Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Proteome Res ; 17(2): 770-779, 2018 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-28901143

RESUMO

A novel data-independent acquisition (DIA) method incorporating a scanning quadrupole in front of a collision cell and orthogonal acceleration time-of-flight mass analyzer is described. The method has been characterized for the qualitative and quantitative label-free proteomic analysis of complex biological samples. The principle of the scanning quadrupole DIA method is discussed, and analytical instrument characteristics, such as the quadrupole transmission width, scan/integration time, and chromatographic separation, have been optimized in relation to sample complexity for a number of different model proteomes of varying complexity and dynamic range including human plasma, cell lines, and bacteria. In addition, the technological merits over existing DIA approaches are described and contrasted. The qualitative and semiquantitative performance of the method is illustrated for the analysis of relatively simple protein digest mixtures and a well-characterized human cell line sample using untargeted and targeted search strategies. Finally, the results from a human cell line were compared against publicly available data that used similar chromatographic conditions but were acquired with DDA technology and alternative mass analyzer systems. Qualitative comparison showed excellent concordance of results with >90% overlap of the detected proteins.


Assuntos
Proteínas Sanguíneas/isolamento & purificação , Escherichia coli/química , Proteoma/isolamento & purificação , Proteômica/métodos , Sequência de Aminoácidos , Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Misturas Complexas/química , Células HeLa , Humanos , Células K562 , Proteólise , Proteômica/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
2.
J Proteome Res ; 17(2): 780-793, 2018 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-29251506

RESUMO

Calcineurin is a critical cell-signaling protein that orchestrates growth, stress response, virulence, and antifungal drug resistance in several fungal pathogens. Blocking calcineurin signaling increases the efficacy of several currently available antifungals and suppresses drug resistance. We demonstrate the application of a novel scanning quadrupole DIA method for the analysis of changes in the proteins coimmunoprecipitated with calcineurin during therapeutic antifungal drug treatments of the deadly human fungal pathogen Aspergillus fumigatus. Our experimental design afforded an assessment of the precision of the method as demonstrated by peptide- and protein-centric analysis from eight replicates of the study pool QC samples. Two distinct classes of clinically relevant antifungal drugs that are guideline recommended for the treatment of invasive "aspergillosis" caused by Aspergillus fumigatus, the azoles (voriconazole) and the echinocandins (caspofungin and micafungin), which specifically target the fungal plasma membrane and the fungal cell wall, respectively, were chosen to distinguish variations occurring in the proteins coimmunoprecipitated with calcineurin. Novel potential interactors were identified in response to the different drug treatments that are indicative of the possible role for calcineurin in regulating these effectors. Notably, treatment with voriconazole showed increased immunoprecipitation of key proteins involved in membrane ergosterol biosynthesis with calcineurin. In contrast, echinocandin (caspofungin or micafungin) treatments caused increased immunoprecipitation of proteins involved in cell-wall biosynthesis and septation. Furthermore, abundant coimmunoprecipitation of ribosomal proteins with calcineurin occurred exclusively in echinocandins treatment, indicating reprogramming of cellular growth mechanisms during different antifungal drug treatments. While variations in the observed calcineurin immunoprecipitated proteins may also be due to changes in their expression levels under different drug treatments, this study suggests an important role for calcineurin-dependent cellular mechanisms in response to antifungal treatment of A. fumigatus that warrants future studies.


Assuntos
Aspergillus fumigatus/efeitos dos fármacos , Calcineurina/isolamento & purificação , Proteínas Fúngicas/isolamento & purificação , Proteínas Ribossômicas/isolamento & purificação , Voriconazol/farmacologia , Antifúngicos/farmacologia , Aspergillus fumigatus/química , Aspergillus fumigatus/genética , Aspergillus fumigatus/metabolismo , Calcineurina/genética , Calcineurina/metabolismo , Caspofungina , Membrana Celular/química , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Parede Celular/química , Parede Celular/efeitos dos fármacos , Parede Celular/metabolismo , Cromatografia Líquida/métodos , Equinocandinas/farmacologia , Ergosterol/biossíntese , Proteínas Fúngicas/genética , Proteínas Fúngicas/metabolismo , Expressão Gênica , Ontologia Genética , Genes Reporter , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Imunoprecipitação , Lipopeptídeos/farmacologia , Micafungina , Anotação de Sequência Molecular , Ligação Proteica , Mapeamento de Interação de Proteínas , Proteínas Ribossômicas/genética , Proteínas Ribossômicas/metabolismo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
3.
Proteomics ; 16(15-16): 2284-301, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27296928

RESUMO

In proteomics studies, it is generally accepted that depth of coverage and dynamic range is limited in data-directed acquisitions. The serial nature of the method limits both sensitivity and the number of precursor ions that can be sampled. To that end, a number of data-independent acquisition (DIA) strategies have been introduced with these methods, for the most part, immune to the sampling issue; nevertheless, some do have other limitations with respect to sensitivity. The major limitation with DIA approaches is interference, i.e., MS/MS spectra are highly chimeric and often incapable of being identified using conventional database search engines. Utilizing each available dimension of separation prior to ion detection, we present a new multi-mode acquisition (MMA) strategy multiplexing both narrowband and wideband DIA acquisitions in a single analytical workflow. The iterative nature of the MMA workflow limits the adverse effects of interference with minimal loss in sensitivity. Qualitative identification can be performed by selected ion chromatograms or conventional database search strategies.


Assuntos
Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Software
4.
Anal Chem ; 87(2): 1137-44, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25495617

RESUMO

Despite recent advances in analytical and computational chemistry, lipid identification remains a significant challenge in lipidomics. Ion-mobility spectrometry provides an accurate measure of the molecules' rotationally averaged collision cross-section (CCS) in the gas phase and is thus related to ionic shape. Here, we investigate the use of CCS as a highly specific molecular descriptor for identifying lipids in biological samples. Using traveling wave ion mobility mass spectrometry (MS), we measured the CCS values of over 200 lipids within multiple chemical classes. CCS values derived from ion mobility were not affected by instrument settings or chromatographic conditions, and they were highly reproducible on instruments located in independent laboratories (interlaboratory RSD < 3% for 98% of molecules). CCS values were used as additional molecular descriptors to identify brain lipids using a variety of traditional lipidomic approaches. The addition of CCS improved the reproducibility of analysis in a liquid chromatography-MS workflow and maximized the separation of isobaric species and the signal-to-noise ratio in direct-MS analyses (e.g., "shotgun" lipidomics and MS imaging). These results indicate that adding CCS to databases and lipidomics workflows increases the specificity and selectivity of analysis, thus improving the confidence in lipid identification compared to traditional analytical approaches. The CCS/accurate-mass database described here is made publicly available.


Assuntos
Encéfalo/metabolismo , Lipídeos/análise , Espectrometria de Massa de Íon Secundário/métodos , Idoso , Cromatografia Líquida , Humanos , Razão Sinal-Ruído
5.
Anal Bioanal Chem ; 407(17): 4995-5007, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25893801

RESUMO

The high chemical complexity of the lipidome is one of the major challenges in lipidomics research. Ion-mobility spectrometry (IMS), a gas-phase electrophoretic technique, makes possible the separation of ions in the gas phase according to their charge, shape, and size. IMS can be combined with mass spectrometry (MS), adding three major benefits to traditional lipidomic approaches. First, IMS-MS allows the determination of the collision cross section (CCS), a physicochemical measure related to the conformational structure of lipid ions. The CCS is used to improve the confidence of lipid identification. Second, IMS-MS provides a new set of hybrid fragmentation experiments. These experiments, which combine collision-induced dissociation with ion-mobility separation, improve the specificity of MS/MS-based approaches. Third, IMS-MS improves the peak capacity and signal-to-noise ratio of traditional analytical approaches. In doing so, it allows the separation of complex lipid extracts from interfering isobaric species. Developing in parallel with advances in instrumentation, informatics solutions enable analysts to process and exploit IMS-MS data for qualitative and quantitative applications. Here we review the current approaches for lipidomics research based on IMS-MS, including liquid chromatography-MS and direct-MS analyses of "shotgun" lipidomics and MS imaging.


Assuntos
Cromatografia Líquida/métodos , Lipídeos/análise , Espectrometria de Massas/métodos , Animais , Humanos , Íons/análise , Metabolômica/métodos , Modelos Moleculares
6.
BMC Bioinformatics ; 14: 364, 2013 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-24341404

RESUMO

BACKGROUND: The goal of many proteomics experiments is to determine the abundance of proteins in biological samples, and the variation thereof in various physiological conditions. High-throughput quantitative proteomics, specifically label-free LC-MS/MS, allows rapid measurement of thousands of proteins, enabling large-scale studies of various biological systems. Prior to analyzing these information-rich datasets, raw data must undergo several computational processing steps. We present a method to address one of the essential steps in proteomics data processing--the matching of peptide measurements across samples. RESULTS: We describe a novel method for label-free proteomics data alignment with the ability to incorporate previously unused aspects of the data, particularly ion mobility drift times and product ion information. We compare the results of our alignment method to PEPPeR and OpenMS, and compare alignment accuracy achieved by different versions of our method utilizing various data characteristics. Our method results in increased match recall rates and similar or improved mismatch rates compared to PEPPeR and OpenMS feature-based alignment. We also show that the inclusion of drift time and product ion information results in higher recall rates and more confident matches, without increases in error rates. CONCLUSIONS: Based on the results presented here, we argue that the incorporation of ion mobility drift time and product ion information are worthy pursuits. Alignment methods should be flexible enough to utilize all available data, particularly with recent advancements in experimental separation methods.


Assuntos
Modelos Genéticos , Fragmentos de Peptídeos/química , Proteômica/métodos , Alinhamento de Sequência/métodos , Espectrometria de Massas por Ionização por Electrospray , Proteínas de Ligação a DNA/química , Proteínas de Ligação a DNA/genética , Proteínas de Escherichia coli/química , Proteínas de Escherichia coli/genética , Hepatite C/genética , Hepatite C/metabolismo , Humanos , Íons/química , Osteoartrite/genética , Osteoartrite/metabolismo , Fragmentos de Peptídeos/genética , Proteômica/estatística & dados numéricos , Alinhamento de Sequência/estatística & dados numéricos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
7.
Anal Bioanal Chem ; 404(4): 1127-39, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22811061

RESUMO

To accurately determine the quantitative change of peptides and proteins in complex proteomics samples requires knowledge of how well each ion has been measured. The precision of each ions' calculated area is predicated on how uniquely it occupies its own space in m/z and elution time. Given an initial assumption that prior to the addition of the "heavy" label, all other ion detections are unique, which is arguably untrue, an initial attempt at quantifying the pervasiveness of ion interference events in a representative binary SILAC experiment was made by comparing the centered m/z and retention time of the ion detections from the "light" variant to its "heavy" companion. Ion interference rates were determined for LC-MS data acquired at mass resolving powers of 20 and 40 K with and without ion mobility separation activated. An ion interference event was recorded, if present in the companion dataset was an ion within ± its Δ mass at half-height, ±15 s of its apex retention time and if utilized by ±1 drift bin. Data are presented illustrating a definitive decrease in the frequency of ion interference events with each additional increase in selectivity of the analytical workflow. Regardless of whether the quantitative experiment is a composite of labeled samples or label free, how well each ion is measured can be determined given knowledge of the instruments mass resolving power across the entire m/z scale and the ion detection algorithm reporting both the centered m/z and Δ mass at half-height for each detected ion. Given these measurements, an effective resolution can be calculated and compared with the expected instrument performance value providing a purity score for the calculated ions' area based on mass resolution. Similarly, chromatographic and drift purity scores can be calculated. In these instances, the error associated to an ions' calculated peak area is estimated by examining the variation in each measured width to that of their respective experimental median. Detail will be disclosed as to how a final ion purity score was established, providing a first measure of how accurately each ions' area was determined as well as how precise the calculated quantitative change between labeled or unlabelled pairs were determined. Presented is how common ion interference events are in quantitative proteomics LC-MS experiments and how ion purity filters can be utilized to overcome and address them, providing ultimately more accurate and precise quantification results across a wider dynamic range.


Assuntos
Espectrometria de Massas/normas , Proteínas/química , Proteômica/normas , Algoritmos , Proteínas de Caenorhabditis elegans/química , Linhagem Celular Tumoral , Humanos , Espectrometria de Massas/métodos , Peptídeos/química , Proteômica/métodos , Proteínas de Saccharomyces cerevisiae/química
8.
Proteomics ; 11(6): 1189-211, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21298790

RESUMO

The computational simulation of complete proteomic data sets and their utility to validate detection and interpretation algorithms, to aid in the design of experiments and to assess protein and peptide false discovery rates is presented. The simulation software has been developed for emulating data originating from data-dependent and data-independent LC-MS workflows. Data from all types of commonly used hybrid mass spectrometers can be simulated. The algorithms are based on empirically derived physicochemical liquid and gas phase models for proteins and peptides. Sample composition in terms of complexity and dynamic range, as well as chromatographic, experimental and MS conditions, can be controlled and adjusted independently. The effect of on-column amounts, gradient length, mass resolution and ion mobility on search specificity will be demonstrated using tryptic peptides from human and yeast cellular lysates simulated over five orders of magnitude in dynamic range. Initial justification of the simulated data sets is achieved by comparing and contrasting the in silico simulated data to experimentally derived results from a 48 protein mixture, spanning a similar magnitude of five orders of magnitude. Additionally, experimental data from replicate and dilutions series experiments will be utilized to determine error rates at the peptide and protein level with respect to mass, area, retention and drift time. The data presented reveal a high degree of similarity at the ion detection, peptide and protein level when analyzed under similar conditions.


Assuntos
Proteômica/estatística & dados numéricos , Algoritmos , Cromatografia Líquida , Biologia Computacional , Simulação por Computador , Bases de Dados de Proteínas/estatística & dados numéricos , Células HeLa , Humanos , Peptídeos/isolamento & purificação , Proteínas/isolamento & purificação , Proteômica/normas , Controle de Qualidade , Proteínas de Saccharomyces cerevisiae/isolamento & purificação , Ferramenta de Busca , Espectrometria de Massas em Tandem/estatística & dados numéricos , Fluxo de Trabalho
9.
J Proteome Res ; 10(5): 2318-29, 2011 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-21417239

RESUMO

A new method for enhancing peptide ion identification in proteomics analyses using ion mobility data is presented. Ideally, direct comparisons of experimental drift times (t(D)) with a standard mobility database could be used to rank candidate peptide sequence assignments. Such a database would represent only a fraction of sequences in protein databases and significant difficulties associated with the verification of data for constituent peptide ions would exist. A method that employs intrinsic amino acid size parameters to obtain ion mobility predictions that can be used to rank candidate peptide ion assignments is proposed. Intrinsic amino acid size parameters have been determined for doubly charged peptide ions from an annotated yeast proteome. Predictions of ion mobilities using the intrinsic size parameters are more accurate than those obtained from a polynomial fit to t(D) versus molecular weight data. More than a 2-fold improvement in prediction accuracy has been observed for a group of arginine-terminated peptide ions 12 residues in length. The use of this predictive enhancement as a means to aid peptide ion identification is discussed, and a simple peptide ion scoring scheme is presented.


Assuntos
Aminoácidos/metabolismo , Peptídeos/análise , Proteômica/métodos , Cromatografia Líquida , Transporte de Íons/fisiologia , Espectrometria de Massas , Projetos de Pesquisa
10.
Anal Chem ; 83(18): 6971-9, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21834580

RESUMO

Many software tools have been developed for analyzing stable isotope labeling (SIL)-based quantitative proteomic data using data dependent acquisition (DDA). However, programs for analyzing SIL-based quantitative proteomics data obtained with data independent acquisition (DIA) have yet to be reported. Here, we demonstrated the development of a new software for analyzing SIL data using the DIA method. Performance of the DIA on SYNAPT G2MS was evaluated using SIL-labeled complex proteome mixtures with known heavy/light ratios (H/L = 1:1, 1:5, and 1:10) and compared with the DDA on linear ion trap (LTQ)-Orbitrap MS. The DIA displays relatively high quantitation accuracy for peptides cross all intensity regions, while the DDA shows an intensity dependent distribution of H/L ratios. For the three proteome mixtures, the number of detected SIL-peptide pairs and dynamic range of protein intensities using DIA drop stepwise, whereas no significant changes in these aspects using DDA were observed. The new software was applied to investigate the proteome difference between mouse embryonic fibroblasts (MEFs) and MEF-derived induced pluripotent stem cells (iPSCs) using (16)O/(18)O labeling. Our study expanded the capacities of our UNiquant software pipeline and provided valuable insight into the performance of the two cutting-edge MS platforms for SIL-based quantitative proteomic analysis today.


Assuntos
Marcação por Isótopo/métodos , Proteoma/análise , Proteômica/métodos , Software , Animais , Linhagem Celular , Cromatografia Líquida de Alta Pressão/métodos , Fibroblastos/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Espectrometria de Massas/métodos , Camundongos , Isótopos de Oxigênio/química , Peptídeos/análise
11.
Proteomics ; 9(6): 1696-719, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19294629

RESUMO

A novel database search algorithm is presented for the qualitative identification of proteins over a wide dynamic range, both in simple and complex biological samples. The algorithm has been designed for the analysis of data originating from data independent acquisitions, whereby multiple precursor ions are fragmented simultaneously. Measurements used by the algorithm include retention time, ion intensities, charge state, and accurate masses on both precursor and product ions from LC-MS data. The search algorithm uses an iterative process whereby each iteration incrementally increases the selectivity, specificity, and sensitivity of the overall strategy. Increased specificity is obtained by utilizing a subset database search approach, whereby for each subsequent stage of the search, only those peptides from securely identified proteins are queried. Tentative peptide and protein identifications are ranked and scored by their relative correlation to a number of models of known and empirically derived physicochemical attributes of proteins and peptides. In addition, the algorithm utilizes decoy database techniques for automatically determining the false positive identification rates. The search algorithm has been tested by comparing the search results from a four-protein mixture, the same four-protein mixture spiked into a complex biological background, and a variety of other "system" type protein digest mixtures. The method was validated independently by data dependent methods, while concurrently relying on replication and selectivity. Comparisons were also performed with other commercially and publicly available peptide fragmentation search algorithms. The presented results demonstrate the ability to correctly identify peptides and proteins from data independent acquisition strategies with high sensitivity and specificity. They also illustrate a more comprehensive analysis of the samples studied; providing approximately 20% more protein identifications, compared to a more conventional data directed approach using the same identification criteria, with a concurrent increase in both sequence coverage and the number of modified peptides.


Assuntos
Misturas Complexas/análise , Bases de Dados de Proteínas , Peptídeos/análise , Algoritmos , Sequência de Aminoácidos , Dados de Sequência Molecular , Peso Molecular , Processamento de Proteína Pós-Traducional , Proteínas/química , Proteoma/análise , Curva ROC , Fatores de Tempo
12.
Proteomics ; 9(6): 1683-95, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19294628

RESUMO

The detection, correlation, and comparison of peptide and product ions from a data independent LC-MS acquisition strategy with data dependent LC-MS/MS is described. The data independent mode of acquisition differs from an LC-MS/MS data acquisition since no ion transmission window is applied with the first mass analyzer prior to collision induced disassociation. Alternating the energy applied to the collision cell, between low and elevated energy, on a scan-to-scan basis, provides accurate mass precursor and associated product ion spectra from every ion above the LOD of the mass spectrometer. The method therefore provides a near 100% duty cycle, with an inherent increase in signal intensity due to the fact that both precursor and product ion data are collected on all isotopes of every charge-state across the entire chromatographic peak width. The correlation of product to precursor ions, after deconvolution, is achieved by using reconstructed retention time apices and chromatographic peak shapes. Presented are the results from the comparison of a simple four protein mixture, in the presence and absence of an enzymatically digested protein extract from Escherichia coli. The samples were run in triplicate by both data dependant analysis (DDA) LC-MS/MS and data-independent, alternate scanning LC-MS. The detection and identification of precursor and product ions from the combined DDA search results of the four protein mixture were used for comparison to all other data. Each individual set of data-independent LC-MS data provides a more comprehensive set of detected ions than the combined peptide identifications from the DDA LC-MS/MS experiments. In the presence of the complex E. coli background, over 90% of the monoisotopic masses from the combined LC-MS/MS identifications were detected at the appropriate retention time. Moreover, the fragmentation pattern and number of associated elevated energy product ions in each replicate experiment was found to be very similar to the DDA identifications. In the case of the corresponding individual DDA LC-MS/MS experiment, 43% of the possible detectable peptides of interest were identified. The presented data illustrates that the time-aligned data from data-independent alternate scanning LC-MS experiments is highly comparable to the data obtained via DDA. The obtained information can therefore be effectively and correctly deconvolved to correlate product ions with parent precursor ions. The ability to generate precursor-product ion tables from this information and subsequently identify the correct parent precursor peptide will be illustrated in a companion manuscript.


Assuntos
Espectrometria de Massas , Peptídeos/análise , Sequência de Aminoácidos , Cromatografia Líquida , Dados de Sequência Molecular , Peptídeos/química , Proteínas/análise , Reprodutibilidade dos Testes , Fatores de Tempo , Tripsina/metabolismo
13.
Electrophoresis ; 30(7): 1157-67, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19283699

RESUMO

1-D and 2-D LC methods were utilized for proteome analysis of undepleted human serum. Separation of peptides in 2-D LC was performed either with strong cation exchange (SCX)-RP chromatography or with an RP-RP 2-D LC approach. Peptides were identified by MS/MS using a data-independent acquisition approach. A peptide retention prediction model was used to highlight the potential false-positive peptide identifications. When applying selected data filtration, we identified 52 proteins based on 316 peptides in serum in 1-D LC setup. One hundred and eighty-four proteins/1036 peptides and 142 proteins/905 peptides were identified in RP-RP and SCX-RP 2-D LC, respectively. The performance of both 2-D LC methods for proteomic analysis is critically compared.


Assuntos
Cromatografia Líquida/métodos , Peptídeos/sangue , Proteoma/análise , Espectrometria de Massas em Tandem/métodos , Eletrocromatografia Capilar/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia por Troca Iônica/métodos , Humanos
14.
Sci Rep ; 7(1): 17146, 2017 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-29215067

RESUMO

The symptoms of malaria are brought about by blood-stage parasites, which are established when merozoites invade human erythrocytes. Our understanding of the molecular events that underpin erythrocyte invasion remains hampered by the short-period of time that merozoites are invasive. To address this challenge, a Plasmodium falciparum gamma-irradiated long-lived merozoite (LLM) line was developed and investigated. Purified LLMs invaded erythrocytes by an increase of 10-300 fold compared to wild-type (WT) merozoites. Using an integrated omics approach, we investigated the basis for the phenotypic difference. Only a few single nucleotide polymorphisms within the P. falciparum genome were identified and only marginal differences were observed in the merozoite transcriptomes. By contrast, using label-free quantitative mass-spectrometry, a significant change in protein abundance was noted, of which 200 were proteins of unknown function. We determined the relative molar abundance of over 1100 proteins in LLMs and further characterized the major merozoite surface protein complex. A unique processed MSP1 intermediate was identified in LLM but not observed in WT suggesting that delayed processing may be important for the observed phenotype. This integrated approach has demonstrated the significant role of the merozoite proteome during erythrocyte invasion, while identifying numerous unknown proteins likely to be involved in invasion.


Assuntos
Eritrócitos/metabolismo , Malária Falciparum/metabolismo , Merozoítos/metabolismo , Plasmodium falciparum/metabolismo , Proteoma , Proteínas de Protozoários/metabolismo , Transcriptoma , Animais , Eritrócitos/parasitologia , Humanos , Malária Falciparum/genética , Malária Falciparum/parasitologia , Merozoítos/genética , Plasmodium falciparum/genética , Plasmodium falciparum/isolamento & purificação , Proteínas de Protozoários/genética
15.
J Am Soc Mass Spectrom ; 23(10): 1808-20, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22847389

RESUMO

The functional design and application of a data-independent LC-MS precursor and product ion repository for protein identification, quantification, and validation is conceptually described. The ion repository was constructed from the sequence search results of a broad range of discovery experiments investigating various tissue types of two closely related mammalian species. The relative high degree of similarity in protein complement, ion detection, and peptide and protein identification allows for the analysis of normalized precursor and product ion intensity values, as well as standardized retention times, creating a multidimensional/orthogonal queryable, qualitative, and quantitative space. Peptide ion map selection for identification and quantification is primarily based on replication and limited variation. The information is stored in a relational database and is used to create peptide- and protein-specific fragment ion maps that can be queried in a targeted fashion against the raw or time aligned ion detections. These queries can be conducted either individually or as groups, where the latter affords pathway and molecular machinery analysis of the protein complement. The presented results also suggest that peptide ionization and fragmentation efficiencies are highly conserved between experiments and practically independent of the analyzed biological sample when using similar instrumentation. Moreover, the data illustrate only minor variation in ionization efficiency with amino acid sequence substitutions occurring between species. Finally, the data and the presented results illustrate how LC-MS performance metrics can be extracted and utilized to ensure optimal performance of the employed analytical workflows.


Assuntos
Sistemas de Gerenciamento de Base de Dados , Bases de Dados de Proteínas , Espectrometria de Massas , Proteínas/química , Proteômica/métodos , Cromatografia Líquida , Íons/química , Peptídeos/química , Reprodutibilidade dos Testes
16.
Sci Signal ; 3(111): ra15, 2010 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-20197544

RESUMO

Exposing the brain to sublethal ischemia affects the response to a subsequent, otherwise injurious ischemia, resulting in transcriptional suppression and neuroprotection, a response called ischemic tolerance. Here, we show that the proteomic signature of the ischemic-tolerant brain is characterized by increased abundance of transcriptional repressors, particularly polycomb group (PcG) proteins. Knocking down PcG proteins precluded the induction of ischemic tolerance, whereas in an in vitro model, overexpressing the PcG proteins SCMH1 or BMI1 induced tolerance to ischemia without preconditioning. We found that PcG proteins are associated with the promoter regions of genes encoding two potassium channel proteins that show decreased abundance in ischemic-tolerant brains. Furthermore, PcG proteins decreased potassium currents in cultured neuronal cells, and knocking down potassium channels elicited tolerance without preconditioning. These findings reveal a previously unknown mechanism of neuroprotection that involves gene repressors of the PcG family.


Assuntos
Isquemia Encefálica/fisiopatologia , Proteínas Repressoras/genética , Proteínas Repressoras/fisiologia , Animais , Sequência de Bases , Isquemia Encefálica/genética , Epigênese Genética , Técnicas In Vitro , Canal de Potássio Kv1.5/genética , Canal de Potássio Kv1.5/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fármacos Neuroprotetores/metabolismo , Proteínas Nucleares/genética , Complexo Repressor Polycomb 1 , Proteínas do Grupo Polycomb , Regiões Promotoras Genéticas , Proteômica , Proteínas Proto-Oncogênicas/genética , RNA Interferente Pequeno/genética , Proteínas Repressoras/antagonistas & inibidores , Superfamília Shaker de Canais de Potássio/genética , Superfamília Shaker de Canais de Potássio/metabolismo , Transdução de Sinais
17.
PLoS One ; 5(12): e14214, 2010 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-21151894

RESUMO

BACKGROUND AND METHODOLOGY: Pancreatic beta cells show intercellular differences in their metabolic glucose sensitivity and associated activation of insulin production. To identify protein markers for these variations in functional glucose sensitivity, rat beta cell subpopulations were flow-sorted for their level of glucose-induced NAD(P)H and their proteomes were quantified by label-free data independent alternate scanning LC-MS. Beta cell-selective proteins were also identified through comparison with rat brain and liver tissue and with purified islet alpha cells, after geometrical normalization using 6 stably expressed reference proteins. PRINCIPAL FINDINGS: All tissues combined, 943 proteins were reliably quantified. In beta cells, 93 out of 467 quantifiable proteins were uniquely detected in this cell type; several other proteins presented a high molar abundance in beta cells. The proteome of the beta cell subpopulation with high metabolic and biosynthetic responsiveness to 7.5 mM glucose was characterized by (i) an on average 50% higher expression of protein biosynthesis regulators such as 40S and 60S ribosomal constituents, NADPH-dependent protein folding factors and translation elongation factors; (ii) 50% higher levels of enzymes involved in glycolysis and in the cytosolic arm of the malate/aspartate-NADH-shuttle. No differences were noticed in mitochondrial enzymes of the Krebs cycle, beta-oxidation or respiratory chain. CONCLUSIONS: Quantification of subtle variations in the proteome using alternate scanning LC-MS shows that beta cell metabolic glucose responsiveness is mostly associated with higher levels of glycolytic but not of mitochondrial enzymes.


Assuntos
Glucose/metabolismo , Células Secretoras de Insulina/citologia , Insulina/biossíntese , Proteoma , Animais , Encéfalo/metabolismo , Cromatografia Líquida/métodos , Regulação da Expressão Gênica , Glicólise , Fígado/metabolismo , Espectrometria de Massas/métodos , Mitocôndrias/enzimologia , Proteômica/métodos , Ratos , Distribuição Tecidual
18.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(13): 1317-26, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18996061

RESUMO

An LC-MS-based approach is presented for the identification and quantification of proteins from unsequenced organisms. The method relies on the preservation of homology across species and the similarity in detection characteristics of proteomes in general. Species related proteomes share similarity that progresses from the amino acid frequency distribution to the complete amino sequence of matured proteins. Moreover, the comparative analysis between theoretical and experimental proteome distributions can be used as a measure for the correctness of detection and identification obtained through LC-MS-based schemes. Presented are means to the identification and quantification of rabbit myocardium proteins, immediately after inducing cardiac arrest, using a data-independent LC-MS acquisition strategy. The employed method of acquisition affords accurate mass information on both the precursor and associated product ions, whilst preserving and recording the intensities of the ions. The latter facilitates label-free quantification. The experimental ion density observations obtained for the rabbit sub proteome were found to share great similarity with five other mammalian samples, including human heart, human breast tissue, human plasma, rat liver and a mouse cell line. Redundant, species-homologues peptide identifications from other mammalian organisms were used for initial protein identification, which were complemented with peptide identifications of translated gene sequences. The feasibility and accuracy of label-free quantification of the identified peptides and proteins utilizing above mentioned strategy is demonstrated for selected cardiac rabbit proteins.


Assuntos
Reperfusão Miocárdica , Miocárdio/química , Proteínas/análise , Proteoma , Sequência de Aminoácidos , Animais , Cromatografia Líquida , Humanos , Masculino , Espectrometria de Massas , Dados de Sequência Molecular , Proteínas/química , Coelhos , Reprodutibilidade dos Testes
19.
J Proteome Res ; 5(1): 54-63, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16396495

RESUMO

A new approach for qualitative and quantitative proteomic analysis using capillary liquid chromatography and mass spectrometry to study the protein expression response in mycobacteria following isoniazid treatment is discussed. In keeping with known effects on the fatty acid synthase II pathway, proteins encoded by the kas operon (AcpM, KasA, KasB, Accd6) were significantly overexpressed, as were those involved in iron metabolism and cell division suggesting a complex interplay of metabolic events leading to cell death.


Assuntos
Antituberculosos/farmacologia , Isoniazida/farmacologia , Mycobacterium bovis/efeitos dos fármacos , Mycobacterium bovis/metabolismo , Proteoma/análise , Proteômica/métodos , Proteínas de Bactérias/análise , Parede Celular/metabolismo , Cromatografia Líquida , Metabolismo dos Lipídeos , Espectrometria de Massas , Proteoma/efeitos dos fármacos
20.
Mol Cell Proteomics ; 5(1): 144-56, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16219938

RESUMO

Relative quantification methods have dominated the quantitative proteomics field. There is a need, however, to conduct absolute quantification studies to accurately model and understand the complex molecular biology that results in proteome variability among biological samples. A new method of absolute quantification of proteins is described. This method is based on the discovery of an unexpected relationship between MS signal response and protein concentration: the average MS signal response for the three most intense tryptic peptides per mole of protein is constant within a coefficient of variation of less than +/-10%. Given an internal standard, this relationship is used to calculate a universal signal response factor. The universal signal response factor (counts/mol) was shown to be the same for all proteins tested in this study. A controlled set of six exogenous proteins of varying concentrations was studied in the absence and presence of human serum. The absolute quantity of the standard proteins was determined with a relative error of less than +/-15%. The average MS signal responses of the three most intense peptides from each protein were plotted against their calculated protein concentrations, and this plot resulted in a linear relationship with an R(2) value of 0.9939. The analyses were applied to determine the absolute concentration of 11 common serum proteins, and these concentrations were then compared with known values available in the literature. Additionally within an unfractionated Escherichia coli lysate, a subset of identified proteins known to exist as functional complexes was studied. The calculated absolute quantities were used to accurately determine their stoichiometry.


Assuntos
Proteínas Sanguíneas/análise , Proteínas de Escherichia coli/análise , Proteômica , Humanos , Fragmentos de Peptídeos/análise , Padrões de Referência , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Tripsina/metabolismo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa