RESUMO
Background: The effect of tibial fixation on the movement of the talus during the tibiotarsal axial traction technique (TATT) is unknown. The aim was to evaluate the effect on the tibiotarsus when applying three different intensities of TATT force with or without tibial fixation in healthy subjects, and to assess the reliability of detecting the different forces applied. Also, the discomfort generated during the technique would be analysed. Methods: A cross-sectional study was conducted in thirty lower limbs. Three magnitudes of TATT force in an open-packed position were applied in tibial fixation and non-fixation conditions. The axial traction movement was measured by ultrasound, and the magnitudes of the force applied during low-medium and high TATT force were recorded in both conditions. Patients were asked about the level of discomfort perceived during the technique. Results: The most significant distance increase (mm) was observed in the tibial fixation condition at all magnitudes of the TATT (F = 102.693, p < 0.001). The discomfort sensation (numeric rating scale, "NRS") was higher in the non-fixation condition (p > 0.05). The application of the technique showed good reliability (>0.75 ICC) for the detection of the applied force. Conclusions: The TATT in the tibial fixation condition produced more significant axial movement of the talus (mm) relative to the tibia than the non-tibial fixation condition did. The detection of the magnitudes of movement showed good reliability (ICC: 0.75 to 0.92). The technique was well tolerated at all force magnitudes, with the tibial fixation condition being the most tolerable.
RESUMO
BACKGROUND: The effect of load distribution applied to the trunk musculature with lunge exercises has yet to be determined. The aim of this study was to evaluate the effect of load placement using dumbbells on the activation of the latissimus dorsi, erector spinae, external oblique, and rectus abdominis muscles during the lunge. METHODS: Forty-two amateur athletes (21 men and 21 women) were recruited. Three lunge exercises were performed with different loading arrangements (ipsilateral, contralateral, and bilateral). The principal variable recorded for muscle activity was mean "root mean square" expressed as the percentage of the maximal voluntary isometric contraction. RESULTS: There are statistically significant differences in the erector spinae (p < 0.001; p < 0.003) and external oblique muscles (p < 0.009; p < 0.001) compared with the contralateral side. The muscle on the opposite side of the load achieved higher activation for these muscles. The erector spinae and latissimus dorsi muscle did not reach a statistically significant difference with the contralateral side in any exercise (p > 0.05). The higher activation of the latissimus dorsi occurred on the same side on which the load was placed. CONCLUSIONS: There was higher activation of the erector spinae, external oblique, and rectus abdominis muscles contralateral to the side of load placement during lunge exercise by amateur athletes.
RESUMO
Capacitive-resistive energy transfer therapy (CRet) is used to improve the rehabilitation of different injuries. This study aimed to evaluate and compare the changes in temperature and current flow during different CRet applications on upper and lower molars and incisors, with and without implants, on ten cryopreserved corpses. Temperatures were taken on molars and incisors with invasive devices and skin temperature was taken with a digital thermometer at the beginning and after treatments. Four interventions: 15 VA capacitive hypothermic (CAPH), 8 watts resistive (RES8), 20 watts resistive (RES20) and 75 VA capacitive (CAP75) were performed for 5 min each. All treatments in this study generated current flow (more than 0.00005 A/m2) and did not generate a significant temperature increase (p > 0.05). However, RES20 application slightly increased surface temperature on incisors without implants (p = 0.010), and molar with (p = 0.001) and without implant (p = 0.008). Also, CAP75 application increased surface temperature on molars with implant (p = 0.002) and upper incisor with implant (p = 0.001). In conclusion, RES8 and CAPH applications seem to be the best options to achieve current flow without an increase in temperature on molars and incisors with and without implants.