Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res ; 26(1): 85, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807211

RESUMO

BACKGROUND: Abbreviated breast MRI (FAST MRI) is being introduced into clinical practice to screen women with mammographically dense breasts or with a personal history of breast cancer. This study aimed to optimise diagnostic accuracy through the adaptation of interpretation-training. METHODS: A FAST MRI interpretation-training programme (short presentations and guided hands-on workstation teaching) was adapted to provide additional training during the assessment task (interpretation of an enriched dataset of 125 FAST MRI scans) by giving readers feedback about the true outcome of each scan immediately after each scan was interpreted (formative assessment). Reader interaction with the FAST MRI scans used developed software (RiViewer) that recorded reader opinions and reading times for each scan. The training programme was additionally adapted for remote e-learning delivery. STUDY DESIGN: Prospective, blinded interpretation of an enriched dataset by multiple readers. RESULTS: 43 mammogram readers completed the training, 22 who interpreted breast MRI in their clinical role (Group 1) and 21 who did not (Group 2). Overall sensitivity was 83% (95%CI 81-84%; 1994/2408), specificity 94% (95%CI 93-94%; 7806/8338), readers' agreement with the true outcome kappa = 0.75 (95%CI 0.74-0.77) and diagnostic odds ratio = 70.67 (95%CI 61.59-81.09). Group 1 readers showed similar sensitivity (84%) to Group 2 (82% p = 0.14), but slightly higher specificity (94% v. 93%, p = 0.001). Concordance with the ground truth increased significantly with the number of FAST MRI scans read through the formative assessment task (p = 0.002) but by differing amounts depending on whether or not a reader had previously attended FAST MRI training (interaction p = 0.02). Concordance with the ground truth was significantly associated with reading batch size (p = 0.02), tending to worsen when more than 50 scans were read per batch. Group 1 took a median of 56 seconds (range 8-47,466) to interpret each FAST MRI scan compared with 78 (14-22,830, p < 0.0001) for Group 2. CONCLUSIONS: Provision of immediate feedback to mammogram readers during the assessment test set reading task increased specificity for FAST MRI interpretation and achieved high diagnostic accuracy. Optimal reading-batch size for FAST MRI was 50 reads per batch. Trial registration (25/09/2019): ISRCTN16624917.


Assuntos
Neoplasias da Mama , Curva de Aprendizado , Imageamento por Ressonância Magnética , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Estudos Prospectivos , Idoso , Sensibilidade e Especificidade , Interpretação de Imagem Assistida por Computador/métodos , Mama/diagnóstico por imagem , Mama/patologia
2.
Breast Cancer Res ; 24(1): 55, 2022 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907862

RESUMO

BACKGROUND: Abbreviated breast MRI (abMRI) is being introduced in breast screening trials and clinical practice, particularly for women with dense breasts. Upscaling abMRI provision requires the workforce of mammogram readers to learn to effectively interpret abMRI. The purpose of this study was to examine the diagnostic accuracy of mammogram readers to interpret abMRI after a single day of standardised small-group training and to compare diagnostic performance of mammogram readers experienced in full-protocol breast MRI (fpMRI) interpretation (Group 1) with that of those without fpMRI interpretation experience (Group 2). METHODS: Mammogram readers were recruited from six NHS Breast Screening Programme sites. Small-group hands-on workstation training was provided, with subsequent prospective, independent, blinded interpretation of an enriched dataset with known outcome. A simplified form of abMRI (first post-contrast subtracted images (FAST MRI), displayed as maximum-intensity projection (MIP) and subtracted slice stack) was used. Per-breast and per-lesion diagnostic accuracy analysis was undertaken, with comparison across groups, and double-reading simulation of a consecutive screening subset. RESULTS: 37 readers (Group 1: 17, Group 2: 20) completed the reading task of 125 scans (250 breasts) (total = 9250 reads). Overall sensitivity was 86% (95% confidence interval (CI) 84-87%; 1776/2072) and specificity 86% (95%CI 85-86%; 6140/7178). Group 1 showed significantly higher sensitivity (843/952; 89%; 95%CI 86-91%) and higher specificity (2957/3298; 90%; 95%CI 89-91%) than Group 2 (sensitivity = 83%; 95%CI 81-85% (933/1120) p < 0.0001; specificity = 82%; 95%CI 81-83% (3183/3880) p < 0.0001). Inter-reader agreement was higher for Group 1 (kappa = 0.73; 95%CI 0.68-0.79) than for Group 2 (kappa = 0.51; 95%CI 0.45-0.56). Specificity improved for Group 2, from the first 55 cases (81%) to the remaining 70 (83%) (p = 0.02) but not for Group 1 (90-89% p = 0.44), whereas sensitivity remained consistent for both Group 1 (88-89%) and Group 2 (83-84%). CONCLUSIONS: Single-day abMRI interpretation training for mammogram readers achieved an overall diagnostic performance within benchmarks published for fpMRI but was insufficient for diagnostic accuracy of mammogram readers new to breast MRI to match that of experienced fpMRI readers. Novice MRI reader performance improved during the reading task, suggesting that additional training could further narrow this performance gap.


Assuntos
Neoplasias da Mama , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Estudos Prospectivos , Sensibilidade e Especificidade
3.
Br J Radiol ; 96(1142): 20220280, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36488196

RESUMO

Despite its unparalleled sensitivity for aggressive breast cancer, breast MRI continually excites criticism for a specificity that lags behind that of modern mammographic techniques. Radiologists reporting breast MRI need to recognise the range of benign appearances on breast MRI to avoid unnecessary biopsy. This review summarises the reported diagnostic accuracy of breast MRI with particular attention to the technique's specificity, provides a referenced reporting strategy and discusses factors that compromise diagnostic confidence. We then present a pictorial review of benign findings on breast MRI. Enhancing radiological skills to discriminate malignant from benign findings will minimise false positive biopsies, enabling optimal use of multiparametric breast MRI for the benefit of screening clients and breast cancer patients.


Assuntos
Neoplasias da Mama , Mama , Humanos , Feminino , Sensibilidade e Especificidade , Mama/diagnóstico por imagem , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/patologia , Mamografia
4.
Eur J Radiol Open ; 6: 220-224, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31431906

RESUMO

AIM: FAST MRI is an abbreviated breast MRI technique, proposed as a screening tool for breast cancer. This study aims to explore how 'Think-Out-Loud' (TOL) methodology can effectively develop and shape training to interpret standard breast MRI on readers' learning experience. MATERIALS AND METHODS: TOL methodology asks people to speak their thoughts while performing a task; to say whatever they are looking at, thinking, doing, and feeling at each moment. It helps determine expectations and identify aspects of confusion. This methodology was adopted with two groups of image readers to develop training materials for FAST MRI interpretation.Eight image readers (readers); 4 NHS Breast Screening Programme (NHSBSP) breast MRI and mammogram readers (Group 1) and 4 NHSBSP mammogram readers who do not read breast MRI (Group 2) were audio and video recorded during training. Content analysis was undertaken. RESULTS: TOL was well received by the readers and allowed iterative development and refinement of a training package. Challenges relating to introducing new concepts and managing uncertainty were identified through the analysis of the TOL audio data. Additionally, Group 2 asked for more clarification than Group 1, of both the teaching materials and how to use the image-manipulation software. CONCLUSION: TOL methodology allowed effective training of both groups of readers. The iterative nature of individual training ensured production of user-friendly materials including frequently-asked-questions sheets. It allowed for each person to feel that their views were fully listened to and incorporated into the training package, allowing for training materials with high face validity.

5.
Br J Radiol ; 92(1104): 20190663, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31559859

RESUMO

OBJECTIVES: To assess whether NHS breast screening programme (NHSBSP) mammogram readers could effectively interpret first post-contrast acquisition subtracted (FAST) MRI, for intended use in screening for breast cancer. METHODS: Eight NHSBSP mammogram readers from a single centre (four who also read breast MRI (Group 1) and four who do not (Group 2)) were given structured FAST MRI reader training (median 4 h: 32 min). They then prospectively interpreted 125 FAST MRIs (250 breasts: 194 normal and 56 cancer) comprising a consecutive series of screening MRIs enriched with additional cancer cases from 2015, providing 2000 interpretations. Readers were blinded to other readers' opinions and to clinical information. Categorisation followed the NHSBSP MRI reporting categorisation, with categories 4 and 5 considered indicative of cancer. Diagnostic accuracy (reference standard: histology or 2 years' follow-up) and agreement between readers were determined. RESULTS: The accuracy achieved by Group 2 (847/1000 (85%; 95% confidence interval (CI) 82-87%)) was 5% less than that of Group 1 (898/1000 (90%; 95% CI 88-92)). Good inter-reader agreement was seen between both Group 1 readers (κ = 0.66; 95% CI 0.61-0.71) and Group 2 readers (κ = 0.63; 95% CI 0.58-0.68). The median time taken to interpret each FAST MRI was Group 1: 34 s (range 3-351) and Group 2: 77 s (range 11-321). CONCLUSION: Brief structured training enabled multiprofessional mammogram readers to achieve similar accuracy at FAST MRI interpretation to consultant radiologists experienced at breast MRI interpretation. ADVANCES IN KNOWLEDGE: FAST MRI could be feasible from a training-the-workforce perspective for screening within NHSBSP.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Confiabilidade dos Dados , Imageamento por Ressonância Magnética/métodos , Mamografia , Radiologistas/educação , Intervalos de Confiança , Meios de Contraste , Feminino , Humanos , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa