RESUMO
BACKGROUND: Coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) received an Emergency Use Authorization by the US Food and Drug Administration (FDA). CCP with a signal-to-cutoff ratio ofâ ≥12 using the Ortho VITROS severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoglobulin G (IgG) test (OVSARS2IgG) is permitted to be labeled "high titer." Little is known about the relationship between OVSARS2IgG ratio and neutralizing capacity of plasma/sera against genuine SARS-CoV-2. METHODS: Nine hundred eighty-one samples from 196 repeat CCP donors 0-119 days post-initial donation (DPID) were analyzed. Neutralizing capacity was assessed for 50% (PRNT50) and 90% (PRNT90) reduction of infectious virus using the gold standard plaque reduction neutralization test (PRNT). A subset of 91 donations was evaluated by OVSARS2IgG and compared to PRNT titers for diagnostic accuracy. RESULTS: Of donations, 32.7%/79.5% (PRNT90/PRNT50) met a 1:80 titer initially but only 14.0%/48.8% (PRNT90/PRNT50) met this cutoffâ ≥85 DPID. Correlation of OVSARS2IgG results to neutralizing capacity allowed extrapolation to CCP therapy results. CCP with OVSARS2IgG ratios equivalent to a therapeutically beneficial group had neutralizing titers ofâ ≥1:640 (PRNT50) and/orâ ≥1:80 (PRNT90). Specificity and positive predictive value of the OVSARS2IgG for qualifying highly neutralizing CCP was optimal using ratios significantly greater than the FDA cutoff. CONCLUSIONS: This information provides a basis for refining the recommended properties of CCP used to treat COVID-19.
Assuntos
COVID-19/imunologia , COVID-19/terapia , SARS-CoV-2/imunologia , Estudos de Coortes , Feminino , Humanos , Imunização Passiva/normas , Masculino , Pessoa de Meia-Idade , Testes de Neutralização , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo , Soroterapia para COVID-19RESUMO
Mycobacterium tuberculosis (Mtb), the etiologic agent of tuberculosis, must adapt to host-associated environments during infection by modulating gene expression. Small regulatory RNAs (sRNAs) are key regulators of bacterial gene expression, but their roles in Mtb are not well understood. Here, we address the expression and function of the Mtb sRNA Mcr11, which is associated with slow bacterial growth and chronic infections in mice. We found that stable expression of Mcr11 requires multiple factors specific to TB-complex bacteria, including the AbmR transcription factor. Bioinformatic analyses used to predict regulatory targets of Mcr11 identified 7-11 nucleotide regions with potential for direct base-pairing with Mcr11 immediately upstream of Rv3282, fadA3, and lipB. mcr11-dependent regulation of these genes was demonstrated using qRT-PCR and found to be responsive to the presence of fatty acids. Mutation of the putative Mcr11 base-pairing site upstream of lipB in a promoter reporter strain resulted in significant de-repression of lipB expression, similar to that observed in mcr11-deleted Mtb. These studies establish Mcr11's roles in regulating growth and central metabolism in Mtb. Our finding that multiple TB-complex-specific factors are required for production of stable Mcr11 also emphasizes the need to better understand mechanisms of sRNA expression and stability in TB.
Assuntos
Regulação Bacteriana da Expressão Gênica/fisiologia , Mycobacterium tuberculosis , Pequeno RNA não Traduzido/metabolismo , Fatores de Transcrição/metabolismo , Animais , Proteínas de Bactérias/metabolismo , Biologia Computacional , Genes Bacterianos , Lipoilação/genética , Camundongos , Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/metabolismo , RNA Bacteriano/genética , RNA Bacteriano/metabolismo , Pequeno RNA não Traduzido/genética , Reação em Cadeia da Polimerase em Tempo RealRESUMO
BACKGROUND: Convalescent plasma products are a potential passive immunotherapy for Coronavirus disease 2019 (COVID-19) disease. Various approaches have been utilized to determine the concentration of Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)-neutralizing antibodies in plasma products. The Canadian Blood Services used Plaque Reduction Neutralization Test 50 (PRNT50) -generated values to qualify convalescent plasma donations supporting clinical trials in Canada. This manuscript describes changes in PRNT50 titers of repeat male plasma donations collected approximately 1-4 months after onset of COVID-19 signs and symptoms in donors. STUDY DESIGN AND METHODS: Men were eligible to donate if they: met standard criteria, were < 67 years of age, reported a previous SARS-CoV-2-positive nucleic acid test, and recovered and were symptom free for at least 28 days prior to donation. Repeat donation analysis required at least one original and one repeat donation where a PRNT50 was performed. RESULTS: From April 29, 2020 to July 25, 2020, 156 donors donated once, with 78 (50%) of the donated plasma having PRNT50 titers of ≥1:160. Thirty-seven (23.7%) of the donated plasma had a titer of 1:40 or 1:80 (individuals donating this plasma were asked to donate a second time only). A total of 30 donors (19.2%) had repeat donations. Of the repeat donors, 15 (50%) had at least an eightfold change from peak to trough PRNT50 titers within greater than 90 days after onset of COVID-19 symptoms. CONCLUSIONS: Blood operators cannot infer that SARS-CoV-2 PRNT50 will remain high in repeat plasma donors 3-4 months after onset of COVID-19 symptoms.
Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Doadores de Sangue , COVID-19/sangue , COVID-19/terapia , Convalescença , SARS-CoV-2/metabolismo , Adulto , Canadá , Humanos , Imunização Passiva , Masculino , Pessoa de Meia-Idade , Soroterapia para COVID-19RESUMO
Gene regulatory networks used by Mycobacterium tuberculosis (Mtb) during infection include many genes of unknown function, confounding efforts to determine their roles in Mtb biology. Rv1265 encodes a conserved hypothetical protein that is expressed during infection and in response to elevated levels of cyclic AMP. Here, we report that Rv1265 is a novel auto-inhibitory ATP-binding transcription factor that upregulates expression of the small non-coding RNA Mcr11, and propose that Rv1265 be named ATP-binding mcr11 regulator (AbmR). AbmR directly and specifically bound DNA, as determined by electrophoretic mobility shift assays, and this DNA-binding activity was enhanced by AbmR's interaction with ATP. Genetic knockout of abmR in Mtb increased abmR promoter activity and eliminated growth phase-dependent increases in mcr11 expression during hypoxia. Mutagenesis identified arginine residues in the carboxy terminus that are critical for AbmR's DNA-binding activity and gene regulatory function. Limited similarity to other DNA- or ATP-binding domains suggests that AbmR belongs to a novel class of DNA- and ATP-binding proteins. AbmR was also found to form large organized structures in solution and facilitate the serum-dependent association of Mtb with human lung epithelial cells. These results indicate a potentially complex role for AbmR in Mtb biology.
Assuntos
Proteínas de Bactérias/metabolismo , Proteínas de Transporte/metabolismo , Mycobacterium tuberculosis/genética , Pequeno RNA não Traduzido/genética , Fatores de Transcrição/metabolismo , Aderência Bacteriana/genética , Regulação Bacteriana da Expressão Gênica , Redes Reguladoras de Genes , Genes Reguladores , Regiões Promotoras Genéticas , Ligação ProteicaRESUMO
Background: In the earliest days of COVID-19 pandemic, the collection of dried blood spots (DBS) enabled public health laboratories to undertake population-scale seroprevalence studies to estimate rates of SARS-CoV-2 exposure. With SARS-CoV-2 seropositivity levels now estimated to exceed 94% in the United States, attention has turned to using DBS to assess functional (neutralizing) antibodies within cohorts of interest. Methods: Contrived DBS eluates from convalescent, fully vaccinated and pre-COVID-19 serum samples were evaluated in SARS-CoV-2 plaque reduction neutralization titer (PRNT) assays, a SARS-CoV-2 specific 8-plex microsphere immunoassay, a cell-based pseudovirus assay, and two different spike-ACE2 inhibition assays, an in-house Luminex-based RBD-ACE2 inhibition assay and a commercial real-time PCR-based inhibition assay (NAB-Sure™). Results: DBS eluates from convalescent individuals were compatible with the spike-ACE2 inhibition assays, but not cell-based pseudovirus assays or PRNT. However, the insensitivity of cell-based pseudovirus assays was overcome with DBS eluates from vaccinated individuals with high SARS-CoV-2 antibody titers. Conclusion: SARS-CoV-2 neutralizing titers can be derived with confidence from DBS eluates, thereby opening the door to the use of these biospecimens for the analysis of vulnerable populations and normally hard to reach communities.
RESUMO
Anti-COVID antibody therapeutics have been developed but not widely used due to their high cost and escape of neutralization from the emerging variants. Here, we describe the development of VHH-IgA1.1, a nanobody IgA fusion molecule as an inhalable, affordable and less invasive prophylactic and therapeutic treatment against SARS-CoV-2 Omicron variants. VHH-IgA1.1 recognizes a conserved epitope of SARS-CoV-2 spike protein Receptor Binding Domain (RBD) and potently neutralizes major global SARS-CoV-2 variants of concern (VOC) including the Omicron variant and its sub lineages BA.1.1, BA.2 and BA.2.12.1. VHH-IgA1.1 is also much more potent against Omicron variants as compared to an IgG Fc fusion construct, demonstrating the importance of IgA mediated mucosal protection for Omicron infection. Intranasal administration of VHH-IgA1.1 prior to or after challenge conferred significant protection from severe respiratory disease in K18-ACE2 transgenic mice infected with SARS-CoV-2 VOC. More importantly, for cost-effective production, VHH-IgA1.1 produced in Pichia pastoris had comparable potency to mammalian produced antibodies. Our study demonstrates that intranasal administration of affordably produced VHH-IgA fusion protein provides effective mucosal immunity against infection of SARS-CoV-2 including emerging variants.
Assuntos
COVID-19 , Imunoglobulina A , SARS-CoV-2 , Anticorpos de Domínio Único , Enzima de Conversão de Angiotensina 2 , Animais , Anticorpos Antivirais/farmacologia , Epitopos/química , Humanos , Imunoglobulina A/farmacologia , Imunoglobulina G , Camundongos , Anticorpos de Domínio Único/farmacologia , Glicoproteína da Espícula de CoronavírusRESUMO
Background: In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies." SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. Methods: To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. SARS-CoV-2 serology standard reference material and First WHO International Standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. Results: SeroNet institutions reported development of a total of 27 ELISA methods, 13 multiplex assays, 9 neutralization assays, and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. Conclusions: SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 virus and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons.
RESUMO
BACKGROUND: Serological assays designed to detect SARS-CoV-2 antibodies are being used in serological surveys and other specialized applications. As a result, and to ensure that the outcomes of serological testing meet high quality standards, evaluations are required to assess the performance of these assays and the proficiency of laboratories performing them. METHODS: A panel of 60 plasma/serum samples from blood donors who had reverse transcriptase-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 infections and 21 SARS-CoV-2 negative samples were secured and distributed to interested laboratories within Canada (n = 30) and the United States (n = 1). Participating laboratories were asked to provide details on the diagnostic assays used, the platforms the assays were performed on, and the results obtained for each panel sample. Laboratories were blinded with respect to the expected outcomes. RESULTS: The performance of the different assays evaluated was excellent, with the high-throughput platforms of Roche, Ortho, and Siemens demonstrating 100% sensitivity. Most other high-throughput platforms had sensitivities of >93%, with the exception of the IgG assay using the Abbott ARCHITECT which had an average sensitivity of only 87%. The majority of the high-throughput platforms also demonstrated very good specificities (>97%). CONCLUSION: This proficiency study demonstrates that most of the SARS-CoV-2 serological assays utilized by provincial public health or hospital laboratories in Canada have acceptable sensitivity and excellent specificity.
HISTORIQUE: Les dosages sérologiques conçus pour dépister les anticorps anti-SRAS-CoV-2 sont utilisés dans les études sérologiques et d'autres applications spécialisées. Par conséquent, et pour s'assurer que leurs résultats respectent des normes de qualité, il faut procéder à des évaluations de leur performance et de la compétence des laboratoires à les effectuer. MÉTHODOLOGIE: Les chercheurs ont obtenu une batterie de 60 prélèvements de plasma et de sérum chez des donneurs dont l'amplification en chaîne par polymérase après transcription inverse (RT-PCR) avait confirmé des infections par le SRAS-CoV-2 et de 21 prélèvements dont les résultats étaient négatifs au SRAS-CoV-2 et les ont distribués aux laboratoires intéressés du Canada (n = 30) et des États-Unis (n = 1). Ils ont invité les laboratoires participants à fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages étaient exécutés et les résultats obtenus pour chaque échantillon. Les chercheurs ont demandé aux laboratoires participants de fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages ont été effectués, et les résultats obtenus à l'égard de chaque échantillon. Les laboratoires ont mené les études à l'insu des résultats escomptés. RÉSULTATS: Les divers dosages avaient une excellente exécution, les plateformes à haut débit de Roche, d'Ortho et de Siemens démontrant une sensibilité de 100 %. La plupart des autres plateformes à haut débit avaient des sensibilités de plus de 93 %, à l'exception des dosages des IgG faisant appel à l'analyseur ARCHITECT d'Abbott, dont la sensibilité moyenne était de seulement 87 %. La majorité des plateformes à haut débit avaient également une très bonne spécificité (plus de 97 %). CONCLUSION: La présente étude de compétence démontre que la plupart des dosages sérologiques du SRAS-CoV-2 évalués dans des laboratoires sanitaires provinciaux ou les laboratoires hospitaliers du Canada possèdent une sensibilité acceptable et une excellente spécificité.
RESUMO
In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies" (https://www.cancer.gov/research/key-initiatives/covid-19/coronavirus-research-initiatives/serological-sciences-network). SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology standard reference material and first WHO international standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. SeroNet institutions reported development of a total of 27 enzyme-linked immunosorbent assay (ELISA) methods, 13 multiplex assays, and 9 neutralization assays and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. In conclusion, SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons. IMPORTANCE SeroNet institutions have developed or implemented 61 diverse COVID-19 serological assays and are collaboratively working to harmonize these assays using reference materials to establish standardized reporting units. This will facilitate clinical interpretation of serology results and cross-comparison of research data.
Assuntos
COVID-19 , Anticorpos Antivirais , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , SARS-CoV-2 , Testes Sorológicos/métodosRESUMO
The evaluation of humoral protective immunity against SARS-CoV-2 remains crucial in understanding both natural immunity and protective immunity conferred by the several vaccines implemented in the fight against COVID-19. The reference standard for the quantification of antibodies capable of neutralizing SARS-CoV-2 is the plaque-reduction neutralization test (PRNT). However, given that it is a laboratory-developed assay, validation is crucial in order to ensure sufficient specificity and intra- and interassay precision. In addition, a multitude of other serological assays have been developed, including enzyme-linked immunosorbent assay (ELISA), flow cytometry-based assays, luciferase-based lentiviral pseudotype assays, and commercially available human ACE2 receptor-blocking antibody tests, which offer practical advantages in the evaluation of the protective humoral response against SARS-CoV-2. In this study, we validated a SARS-CoV-2 PRNT to assess both 50% and 90% neutralization of SARS-CoV-2 according to guidelines outlined by the World Health Organization. Upon validation, the reference-standard PRNT demonstrated excellent specificity and both intra- and interassay precision. Using the validated assay as a reference standard, we characterized the neutralizing antibody response in specimens from patients with laboratory-confirmed COVID-19. Finally, we conducted a small-scale multilaboratory comparison of alternate SARS-CoV-2 PRNTs and surrogate neutralization tests. These assays demonstrated substantial to perfect interrater agreement with the reference-standard PRNT and offer useful alternatives to assess humoral immunity against SARS-CoV-2. IMPORTANCE SARS-CoV-2, the causal agent of COVID-19, has infected over 246 million people and led to over 5 million deaths as of October 2021. With the approval of several efficacious COVID-19 vaccines, methods to evaluate protective immune responses will be crucial for the understanding of long-term immunity in the rapidly growing vaccinated population. The PRNT, which quantifies SARS-CoV-2-neutralizing antibodies, is used widely as a reference standard to validate new platforms but has not undergone substantial validation to ensure excellent inter- and intraassay precision and specificity. Our work is significant, as it describes the thorough validation of a PRNT, which we then used as a reference standard for the comparison of several alternative serological methods to measure SARS-CoV-2-neutralizing antibodies. These assays demonstrated excellent agreement with the reference-standard PRNT and include high-throughput platforms, which can greatly enhance capacity to assess both natural and vaccine-induced protective immunity against SARS-CoV-2.
Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Imunidade Humoral/imunologia , Testes de Neutralização/métodos , SARS-CoV-2/imunologia , Enzima de Conversão de Angiotensina 2 , Animais , Anticorpos Neutralizantes , Anticorpos Antivirais/imunologia , Vacinas contra COVID-19/imunologia , Chlorocebus aethiops , Testes Diagnósticos de Rotina , Ensaio de Imunoadsorção Enzimática/métodos , Células HEK293 , Humanos , Imunidade , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Células VeroRESUMO
Most of the patients infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) mount a humoral immune response to the virus within a few weeks of infection, but the duration of this response and how it correlates with clinical outcomes has not been completely characterized. Of particular importance is the identification of immune correlates of infection that would support public health decision-making on treatment approaches, vaccination strategies, and convalescent plasma therapy. While ELISA-based assays to detect and quantitate antibodies to SARS-CoV-2 in patient samples have been developed, the detection of neutralizing antibodies typically requires more demanding cell-based viral assays. Here, we present a safe and efficient protein-based assay for the detection of serum and plasma antibodies that block the interaction of the SARS-CoV-2 spike protein receptor binding domain (RBD) with its receptor, angiotensin-converting enzyme 2 (ACE2). The assay serves as a surrogate neutralization assay and is performed on the same platform and in parallel with an ELISA for the detection of antibodies against the RBD, enabling a direct comparison. The results obtained with our assay correlate with those of 2 viral-based assays, a plaque reduction neutralization test (PRNT) that uses live SARS-CoV-2 virus and a spike pseudotyped viral vector-based assay.
Assuntos
Anticorpos Neutralizantes/imunologia , Infecções por Coronavirus/imunologia , Infecções por Coronavirus/terapia , Pneumonia Viral/imunologia , Pneumonia Viral/terapia , Glicoproteína da Espícula de Coronavírus/imunologia , Anticorpos Antivirais/sangue , Área Sob a Curva , COVID-19 , Ensaio de Imunoadsorção Enzimática , Humanos , Imunização Passiva/métodos , Testes de Neutralização , Pandemias , Análise de Regressão , Estudos de Amostragem , Resultado do Tratamento , Proteínas do Envelope Viral/imunologia , Soroterapia para COVID-19RESUMO
In-cell NMR spectroscopy was used to screen for drugs that disrupt the interaction between prokaryotic ubiquitin like protein, Pup, and mycobacterial proteasome ATPase, Mpa. This interaction is critical for Mycobacterium tuberculosis resistance against nitric oxide (NO) stress; interruption of this process was proposed as a mechanism to control latent infection. Three compounds isolated from the NCI Diversity set III library rescued the physiological proteasome substrate from degradation suggesting that the proteasome degradation pathway was selectively targeted. Two of the compounds bind to Mpa with sub-micromolar to nanomolar affinity, and all three exhibit potency toward mycobacteria comparable to antibiotics currently available on the market, inhibiting growth in the low micromolar range.