Anal Chem ; 96(8): 3373-3381, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38345945

RESUMO

While conventional ion-soft landing uses the mass-to-charge (m/z) ratio to achieve molecular selection for deposition, here we demonstrate the use of Structures for Lossless Ion Manipulation (SLIM) for mobility-based ion selection and deposition. The dynamic rerouting capabilities of SLIM were leveraged to enable the rerouting of a selected range of mobilities to a different SLIM path (rather than MS) that terminated at a deposition surface. A selected mobility range from a phosphazene ion mixture was rerouted and deposited with a current pulse (∼150 pA) resembling its mobility peak. In addition, from a mixture of tetra-alkyl ammonium (TAA) ions containing chain lengths of C5-C8, selected chains (C6, C7) were collected on a surface, reconstituted into solution-phase, and subsequently analyzed with a SLIM-qToF to obtain an IMS/MS spectrum, confirming the identity of the selected species. Further, this method was used to characterize triply charged tungsten-polyoxometalate anions, PW12O403- (WPOM). The arrival time distribution of the IMS/MS showed multiple peaks associated with the triply charged anion (PW12O403-), of which a selected ATD was deposited and imaged using TEM. Additionally, the identity of the deposited WPOM was ascertained using energy-dispersive (EDS) spectroscopy. Further, we present theory and computations that reveal ion landing energies, the ability to modulate the energies, and deposition spot sizes.

2.
Anal Chem ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336463

RESUMO

Ion mobility-mass spectrometry (IMS-MS) is used to analyze complex samples and provide structural information on unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. This work evaluated a cyclable and variable path length (and hence resolving power) multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than what was previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators, yielding a total path length of ∼88 m (∼11 m per level). Our new multilevel SLIM can also be operated in an "ion cycling" mode by utilizing a set of return ion escalators that transport ions from the eighth level back to the first, allowing even extendable path lengths (and higher IMS resolution). The platform has been improved to enhance ion transmission and IMS separation quality by reducing the spacing between SLIM boards. The board thickness was reduced to minimize the ions' escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated better transmission for a set of phosphazene ions, especially for the low-mobility ions. For example, the transmission of m/z 2834 ions was improved by a factor of ∼3 in the new multilevel SLIM. The new multilevel SLIM achieved 49% better resolving powers for GRGDS1+ ions in 4 levels than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of reverse sequence peptides (SDGRG1+, GRGDS1+). We achieved 1100 resolving power using 88 m of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels. Further evaluation of the multilevel SLIM demonstrated enhanced separation for positively and negatively charged brain total lipid extract samples. The new multilevel SLIM enables a tunable high resolving power for a wide range of ion mobilities and improved transmission for low-mobility ions.

3.
Anal Chem ; 95(9): 4446-4453, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36820625

RESUMO

Enhancing the sensitivity of low-abundance ions in a complex mixture without sacrificing measurement throughput is highly desirable. This work demonstrates a way to greatly improve the sensitivity of ion mobility (IM)-selected ions by accumulating them in an array of high-capacity ion traps located inside a novel structures for lossless ion manipulations ion mobility spectrometer (SLIM-IMS) module. The array of ion traps used in this work consisted of seven independently controllable traps. Each trap was 386 mm long and possessed a charge capacity of ∼4.5 × 108 charges, with a linear range extending to ∼2.5 × 108 charges. Each ion trap could be used to extract a peak (or ions over a mobility range) from an ion mobility separation based on arrival time. Ions could be stored without losses for long times (>100 s) and then released all at once or one trap at a time. It was possible to accumulate large ion populations by extracting and storing ions over repeated IM separations. Enrichment of up to seven individual ion distributions could be performed using the seven independently controllable ion traps. Additionally, the ion trapping process effectively compressed ion populations into narrow peaks, which provides a greatly improved basis for subsequent ion manipulations. The array of high charge capacity ion traps provides a flexible addition to SLIM and a powerful tool for IMS-MS applications requiring high sensitivity.

4.
J Phys Chem A ; 127(25): 5458-5469, 2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37330993

RESUMO

The role of ion rotation in determining ion mobilities is explored using the subtle gas phase ion mobility shifts based on differences in ion mass distributions between isotopomer ions that have been observed with ion mobility spectrometry (IMS) measurements. These mobility shifts become apparent for IMS resolving powers on the order of ∼1500 where relative mobilities (or alternatively momentum transfer collision cross sections; Ω) can be measured with a precision of ∼10 ppm. The isotopomer ions have identical structures and masses, differing only in their internal mass distributions, and their Ω differences cannot be predicted by widely used computational approaches, which ignore the dependence of Ω on the ion's rotational properties. Here, we investigate the rotational dependence of Ω, which includes changes to its collision frequency due to thermal rotation as well as the coupling of translational to rotational energy transfer. We show that differences in rotational energy transfer during ion-molecule collisions provide the major contribution to isotopomer ion separations, with only a minor contribution due to an increase in collision frequency due to ion rotation. Modeling including these factors allowed for differences in Ω to be calculated that precisely mirror the experimental separations. These findings also highlight the promise of pairing high-resolution IMS measurements with theory and computation for improved elucidation of subtle structural differences between ions.

5.
Anal Chem ; 93(45): 14966-14975, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34726890

RESUMO

The unanticipated discovery of recent ultra-high-resolution ion mobility spectrometry (IMS) measurements revealing that isotopomers─compounds that differ only in the isotopic substitution sites─can be separated has raised questions as to the physical basis for their separation. A study comparing IMS separations for two isotopomer sets in conjunction with theory and simulations accounting for ion rotational effects provides the first-ever prediction of rotation-mediated shifts. The simulations produce observable mobility shifts due to differences in gas-ion collision frequency and translational-to-rotational energy transfer. These differences can be attributed to distinct changes in the moment of inertia and center of mass between isotopomers. The simulations are in broad agreement with the observed experiments and consistent with relative mobility differences between isotopomers. These results provide a basis for refining IMS theory and a new foundation to obtain additional structural insights through IMS.


Assuntos
Espectrometria de Mobilidade Iônica
6.
Anal Chem ; 92(22): 14976-14982, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33136380

RESUMO

The collision cross section (CCS) is an important property that aids in the structural characterization of molecules. Here, we investigated the CCS calibration accuracy with traveling wave ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM) using three sets of calibrants. A series of singly negatively charged phospholipids and bile acids were calibrated in nitrogen buffer gas using two different TW waveform profiles (square and sine) and amplitudes (20, 25, and 30 V0-p). The calibration errors for the three calibrant sets (Agilent tuning mixture, polyalanine, and one assembled in-house) showed negligible differences using a sine-shaped TW waveform. Calibration errors were all within 1-2% of the drift tube ion mobility spectrometry (DTIMS) measurements, with lower errors for sine waveforms, presumably due to the lower average and maximum fields experienced by ions. Finally, ultrahigh-resolution multipass (long path length) SLIM TWIMS separations demonstrated improved CCS calibration for phospholipid and bile acid isomers.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Ácidos e Sais Biliares/química , Calibragem , Eletrodos , Espectrometria de Mobilidade Iônica/instrumentação , Isomerismo , Espectrometria de Massas , Peptídeos/química , Fosfolipídeos/química
7.
Anal Chem ; 92(7): 5004-5012, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32142606

RESUMO

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. Herein, we report on the use of high-resolution ion mobility spectrometry separations in structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 m SLIM IMS separation, the various drug-bound antibody species could be well resolved for both chains. We also show significantly higher resolution separations were possible for these large ions with SLIM IMS as compared to ones performed on a commercially available (1 m) drift tube IMS-MS platform. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.


Assuntos
Anticorpos Monoclonais/química , Imunoconjugados/química , Preparações Farmacêuticas/química , Humanos , Espectrometria de Massas , Estrutura Molecular
8.
Anal Chem ; 92(22): 14930-14938, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33105077

RESUMO

Ion packets introduced from gates, ion funnel traps, and other conventional ion injection mechanisms produce ion pulse widths typically around a few microseconds or less for ion mobility spectrometry (IMS)-based separations on the order of 100 milliseconds. When such ion injection techniques are coupled with ultralong path length traveling wave (TW)-based IMS separations (i.e., on the order of seconds) using structures for lossless ion manipulations (SLIMs), typically very low ion utilization efficiency is achieved for continuous ion sources [e.g., electrospray ionization (ESI)]. Even with the ability to trap and accumulate much larger populations of ions than being conventionally feasible over longer time periods in SLIM devices, the subsequent long separations lead to overall low ion utilization. Here, we report the use of a highly flexible SLIM arrangement, enabling concurrent ion accumulation and separation and achieving near-complete ion utilization with ESI. We characterize the ion accumulation process in SLIM, demonstrate >98% ion utilization, and show both increased signal intensities and measurement throughput. This approach is envisioned to have broad utility to applications, for example, involving the fast detection of trace chemical species.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Razão Sinal-Ruído , Espectrometria de Massas por Ionização por Electrospray
9.
Anal Chem ; 92(11): 7972-7979, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32383592

RESUMO

Over the past few years, structures for lossless ion manipulations (SLIM) have used traveling waves (TWs) to move ions over long serpentine paths that can be further lengthened by routing the ions through multiple passages of the same path. Such SLIM "multipass" separations provide unprecedentedly high ion mobility resolving powers but are ultimately limited in their ion mobility range because of the range of mobilities spanned in a single pass; that is, higher mobility ions ultimately "overtake" and "lap" lower mobility ions that have experienced fewer passes, convoluting their arrival time distribution at the detector. To achieve ultrahigh resolution separations over broader mobility ranges, we have developed a new multilevel SLIM possessing multiple stacked serpentine paths. Ions are transferred between SLIM levels through apertures (or ion escalators) in the SLIM surfaces. The initial multilevel SLIM module incorporates four levels and three interlevel ion escalator passages, providing a total path length of 43.2 m. Using the full path length and helium buffer gas, high resolution separations were achieved for Agilent tuning mixture phosphazene ions over a broad mobility range (K0 ≈ 3.0 to 1.2 cm2/(V*s)). High sensitivity was achieved using "in-SLIM" ion accumulation over an extended trapping region of the first SLIM level. High transmission efficiency of ions over a broad mobility range (e.g., K0 ≈ 3.0 to 1.67 cm2/(V*s)) was achieved, with transmission efficiency rolling off for the lower mobility ions (e.g., K0 ≈ 1.2 cm2/(V*s)). Resolving powers of up to ∼560 were achieved using all four ion levels to separate reverse peptides (SDGRG1+ and GRGDS1+). A complex mixture of phosphopeptides showed similar coverage could be achieved using one or all four SLIM levels, and doubly charged phosphosite isomers not significantly separated using one SLIM level were well resolved when four levels were used. The new multilevel SLIM technology thus enables wider mobility range ultrahigh-resolution ion mobility separations and expands on the ability of SLIM to obtain improved separations of complex mixtures with high sensitivity.


Assuntos
Fosfopeptídeos/análise , Espectrometria de Mobilidade Iônica , Íons/química , Conformação Proteica , Estereoisomerismo , Propriedades de Superfície
10.
Anal Chem ; 91(22): 14712-14718, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31621288

RESUMO

We describe the development of a dual-polarity traveling-wave (TW) structures for lossless ion manipulations (SLIM) ion mobility spectrometry (IMS) device capable of switching both positive and negative ions that are traveling simultaneously along the same path to different regions of the SLIM. Through simulations, the routing efficiency of the SLIM TW switch was compared to a SLIM direct-current-based (DC) switch developed previously for IMS-MS. We also report on the initial experimental evaluation of a dual-polarity SLIM platform, which uses the TW-based ion switch to achieve higher resolution multipass serpentine ultralong path with extended routing (SUPER) IMS separations. Overall, these results show that the dual-polarity TW switch is not only as effective as DC switching in terms of routing efficiency but also is agnostic to the polarity of the ions being routed.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Íons/química , Eletrodos , Espectrometria de Mobilidade Iônica/instrumentação
11.
Anal Chem ; 91(7): 4374-4380, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30816701

RESUMO

Accumulation of ß-amyloid (Aß) is one of the hallmarks of Alzheimer's disease. The deposition of ß-amyloid plaques is likely to start years in advance of manifestation of clinical symptoms, although the exact timing is unknown. Over the years, Aß peptides undergo both post-translational modification and stereoisomerization. Analysis of the resulting stereoisomers is particularly challenging because of their identical elemental composition and similar physicochemical properties. Herein, we have utilized our recently developed structures for lossless ion manipulations ion mobility-mass spectrometry platform (SLIM IM-MS), in conjunction with serpentine ultralong path with extended routing (SUPER), to baseline resolve four distinct sets of Aß17-28 tryptic peptide epimers on a rapid (∼1 s) time scale. We discovered that sodium adduct ions, [M + H + Na]2+, allowed baseline SLIM SUPER IM resolution for all Aß epimer sets assessed, while such baseline separations were unachievable for their [M + 2H]2+ doubly protonated ions.


Assuntos
Peptídeos beta-Amiloides/análise , Ácido Aspártico/química , Fragmentos de Peptídeos/análise , Peptídeos beta-Amiloides/química , Espectrometria de Massas/métodos , Fragmentos de Peptídeos/química , Estereoisomerismo
12.
Anal Chem ; 91(18): 11952-11962, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31450886

RESUMO

We report on separations of ion isotopologues and isotopomers using ultrahigh-resolution traveling wave-based Structures for Lossless Ion Manipulations with serpentine ultralong path and extended routing ion mobility spectrometry coupled to mass spectrometry (SLIM SUPER IMS-MS). Mobility separations of ions from the naturally occurring ion isotopic envelopes (e.g., [M], [M+1], [M+2], ... ions) showed the first and second isotopic peaks (i.e., [M+1] and [M+2]) for various tetraalkylammonium ions could be resolved from their respective monoisotopic ion peak ([M]) after SLIM SUPER IMS with resolving powers of ∼400-600. Similar separations were obtained for other compounds (e.g., tetrapeptide ions). Greater separation was obtained using argon versus helium drift gas, as expected from the greater reduced mass contribution to ion mobility described by the Mason-Schamp relationship. To more directly explore the role of isotopic substitutions, we studied a mixture of specific isotopically substituted (15N, 13C, and 2H) protonated arginine isotopologues. While the separations in nitrogen were primarily due to their reduced mass differences, similar to the naturally occurring isotopologues, their separations in helium, where higher resolving powers could also be achieved, revealed distinct additional relative mobility shifts. These shifts appeared correlated, after correction for the reduced mass contribution, with changes in the ion center of mass due to the different locations of heavy atom substitutions. The origin of these apparent mass distribution-induced mobility shifts was then further explored using a mixture of Iodoacetyl Tandem Mass Tag (iodoTMT) isotopomers (i.e., each having the same exact mass, but with different isotopic substitution sites). Again, the observed mobility shifts appeared correlated with changes in the ion center of mass leading to multiple monoisotopic mobilities being observed for some isotopomers (up to a ∼0.04% difference in mobility). These mobility shifts thus appear to reflect details of the ion structure, derived from the changes due to ion rotation impacting collision frequency or momentum transfer, and highlight the potential for new approaches for ion structural characterization.


Assuntos
Deutério/química , Isótopos de Carbono/química , Espectrometria de Mobilidade Iônica , Íons/química , Íons/isolamento & purificação , Espectrometria de Massas , Isótopos de Nitrogênio/química
13.
Trends Analyt Chem ; 116: 300-307, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32831434

RESUMO

Ion mobility separations coupled to mass spectrometry (IM-MS) have received much attention for their ability to provide complementary structural information to solution-phase-based separations, as well as to aid in the identification of unknown compounds. While IM-MS is an increasingly powerful analytical technique, significant bottlenecks related to the resolution of measurements have kept it from becoming broadly applied for biological analyses. Presently, IM-MS-based measurements also remain limited in terms of their sensitivity as compared to state of the art MS-based approaches alone. Structures for Lossless Ion Manipulations (SLIM)-based IM separations provide a basis for overcoming these bottlenecks, addressing issues associated with resolution and sensitivity in the omics, and potentially opening the door to much broader application.

14.
Analyst ; 145(1): 240-248, 2019 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-31746829

RESUMO

Probing molecular properties in the gas phase requires the integration of complementary ion manipulation approaches such as ion mobility spectrometry. Structures for lossless ion manipulations (SLIM) have recently been developed to perform ultra-high resolution ion mobility separations using traveling waves as well as providing other advanced capabilities. Despite its success, the design aspects of SLIM have not been fully explored and remained largely unchanged. Here, we report on a computational study using SIMION simulations of a number of traveling wave (TW) patterns that can be used in SLIM. The TW pattern used in the current SLIM device is a set of 8 electrodes where, at any time, 4 electrodes are held at high voltage (i.e., 1111), while the other 4 electrodes are held at low voltage (i.e., 0000), forming one micro-trapping region of 11110000 pattern. Ion trajectory simulations demonstrated the feasibility to simplify the 8-electrode set to a shorter pattern (e.g., 6-electrode or 4-electrode set) while maintaining or improving the performance. The RF and TW amplitudes, guard voltage, and TW speed were optimized subsequently on the symmetric patterns of the 4-, 6-, and 8-electrode sets to further improve the performance. The resolution, peak broadening, peak capacity, and peak generation rate of each pattern were evaluated, showing that the 111000 pattern of the 6-electrode set has comparable performance to the current 11110000 pattern and is always better than the 1100 pattern. This work provides insight into the feasibility for simplification and modification of the TW configuration in SLIM and other traveling wave devices.

15.
Anal Chem ; 90(18): 11086-11091, 2018 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-30102518

RESUMO

Bile acids (BAs) constitute an important class of steroid metabolites often displaying changes associated with disease states and other health conditions. Current analyses for these structurally similar compounds are limited by a lack of sensitivity and long separation times with often poor isomeric resolution. To overcome these challenges and provide rapid analyses for the BA isomers, we utilized cyclodextrin adducts in conjunction with novel ion mobility (IM) separation capabilities provided by structures for lossless ion manipulations (SLIM). Cyclodextrin was found to interact with both the tauro- and glyco-conjugated BA isomers studied, forming rigid noncovalent host-guest inclusion complexes. Without the use of cyclodextrin adducts, the BA isomers were found to be nearly identical in their respective mobilities and thus unable to be baseline resolved. Each separation of the cyclodextrin-bile acid host-guest inclusion complex was performed in less than 1 s, providing a much more rapid alternative to current liquid chromatography-based separations. SLIM provided capabilities for the accumulation of larger ion populations and IM peak compression that resulted in much higher resolution separations and increased signal intensities for the BA isomers studied.


Assuntos
Ácidos e Sais Biliares/isolamento & purificação , Ciclodextrinas/química , Espectrometria de Massas/métodos , Ácidos e Sais Biliares/química , Íons/química , Íons/isolamento & purificação , Isomerismo , Espectrometria de Massas/economia , Modelos Moleculares , Fatores de Tempo
16.
Electrophoresis ; 39(24): 3148-3155, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30168603

RESUMO

Enantiomeric molecular evaluations remain an enormous challenge for current analytical techniques. To date, derivatization strategies and long separation times are generally required in these studies, and the development and implementation of new approaches are needed to increase speed and distinguish currently unresolvable compounds. Herein, we describe a method using chiral cyclodextrin adducts and structures for lossless ion manipulations (SLIM) and serpentine ultralong path with extended routing (SUPER) ion mobility (IM) to achieve rapid, high resolution separations of d and l enantiomeric amino acids. In the analyses, a chiral cyclodextrin is added to each sample. Two cyclodextrins were found to complex each amino acid molecule (i.e. potentially sandwiching the amino acid in their cavities) and forming host-guest noncovalent complexes that were distinct for each d and l amino acid pair studied and thus separable with IM in SLIM devices. The SLIM was also used to accumulate much larger ion populations than previously feasible for evaluation and therefore allow enantiomeric measurements of higher sensitivity, with gains in resolution from our ultralong path separation capabilities, than previously reported by any other IM-based approach.


Assuntos
Aminoácidos/análise , Aminoácidos/química , Ciclodextrinas/química , Aminoácidos/isolamento & purificação , Íons , Espectrometria de Massas/métodos , Modelos Moleculares , Estereoisomerismo
17.
Int J Mass Spectrom ; 430: 8-13, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31467482

RESUMO

Ion mobility (IM) is rapidly gaining attention for the separation and analysis of biomolecules due to the ability to distinguish the shapes of ions. However, conventional constant electric field drift tube IM separations have limited resolving power, constrained by practical limitations on the path length and maximum applied voltage. The implementation of traveling waves (TW) in IM removes the latter limitation, allowing higher resolution to be achieved using extended path lengths. Both of these can be readily obtained in structures for lossless ion manipulations (SLIM), which are fabricated from arrays of electrodes patterned on two parallel surfaces where potentials are applied to generate appropriate electric fields between the surfaces. Here we have investigated the relationship between the primary SLIM variables, such as electrode dimensions, inter-surface gap, and the applied TW voltages, that directly impact the fields experienced by ions. Ion trajectory simulations and theoretical calculations have been utilized to understand the dependence of SLIM geometry and effective electric fields on IM resolution. The variables explored impact both ion confinement and the observed IM resolution using SLIM modules.

18.
Anal Chem ; 89(3): 1972-1977, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-28208272

RESUMO

We describe two approaches based upon ion "elevator" and "escalator" components that allow moving ions to different levels in structures for lossless ion manipulations (SLIM). Guided by ion motion simulations, we designed elevator and escalator components based upon ion current measurements providing essentially lossless transmission in multilevel designs. The ion elevator design allowed ions to efficiently bridge a 4 mm gap between levels. The component was integrated in a SLIM and coupled to a QTOF mass spectrometer using an ion funnel interface to evaluate the m/z range transmitted as compared to transmission within a level (e.g., in a linear section). The analysis of singly charged ions of m/z 600-2700 produced similar mass spectra for both elevator and straight (linear motion) components. In the ion escalator design, traveling waves (TW) were utilized to transport ions efficiently between two SLIM levels. Ion current measurements and ion mobility (IM) spectrometry analysis illustrated that ions can be transported between TW-SLIM levels with no significant loss of either ions or IM resolution. These developments provide a path for the development of multilevel designs providing, e.g., much longer IM path lengths, more compact designs, and the implementation of much more complex SLIM devices in which, e.g., different levels may operate at different temperatures or with different gases.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Íons/química , Espectrometria de Massas/métodos , Eletrodos , Transporte de Íons
19.
Anal Chem ; 89(12): 6432-6439, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28497957

RESUMO

We report on the implementation of a traveling wave (TW) based compression ratio ion mobility programming (CRIMP) approach within structures for lossless ion manipulations (SLIM) that enables both greatly enlarged trapped ion charge capacities and also efficient ion population compression for use in ion mobility (IM) separations. Ion accumulation is conducted in a SLIM serpentine ultralong path with extended routing (SUPER) region after which CRIMP compression allows the large ion populations to be "squeezed". The SLIM SUPER IM module has two regions, one operating with conventional traveling waves (i.e., traveling trap; TT region) and the second having an intermittently pausing or "stuttering" TW (i.e., stuttering trap; ST region). When a stationary voltage profile was used in the ST region, ions are blocked at the TT-ST interface and accumulated in the TT region and then can be released by resuming a conventional TW in the ST region. The population can also be compressed using CRIMP by the repetitive merging of ions distributed over multiple TW bins in the TT region into a single TW bin in the ST region. Ion accumulation followed by CRIMP compression provides the basis for the use of larger ion populations for IM separations. We show that over 109 ions can be accumulated with high efficiency in the present device and that the extent of subsequent compression is only limited by the space charge capacity of the trapping region. Approximately 5 × 109 charges introduced from an electrospray ionization source were trapped for a 40 s accumulation period, more than 2 orders of magnitude greater than the previously reported charge capacity of an ion funnel trap. Importantly, we show that extended ion accumulation in conjunction with CRIMP compression and multiple passes through the serpentine path provides the basis for a highly desirable combination of ultrahigh sensitivity and SLIM SUPER high-resolution IM separations.


Assuntos
Peptídeos/análise , Espectrometria de Mobilidade Iônica/instrumentação , Íons/química , Espectrometria de Massas/instrumentação
20.
Anal Chem ; 89(8): 4628-4634, 2017 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-28332832

RESUMO

Ion mobility (IM) separations have a broad range of analytical applications, but insufficient resolution often limits their utility. Here, we report on ion mobility separations in a structures for lossless ion manipulations (SLIM) serpentine ultralong path with extended routing (SUPER) traveling wave (TW) ion mobility (IM) module in conjunction with mass spectrometry (MS). Ions were confined in the SLIM by rf fields in conjunction with a DC guard bias, enabling essentially lossless TW transmission over greatly extended paths. The extended routing utilized multiple passes (e.g., ∼1094 m over 81 passes through the 13.5 m serpentine path) and was facilitated by the introduction of a lossless ion switch that allowed ions to be directed to either the MS detector or for another pass through the serpentine separation region, allowing theoretically unlimited IM path lengths. The multipass SUPER IM-MS provided resolution approximately proportional to the square root of the number of passes (or total path length). More than 30-fold higher IM resolution (∼340 vs ∼10) for Agilent tuning mix m/z 622 and 922 ions was achieved for 40 passes compared to commercially available drift tube IM and other TWIM-based platforms. An initial evaluation of the isomeric sugars lacto-N-hexaose and lacto-N-neohexaose showed the isomeric structures to be baseline resolved, and a new conformational feature for lacto-N-neohexaose was revealed after 9 passes. The new SLIM SUPER high resolution TWIM platform has broad utility in conjunction with MS and is expected to enable a broad range of previously challenging or intractable separations.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Humanos , Íons/química , Isomerismo , Leite Humano/metabolismo , Oligossacarídeos/química