RESUMO
Current therapies to treat autoimmune diseases often result in side effects such as nonspecific immunosuppression. Therapies that can induce antigen-specific immune tolerance provide an opportunity to reverse autoimmunity and mitigate the risks associated with global immunosuppression. In an effort to induce antigen-specific immune tolerance, co-administration of immunomodulators with autoantigens has been investigated in an effort to reprogram autoimmunity. To date, identifying immunomodulators that may skew the antigen-specific immune response has been ad hoc at best. To address this need, we utilized splenocytes obtained from mice with experimental autoimmune encephalomyelitis (EAE) in order to determine if certain immunomodulators may induce markers of immune tolerance following antigen rechallenge. Of the immunomodulatory compounds investigated, only dexamethasone modified the antigen-specific immune response by skewing the cytokine response and decreasing T-cell populations at a concentration corresponding to a relevant in vivo dose. Thus, antigen-educated EAE splenocytes provide an ex vivo screen for investigating compounds capable of skewing the antigen-specific immune response, and this approach could be extrapolated to antigen-educated cells from other diseases or human tissues.
Assuntos
Autoantígenos/imunologia , Autoimunidade/imunologia , Fatores Imunológicos/imunologia , Animais , Citocinas/imunologia , Encefalomielite Autoimune Experimental/imunologia , Feminino , Tolerância Imunológica/imunologia , Camundongos , Linfócitos T/imunologiaRESUMO
Many current therapies for autoimmune diseases such as multiple sclerosis (MS) result in global immunosuppression, rendering insufficient efficacy with increased risk of adverse side effects. Multivalent soluble antigen arrays, nanomaterials presenting both autoantigen and secondary inhibitory signals on a flexible polymer backbone, are hypothesized to shift the immune response toward selective autoantigenic tolerance to repress autoimmune disease. Two-signal co-delivery of both autoantigen and secondary signal were deemed necessary for therapeutic efficacy against experimental autoimmune encephalomyelitis, a murine model of MS. Dynamic light scattering and in silico molecular dynamics simulations complemented these studies to illuminate the role of two-signal co-delivery in determining therapeutic potential. Physicochemical characteristics such as particle size and molecular affinity for intermolecular interactions and chain entanglement likely facilitated cotransport of two signals to produce efficacy. These findings elucidate potential mechanisms whereby soluble antigen arrays enact their therapeutic effect and help to guide the development of future multivalent antigen-specific immunotherapies.
Assuntos
Autoantígenos/imunologia , Sistemas de Liberação de Medicamentos , Encefalomielite Autoimune Experimental/terapia , Tolerância Imunológica/imunologia , Nanoestruturas/química , Polímeros/química , Animais , Encefalomielite Autoimune Experimental/imunologia , Feminino , Imunoterapia , Camundongos , Simulação de Dinâmica Molecular , Análise Serial de ProteínasRESUMO
Purpose: This paper discusses an advanced version of our audiovisual-assisted therapeutic ambience in radiotherapy (AVATAR) radiolucent display systems designed for pediatric radiotherapy, enabling anesthesia-free treatments, video communication, and biofeedback. The scope of the AVATAR system is expanded here in two major ways: (i) through alternative mounting systems to accommodate a broader range of radiotherapy machines (specifically to fit robotic-arm and toroidal geometry photon radiotherapy and proton radiotherapy systems) and (ii) through additional hardware to provide video-calling, optimized audio for clear communication, and combined video inputs for biofeedback, translation, and other advanced functionalities. Methods and materials: Because robustness requires strong parts and radio-transparency requires thin, light parts, three-dimensional printing was used to rapidly prototype hollow structures and to iteratively improve robustness. Two system designs were made: one that mounts superior and another that mounts inferior to the patient's head. Radiation dose measurements and calculations were conducted to assess dose perturbations at surface and depth due to the screen. Results: For 6-MV volumetric modulated arc therapy (VMAT) plans, with and without the screen, the mean and maximum dose differences inside the planning target volume were 0.2% and 2.6% of the 200 cGy prescription, respectively. For a single static beam through the screen, the maximum measured excess surface dose was 13.4 ± 0.5%, and the largest measured dose attenuation at 5-cm water-equivalent depth was 2.1 ± 0.2%. These percentages are relative to the dose without the screen at those locations. Conclusions: The radiolucent screen systems provided here are shown to give minimal dosimetric effects on megavoltage VMAT photon treatments. For static beams, however, surface dose effects should be considered when these beams pass through the thickest components of the screen. Design files are also provided.
RESUMO
PURPOSE: We conducted a multi-institutional dosimetric audit between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3-dimensional (3D) printed mouse phantom. METHODS AND MATERIALS: A computed tomography (CT) scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene (â¼1.02 g/cm3) and polylactic acid (â¼1.24 g/cm3) simultaneously to simulate soft tissue and bone densities, respectively. The lungs were printed separately using lightweight polylactic acid (â¼0.64 g/cm3). Hounsfield units (HU), densities, and print-to-print stability of the phantoms were assessed. Three institutions were each provided a phantom and each institution performed 2 replicates of irradiations at selected anatomic regions. The average dose difference between FLASH and CONV dose distributions and deviation from the prescribed dose were measured with radiochromic film. RESULTS: Compared with the reference CT scan, CT scans of the phantom demonstrated mass density differences of 0.10 g/cm3 for bone, 0.12 g/cm3 for lung, and 0.03 g/cm3 for soft tissue regions. Differences in HU between phantoms were <10 HU for soft tissue and bone, with lung showing the most variation (54 HU), but with minimal effect on dose distribution (<0.5%). Mean differences between FLASH and CONV decreased from the first to the second replicate (4.3%-1.2%), and differences from the prescribed dose decreased for both CONV (3.6%-2.5%) and FLASH (6.4%-2.7%). Total dose accuracy suggests consistent pulse dose and pulse number, although these were not specifically assessed. Positioning variability was observed, likely due to the absence of robust positioning aids or image guidance. CONCLUSIONS: This study marks the first dosimetric audit for FLASH using a nonhomogeneous phantom, challenging conventional calibration practices reliant on homogeneous phantoms. The comparison protocol offers a framework for credentialing multi-institutional studies in FLASH preclinical research to enhance reproducibility of biologic findings.
Assuntos
Pulmão , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Animais , Camundongos , Pulmão/efeitos da radiação , Pulmão/diagnóstico por imagem , Radiometria/métodos , Dosagem Radioterapêutica , Poliésteres , Elétrons , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/efeitos da radiação , Poliestirenos , Resinas Acrílicas , ButadienosRESUMO
We conducted a multi-institutional audit of dosimetric variability between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3D-printed mouse phantom. A CT scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene ($~1.02 g/cm^3$) and polylactic acid ($~1.24 g/cm^3$) simultaneously to simulate soft tissue and bone densities, respectively. The lungs were printed separately using lightweight polylactic acid ($~0.64 g/cm^3$). Hounsfield units (HU) and densities were compared with the reference CT scan of the live mouse. Print-to-print reproducibility of the phantom was assessed. Three institutions were each provided a phantom, and each institution performed two replicates of irradiations at selected mouse anatomic regions. The average dose difference between FLASH and CONV dose distributions and deviation from the prescribed dose were measured with radiochromic film. Compared to the reference CT scan, CT scans of the phantom demonstrated mass density differences of $0.10 g/cm^3$ for bone, $0.12 g/cm^3$ for lung, and $0.03 g/cm^3$ for soft tissue regions. Between phantoms, the difference in HU for soft tissue and bone was <10 HU from print to print. Lung exhibited the most variation (54 HU) but minimally affected dose distribution (<0.5% dose differences between phantoms). The mean difference between FLASH and CONV from the first replicate to the second decreased from 4.3% to 1.2%, and the mean difference from the prescribed dose decreased from 3.6% to 2.5% for CONV and 6.4% to 2.7% for FLASH. The framework presented here is promising for credentialing of multi-institutional studies of FLASH preclinical research to maximize the reproducibility of biological findings.