prospectively maintained database. Kaplan-Meier survival and Cox hazards models were used to compare access patency and risk factors for failure. RESULTS: There were 941 autogenous arteriovenous accesses (median follow-up, 23 months; range, 0-89 months) eligible for inclusion; 152 (15.3%) accesses were created in those >80 years, 397 (42.2%) in those 65 to 79 years, and 392 (41.8%) in those <65 years. Primary patencies in patients >80 years, 65 to 79 years, and <65 years were 40% ± 4%, 38% ± 3%, and 51% ± 3% at 12 months and 12% ± 5%, 13% ± 3%, and 27% ± 3% at 36 months (P < .001). Primary assisted patencies were 72% ± 4%, 70% ± 2%, and 78% ± 2% at 12 months and 52% ± 5%, 52% ± 3%, and 67% ± 3% at 36 months (P < .001). Secondary patencies were 72% ± 4%, 71% ± 2%, and 79% ± 2% at 12 months and 54% ± 5%, 55% ± 3%, and 72% ± 3% at 36 months (P < .001). Radiocephalic patencies were lowest among older cohorts; in those >80 years, 65 to 79 years, and <65 years, they were 65% ± 7%, 67% ± 4%, and 77% ± 3% at 12 months and 41% ± 8%, 51% ± 5%, and 68% ± 4% at 36 months (P = .019). Secondary brachiocephalic access patencies in these cohorts were 78% ± 5%, 80% ± 3%, and 82% ± 3% at 12 months and 68% ± 7%, 66% ± 5%, and 77% ± 4% at 36 months (P = .206). Both the age groups 65 to 79 years and >80 years demonstrated superior brachiocephalic vs radiocephalic secondary patencies (P = .048 and P = .015, respectively); however, no differences between configuration and secondary patency were observed within the cohort <65 years. Radiocephalic access maturation failure at 12 and 24 months was 25% ± 3% and 29% ± 4% in those <65 years, 32% ± 3% and 39% ± 4% in those 65 to 79 years, and 40% ± 7% and 48% ± 8% in those >80 years (P = .006). Brachiocephalic access maturation failures were 17% ± 3% and 20% ± 3% at 12 and 24 months in those <65 years, 21% ± 3% and 25% ± 4% in those 65 to 79 years, and 18% ± 5% and 21% ± 5% in those >80 years (P = .740). On multivariate analysis, coronary disease, female sex, previous ipsilateral or bilateral catheters, radiocephalic configuration, and age >65 years were associated with secondary patency loss. CONCLUSIONS: Patients aged 65 to 79 years and >80 years had inferior primary, primary assisted, and secondary patency and maturation compared with those <65 years. When stratified by configuration, radiocephalic accesses demonstrated lower patency and maturation compared with brachiocephalic accesses for patients aged 65 to 79 years and >80 years and were an independent predictor of secondary patency loss.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Diálise Renal , Insuficiência Renal/terapia , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Colúmbia Britânica , Distribuição de Qui-Quadrado , Bases de Dados Factuais , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Insuficiência Renal/diagnóstico , Insuficiência Renal/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Ann Vasc Surg ; 29(8): 1660.e5-10, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26315802

RESUMO

BACKGROUND: The advent of branched and fenestrated aortic endografts has facilitated the treatment of increasingly complex aortic pathology. The management of complications and endoleaks involving the branches and fenestrations of these grafts represents an increasingly significant clinical and technical challenge. METHODS: A 79-year-old woman developed a rare type IIIb endoleak from a tear in the graft fabric immediately posterior to the celiac axis branch 3 years after the placement of an off-the-shelf branched endograft for a type II thoracoabdominal aortic aneurysm. The patient presented urgently with abdominal pain and a maximal aneurysm diameter of 15.3 cm. RESULTS: The operative plan was to create a chimney graft completely within the original branched endograft to cover the defect and maintain celiac branch flow. The celiac trunk was accessed from a left axillary approach and access for the main endograft body was achieved via the left femoral artery. Two balloon-expandable covered stents were deployed from the celiac branch extending into the main endograft as a chimney and molded to 2 aortic extension cuffs to cover the fabric defect. The resultant configuration was a modified-sandwich graft within the original stent graft and resulted in successful exclusion of the endoleak. Postoperative imaging at 1, 6, and 12 months has demonstrated continued patency of the celiac trunk, no further endoleak, and a 16-mm reduction in aneurysm size. CONCLUSIONS: The chimney technique was successfully applied as an endovascular option to salvage a multibranched endograft with a significant and anatomically unfavorable defect. Careful follow-up and additional clinical study are required to clarify the role of off-the-shelf solutions in complex endoleak management.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Procedimentos Endovasculares , Stents/efeitos adversos , Idoso , Endoleak/diagnóstico , Endoleak/etiologia , Feminino , Humanos , Reoperação
9.
Ann Vasc Surg ; 28(4): 1052-61, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24556317

RESUMO

Magnetic resonance angiography is a technique used to image both central and peripheral arteries using contrast and noncontrast techniques. These techniques are similar in that a bright signal, which appears white within blood vessels, is generated and the background tissues, veins, and stationary tissues are dark. This allows for assessment of anatomy and vascular disease. Extracellular gadolinium-based contrast agents allow for excellent visualization of both central and peripheral arteries. Acquiring images during first pass is required for high-contrast images within arteries, thereby limiting contamination with contrast enhancement of veins and soft tissue. Contrast-enhanced techniques using time-resolved angiography and blood pool contrast agents minimize this temporal limitation. Noncontrast techniques eliminate the uncommon but potentially fatal complications associated with gadolinium contrast agents, such as nephrogenic systemic fibrosis. These techniques including phase contrast and time-of-flight sequences have inferior contrast resolution compared with contrast-enhanced techniques and are susceptible to artifacts, which can limit interpretation. The advantage, however, is the ability to assess vascular disease in patients with severe renal failure without the added risks of gadolinium contrast media. The aim of this review is to outline the different techniques available for imaging both the arterial and venous systems, their advantages and disadvantages, and the indications in vascular disease.


Assuntos
Angiografia por Ressonância Magnética , Doenças Vasculares/diagnóstico , Meios de Contraste/efeitos adversos , Humanos , Angiografia por Ressonância Magnética/efeitos adversos , Angiografia por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença
10.
Mar Pollut Bull ; 202: 116387, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38663346

RESUMO

The concentrations of 11 heavy metals in sediments from Lake Edku, Egypt were determined using LA-ICP-MS. The average concentrations of elements occurred in the order of Fe > V > Cr > Zn > Ni > Cu > Co > Pb > As > Sn > Mo with respective values of 4.67 %, 104.8, 77.9, 76.6, 59.2, 52, 27.8, 19.8, 4.14, 2.24, and 1.45 µg/g. Several pollution indices were used to evaluate individual and cumulative contamination levels. All HMs were found to be in the deficiency to minimal enrichment range based on the enrichment factor. The contamination factor indicated low contamination levels of Cr and As, low to moderate contamination levels of Fe, Ni, Zn, Mo, Sn, and Pb, and moderate contamination levels of Co and Cu. The pollution load index and contamination degree indicated the sediments to be polluted and moderately polluted, respectively.


Assuntos
Monitoramento Ambiental , Sedimentos Geológicos , Lagos , Espectrometria de Massas , Metais Pesados , Poluentes Químicos da Água , Egito , Lagos/química , Sedimentos Geológicos/química , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Metais Pesados/análise
11.
JVS Vasc Sci ; 4: 100127, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37928834

RESUMO

Objective: Case reports, tissue pathology, and autopsies have suggested that the hydrophilic polymer coating designed to improve endovascular deliverability and minimize vessel trauma can embolize and be associated with adverse outcomes such as ischemia, infarction, and death. This study sought to determine whether hydrophilic polymers shed off commercially available sheaths in a controlled in vitro environment, with the hypothesis that significant differences between coated and uncoated (control) sheaths would be found. Methods: Six sheaths from each manufacturer, including Zenith Alpha abdominal endovascular stent grafts (Cook Medical), DrySeal sheaths (W.L. Gore & Associates), and Sentrant Introducer sheaths (Medtronic), were tested in an in vitro environment. Noncoated Check-Flo performer introducer sheaths (Cook Medical) were used as controls. Each test circuit ran for 150 minutes at an output of 3 L/min, the circuit was then drained and the fluid collected. Quantitative analysis included weighing the dried filter paper and using particle size light scattering to quantify the particle size and count. Attenuated total reflectance spectroscopy was also used. Results: Each of the three coated sheaths had significantly greater shedding compared with the control sheaths. The Cook Zenith alpha sheath had significantly more residue weight (2.87 ± 0.52 mg/L) than the Gore DrySeal (1.07 ± 0.06 mg/L) and Medtronic Sentrant introducer (0.98 ± 0.14 mg/L) sheaths. The average particle size was not significantly different between the coated and uncoated (control) sheaths. Attenuated total reflectance spectroscopy identified sheath particulate in the Cook Zenith Alpha and Medtronic Sentrant samples. Conclusions: Polymer embolization was present and significantly greater in all three commercially available hydrophilic sheaths compared with the control group. Further investigation is needed into the clinical significance of these findings.

12.
JMIR Form Res ; 6(12): e37885, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36542432

RESUMO

BACKGROUND: Wearable devices collect physiological and behavioral data that have the potential to identify individuals at risk of declining mental health and well-being. Past research has mainly focused on assessing the accuracy and the agreement of heart rate (HR) measurement of wearables under different physical exercise conditions. However, the capacity of wearables to sense physiological changes, assessed by increasing HR, caused by a stressful event has not been thoroughly studied. OBJECTIVE: This study followed 3 objectives: (1) to test the ability of a wearable device (Fitbit Versa 2) to sense an increase in HR upon induction of psychological stress in the laboratory; (2) to assess the accuracy of the wearable device to capture short-term HR variations caused by psychological stress compared to a gold-standard electrocardiogram (ECG) measure (Biopac); and (3) to quantify the degree of agreement between the wearable device and the gold-standard ECG measure across different experimental conditions. METHODS: Participants underwent the Trier Social Stress Test protocol, which consists of an oral phase, an arithmetic stress phase, an anticipation phase, and 2 relaxation phases (at the beginning and the end). During the stress protocol, the participants wore a Fitbit Versa 2 and were also connected to a Biopac. A mixed-effect modeling approach was used (1) to assess the effect of experimental conditions on HR, (2) to estimate several metrics of accuracy, and (3) to assess the agreement: the Bland-Altman limits of agreement (LoA), the concordance correlation coefficient, the coverage probability, the total deviation index, and the coefficient of an individual agreement. Mean absolute error and mean absolute percent error were calculated as accuracy indices. RESULTS: A total of 34 university students were recruited for this study (64% of participants were female with a mean age of 26.8 years, SD 8.3). Overall, the results showed significant HR variations across experimental phases. Post hoc tests revealed significant pairwise differences for all phases. Accuracy analyses revealed acceptable accuracy according to the analyzed metrics of accuracy for the Fitbit Versa 2 to capture the short-term variations in psychological stress levels. However, poor indices of agreement between the Fitbit Versa 2 and the Biopac were found. CONCLUSIONS: Overall, the results support the use of the Fitbit Versa 2 to capture short-term stress variations. The Fitbit device showed acceptable levels of accuracy but poor agreement with an ECG gold standard. Greater inaccuracy and smaller agreement were found for stressful experimental conditions that induced a higher HR. Fitbit devices can be used in research to measure HR variations caused by stress, although they cannot replace an ECG instrument when precision is of utmost importance.

13.
Vasc Endovascular Surg ; 55(4): 355-360, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33535904

RESUMO

BACKGROUND: Adequate seal for thoracic endovascular aortic repair (TEVAR) commonly requires landing in zone 2, but can prove to be challenging due to the tortuous and angulated anatomy of the region. OBJECTIVES: Our objective was to determine the proximal landing accuracy of zone 2-targeted TEVARs following carotid-subclavian revascularization (CSR) and its impact on clinical outcomes. METHODS: Retrospective review of patients that underwent CSR for zone 2 endograft delivery at a tertiary institute between January 2008 and March 2018 was conducted. Technical outcomes were assessed by examining the incidence of intraoperative corrective maneuvers, 1a endoleaks and reinterventions. Distance to target and incidence of LSA stump filling were examined as radiographic markers of landing accuracy. RESULTS: Zone 2-targeted TEVAR with CSR was performed in 53 patients for treatment of dissections (49%), aneurysms (30%) or trauma (21%). Nine (17%) cases required intraoperative corrective procedures: 5 (9%) proximal cuffs due to type 1a endoleak and 4 (8%) left common carotid artery (LCCA) stenting due to inadvertent coverage. Cases performed using higher resolution hybrid fluoroscopy machine compared to mobile C-arm were associated with increased proximal cuff use (OR 8.8; 95% CI 1.2-62.4). Average distance between the proximal edge of the covered graft to LCCA was 8 ± 1 mm and larger distances were not associated with higher rates of 1a endoleak. Twenty-eight (53%) cases of antegrade LSA stump filling were noted on follow-up imaging, but were not associated with higher rates of reinterventions (OR 0.8, 95% CI [0.2-4.6]). Three (6%) patients had a stroke within 30 days and 4 (8%) patients expired within 1 month. Intraoperative corrective maneuvers, post-operative 1a endoleak and reinterventions were not associated with higher rates of stroke or mortality. CONCLUSION: Using current endografts and imaging modalities, zone 2-targeted TEVARs have suboptimal technical accuracy.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Artérias Carótidas/cirurgia , Procedimentos Endovasculares , Artéria Subclávia/cirurgia , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Endoleak/etiologia , Endoleak/mortalidade , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
14.
J Biomech ; 120: 110333, 2021 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-33730560

RESUMO

Deformation properties of venous stents based on braided design, chevron design, Z design, and diamond design are compared using in vitro experiments coupled with analytical and finite element modelling. Their suitability for deployment in different clinical contexts is assessed based on their deformation characteristics. Self-expanding stainless steel stents possess superior collapse resistance compared to Nitinol stents. Consequently, they may be more reliable to treat diseases like May-Thurner syndrome in which resistance against a concentrated (pinching) force applied on the stent is needed to prevent collapse. Braided design applies a larger radial pressure particularly for vessels of diameter smaller than 75% of its nominal diameter, making it suitable for a long lesion with high recoil. Z design has the least foreshortening, which aids in accurate deployment. Nitinol stents are more compliant than their stainless steel counterparts, which indicates their suitability in veins. The semi-analytical method presented can aid in rapid assessment of topology governed deformation characteristics of stents and their design optimization.


Assuntos
Ligas , Stents , Fenômenos Mecânicos , Desenho de Prótese , Aço Inoxidável
15.
Phlebology ; 36(9): 752-760, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34039111

RESUMO

OBJECTIVE: The use of cyanoacrylate products (CA) in incompetent perforator vein (IPV) treatment has not been thoroughly examined. The primary objective of this study is to describe the technique of ultra sound guided direct injection of IPV with CA, and secondarily to determine early closure rates and safety of this technique. METHODS: A retrospective analysis of patients undergoing IPV injection at two centres between 2015-2018 was conducted. Demographics, CEAP classification and IPV location were collected. Outcomes were assessed at two follow-up appointments. RESULTS: A total of 83 perforator vein injections were completed. CEAP classifications include C2 - C6 classes. Location of perforators were posteromedial (6%), femoral canal (9%), paratibial (14%), and posterior-tibial (71%). IPV closure rates were 96.3% at initial follow-up (16 ± 2 days). Closure rates decreased to 86.5% at second follow-up (72 ± 9 days). There were no deep vein thromboses during follow-up. One patient developed septic thrombophlebitis that was successfully managed with antibiotics. CONCLUSION: Ultrasound-guided CA glue injection is a simple and low risk procedure that effectively closes incompetent perforator veins.


Assuntos
Cianoacrilatos , Insuficiência Venosa , Humanos , Estudos Retrospectivos , Escleroterapia , Ultrassonografia de Intervenção
16.
Environ Sci Pollut Res Int ; 28(27): 36039-36052, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33686601

RESUMO

In this study, we determined the concentrations of heavy metals in the agricultural soils of Kafr El-Zayat city using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The LA-ICP-MS performance was firstly evaluated by analyzing appropriate reference materials and comparing the concentration values found to those of the reference values. LA-ICP-MS was then applied to examine the content of 21 elements (Mg, Al, Si, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Rb, Sr, Mo, Sn, Ba, Pb, Th, and U) in 16 collected agricultural soil samples from Egypt. The soil quality was assessed by calculating the contamination factor (CF), enrichment factor (EF), and the geo-accumulation index (Igeo) of the measured heavy metals. The average concentrations of V, Cr, Co, Ni, and Cu were higher than the average worldwide background concentrations and exceeded the Canadian soil quality guidelines with values of 162.8, 113.3, 42.2, 88.1, and 70.6 µg/g, respectively. Multivariate analysis was applied to investigate the correlation and sources of heavy metals in agricultural soils. Cluster analysis indicated the clustering of heavy metals into three groups: Cr and Mo; Fe and Mn; and V, Ni, Co, Cu, Zn, and Pb. The results of principal component analysis (PCA) agreed with those of the cluster analysis and yielded three components that explained 81.13% of the total variance. The contamination factor (CF) of soils from all sampling sites showed moderate contamination.


Assuntos
Terapia a Laser , Metais Pesados , Poluentes do Solo , Canadá , Cidades , Egito , Monitoramento Ambiental , Espectrometria de Massas , Metais Pesados/análise , Medição de Risco , Solo , Poluentes do Solo/análise
17.
J Vasc Surg Venous Lymphat Disord ; 9(5): 1200-1208, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33359385

RESUMO

OBJECTIVE: Definitive treatment techniques for symptomatic deep venous reflux have been relegated to complex and invasive open surgery which is rarely performed today. The BlueLeaf System provides an endovenous method for the formation of deep venous valves without an implant, avoiding the complications associated with permanent foreign materials. The system has the adaptability to form valves within the femoral and popliteal veins at multiple levels in a single procedure. The aim was to determine the midterm safety and efficacy of this novel device in an early feasibility study. METHODS: Feasibility of endovenous deep venous valve formation was assessed in patients with chronic venous insufficiency (Clinical, Etiologic, Anatomic, Pathophysiologic [CEAP] 4-6). Follow-up was completed through 1 year, assessing vein patency and reflux time (RT) with duplex ultrasound examination. Venous clinical improvement was evaluated using the revised Venous Clinical Severity Scale. RESULTS: Of the 14 patients, 13 (93%) had successful formation of at least one monocuspid valve, with a mean number of 1.4 valves (range, 0-3 valves) per patient. There were no device-related serious adverse events during the index procedure. There were no deep venous thromboses reported at any time point, including 10 patients through the 1-year follow-up. In patients with at least one valve formed, site reported duplex ultrasound examination measured the average RT in the popliteal vein below valve formations, was 3.0 ± 1.0 seconds at baseline, 3.9 ± 3.1 seconds at 30 days, and 3.6 ± 2.1 seconds at 360 days. The revised Venous Clinical Severity Scale improved in all 13 successfully treated patients, decreasing from 15.0 ± 6.0 at baseline to 11.6 ± 5.5 at 30 days, 10.7 ± 5.3 at 210 days, and 9.4 ± 5.0 at 360 days (P = .0002; baseline to 360 days). Among the five patients with an ulcer who reached the 360-day follow-up visit, all (100%) healed at least one ulcer. Two patients (40%) healed all ulcers and three patients (60%) had a decrease in ulcers number but remained at C6 at 360 days. The five patients with a total of nine active ulcers at baseline had four active ulcers at 360 days. CONCLUSIONS: The BlueLeaf System holds promise as a minimally invasive means to safely form fully autogenous deep venous valves. Reconstructed deep veins remained patent, without deep venous thrombosis and symptomatic improvement was consistently observed; however, a decrease in the RT was not. Incremental device design improvements have been undertaken to improve valve function. The results of these iterations await further clinical evaluation.


Assuntos
Procedimentos Endovasculares/instrumentação , Veia Femoral/cirurgia , Veia Poplítea/cirurgia , Insuficiência Venosa/cirurgia , Idoso , Estudos de Viabilidade , Feminino , Veia Femoral/diagnóstico por imagem , Humanos , Masculino , Veia Poplítea/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
20.
J Investig Med ; 57(5): 640-4, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19491627

RESUMO

BACKGROUND: Peripheral arterial disease is mainly caused by atherosclerosis and is characterized by decreased circulation, lower blood pressure, and insufficient tissue perfusion in the lower extremities. The hemodynamics of standing and altered gravity environments have been well studied relative to arm blood pressures but are less well understood for ankle pressures. METHODS: Because regional blood pressure depends, in part, on the gravitational pressure gradient, we hypothesized that artificial gravity exposure on a short-arm centrifuge with the center of rotation above the head would increase blood pressure in the lower extremities. Cardiovascular parameters for 12 healthy subjects were measured during exposure to supine short-arm centrifugation at 20, 25, and 30 revolutions per minute (rpm), corresponding to centripetal accelerations of 0.94, 1.47, and 2.11 Gz at the foot level, respectively. RESULTS: Systolic ankle blood pressure significantly increased at all levels of centrifugation. Ankle-brachial indices (the ratio of systolic ankle to arm blood pressures) increased significantly from 1.17 +/- 0.03 to 1.58 +/- 0.03 at 0.94 Gz (P < 0.005), 1.74 +/- 0.02 at 1.47 Gz (P < 0.005), and 1.89 +/- 0.06 at 2.11 Gz (P < 0.005). Systolic arm blood pressure significantly increased at 2.11 Gz, but heart rate did not change significantly. All parameters returned to normal after cessation of centrifugation. CONCLUSIONS: We demonstrated that short-radius centrifugation leads to an increase in ankle-brachial indices. This could have potential implications for the treatment of peripheral arterial disease.


Assuntos
Índice Tornozelo-Braço/métodos , Gravidade Alterada , Doenças Vasculares Periféricas/diagnóstico , Adulto , Pressão Sanguínea , Centrifugação/métodos , Feminino , Humanos , Masculino , Microcirculação , Doenças Vasculares Periféricas/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa