Catheter Cardiovasc Interv ; 88(1): 51-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26331782

RESUMO

BACKGROUND: Scoring balloons produce excellent acute results in the treatment of in-stent restenosis (ISR), fibro-calcific and bifurcation lesions but have not been shown to affect the restenosis rate. A novel paclitaxel-coated scoring balloon (SB) was developed and tested to overcome this limitation. METHODS AND RESULTS: SB were coated with paclitaxel admixed with a specific excipient. Patients at four clinical sites in Germany and one in Brazil with ISR of coronary bare metal stent (BMS) were randomized 1:1 to treatment with either a drug-coated or uncoated SB. Baseline and 6-month follow-up quantitative coronary angiography was performed by an independent blinded core lab and all patients will be evaluated clinically for up to one year. The primary endpoint was angiographic in-segment late lumen loss (LLL). Secondary endpoints included the rate of clinically driven target lesion revascularization (TLR), composite of major adverse cardiovascular events (MACE), stent thrombosis and other variables. Sixty-one patients were randomized (28 uncoated and 33 drug-coated SB); mean age 65 years, males 72%, and presence of diabetes 39%. At 6-month angiography, in-segment LLL was 0.48 ± 0.51 mm in the uncoated SB group versus 0.17 ± 0.40 mm in the drug-coated SB group (P = 0.01; ITT analysis). The rate of binary restenosis was 41% in the uncoated SB group versus 7% in the drug-coated SB group (P = 0.004). The MACE rate was 32% with the uncoated SB vs. 6% in the drug-coated SB group (P = 0.016). This difference was primarily due to the reduced need for clinically driven TLR in the coated SB group (3% vs. 32% P = 0.004). CONCLUSIONS: A novel paclitaxel-coated coronary SB has been developed and successfully used in a first-in-human randomized controlled trial [ClinicalTrials.gov Identifier: NCT01495533]. © 2015 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Brasil , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Alemanha , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Retratamento , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 84(7): 1089-98, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24259380

RESUMO

OBJECTIVE: Scoring balloons are particularly useful in the acute treatment of fibro-calcific, bifurcation and in-stent restenosis lesions but have not been shown to affect the restenosis rate. Conventional balloons coated with paclitaxel have recently been shown to reduce restenosis rates in certain lesion subsets, but are associated with suboptimal acute results. A novel paclitaxel-coated scoring balloon was developed to overcome these limitations. DESIGN: AngioSculpt(®) scoring balloons (SB) were coated with paclitaxel admixed with a specific excipient. SETTING AND INTERVENTIONS: Four in vitro and in vivo studies were performed: (a) loss of the drug during passage to the lesion, (b) transfer of the drug to the vessel wall; (c) inhibition of neo-intimal proliferation in porcine coronary arteries as compared to uncoated SB and the Paccocath™, and (d) evaluation of the dose-response to 1.5-12 µg of paclitaxel/mm(2) . MAIN OUTCOME MEASURES AND RESULTS: Drug loss during delivery to the lesion was 17% ± 8%, and transfer to the vessel wall was 9% ± 4% of dose on unused balloons. The paclitaxel-coated SB resulted in a lower late lumen loss of 0.27 ± 0.24 mm compared to 1.4 ± 0.7 mm with the uncoated SB (P = 0.001). Histomorphometry revealed larger luminal areas of 6.8 ± 1.6 mm(2) (paclitaxel-coated SB) and 5.8 ± 1.7 mm(2) (Paccocath) as compared to the uncoated SB (2.3 ± 1.5 mm(2) ; P = 0.001). No coating related adverse effects were observed on follow-up angiography or histologic examination at the treatment site or downstream myocardium. CONCLUSION: A novel paclitaxel-coated SB leads to a significant inhibition of neointimal proliferation in the porcine coronary model.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Materiais Revestidos Biocompatíveis , Estenose Coronária/cirurgia , Vasos Coronários/patologia , Paclitaxel/farmacologia , Túnica Íntima/patologia , Animais , Antineoplásicos Fitogênicos/farmacologia , Estenose Coronária/patologia , Modelos Animais de Doenças , Desenho de Equipamento , Hiperplasia/prevenção & controle , Masculino , Suínos , Túnica Íntima/efeitos dos fármacos
3.
Catheter Cardiovasc Interv ; 82(3): 352-9, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22927100

RESUMO

BACKGROUND: The provisional approach for bifurcation stenting with side-branch balloon angioplasty is associated with dissections and suboptimal results requiring kissing balloon techniques or bailout stenting. We hypothesized that using a scoring balloon for the side branch and a drug-eluting stent for the main vessel might improve outcomes of true bifurcation lesions. METHODS AND RESULTS: A total of 93 patients with complex bifurcations were enrolled in a multicenter, single-arm, prospective clinical trial. A drug-eluting stent was deployed in the main vessel following dilatation of the side-branch stenosis with a scoring balloon. The overall angiographic success rate was 93.5%, and procedural success rate was 91.4%. The final diameter stenosis was 13.9% ± 7.2% for the main vessel and 33.3% ± 22.9% for the side branch. Crossover to stent deployment in the side branch was required in 10.8%. The postscoring balloon dissection rate was 8.2% and 6% (all ≤ class C) for the main vessel and side branch respectively, which was reduced to 1.1 and 2.1% poststenting. At 9-month follow-up, the composite MACE rate [cardiac death, myocardial infarction, or target lesion revascularization (TLR)] was 5.4%, including a TLR rate of 3.3% (1.1% from hospital discharge to 9 months). CONCLUSION: The 9-month results of the AGILITY trial support a simple provisional strategy for treating complex true bifurcation lesions with deployment of a drug-eluting stent in the main vessel after dilatation of the side-branch vessel with a scoring balloon. This strategy was associated with excellent and safe procedural results, a low rate of crossover to side-branch stenting, and favorable outcomes.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Estenose Coronária/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/mortalidade , Trombose Coronária/etiologia , Stents Farmacológicos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
4.
Catheter Cardiovasc Interv ; 70(7): 1034-9, 2007 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-18044759

RESUMO

OBJECTIVE: To evaluate the AngioSculpt (ASC), a novel scoring balloon catheter designed to treat complex diffuse fibro-calcific atherosclerotic lesions and avoid device slippage during deployment, in patients with infra-popliteal disease. METHODS: The ASC incorporates a flexible nitinol scoring element containing three or more spiral struts which encircle a minimally compliant balloon to create focal concentration of the dilating force. Patients scheduled for percutaneous intervention of infra-popliteal arteries or planned amputation and with a reference vessel diameter of 1.5-3.5 mm were included in the study. RESULTS: A total of 42 patients and 56 lesions were treated at five sites. Of these, 38 patients (90.5%) presented with critical limb ischemia (Rutherford Class > or = 4). The ASC was successfully deployed in 98.2% (55/56) of lesions attempted and was used as primary therapy without stenting in 89.3% (50/56). Lesion morphology was complex, including moderate/severe calcification in 73%, lesion length 33.9 +/- 42.2 mm, bifurcation in 26.8%, and ostial in 12.5%. There was no significant device slippage and no perforations. Post-ASC dissections occurred in only six (10.7%) lesions and were minor or resolved with stenting. In 13 patients initially referred for amputation, ASC treatment resulted in limb salvage. CONCLUSIONS: The ASC is highly effective in a broad range of complex lesion morphologies, in most cases as stand-alone therapy, is associated with a very low complication rate and avoids device slippage during deployment. Additional studies are planned to assess the long term efficacy of this promising new technology.


Assuntos
Angioplastia com Balão/instrumentação , Isquemia/etiologia , Doenças Vasculares Periféricas/terapia , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Ligas , Estado Terminal , Desenho de Equipamento , Europa (Continente) , Feminino , Humanos , Isquemia/patologia , Isquemia/terapia , Salvamento de Membro , Masculino , Doenças Vasculares Periféricas/complicações , Doenças Vasculares Periféricas/patologia , Artéria Poplítea/patologia , Estudos Prospectivos , Sistema de Registros , Projetos de Pesquisa , Índice de Gravidade de Doença , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 88(1): 51-59, 2016. ilus, tab, graf
Artigo em Inglês | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1061852

RESUMO

Scoring balloons produce excellent acute results in the treatment of instentrestenosis (ISR), fibro-calcific and bifurcation lesions but have not been shown toaffect the restenosis rate. A novel paclitaxel-coated scoring balloon (SB) was developedand tested to overcome this limitation. Methods and Results: SB were coatedwith paclitaxel admixed with a specific excipient. Patients at four clinical sites inGermany and one in Brazil with ISR of coronary bare metal stent (BMS) were randomized1:1 to treatment with either a drug-coated or uncoated SB. Baseline and 6-monthfollow-up quantitative coronary angiography was performed by an independent blindedcore lab and all patients will be evaluated clinically for up to one year. The primaryendpoint was angiographic in-segment late lumen loss (LLL). Secondary endpoints included the rate of clinically driven target lesion revascularization (TLR), composite ofmajor adverse cardiovascular events (MACE), stent thrombosis and other variables.Sixty-one patients were randomized (28 uncoated and 33 drug-coated SB); mean age65 years, males 72%, and presence of diabetes 39%. At 6-month angiography, insegmentLLL was 0.48 6 0.51 mm in the uncoated SB group versus 0.17 6 0.40 mm inthe drug-coated SB group (P 5 0.01; ITT analysis). The rate of binary restenosis was41% in the uncoated SB group versus 7% in the drug-coated SB group (P 5 0.004). TheMACE rate was 32% with the uncoated SB vs. 6% in the drug-coated SB group(P 5 0.016). This difference was primarily due to the reduced need for clinically drivenTLR in the coated SB group (3% vs. 32% P 5 0.004). Conclusions: A novel paclitaxelcoatedcoronary SB has been developed and successfully used in a first-in-human randomized controlled trial...