Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(17)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37687945

RESUMO

The SOI-FET biosensor (silicon-on-insulator field-effect transistor) for virus detection is a promising device in the fields of medicine, virology, biotechnology, and the environment. However, the applications of modern biosensors face numerous problems and require improvement. Some of these problems can be attributed to sensor design, while others can be attributed to technological limitations. The aim of this work is to conduct a theoretical investigation of the "antibody + antigen" complex (AB + AG) detection processes of a SOI-FET biosensor, which may also solve some of the aforementioned problems. Our investigation concentrates on the analysis of the probability of AB + AG complex detection and evaluation. Poisson probability density distribution was used to estimate the probability of the adsorption of the target molecules on the biosensor's surface and, consequently, to obtain correct detection results. Many implicit and unexpected causes of error detection have been identified for AB + AG complexes using SOI-FET biosensors. We showed that accuracy and time of detection depend on the number of SOI-FET biosensors on a crystal.


Assuntos
Biotecnologia , Silício , Adsorção , Probabilidade
2.
Biosensors (Basel) ; 12(11)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36354501

RESUMO

Quick label-free virus screening and highly sensitive analytical tools/techniques are becoming extremely important in a pandemic. In this study, we developed a biosensing device based on the silicon nanoribbon multichannel and dielectrophoretic controlled sensors functionalized with SARS-CoV-2 spike antibodies for the use as a platform for the detection and studding of properties of viruses and their protein components. Replicatively defective viral particles based on vesicular stomatitis viruses and HIV-1 were used as carrier molecules to deliver the target SARS-CoV-2 spike S-proteins to sensory elements. It was shown that fully CMOS-compatible nanoribbon sensors have the subattomolar sensitivity and dynamic range of 4 orders. Specific interaction between S-proteins and antibodies leads to the accumulation of the negative charge on the sensor surface. Nonspecific interactions of the viral particles lead to the positive charge accumulation. It was shown that dielectrophoretic controlled sensors allow to estimate the effective charge of the single virus at the sensor surface and separate it from the charge associated with the binding of target proteins with the sensor surface.


Assuntos
Técnicas Biossensoriais , COVID-19 , Nanotubos de Carbono , Humanos , SARS-CoV-2 , Técnicas Biossensoriais/métodos , Pandemias , Anticorpos Antivirais
3.
Biosensors (Basel) ; 11(4)2021 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-33921281

RESUMO

The detection of influenza A virions with a nanoribbon detector (NR detector) has been demonstrated. Chips for the detector have been fabricated based on silicon-on-insulator nanoribbon structures (SOI nanoribbon chip), using a complementary metal-oxide-semiconductor (CMOS)-compatible technology-by means of gas-phase etching and standard optical photolithography. The surface of the SOI nanoribbon chip contains a matrix of 10 nanoribbon (NR) sensor elements. SOI nanoribbon chips of n-type conductance have been used for this study. For biospecific detection of target particles, antibodies against influenza virus have been covalently immobilized onto NRs. Influenza A virus detection was performed by real-time registration of the source-drain current through the NRs. The detection of the target viral particles was carried out in buffer solutions at the target particles concentration within the range from 107 to 103 viral particles per milliliter (VP/mL). The lowest detectable concentration of the target viral particles was 6 × 10-16 M (corresponding to 104 VP/mL). The use of solutions containing ~109 to 1010 VP/mL resulted in saturation of the sensor surface with the target virions. In the saturation mode, detection was impossible.


Assuntos
Técnicas Biossensoriais , Orthomyxoviridae/isolamento & purificação , Transistores Eletrônicos , Nanotubos de Carbono , Nanofios , Análise de Sequência com Séries de Oligonucleotídeos , Óxidos , Semicondutores , Silício
4.
J Pers Med ; 10(3)2020 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-32635670

RESUMO

Hemorheological disorders in structural and functional parameters of erythrocytes are involved in the pathological process in type 2 diabetes mellitus (DM). AIM: to investigate the feasibility of differential diagnosis of the degrees of rheological disturbances in patients with type 2 DM by dielectrophoresis of erythrocytes. METHODS: 62 subjects (58.7 ± 1.6 years) with type 2 DM diagnosed according to the criteria of the ADA were subdivided into two groups: medium (n = 47) and high (n = 15) risk of microcirculatory disturbances (EASD, 2013). Electric and viscoelastic parameters of erythrocytes were determined by dielectrophoresis using an electric optical system of cell detection. RESULTS: the progression of rheological disturbances in the patients with type 2 DM was accompanied by significant decreases in deformation amplitude; dipole moment; polarizability; and membrane capacity; and increases in conductivity, viscosity, rigidity, hemolysis, and formation of aggregates (p < 0.05). Combined use of the parameters increased sensitivity (97.8%) and specificity (86.7%) for diagnosis of rheological disturbances in type 2 DM. CONCLUSION: the proposed experimental approach possesses low invasiveness, high productivity, shorter duration, vividness of the results. The method allows to evaluate not only local (renal and ocular) but also systemic status of microcirculation using more than 20 parameters of erythrocytes.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa