Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Circ J ; 76(2): 342-50, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22104034

RESUMO

BACKGROUND: Scattering centers (SC) are often observed with optical coherence tomography (OCT) in some struts of bioresorbable vascular scaffolds (BVS). These SC might be caused by crazes in the polymer during crimp-deployment (more frequent at inflection points) or by other processes, such as physiological loading or hydrolysis (eventually increasing with time). The spatial distribution and temporal evolution of SC in BVS might help to understand their meaning. METHODS AND RESULTS: Three patients were randomly selected from 12 imaged with Fourier-domain OCT at both baseline and 6 months in the ABSORB cohort B study (NCT00856856). Frame-by-frame analysis of the SC distribution was performed using spread-out vessel charts, and the results from baseline and 6 months were compared. A total of 4,328 struts were analyzed. At baseline and follow-up all SC appeared at inflection points. No significant difference was observed between baseline and 6 months in the number of SC struts (14.9 vs. 14.5%, P=0.754) or in the distribution of SC. The proportion and distribution of SC did not vary substantially among the patients analyzed. CONCLUSIONS: The SC observed in OCT imaging of the BVS are located exclusively at inflection points and do not increase with time. These findings strongly suggest that SC are caused by crazes in the polymer during crimp-deployment, ruling out any major role of hydrolysis or other time-dependent processes.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Poliésteres , Tomografia de Coerência Óptica/métodos , Técnicas de Imagem Cardíaca/métodos , Estudos de Coortes , Doença da Artéria Coronariana/diagnóstico , Everolimo , Seguimentos , Humanos , Hidrólise , Imunossupressores/uso terapêutico , Desenho de Prótese , Sistema de Registros , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico
2.
AJR Am J Roentgenol ; 191(6): 1767-75, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19020249

RESUMO

OBJECTIVE: The aim of this article is to present the sonographic appearance of the most common masses of the wrist and hand and to discuss the role of sonography in their diagnosis. CONCLUSION: Sonography is a readily available imaging technique that can detect and assess masses of the wrist and hand. Together with standard radiography, sonography can be used as a first-line radiologic technique in this field.


Assuntos
Mãos/diagnóstico por imagem , Neoplasias de Tecidos Moles/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem , Ultrassonografia/métodos , Traumatismos do Punho/diagnóstico por imagem , Punho/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
AJR Am J Roentgenol ; 191(5): W199-203, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18941055

RESUMO

OBJECTIVE: The objective of our study was to analyze the sonography examinations of nine consecutive patients with a history of distal radius fracture treated by open reduction and internal fixation of the volar plate who were referred by hand surgeons for sonography of the dorsal aspect of the wrist. CONCLUSION: We postulate that impingement of the extensor tendons in patients with distal radius fracture treated by volar plating starts with local hyperemia and is followed by tenosynovitis and, finally, by partial and complete tendon tears. Sonography is an effective, dynamic, and noninvasive technique with which to diagnose and evaluate damage to the extensor tendons and their synovial sheaths.


Assuntos
Parafusos Ósseos/efeitos adversos , Fixação Interna de Fraturas/efeitos adversos , Placa Palmar/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Traumatismos dos Tendões/etiologia , Traumatismos dos Tendões/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Palmar/diagnóstico por imagem , Fraturas do Rádio/complicações , Estudos Retrospectivos , Traumatismos dos Tendões/diagnóstico por imagem , Ultrassonografia
4.
Angew Chem Int Ed Engl ; 40(14): 2712-2715, 2001 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-29712329

RESUMO

A metal-free approach to the living ring-opening polymerization (ROP, shown schematically) of lactide has been developed using strongly basic amines such as 4-(dimethylamino)pyridine as transesterification catalysts. These organic catalysts must be used in combination with a nucleophile such as an alcohol, which is the actual initiating species.

5.
EuroIntervention ; 7(10): 1227-35, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22222916

RESUMO

AIMS: Optical coherence tomography (OCT) of a bioresorbable vascular scaffold (BVS) produces a highly reflective signal outlining struts. This signal interferes with the measurement of strut thickness, as the boundaries cannot be accurately identified, and with the assessment of coverage, because the neointimal backscattering convolutes that of the polymer, frequently making them indistinguishable from one another. We hypothesise that Gaussian line spread functions (LSFs) can facilitate identification of strut boundaries, improving the accuracy of strut thickness measurements and coverage assessment. METHODS AND RESULTS: Forty-eight randomly selected BVS struts from 12 patients in the ABSORB Cohort B clinical study and four Yucatan minipigs were analysed at baseline and follow-up (six months in humans, 28 days in pigs). Signal intensities from the raw OCT backscattering were fit to Gaussian LSFs for each interface, from which peak intensity and full-width-at-half-maximum (FWHM) were calculated. Neointimal coverage resulted in significantly different LSFs and higher FWHM values relative to uncovered struts at baseline (p<0.0001). Abluminal polymer-tissue interfaces were also significantly different between baseline and follow-up (p=0.0004 in humans, p<0.0001 in pigs). Using the location of the half-max of the LSF as the polymer-tissue boundary, the average strut thickness was 158±11 µm at baseline and 152±20 µm at six months (p=0.886), not significantly different from nominal strut thickness. CONCLUSIONS: Fitting the raw OCT backscattering signal to a Gaussian LSF facilitates identification of the interfaces between BVS polymer and lumen or tissue. Such analysis enables more precise measurement of the strut thickness and an objective assessment of coverage.


Assuntos
Implantes Absorvíveis , Vasos Coronários/patologia , Stents Farmacológicos , Alicerces Teciduais , Tomografia de Coerência Óptica/métodos , Implantes Absorvíveis/efeitos adversos , Animais , Estudos de Coortes , Estenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Seguimentos , Humanos , Modelos Animais , Neointima/diagnóstico , Neointima/etiologia , Neointima/patologia , Distribuição Normal , Estudos Retrospectivos , Suínos , Porco Miniatura , Alicerces Teciduais/efeitos adversos , Resultado do Tratamento
7.
J Am Chem Soc ; 125(10): 3046-56, 2003 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-12617671

RESUMO

A metal-free, organocatalytic approach to living polymerization using N-heterocyclic carbenes as nucleophilic catalysts generated and used in situ in a single-pot process is detailed. The N-heterocyclic carbene catalyst platform is extremely versatile, as the nature of the substituents has a pronounced effect of catalyst stability and activity toward different substrates. The generation of imidazolium- and thiazaolium-based carbenes was accomplished from the reaction of the corresponding salts with the appropriate bases. This allowed the rapid screening of libraries of catalysts that provided a basic understanding of catalyst structure (sterics, electronics, etc.) with the polymerization rate, control, substrate, and range of molecular weights. The imidazole-based catalysts were significantly more active toward ROP than the thiazolium-based analogues. No appreciable differences between imidazol-2-ylidene and imidazolin-2-ylidene catalysts were observed. Less sterically demanding carbenes were found to be more active toward ring-opening polymerization (ROP) than their sterically encumbered analogues for lactone polymerization. These data prompted the investigation of ionic liquid as a precatalyst reservoir in a phase-transfer polymerization with an immiscible THF solution of monomer and initiator. In situ activation of the ionic liquid generates carbene that migrates to the organic phase effecting living ROP. Precatalyst (ionic liquid) regeneration terminates polymerization. This simple reaction/recycle protocol readily allows repetitive ROPs from the ionic liquid using commercially available materials.

8.
Chemistry ; 8(15): 3308-19, 2002 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-12203311

RESUMO

The distinctive features of well-defined, three-dimensional macromolecules with topologies designed to enhance solubility and amplify end-group functionality facilitated nanophase morphologies in mixtures with organosilicates and ultimately nanoporous organosilicate networks. Novel macromolecular architectures including dendritic and star-shaped polymers and organic nanoparticles were prepared by a modular approach from several libraries of building blocks including various generations of dendritic initiators and dendrons, selectively placed to amplify functionality and/or arm number, coupled with living polymerization techniques. Mixtures of an organosilicate and the macromolecular template were deposited, cured, and the phase separation of the organic component, organized the vitrifying organosilicate into nanostructures. Removal of the sacrificial macromolecular template, also denoted as porogen, by thermolysis, yielded the desired nanoporous organosilicate, and the size scale of phase separation was strongly dependent on the chain topology. These materials were designed for use as interlayer, ultra-low dielectric insulators for on-chip applications with dielectric constant values as low as 1.5. The porogen design, chemistry and role of polymer architecture on hybrid and pore morphology will be emphasized.


Assuntos
Eletrônica/métodos , Desenho de Equipamento , Isomerismo , Miniaturização , Modelos Moleculares , Conformação Molecular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa