Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Circulation ; 149(25): 1938-1948, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38804148

RESUMO

BACKGROUND: Ascending aorta dilation and aortic valve degeneration are common complications in patients with bicuspid aortic valve. Several retrospective studies have suggested the benefit of statins in reducing these complications. This study aimed to determine whether atorvastatin treatment is effective in reducing the growth of aortic diameters in bicuspid aortic valve and if it slows the progression of valve calcification. METHODS: In a randomized clinical trial, 220 patients with bicuspid aortic valve (43 women; 46±13 years of age) were included and treated with either 20 mg of atorvastatin per day or placebo for 3 years. Inclusion criteria were ≥18 years of age, nonsevere valvular dysfunction, nonsevere valve calcification, and ascending aorta diameter ≤50 mm. Computed tomography and echocardiography studies were performed at baseline and after 3 years of treatment. RESULTS: During follow-up, 28 patients (12.7%) discontinued medical treatment (15 on atorvastatin and 13 taking placebo). Thus, 192 patients completed the 36 months of treatment. Low-density lipoprotein cholesterol levels decreased significantly in the atorvastatin group (median [interquartile range], -30 mg/dL [-51.65 to -1.75 mg/dL] versus 6 mg/dL [-4, 22.5 mg/dL]; P<0.001). The maximum ascending aorta diameter increased with no differences between groups: 0.65 mm (95% CI, 0.45-0.85) in the atorvastatin group and 0.74 mm (95% CI, 0.45-1.04) in the placebo group (P=0.613). Similarly, no significant differences were found for the progression of the aortic valve calcium score (P=0.167) or valvular dysfunction. CONCLUSIONS: Among patients with bicuspid aortic valve without severe valvular dysfunction, atorvastatin treatment was not effective in reducing the progression of ascending aorta dilation and aortic valve calcification during 3 years of treatment despite a significant reduction in low-density lipoprotein cholesterol levels. REGISTRATION: URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2015-001808-57. URL: https://www.clinicaltrials.gov; Unique identifier: NCT02679261.


Assuntos
Valva Aórtica , Atorvastatina , Doença da Válvula Aórtica Bicúspide , Calcinose , Progressão da Doença , Doenças das Valvas Cardíacas , Inibidores de Hidroximetilglutaril-CoA Redutases , Humanos , Atorvastatina/uso terapêutico , Feminino , Masculino , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/anormalidades , Valva Aórtica/efeitos dos fármacos , Calcinose/tratamento farmacológico , Calcinose/diagnóstico por imagem , Calcinose/patologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/tratamento farmacológico , Doenças das Valvas Cardíacas/tratamento farmacológico , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/patologia , Adulto , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Dilatação Patológica/tratamento farmacológico , Seguimentos , Método Duplo-Cego , Resultado do Tratamento , Aorta/diagnóstico por imagem , Aorta/patologia , Aorta/efeitos dos fármacos , Valvopatia Aórtica/tratamento farmacológico , Estenose da Valva Aórtica
2.
Eur Radiol ; 2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38183450

RESUMO

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.

3.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211655

RESUMO

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Assuntos
Aorta Torácica , Doenças da Aorta , Meios de Contraste , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Variações Dependentes do Observador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Idoso , Meios de Contraste/administração & dosagem , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória , Adulto , Fatores de Tempo , Interpretação de Imagem Assistida por Computador , Técnicas de Imagem de Sincronização Cardíaca
4.
Eur Radiol ; 32(3): 1997-2009, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34655311

RESUMO

OBJECTIVES: Manual assessment of aortic diameters on double-oblique reformatted computed tomography angiograms (CTA) is considered the current standard, although the reproducibility for growth rates has not been reported. Deformable registration of CTA has been proposed to provide 3D aortic diameters and growth maps, but validation is lacking. This study aimed to quantify accuracy and inter-observer reproducibility of registration-based and manual assessment of aortic diameters and growth rates. METHODS: Forty patients with ≥ 2 CTA acquired at least 6 months apart were included. Aortic diameters and growth rate were obtained in the aortic root and the entire thoracic aorta using deformable image registration by two independent observers, and compared with the current standard at typical anatomical landmarks. RESULTS: Compared with manual assessment, the registration-based technique presented low bias (0.46 mm), excellent agreement (ICC = 0.99), and similar inter-observer reproducibility (ICC = 0.99 for both) for aortic diameters; and low bias (0.10 mm/year), good agreement (ICC = 0.82), and much higher inter-observer reproducibility for growth rates (root: ICC = 0.96 vs 0.68; thoracic aorta: ICC = 0.96 vs 0.80). Registration-based growth rate reproducibility over a 6-month-long follow-up was similar to that obtained by manual assessment after 2.7 years (LoA = [- 0.01, 0.33] vs [- 0.13, 0.21] mm/year, respectively). Mapping of diameter and growth rate was highly reproducible (ICC > 0.9) in the whole thoracic aorta. CONCLUSIONS: Registration-based assessment of aortic dilation on CTA is accurate and substantially more reproducible than the current standard, even at follow-up as short as 6 months, and provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks. KEY POINTS: • Registration-based semi-automatic assessment of progressive aortic dilation on CTA is accurate and substantially more reproducible than the current standard. • The registration-based technique allows robust growth rate assessment at follow-up as short as 6 months, with a similar reproducibility to that obtained by manual assessment at around 3 years. • The use of image registration provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Aorta , Aorta Torácica/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
5.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35346239

RESUMO

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Rigidez Vascular , Dissecção Aórtica/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Análise de Onda de Pulso
6.
Eur Radiol ; 31(12): 9262-9272, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33977309

RESUMO

OBJECTIVE: Bicuspid aortic valve (BAV), the most common congenital valve defect, is associated with increased risk of aortic dilation and related complications; however, current risk assessment is not effective. Most of BAV have three leaflets with a fusion between two of them of variable length. This study aimed to ascertain whether the extent of leaflet fusion (often called raphe) is related to aortic dilation and flow abnormalities in BAV with no significant valvular dysfunction. METHODS: One hundred and twenty BAV patients with no significant valvular dysfunction or history of surgical repair or aortic valve replacement were consecutively and prospectively enrolled (September 2014-October 2018). Cardiac magnetic resonance protocol included a 4D flow sequence for haemodynamic assessment. Moreover, a stack of double-oblique cine images of the aortic valve were used to quantify fusion length (in systole) and leaflet length (diastole). Inter- and intra-observer reproducibility was tested in 30 randomly selected patients. RESULTS: Aortic valve leaflet fusion was measurable in 112 of 120 (93%) cases with good reproducibility (ICC = 0.826). Fusion length varied greatly (range: 2.3-15.4 mm; mean: 7.8 ± 3.2 mm). After correction for demographic and clinical conditions, fusion length was independently associated with diameter and z-score at the sinus of Valsalva (p = 0.002 and p = 0.002, respectively) and ascending aorta (p = 0.028 and p = 0.046). Fusion length was positively related to flow asymmetry, vortices and circumferential wall shear stress, thereby possibly providing a pathophysiological link with aortic dilation. CONCLUSIONS: Aortic valve fusion length is related to aortic dilation and flow abnormalities in BAV patients. KEY POINTS: • The length of the fusion between leaflets in non-dysfunctional bicuspid aortic valves varies substantially and can be reliably measured by cine CMR. • Aortic valve leaflet fusion length is independently related to aortic sinus and ascending aorta diameter. • Increased flow asymmetry, circumferential wall shear stress and presence of vortices are positively related to aortic valve leaflet fusion length.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Valva Aórtica/diagnóstico por imagem , Dilatação , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
7.
Arterioscler Thromb Vasc Biol ; 40(1): e10-e20, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31801375

RESUMO

OBJECTIVE: To assess the relationship between regional wall shear stress (WSS) and oscillatory shear index (OSI) and aortic dilation in patients with bicuspid aortic valve (BAV). Approach and Results: Forty-six consecutive patients with BAV (63% with right-left-coronary-cusp fusion, aortic diameter ≤ 45 mm and no severe valvular disease) and 44 healthy volunteers were studied by time-resolved 3-dimensional phase-contrast magnetic resonance imaging. WSS and OSI were quantified at different levels of the ascending aorta and the aortic arch, and regional WSS and OSI maps were obtained. Seventy percent of BAV had ascending aorta dilation. Compared with healthy volunteers, patients with BAV had increased WSS and decreased OSI in most of the ascending aorta and the aortic arch. In both BAV and healthy volunteers, regions of high WSS matched regions of low OSI and vice versa. No regions of both low WSS and high OSI were identified in BAV compared with healthy volunteers. Patients with BAV with dilated compared with nondilated aorta presented low and oscillatory WSS in the aortic arch, but not in the ascending aorta where dilation is more prevalent. Furthermore, no regions of concomitant low WSS and high OSI were identified when BAV were compared according to leaflet fusion pattern, despite the well-known differences in regional dilation prevalence. CONCLUSIONS: Regions with low WSS and high OSI do not match those with the highest prevalence of dilation in patients with BAV, thus providing no evidence to support the low and oscillatory shear stress theory in the pathogenesis of proximal aorta dilation in the presence of BAV.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Fluxo Sanguíneo Regional/fisiologia , Resistência ao Cisalhamento/fisiologia , Adulto , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/fisiopatologia , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Feminino , Seguimentos , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença , Estresse Mecânico
8.
Perfusion ; 36(3): 269-276, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32650695

RESUMO

BACKGROUND: The aim of this aortic stenosis registry was to investigate the changes of routine echocardiographic indices and strain in patients with moderate-to-severe aortic stenosis over a 6-month follow-up period. METHODS: Our aortic stenosis registry is observational, prospective, multicenter registry of nine countries, with 197 patients with aortic valve area less than 1.5 cm2. The enrolment took place from January to August 2017. We excluded patients with uncontrolled atrial arrhythmias, pulmonary hypertension or cardiomyopathies, as well as those with hemodynamically significant valvular disease other than aortic stenosis. We included patients who did not require intervention and who had a complete follow-up study. RESULTS: In patients with preserved ejection fraction, left ventricular mass has significantly increased between baseline and follow-up studies (218 ± 34 grams vs 253 ± 29 grams, p = 0.02). However, when indexed to body surface area, there was no significant difference. Left ventricular global longitudinal strain significantly decreased (-19.7 ± -4.8 vs (-16.4 vs -3.8, p = 0.01). Left atrial volume was significantly higher at follow-up (p = 0.035). Right ventricular basal diameter and mid-cavity diameter were greater at the follow-up (p = 0.04 and p = 0.035, respectively). Patients with low-flow low-gradient aortic stenosis had significantly lower global longitudinal strain (-12.3% ± -3.9% vs -19.7% ± -4.8%, p = 0.01). CONCLUSION: Left atrial dilatation is one of the first changes to take place in low-flow low-gradient aortic stenosis patients even when left ventricular dimensions and function remains intact. Global longitudinal strain is an important determinant of left ventricular systolic and diastolic dysfunction and right ventricular function is an important parameter of aortic stenosis assessment. Accordingly, our registry has further shed the light on these indices role as multisite follow-up of aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Seguimentos , Humanos , Estudos Prospectivos , Sistema de Registros , Índice de Gravidade de Doença , Volume Sistólico
10.
Biomedicines ; 12(2)2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38397982

RESUMO

INTRODUCTION AND PURPOSE: Bicuspid aortic valve (BAV) disease is associated with faster aortic valve degeneration and a high incidence of aortic stenosis (AS). In this study, we aimed to identify differences in the pathophysiology of AS between BAV and tricuspid aortic valve (TAV) patients in a multiomics study integrating metabolomics and transcriptomics as well as clinical data. METHODS: Eighteen patients underwent aortic valve replacement due to severe aortic stenosis: 8 of them had a TAV, while 10 of them had a BAV. RNA sequencing (RNA-seq) and proton nuclear magnetic resonance spectroscopy (1H-NMR) were performed on these tissue samples to obtain the RNA profile and lipid and low-molecular-weight metabolites. These results combined with clinical data were posteriorly compared, and a multiomic profile specific to AS in BAV disease was obtained. RESULTS: H-NMR results showed that BAV patients with AS had different metabolic profiles than TAV patients. RNA-seq also showed differential RNA expression between the groups. Functional analysis helped connect this RNA pattern to mitochondrial dysfunction. Integration of RNA-seq, 1H-NMR and clinical data helped create a multiomic profile that suggested that mitochondrial dysfunction and oxidative stress are key players in the pathophysiology of AS in BAV disease. CONCLUSIONS: The pathophysiology of AS in BAV disease differs from patients with a TAV and has a specific RNA and metabolic profile. This profile was associated with mitochondrial dysfunction and increased oxidative stress.

11.
Radiol Cardiothorac Imaging ; 6(3): e230247, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38900026

RESUMO

Purpose To use unsupervised machine learning to identify phenotypic clusters with increased risk of arrhythmic mitral valve prolapse (MVP). Materials and Methods This retrospective study included patients with MVP without hemodynamically significant mitral regurgitation or left ventricular (LV) dysfunction undergoing late gadolinium enhancement (LGE) cardiac MRI between October 2007 and June 2020 in 15 European tertiary centers. The study end point was a composite of sustained ventricular tachycardia, (aborted) sudden cardiac death, or unexplained syncope. Unsupervised data-driven hierarchical k-mean algorithm was utilized to identify phenotypic clusters. The association between clusters and the study end point was assessed by Cox proportional hazards model. Results A total of 474 patients (mean age, 47 years ± 16 [SD]; 244 female, 230 male) with two phenotypic clusters were identified. Patients in cluster 2 (199 of 474, 42%) had more severe mitral valve degeneration (ie, bileaflet MVP and leaflet displacement), left and right heart chamber remodeling, and myocardial fibrosis as assessed with LGE cardiac MRI than those in cluster 1. Demographic and clinical features (ie, symptoms, arrhythmias at Holter monitoring) had negligible contribution in differentiating the two clusters. Compared with cluster 1, the risk of developing the study end point over a median follow-up of 39 months was significantly higher in cluster 2 patients (hazard ratio: 3.79 [95% CI: 1.19, 12.12], P = .02) after adjustment for LGE extent. Conclusion Among patients with MVP without significant mitral regurgitation or LV dysfunction, unsupervised machine learning enabled the identification of two phenotypic clusters with distinct arrhythmic outcomes based primarily on cardiac MRI features. These results encourage the use of in-depth imaging-based phenotyping for implementing arrhythmic risk prediction in MVP. Keywords: MR Imaging, Cardiac, Cardiac MRI, Mitral Valve Prolapse, Cluster Analysis, Ventricular Arrhythmia, Sudden Cardiac Death, Unsupervised Machine Learning Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Prolapso da Valva Mitral , Fenótipo , Aprendizado de Máquina não Supervisionado , Humanos , Prolapso da Valva Mitral/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sistema de Registros , Imagem Cinética por Ressonância Magnética/métodos , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Adulto , Imageamento por Ressonância Magnética
12.
J Am Coll Cardiol ; 82(5): 448-464, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37495282

RESUMO

Bicuspid aortic valve is the most common congenital heart disease and exposes patients to an increased risk of aortic dilation and dissection. Aortic dilation is a slow, silent process, leading to a greater risk of aortic dissection. The prevention of adverse events together with optimization of the frequency of the required lifelong imaging surveillance are important for both clinicians and patients and motivated extensive research to shed light on the physiopathologic processes involved in bicuspid aortic valve aortopathy. Two main research hypotheses have been consolidated in the last decade: one supports a genetic basis for the increased prevalence of dilation, in particular for the aortic root, and the second supports the damaging impact on the aortic wall of altered flow dynamics associated with these structurally abnormal valves, particularly significant in the ascending aorta. Current opinion tends to rule out mutually excluding causative mechanisms, recognizing both as important and potentially clinically relevant.


Assuntos
Doenças da Aorta , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/epidemiologia , Dilatação , Doenças da Aorta/complicações
13.
Can J Cardiol ; 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38013065

RESUMO

BACKGROUND: Percutaneous mitral paravalvular leak (PVL) closure techniques are an effective and safe alternative to surgical treatment, but data regarding long-term outcomes are scarce. We aim to describe the impact of successful percutaneous mitral PVL closure on long-term outcomes. METHODS: All consecutive patients in whom a first-attempt percutaneous mitral PVL closure was performed in a single tertiary centre between January 2010 and October 2021 were included. Clinical variables, procedural details, and procedural success were collected. Patients were classified based on procedural success, defined as no more than mild residual leak. All-cause mortality was the primary endpoint. Cardiovascular death and heart failure hospitalizations (HFHs) were key secondary endpoints. RESULTS: Ninety patients (median age 72.5 years [66.0-78.4]; median EuroSCORE-II 8.2 [5.3-12.46]) were included. Although reduction of at least 1 degree in PVL severity was achieved in 82 (91.1%), procedural success was achieved in 47 (52.2%). Chronic kidney disease, previous surgery for PVL, and the presence of multiple jets were independently associated with procedural failure. After a median follow-up of 3.2 (1.2-5.2) years, mortality rate was higher in the procedural failure group (27.3 per 100 patients-years) compared with the group with successful closure (8.2 per 100 patient-years). Procedural failure was associated with all-cause death (adjusted hazard ratio [aHR], 2.59; 95% confidence interval [CI], 1.41-4.78), cardiovascular death (aHR, 3.53; 95% CI, 1.67-7.49) and HFH (aHR, 3.27; 95% CI,1.72-6.20). CONCLUSIONS: A successful reduction in PVL to mild or absent is associated with improved rates of all-cause death, cardiovascular death, and HFHs.

14.
Artigo em Inglês | MEDLINE | ID: mdl-37490995

RESUMO

BACKGROUND: Blunt traumatic thoracic aortic injuries (BTAIs) are associated with a high mortality rate. Thoracic endovascular aortic repair (TEVAR) is the most frequently used surgical strategy in patients with BTAI, as it offers good short- and middle-term results. Previous studies have reported an abnormally high prevalence of hypertension (HT) in these patients. This work aimed to describe the long-term prevalence of HT and provide a comprehensive evaluation of the biomechanical, clinical, and functional factors involved in HT development. METHODS: Twenty-six patients treated with TEVAR following BTAI with no history of HT at the time of trauma were enrolled. They were matched with 37 healthy volunteers based on age, sex, and body surface area and underwent a comprehensive follow-up study, including cardiovascular magnetic resonance, 24-hour ambulatory blood pressure monitoring, and assessment of carotid-femoral pulse wave velocity (cfPWV, a measure of aortic stiffness) and flow-mediated vasodilation. RESULTS: The mean patient age was 43.5 ± 12.9 years, and the majority were male (23 of 26; 88.5%). At a mean of 120.2 ± 69.7 months after intervention, 17 patients (65%) presented with HT, 14 (54%) had abnormal nighttime blood pressure dipping, and 6 (23%) high cfPWV. New-onset HT was related to a more proximal TEVAR landing zone and greater distal oversizing. Abnormal nighttime blood pressure was related to high cfPWV, which in turn was associated with TEVAR length and premature arterial aging. CONCLUSIONS: HT frequently occurs otherwise healthy subjects undergoing TEVAR implantation after BTAI. TEVAR stiffness and length, the proximal landing zone, and distal oversizing are potentially modifiable surgical characteristics related to abnormal blood pressure.

15.
Heart ; 109(15): 1153-1158, 2023 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-37147129

RESUMO

OBJECTIVES: To describe the aortic-related risks associated with pregnancy in women with bicuspid aortic valve (BAV) and to evaluate changes in aortic diameter in pregnancy. METHODS: Prospective observational study of patients with BAV from a single-site registry of pregnant women with structural heart disease between 2013 and 2020. Cardiac, obstetric and neonatal outcomes were studied. An assessment of aortic dimensions was performed during pregnancy by two-dimensional echocardiography. Aortic diameters were measured at the annulus, root, sinotubular junction and maximum ascending aorta diameter, and the largest diameter was used. Measurements of the aorta were made using the end-diastolic leading edge-to-leading edge convention. RESULTS: Forty-three women (32.9 years, IQR 29.6-35.3) with BAV were included: 9 (20.9%) had repaired aortic coarctation; 23 (53.5%) had moderate or severe aortic valve disease; 5 (11.6%) had a bioprosthetic aortic valve; and 2 (4.7%) had a mechanical prosthetic aortic valve. Twenty (47.0%) were nulliparous. The mean aortic diameter in the first trimester was 38.5 (SD 4.9) mm, and that in the third trimester was 38.4 (SD 4.8) mm. Forty (93.0%) women had an aortic diameter of <45 mm; 3 (7.0%) had 45-50 mm; and none had >50 mm. Three women (6.9%) with BAV presented cardiovascular complications during pregnancy or the postpartum period (two prosthetic thrombosis and one heart failure). No aortic complications were reported. There was a small but significant increase in aortic diameter during pregnancy (third trimester vs first trimester, 0.52 (SD 1.08) mm; p=0.03). Obstetric complications appeared in seven (16.3%) of pregnancies, and there were no maternal deaths. Vaginal non-instrumental delivery was performed in 21 (51.2%) out of 41 cases. There were no neonatal deaths, and the mean newborn weight was 3130 g (95% CI 2652 to 3380). CONCLUSIONS: Pregnancy in BAV women had a low rate of cardiac complications with no aortic complications observed in a small study group. Neither aortic dissection nor need for aortic surgery was reported. A low but significant aortic growth was observed during pregnancy. Although requiring follow-up, the risk of aortic complications in pregnant women with BAV and aortic diameters of <45 mm at baseline is low.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Gravidez , Recém-Nascido , Humanos , Feminino , Masculino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/diagnóstico por imagem , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos
16.
JACC Adv ; 2(8): 100626, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38938356

RESUMO

Background: Clinical outcomes of bicuspid aortic valve (BAV) patients with ascending aortic diameters ≥50 mm who are under surveillance are poorly defined. Objectives: The purpose of this study was to assess clinical outcomes in BAV patients with ascending aorta ≥50 mm. Methods: Multicenter retrospective cohort study of BAV adults with ascending aorta diameters ≥50 mm by transthoracic echocardiography (TTE). Patients were categorized into 50 to 54 mm and ≥55 mm groups. Clinical outcomes were aortic dissection (AoD), aorta surgery, surgical mortality, and all-cause death. Results: Of 875 consecutive BAV patients (age 60 ± 13 years, 86% men, aortic diameter 51 mm [interquartile range (IQR): 50-53 mm]), 328 (37%) underwent early surgery ≤3 months from index TTE. Of the remaining 547 patients under surveillance, 496 had diameters 50 to 54 mm and 51 had diameters ≥55 mm and were collectively followed for 7.51 (IQR: 3.98-12.20) years. Of 496 patients with diameters 50 to 54 mm under surveillance, 266 (54%) underwent surgery 2.0 (IQR: 0.77-4.16) years from index TTE. AoD occurred in 9/496 (1.8%) patients for an incidence of 0.4 cases per 100 person-years, surgical mortality was 5/266 (1.9%); and ≥moderate aortic stenosis (but not aorta size) was associated with all-cause death, hazard ratio: 2.05 (95% CI: 1.32-3.20), P = 0.001. Conversely, in 547 total patients under surveillance (including 50-54 mm and ≥55 mm), both aorta size and ≥moderate aortic stenosis were associated with all-cause death (both P ≤ 0.027). AoD rate in patients ≥55 mm under surveillance was 5.9%. Conclusions: In BAV patients with ascending aorta 50 to 54 mm under surveillance, AoD incidence is low and the overall rates of AoD and surgical mortality are similar, suggesting clinical equivalence between surgical and surveillance strategies. Conversely, patients with aortas ≥55 mm should undergo surgery. Aortic stenosis is associated with all-cause death in these patients.

17.
Eur Heart J Cardiovasc Imaging ; 24(8): 1120-1128, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37131301

RESUMO

AIMS: To assess the progression of the disease and evolution of the main echocardiographic variables for quantifying AS in patients with severe low-flow low-gradient (LFLG) AS compared to other severe AS subtypes. METHODS AND RESULTS: Longitudinal, observational, multicenter study including consecutive asymptomatic patients with severe AS (aortic valve area, AVA < 1.0 cm²) and normal left ventricle ejection fraction (LVEF ≥ 50%). Patients were classified according to baseline echocardiography into: HG (high gradient; mean gradient ≥ 40 mmHg), NFLG (normal-flow low-gradient; mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35mL/m2), or LFLG (mean gradient < 40 mmHg, SVi ≤ 35 mL/m²). AS progression was analyzed by comparing patients' baseline measurements and their last follow-up measurements or those taken prior to aortic valve replacement (AVR). Of the 903 included patients, 401 (44.4%) were HG, 405 (44.9%) NFLG, and 97 (10.7%) LFLG. Progression of the mean gradient in a linear mixed regression model was greater in low-gradient groups: LFLG vs. HG (regression coefficient 0.124, P = 0.005) and NFLG vs. HG (regression coefficient 0.068, P = 0.018). No differences were observed between the LFLG and NFLG groups (regression coefficient 0.056, P = 0.195). However, AVA reduction was slower in the LFLG group compared to the NFLG (P < 0.001). During follow-up, in conservatively-managed patients, 19.1% (n = 9) of LFLG patients evolved to having NFLG AS and 44.7% (n = 21) to having HG AS. In patients undergoing AVR, 58.0% (n = 29) of LFLG baseline patients received AVR with a HG AS. CONCLUSION: LFLG AS shows an intermediate AVA and gradient progression compared to NFLG and HG AS. The majority of patients initially classified as having LFLG AS changed over time to having other severe forms of AS, and most of them received AVR with a HG AS.


Assuntos
Estenose da Valva Aórtica , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Valva Aórtica/diagnóstico por imagem , Função Ventricular Esquerda , Volume Sistólico , Índice de Gravidade de Doença , Resultado do Tratamento , Estudos Retrospectivos
18.
J Clin Med ; 12(1)2022 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-36615132

RESUMO

INTRODUCTION: The bicuspid aortic valve (BAV) confers a high risk of ascending aorta dilatation (AAoD), although its progression seems highly variable. Furthermore, the implication of lipoprotein metabolism and inflammation in the mechanisms that underlie AAoD is not fully established. The aim of this study consisted of evaluating the impact of the lipoprotein and glycoprotein profiles in AAOD as well as its progression in BAV aortopathy. METHODS: Using 1H-nuclear magnetic resonance (1H-NMR), we analyzed and compared the lipoprotein and glycoprotein profiles of plasma samples from 152 BAV patients with dilated and nondilated ascending aorta. Additionally, these profiles were also compared for 119 of these patients who were prospectively followed-up clinically and by echocardiography in the long-term (5 years). Ascending aorta dilation velocity (mm/year) was calculated for this analysis. RESULTS: Several parameters related to the lipoprotein profile including remnant cholesterol, small LDL and IDL-cholesterol were found to be significantly increased in the dilated group compared to those in the nondilated group. The glycoprotein A-nuclear magnetic resonance (NMR) signal, a novel inflammation biomarker, was also observed to be increased in the dilated group. After performing multivariate analysis, remnant cholesterol remained an independent variable related to AAoD. In the long-term follow-up, proatherogenic lipoprotein parameters were related to ascending aorta dilatation velocity ascending. After a lineal regression analysis, non-HDL particles remained as an independent predictor of ascending aorta dilation velocity. CONCLUSIONS: Patients with BAV and AAoD presented a more pro-atherogenic profile assessed by 1H-NMR, especially related to triglyceride-rich lipoproteins. This pro-atherogenic profile seems to contribute to the higher growth rate of ascending aorta diameter.

19.
J Clin Med ; 11(2)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35054153

RESUMO

Multimodality imaging is the basis of the diagnosis, follow-up, and surgical management of bicuspid aortic valve (BAV) patients. Transthoracic echocardiography (TTE) is used in our clinical routine practice as a first line imaging for BAV diagnosis, valvular phenotyping and function, measurement of thoracic aorta, exclusion of other aortic malformations, and for the assessment of complications such are infective endocarditis and aortic. Nevertheless, TTE is less useful if we want to assess accurately other aortic segments such as mid-distal ascending aorta, where computed tomography (CT) and magnetic resonance (CMR) could improve the precision of aorta size measurement by multiplanar reconstructions. A major advantage of CT is its superior spatial resolution, which affords a better definition of valve morphology and calcification, accuracy, and reproducibility of ascending aorta size, and allows for coronary artery assessment. Moreover, CMR offers the opportunity of being able to evaluate aortic functional properties and blood flow patterns. In this setting, new developed sequences such as 4D-flow may provide new parameters to predict events during follow up. The integration of all multimodality information facilitates a comprehensive evaluation of morphologic and dynamic features, stratification of the risk, and therapy guidance of this cohort of patients.

20.
Eur Heart J Cardiovasc Imaging ; 23(5): 641-649, 2022 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-34104946

RESUMO

AIMS: To assess aortic flow and stiffness in patients with Loeys-Dietz syndrome (LDS) by 4D flow and cine cardiovascular magnetic resonance (CMR) and compare the results with those of healthy volunteers (HV) and Marfan syndrome (MFS) patients. METHODS AND RESULTS: Twenty-one LDS and 44 MFS patients with no previous aortic dissection or surgery and 35 HV underwent non-contrast-enhanced 4D flow CMR. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), and aortic diameters were obtained at 20 planes from the ascending (AAo) to the proximal descending aorta (DAo). IRF and SFRR were also quantified for aortic regions (proximal and distal AAo, arch and proximal DAo). Peak-systolic wall shear stress (WSS) maps were also estimated. Aortic stiffness was quantified using pulse wave velocity (PWV) and proximal AAo longitudinal strain. Compared to HV, LDS patients had lower rotational flow at the distal AAo (P = 0.002), arch (P = 0.002), and proximal DAo (P < 0.001) even after adjustment for age, stroke volume, and local diameter. LDS patients had higher SFRR in the proximal DAo compared to both HV (P = 0.024) and MFS patients (P = 0.015), even after adjustment for age and local diameter. Axial and circumferential WSS in LDS patients were lower than in HV. AAo circumferential WSS was lower in LDS compared to MFS patients. AAo and DAo PWV and proximal AAo longitudinal strain revealed stiffer aortas in LDS patients compared to HV (P = 0.007, 0.005, and 0.029, respectively) but no differences vs. MFS patients. CONCLUSION: Greater aortic stiffness as well as impaired IRF and WSS were present in LDS patients compared to HV. Conversely, similar aortic stiffness and overlapping aortic flow features were found in Loeys-Dietz and Marfan patients.


Assuntos
Síndrome de Loeys-Dietz , Síndrome de Marfan , Rigidez Vascular , Aorta/diagnóstico por imagem , Aorta/patologia , Voluntários Saudáveis , Humanos , Síndrome de Loeys-Dietz/diagnóstico por imagem , Síndrome de Loeys-Dietz/patologia , Síndrome de Marfan/diagnóstico por imagem , Análise de Onda de Pulso
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa