Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Am J Kidney Dis ; 75(4 Suppl 2): S1-S164, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32778223

RESUMO

The National Kidney Foundation's Kidney Disease Outcomes Quality Initiative (KDOQI) has provided evidence-based guidelines for hemodialysis vascular access since 1996. Since the last update in 2006, there has been a great accumulation of new evidence and sophistication in the guidelines process. The 2019 update to the KDOQI Clinical Practice Guideline for Vascular Access is a comprehensive document intended to assist multidisciplinary practitioners care for chronic kidney disease patients and their vascular access. New topics include the end-stage kidney disease "Life-Plan" and related concepts, guidance on vascular access choice, new targets for arteriovenous access (fistulas and grafts) and central venous catheters, management of specific complications, and renewed approaches to some older topics. Appraisal of the quality of the evidence was independently conducted by using a Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach, and interpretation and application followed the GRADE Evidence to Decision frameworks. As applicable, each guideline statement is accompanied by rationale/background information, a detailed justification, monitoring and evaluation guidance, implementation considerations, special discussions, and recommendations for future research.


Assuntos
Falência Renal Crônica/terapia , Nefrologia , Diálise Renal/normas , Sociedades Médicas , Dispositivos de Acesso Vascular/normas , Humanos
2.
Am J Kidney Dis ; 72(1): 10-18, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29602630

RESUMO

BACKGROUND: An arteriovenous fistula (AVF) is the recommended vascular access for hemodialysis (HD). Previous studies have not examined the resources and costs associated with creating and maintaining AVFs. STUDY DESIGN: Retrospective observational study. SETTING & PARTICIPANTS: Elderly US Medicare patients initiating hemodialysis therapy during 2010 to 2011. PREDICTOR: AVF primary and secondary patency and nonuse in the first year following AVF creation. OUTCOMES: Annualized vascular access costs per patient per year. RESULTS: Among patients with only a catheter at HD therapy initiation, only 54% of AVFs were successfully used for HD, 10% were used but experienced secondary patency loss within 1 year of creation, and 83% experienced primary patency loss within 1 year of creation. Mean vascular access costs per patient per year in the 2.5 years after AVF creation were $7,871 for AVFs that maintained primary patency in year 1, $13,282 for AVFs that experienced primary patency loss in year 1, $17,808 for AVFs that experienced secondary patency loss in year 1, and $31,630 for AVFs that were not used. Similar patterns were seen among patients with a mature AVF at HD therapy initiation and patients with a catheter and maturing AVF at HD therapy initiation. Overall, in 2013, fee-for-service Medicare paid $2.8 billion for dialysis vascular access-related services, ∼12% of all end-stage renal disease payments. LIMITATIONS: Lack of granularity with certain billing codes. CONCLUSIONS: AVF failure in the first year after creation is common and results in substantially higher health care costs. Compared with patients whose AVFs maintained primary patency, vascular access costs were 2 to 3 times higher for patients whose AVFs experienced primary or secondary patency loss and 4 times higher for patients who never used their AVFs. There is a need to improve AVF outcomes and reduce costs after AVF creation.


Assuntos
Derivação Arteriovenosa Cirúrgica/economia , Custos de Cuidados de Saúde , Falência Renal Crônica/economia , Falência Renal Crônica/terapia , Medicare/economia , Diálise Renal/economia , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/tendências , Estudos de Coortes , Feminino , Custos de Cuidados de Saúde/tendências , Humanos , Falência Renal Crônica/diagnóstico , Masculino , Medicare/tendências , Diálise Renal/tendências , Estudos Retrospectivos , Estados Unidos/epidemiologia
3.
Lancet ; 387(10032): 2026-34, 2016 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-27203778

RESUMO

BACKGROUND: For patients with end-stage renal disease who are not candidates for fistula, dialysis access grafts are the best option for chronic haemodialysis. However, polytetrafluoroethylene arteriovenous grafts are prone to thrombosis, infection, and intimal hyperplasia at the venous anastomosis. We developed and tested a bioengineered human acellular vessel as a potential solution to these limitations in dialysis access. METHODS: We did two single-arm phase 2 trials at six centres in the USA and Poland. We enrolled adults with end-stage renal disease. A novel bioengineered human acellular vessel was implanted into the arms of patients for haemodialysis access. Primary endpoints were safety (freedom from immune response or infection, aneurysm, or mechanical failure, and incidence of adverse events), and efficacy as assessed by primary, primary assisted, and secondary patencies at 6 months. All patients were followed up for at least 1 year, or had a censoring event. These trials are registered with ClinicalTrials.gov, NCT01744418 and NCT01840956. FINDINGS: Human acellular vessels were implanted into 60 patients. Mean follow-up was 16 months (SD 7·6). One vessel became infected during 82 patient-years of follow-up. The vessels had no dilatation and rarely had post-cannulation bleeding. At 6 months, 63% (95% CI 47-72) of patients had primary patency, 73% (57-81) had primary assisted patency, and 97% (85-98) had secondary patency, with most loss of primary patency because of thrombosis. At 12 months, 28% (17-40) had primary patency, 38% (26-51) had primary assisted patency, and 89% (74-93) had secondary patency. INTERPRETATION: Bioengineered human acellular vessels seem to provide safe and functional haemodialysis access, and warrant further study in randomised controlled trials. FUNDING: Humacyte and US National Institutes of Health.


Assuntos
Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Dispositivos de Acesso Vascular , Bioengenharia , Prótese Vascular , Células Cultivadas , Feminino , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Liso Vascular/citologia , Politetrafluoretileno/uso terapêutico , Desenho de Prótese
4.
J Vasc Surg ; 62(2): 434-41, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25953016

RESUMO

OBJECTIVE: More than 85% of patients with end-stage renal disease start dialysis through a tunneled dialysis catheter (TDC) for long periods while their arteriovenous fistula or vascular access graft (arteriovenous graft [AVG]) matures. Because TDCs are associated with a high risk of complications, including death and infection, use of an AVG that can be cannulated safely immediately after implantation may reduce morbidity in these patients by allowing earlier TDC removal. We report a prospective multicenter study of a new early-cannulation AVG (Gore ACUSEAL Vascular Graft; W. L. Gore & Associates, Flagstaff, Ariz). METHODS: Patients requiring creation of a prosthetic vascular access for hemodialysis were enrolled between July 2010 and February 2012 and observed for 12 months. Data were collected on the patients' baseline characteristics; location, position, loss of patency, and revisions of prior AVGs; dialysis sessions using the AVG; and major adverse events related to graft implantation or cannulation. Cumulative and primary unassisted graft patency rates were calculated. A subgroup analysis compared outcomes in patients in whom the AVG was first cannulated within 72 hours after implantation with outcomes in patients in whom the initial cannulation was performed >21 days postoperatively. RESULTS: The population of this study was formed by 138 patients who received an ACUSEAL graft. During follow-up, 17 patients died and the AVG was abandoned in 27. The median value for follow-up was 360 days for all patients (variance 15,387). The overall mean time to initial cannulation was 15 days, with 54 grafts (40%) first cannulated within 72 hours after graft implantation and 33 grafts first cannulated >21 days afterward. The reason for late cannulation in some patients was dependent on the implanting surgeon's decision and the surgeon's personal experience with early cannulating grafts. The 1-year overall cumulative patency rate was 79% (95% confidence interval, 71%-85%); the primary unassisted patency rate was 35% (95% confidence interval, 27%-44%). Adverse events included 6 hematomas (two of which were related to cannulation and occurred 107 and 169 days, respectively, after AVG implantation), 15 graft infections, and 15 cases of steal syndrome requiring intervention. Patients in the early- and later-cannulation groups had similar characteristics and no significant differences in rates of cumulative or primary unassisted patency or adverse events. CONCLUSIONS: This study demonstrated that the new, early-cannulation AVG graft can be cannulated soon after implantation without a significant difference in patency and complication rates compared with rates associated with standard cannulation of expanded polytetrafluoroethylene grafts in the literature. This new AVG may allow early removal or avoidance of TDC use in patients undergoing hemodialysis, potentially reducing or eliminating the number of days of catheter-dependent dialysis, but further studies will be needed to demonstrate this potential.


Assuntos
Derivação Arteriovenosa Cirúrgica , Prótese Vascular , Cateterismo , Falência Renal Crônica/terapia , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Adulto Jovem
5.
J Vasc Surg ; 61(1): 184-91, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25041989

RESUMO

OBJECTIVE: Our institutional quality-improvement (QI) initiative instituted a well-defined office follow-up schedule after arteriovenous fistula (AVF) creation, including an office visit within 30 days, fistulogram within 40 days, if indicated, and a second office visit within 55 days. In addition, a patient liaison contacted patients and dialysis units to improve follow-up. The purpose of this study was to determine the effect of the QI initiative on patient compliance and overall time to AVF permission to cannulate. METHODS: We performed a retrospective review of patients undergoing first-time radiocephalic, brachiocephalic, and basilic vein transposition creation before the QI initiative (pre-QI group: January to April 2012) and during the QI period (QI group: January to April 2013). Categoric data were compared using χ(2) analysis, and nominal data were compared using the Student t-test. RESULTS: We reviewed 198 first-time AVF creations in patients (57% male) with a mean age of 61 years. Demographics and comorbidities between the pre-QI and QI groups were similar. Compliance with the first 30-day postoperative appointment increased significantly after the QI initiative, from 48% in the pre-QI group to 65% in the QI group (P = .015). Yet, the QI initiative did not maintain an effect on the subsequent follow-up checkpoints. No statistical difference was identified for compliance with fistulogram within 40 days of access creation (pre-QI, 12% vs QI, 25%; P = .093) or for compliance with the 55-day postoperative appointment (pre-QI, 33% vs QI, 23%; P = .457). Both checkpoints demonstrated a very high noncompliance rate. Accordingly, the mean time to permission to cannulate was 88 days for both the pre-QI and QI groups, with a failure to mature rate of 22% for the pre-QI group and 21% for the QI group (P = .816). CONCLUSIONS: The QI initiative significantly increased the number of patients complying with the first 30-day follow-up appointment after AVF access creation. However, patient compliance with a timely fistulogram and the second follow-up appointment was poor and not influenced by the QI initiative, limiting the functional effect of the QI initiative on the time to AVF permission to cannulate.


Assuntos
Derivação Arteriovenosa Cirúrgica , Cateterismo , Diagnóstico por Imagem , Visita a Consultório Médico , Cooperação do Paciente , Diálise Renal , Extremidade Superior/irrigação sanguínea , Idoso , Cateterismo/normas , Distribuição de Qui-Quadrado , Comorbidade , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/normas , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Diálise Renal/normas , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento , Grau de Desobstrução Vascular
6.
J Vasc Surg ; 60(4): 1024-32, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24833247

RESUMO

BACKGROUND: Arteriovenous fistulas (AVFs) are recommended for hemodialysis access when possible. A noncannulatable but otherwise well functioning AVF leads to prolonged catheter dependency and frustration for the patient and the renal health care provider team. Difficult cannulation patients include obese individuals in whom cannulation sites are too deep, and others with vein segments that are short, tortuous, or otherwise difficult to palpate. The Venous Window Needle Guide for Salvage of AV Fistulae (SAVE) trial was designed to evaluate the efficacy and safety of the Venous Window Needle Guide (VWING; Vital Access Corp, Salt Lake City, Utah) device for salvage of such noncannulatable AVFs that are otherwise functional. METHODS: The SAVE study included patients with an established and otherwise mature AVF, in whom an additional procedure would otherwise be necessary to establish reliable cannulation. The VWING is a single-piece titanium device that allows repeated access of an AVF through a single puncture site (buttonhole technique). Inclusion criteria included mature AVFs 6.0 to 15.0 mm in depth with multiple failed attempts at cannulation or where the access could not be palpated. The devices were implanted subcutaneously and sutured to the anterior wall of the mature fistula. Study end points were reliable and successful cannulation and avoidance of adverse events during the 6-month follow-up, implant technical success, and clinical cannulation success. RESULTS: Enrollment included 54 patients at 11 trial sites with implantation of 82 VWING devices. Body mass index was 26 to 50 (median, 36), 40 (74%) patients were female, and age was 17 to 84 (median, 59) years. Forty (74%) individuals were diabetic. Thirty-three (61%) patients were white, 16 (30%) black, and 10 (18%) patients were Hispanic, Pacific Islander, or Native American. Three patients were excluded from data analysis for reasons unrelated to the device. Successful AVF access was achieved using the VWING in 49 (96%) of the 51 patients evaluated. The rate of device-related serious adverse events was 0.31 per patient-year; each event was resolved leaving the AVF functional. The rates of sepsis and study-related interventions were 0.04 and 0.65 per patient-year, respectively. There were no study-related deaths. One device was removed because of infection. The AVF survival rate at 6 months was 100%. The total number of study days was 9497 and the estimated number of device cannulations was 4238. CONCLUSIONS: The VWING was safe and effective in facilitating AVF cannulation for patients with an otherwise mature but noncannulatable fistula. Successful AVF access was achieved using the VWING in 49 (96%) of the 51 patients evaluated. The AVF survival rate at 6 months was 100%.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Cateterismo Periférico/instrumentação , Agulhas , Diálise Renal/instrumentação , Terapia de Salvação/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
7.
Semin Dial ; 27(3): 310-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24428351

RESUMO

Venous stenosis and occlusion are a major cause of vascular access dysfunction and failure. The HeRO Graft bypasses occlusion and traverses stenosis with outflow directly into the central venous circulation. A randomized, multicenter study was conducted to evaluate the efficacy and safety of the HeRO Graft relative to conventional AV grafts. The design was to enroll 143 patients in a 2:1 randomization ratio between HeRO and conventional AV control groups. Data on 72 subjects (52 HeRO Graft and 20 AV graft controls) were obtained. The HeRO Graft and control cohorts were comparable in baseline characteristics. Adequacy of dialysis, bacteremia rates, and adverse events were consistent between groups. Twelve month Kaplan-Meier estimates for primary and secondary patency rates were 34.8% and 67.6% in the HeRO Graft cohort, and 30.6% and 58.4% in the control cohort. There was no statistical difference in terms of patency between groups. The rates of intervention were 2.2/year for HeRO Graft and 1.6/year for the control (p = 0.100). Median days to loss of secondary patency was 238 for HeRO Graft versus 102 for the control (p = 0.032). The HeRO Graft appears to provide similar patency, adequacy of dialysis, and bacteremia rates to those of conventional AV grafts.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Prótese Vascular , Oclusão de Enxerto Vascular/cirurgia , Falência Renal Crônica/terapia , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular/fisiologia , Adulto , Idoso , Feminino , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Adulto Jovem
8.
J Vasc Surg ; 57(3): 776-83; discussion 782-3, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23313186

RESUMO

OBJECTIVE: The Hemodialysis Reliable Outflow (HeRO) graft is becoming a recognized alternative to lower extremity arteriovenous grafts (LEAVGs) as an option for patients who have exhausted traditional upper extremity access; however, which should be applied preferentially is unclear. METHODS: A retrospective review of LEAVG and HeRO implants from January 2004 to August 2010 was performed. Patient demographics, medical history, procedural data, and outcomes were evaluated. RESULTS: Within the time periods, 60 HeROs were placed in 59 patients and 22 LEAVGs were placed in 21 patients. Demographics were similar between the two groups for many factors; however, the patients who underwent HeRO placement had significantly higher body mass index compared with the LEAVG group. Mean follow-up was 13.9 months for the HeRO group and 11.9 months for the LEAVG group. The HeRO patients underwent a mean of 6.3 previous tunneled dialysis catheter insertions and 3.1 previous AVG/arteriovenous fistula placements. The LEAVG patients underwent placement of a mean of 4.1 previous tunneled dialysis catheters and 2.6 previous AVG/arteriovenous fistulas. The principal difference was the number of interventions to maintain patency, which was 2.21 per year in the HeRO group and 1.17 per year in the AVG group (P = .003) Secondary patency at 6 months was 77% for the HeRO patients and 83% for the LEAVG patients (P = .14). The HeRO and LEAVG groups had no difference in infection rate per 1000 days (0.61 vs 0.71; P = .77) or mortality rate (22% vs 19% respectively; P = .22) at 6 months. CONCLUSIONS: In access challenged patients, LEAVG and HeRO offer similar rates of secondary patency, infection, and all-cause mortality. The LEAVG required fewer interventions to maintain patency, and the HeRO maintains the benefit of utilizing the upper extremity site of venous drainage. In our practice, we prefer the HeRO to LEAVG, especially in patients with peripheral arterial disease and in the obese population, because it preserves lower extremity access options.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Extremidade Inferior/irrigação sanguínea , Diálise Renal , Insuficiência Renal/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/mortalidade , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Criança , Pré-Escolar , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Seleção de Pacientes , Doença Arterial Periférica/complicações , Desenho de Prótese , Infecções Relacionadas à Prótese/etiologia , Diálise Renal/efeitos adversos , Diálise Renal/mortalidade , Insuficiência Renal/complicações , Insuficiência Renal/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Virginia , Adulto Jovem
9.
Ann Vasc Surg ; 24(1): 114.e13-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19748220

RESUMO

BACKGROUND: Infection of a renal artery stent and pseudoaneurysm is extremely uncommon, with four reports in the literature. We present a fifth case and the complex management resulting in kidney salvage. METHODS AND RESULTS: A 56-year-old female underwent right renal artery stenting for hypertension. Postoperatively, she developed methicillin-resistant Staphylococcus infection, treated with antibiotics. Eight-month follow-up duplex ultrasound revealed a right renal artery pseudoaneurysm just distal to the stent. Computed tomography angiography (CTA) showed 2.8 cm proximal and 4.2 cm distal mycotic aneurysms. Antibiotics and planning angiogram were prescribed. A Chevron incision and duodenal kocherization were employed. The aorta below the superior mesenteric artery and below the renal vein was mobilized, as were the right renal artery and vein, hepatic artery, and saphenous vein. Following heparinization, the aorta was cross-clamped, as was the right renal artery at the hilum. The kidney was infused with cold saline. The renal artery stent was explanted, and aneurysmectomy was performed. The renal artery ostium was oversewn. A renal artery to hepatic artery saphenous vein bypass was fashioned, and patency was confirmed with intraoperative duplex ultrasound. Postoperatively, creatinine was normal, renal scan showed the right kidney to be functional, and duplex ultrasound showed a patent bypass graft. The patient was discharged on postoperative day 11 on long-term antibiotics. Eight-month follow-up duplex and CTA showed a patent bypass and durable repair. CONCLUSION: Renal artery stent infection with pseudoaneurysm is rare and can be diagnosed with duplex ultrasound. Renal salvage can be obtained but requires stent removal and autologous bypass grafting.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma Infectado/cirurgia , Remoção de Dispositivo , Hipertensão Renovascular/terapia , Infecções Relacionadas à Prótese/cirurgia , Artéria Renal/cirurgia , Veia Safena/transplante , Stents/efeitos adversos , Falso Aneurisma/diagnóstico , Falso Aneurisma/etiologia , Falso Aneurisma/microbiologia , Aneurisma Infectado/diagnóstico , Aneurisma Infectado/etiologia , Aneurisma Infectado/microbiologia , Antibacterianos/uso terapêutico , Desbridamento , Feminino , Artéria Hepática/cirurgia , Humanos , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/microbiologia , Artéria Renal/diagnóstico por imagem , Artéria Renal/microbiologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler Dupla
10.
J Vasc Surg ; 49(4): 851-7; discussion 857-8, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19341879

RESUMO

OBJECTIVE: This phase I IDE study (STAPLE-1) evaluated the primary endpoints of safety (major device-related adverse events at 30 days) and feasibility (successful deployment of all endograft components) of the Aptus Endovascular abdominal aortic aneurysm (AAA) Repair System (Aptus Endosystems, Inc, Sunnyvale, Calif) to treat AAAs. METHODS: A prospective, single arm Federal Drug Administration (FDA) Phase I IDE study was performed. The Aptus endograft is a three-piece modular device with a flexible unsupported main body and two fully supported limbs in a 5.3 mm outer diameter (OD) (16F) delivery system for all iliac limbs and two of three main body sizes. The largest main body (29 mm diameter) is in a 6 mm (18 F OD) delivery system. EndoStaples measuring 4 mm (length) by 3 mm (diameter) designed to provide transmural graft fixation to the adventitia are applied independent of the endograft delivery system. Inclusion criteria included a proximal aortic neck length of 12 mm and iliac landing zone of 10 mm. Secondary endpoints included freedom from endoleaks, rupture, migration, and device integrity. RESULTS: Twenty-one (21) patients were enrolled at five centers. All patients received the Aptus Endograft and EndoStaples. Ninety-six EndoStaples (range, 2-10; median, 4) were implanted. All patients (n = 21) completed 1-month and 6-month follow-up evaluation and 14 completed 1-year follow-up. Two proximal cuffs and one limb extension were used as adjunctive endograft components at implantation. Three secondary interventions were performed in 2 patients for limb thrombosis. There were no EndoStaple-related adverse events, device integrity failures, migrations, or conversions. CONCLUSION: These results of the STAPLE-1 trial document the acute safety and feasibility of the Aptus Endograft and EndoStaples. Early follow-up demonstrates excellent 6-month and 1-year results. A pivotal phase II trial is underway at 25 US centers.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Grampeamento Cirúrgico/instrumentação , Suturas , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/patologia , Implante de Prótese Vascular/efeitos adversos , Estudos de Viabilidade , Feminino , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
11.
J Vasc Surg ; 50(3): 600-7, 607.e1, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19628360

RESUMO

OBJECTIVE: The effects of a new long-term subcutaneous vascular access device were studied in access-challenged patients who were poor candidates for fistulas or grafts due to venous obstruction. Bacteremia rates, patency, and function of the Hemodialysis Reliable Outflow (HeRO) Vascular Access Device (Hemosphere Inc, Minneapolis, Minn) were evaluated. METHODS: The HeRO device consists of a 6-mm expanded polytetrafluoroethylene graft attached to a 5-mm nitinol-reinforced silicone outflow component designed to bypass venous stenoses and enter the internal jugular vein directly, providing continuous arterial blood flow into the right atrium. The HeRO device was studied in a multicenter clinical trial to test the hypothesis that access-challenged patients would experience a statistically significant reduction in bacteremia rates compared with a tunneled dialysis catheter (TDC) literature control of 2.3/1000 days. HeRO-related bacteremia rates, adequacy of dialysis, patency, and adverse events were analyzed. RESULTS: The HeRO device was implanted in 36 access-challenged patients who were followed for a mean 8.6 months (9931 HeRO days). The HeRO-related bacteremia rate was 0.70/1000 days. All HeRO-related bacteremias occurred during the bridging period when a TDC was still implanted before HeRO graft incorporation. HeRO adequacy of dialysis (mean Kt/V) was 1.7. HeRO primary patency was 38.9%, and secondary patency was 72.2%. CONCLUSIONS: In access-challenged patients, a statistically significant reduction in HeRO-related bacteremia was noted compared with TDC literature. The device had similar function and patency compared with conventional arteriovenous graft literature.


Assuntos
Braço/irrigação sanguínea , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Diálise Renal , Ligas , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Infecções Relacionadas a Cateter/microbiologia , Cateterismo Venoso Central/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Estudos Prospectivos , Desenho de Prótese , Infecções Relacionadas à Prótese/microbiologia , Silicones , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
12.
J Vasc Access ; 10(3): 199-202, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19670174

RESUMO

BACKGROUND: The Kidney Disease Outcomes and Quality Initiative (K/DOQI) has developed guidelines from available data suggesting that arteriovenous fistulas (AVF) be performed in the majority of patients. Patient demographics were not included nor suggested in their recommendations. The purpose of this study is to analyze the outcomes of elderly patients, age greater than 70, undergoing first-time permanent access surgery. METHODS: A retrospective review of consecutive patients undergoing new, first time access procedures from January 2005 through December 2005 was performed. Patients with previous attempts at permanent Arteriovenous (AV) access were removed from analysis. Standard statistical methods were used and patency was determined with Kaplan-Meier curves. RESULTS: One hundred and sixty eight patients underwent first time AVF, 48 of whom were older than 70 years of age. Comparing elderly patients to younger ones, the 12 month primary assisted patency was 35% and 67%, respectively (p=0.002) and secondary patency was 36% and 67%, respectively (p=0.004). Of the 48 elderly patients, 48% had died in the subsequent follow up period as compared to just 20% of the 120 patients younger than 70. The 18-month survival for the elderly group was 50% versus 74% for the younger patients (p=0.004). Of the elderly group who died, the average time to death was 13.1 months and only 8 AVF were able to be accessed. Similar intervention rates per year were seen in both groups. DISCUSSION: With an aging population, more patients older than 70 are being evaluated for permanent vascular access. This group poses a difficult dilemma for surgeons attempting to adhere to K/DOQI guidelines. In light of the increased mortality and decreased patency of AVF, this data questions which form of permanent access should be first-line treatment in this subgroup of patients. CONCLUSION: This data suggest in the elderly patients, autogenous fistulas may not be the best option for this set of patients.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Falência Renal Crônica/terapia , Seleção de Pacientes , Diálise Renal , Grau de Desobstrução Vascular , Fatores Etários , Idoso , Cateteres de Demora/efeitos adversos , Feminino , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Humanos , Estimativa de Kaplan-Meier , Falência Renal Crônica/mortalidade , Masculino , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
13.
Clin J Am Soc Nephrol ; 13(3): 501-512, 2018 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-28729383

RESUMO

This paper is part of the Clinical Trial Endpoints for Dialysis Vascular Access Project of the American Society of Nephrology Kidney Health Initiative. The purpose of this project is to promote research in vascular access by clarifying trial end points which would be best suited to inform decisions in those situations in which supportive clinical data are required. The focus of a portion of the project is directed toward arteriovenous access. There is a potential for interventional studies to be directed toward any of the events that may be associated with an arteriovenous access' evolution throughout its life cycle, which has been divided into five distinct phases. Each one of these has the potential for relatively unique problems. The first three of these correspond to three distinct stages of arteriovenous access development, each one of which has been characterized by objective direct and/or indirect criteria. These are characterized as: stage 1-patent arteriovenous access, stage 2-physiologically mature arteriovenous access, and stage 3-clinically functional arteriovenous access. Once the requirements of a stage 3-clinically functional arteriovenous access have been met, the fourth phase of its life cycle begins. This is the phase of sustained clinical use from which the arteriovenous access may move back and forth between it and the fifth phase, dysfunction. From this phase of its life cycle, the arteriovenous access requires a maintenance procedure to preserve or restore sustained clinical use. Using these definitions, clinical trial end points appropriate to the various phases that characterize the evolution of the arteriovenous access life cycle have been identified. It is anticipated that by using these definitions and potential end points, clinical trials can be designed that more closely correlate with the goals of the intervention and provide appropriate supportive data for clinical, regulatory, and coverage decisions.


Assuntos
Derivação Arteriovenosa Cirúrgica , Determinação de Ponto Final , Mãos/irrigação sanguínea , Isquemia/diagnóstico , Enxerto Vascular , Veias/patologia , Aneurisma/diagnóstico , Aneurisma/etiologia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Ensaios Clínicos como Assunto , Constrição Patológica/etiologia , Humanos , Infecções/diagnóstico , Infecções/etiologia , Isquemia/etiologia , Diálise Renal , Trombose/diagnóstico , Trombose/etiologia , Enxerto Vascular/efeitos adversos
14.
Semin Vasc Surg ; 20(3): 158-63, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17884616

RESUMO

The role of prosthetic arteriovenous (AV) access is still important in the management and care of the renal dialysis patients. Multiple new modalities are available to the surgeon today and it is imperative that their role be understood so that optimum care can be delivered to this complex group of patients. This article describes significant changes in prosthetic management and newer configurations available to the surgeon.


Assuntos
Materiais Biocompatíveis , Bioprótese , Prótese Vascular , Diálise Renal/métodos , Derivação Arteriovenosa Cirúrgica/instrumentação , Cateteres de Demora , Humanos , Falência Renal Crônica/terapia , Desenho de Prótese
15.
J Vasc Access ; 17 Suppl 1: S30-1, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26951900

RESUMO

BACKGROUND: The role of the HeRO graft in central venous pathology has been defined in the literature and clinically. There have been two publications or abstracts that have compared the patency rates and outcomes of this graft to the lower extremity graft. AIM: The outcomes of both publications leads to an algorithm suggested by the author in determining which procedure should be used for specific patients. METHODS: Both papers trend to show that lower extremity grafts have improved patency rates when compared to the HeRO device in the upper extremity. DISCUSSION: The author will use these data to demonstrate that in younger patients and in patients with low morbidity and mortality, salvaging the upper extremity area for access may show that the HeRO device provides benefit for these patients.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Falência Renal Crônica/terapia , Extremidade Inferior/irrigação sanguínea , Diálise Renal , Fatores Etários , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Falência Renal Crônica/diagnóstico , Desenho de Prótese , Diálise Renal/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
J Am Coll Surg ; 201(2): 223-30, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16038820

RESUMO

BACKGROUND: The number of patients requiring hemodialysis increases each year, with a large cohort of patients still requiring prosthetic grafts for hemodialysis. All available prosthetic vascular access grafts have predictable failure rates, leading to a large group of patients with multiple failed access grafts. This report evaluates use of mesenteric vein bioprosthesis (MVB) as a conduit for patients who have failed at least one earlier synthetic vascular access graft. STUDY DESIGN: Two-hundred seventy-six access grafts were implanted in patients who had at least one earlier failed synthetic graft. Of these grafts, 183 were MVB and 93 were synthetic. Graft histories were obtained from 128 of the 183 patients who received the MVB, representing a nonrandomized historic data set of previously failed grafts as an internal control group (INT). Patency was determined by Kaplan-Meier analysis, and the Cox proportional hazards model was used for multivariate analysis of factors predictive of effect. RESULTS: Primary patency at 12 months was 35.6% MVB versus 28.4% synthetic grafts. At 24 months, secondary patency was 60.3% MVB, 42.9% synthetic, and 18.0% INT (p < 0.0001, log- rank). Complication rates, including dilation, seroma, infection, and thrombosis, were all notably lower for the MVB compared with synthetic grafts by Cox regression (p < 0.001). Intervention rate per patient year was lower in the MVB group (0.97 versus 1.37) compared with synthetic grafts (p = 0.003). CONCLUSIONS: MVB provided superior secondary graft patency compared with both historic graft data or newly implanted nonrandomized synthetic implants. A considerable reduction in thrombosis, infection, and interventions was observed with the MVB graft. These results suggest that MVB offers a safe alternative to patients who have a history of failing synthetic access grafts and may represent an option for extending vascular access to this patient population.


Assuntos
Bioprótese/normas , Veias Mesentéricas/transplante , Diálise Renal/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Derivação Arteriovenosa Cirúrgica , Bioprótese/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/normas , Bovinos , Infecção Hospitalar/etiologia , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Segurança , Seroma/etiologia , Análise de Sobrevida , Trombose/etiologia , Resultado do Tratamento , Grau de Desobstrução Vascular
17.
J Vasc Access ; 16 Suppl 9: S78-81, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25751557

RESUMO

PURPOSE: The current guidelines for arteriovenous graft (AVG) configuration in hemodialysis state the following sequence: forearm loop, upper arm straight or curved and upper arm looped. These recommendations are based upon literature from the 1980s. Modern patient demographics and patient treatment algorithms, i.e., the Fistula First initiative (FFI), have greatly changed the current practice environment. It is not clear if these changes alter the outcomes of AVGs based upon configuration. METHODS: The most recent National Kidney Foundation Kidney Disease Outcomes Quality Initiative (NKF/K-DOQI) guidelines for vascular access were reviewed. Articles cited to support recommendations for AVG configuration were evaluated. The following search terms: arteriovenous graft configuration, access configuration, PTFE configuration in hemodialysis and straight, looped, curved graft configuration were used to search PubMed, Ovid, Medline and Google scholar. Articles that included data comparing AVG configuration were included. Citations within those articles were examined for publications overlooked in the initial search. Four articles and one abstract were reviewed and separated into pre- and post-FFI groups. RESULTS: Pre-FFI articles demonstrate superiority of forearm looped AVG over straight forearm grafts. Post-FFI, the literature suggests that primary patency, thrombosis and steal are not affected by configuration and location, although looped configuration may have superior secondary patency. CONCLUSIONS: The available literature is mixed regarding the effect of configuration on AVG outcomes. Current studies illustrate the effect may be limited and that larger randomized controlled trials are necessary to draw firm conclusions. Regardless, adequate inflow and an appropriately sized outflow vein are paramount for optimal graft performance.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Implante de Prótese Vascular/métodos , Diálise Renal , Extremidade Superior/irrigação sanguínea , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/normas , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/normas , Humanos , Guias de Prática Clínica como Assunto , Diálise Renal/normas , Resultado do Tratamento
18.
Am. j. kidney dis ; 75(4 supl. 3): S1-S164, Apr. 2020.
Artigo em Inglês | BIGG | ID: biblio-1129967

RESUMO

The National Kidney Foundation's Kidney Disease Outcomes Quality Initiative (KDOQI) has provided evidencebased guidelines for hemodialysis vascular access since 1996. Since the last update in 2006, there has been a great accumulation of new evidence and sophistication in the guidelines process. The 2019 update to the KDOQI Clinical Practice Guideline for Vascular Access is a comprehensive document intended to assist multidisciplinary practitioners care for chronic kidney disease patients and their vascular access. New topics include the end-stage kidney disease "Life-Plan" and related concepts, guidance on vascular access choice, new targets for arteriovenous access (fistulas and grafts) and central venous catheters, management of specific complications, and renewed approaches to some older topics. Appraisal of the quality of the evidence was independently conducted by using a Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach, and interpretation and application followed the GRADE Evidence to Decision frameworks. As applicable, each guideline statement is accompanied by rationale/background information, a detailed justification, monitoring and evaluation guidance, implementation considerations, special discussions, and recommendations for future research


Assuntos
Humanos , Soluções para Hemodiálise/normas , Insuficiência Renal Crônica/terapia , Dispositivos de Acesso Vascular , Medicina Baseada em Evidências
19.
Nat Rev Nephrol ; 10(2): 116-22, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24296629

RESUMO

The population of elderly patients with end-stage renal disease (ESRD) is growing rapidly worldwide. The high prevalence of comorbidities, limited life expectancy and complex quality of life issues associated with this population pose substantial challenges for clinicians in terms of clinical decision-making and providing optimal care. The first dilemma encountered in the management of an elderly patient with ESRD is deciding whether to initiate renal replacement therapy and, if so, selecting the most-suitable dialysis modality. Planning vascular access for haemodialysis is associated with additional challenges. Several clinical practice guidelines recommend an arteriovenous fistula, rather than a central venous catheter or arteriovenous graft, as the preferred access for maintenance haemodialysis therapy. However, whether this recommendation is applicable to elderly patients with ESRD and a limited life expectancy is unclear. Selection and planning of the most appropriate vascular access for an elderly patient with ESRD requires careful consideration of several factors and ultimately should lead to an improvement in the patient's quality of life.


Assuntos
Cateteres de Demora , Tomada de Decisões , Falência Renal Crônica/terapia , Diálise Renal , Idoso , Humanos
20.
J Vasc Access ; 14(2): 143-51, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23172172

RESUMO

PURPOSE: To explore the safety and efficacy of PRT-201. METHODS: Randomized, double-blind, placebo-controlled, single-dose escalation study of PRT-201 (0.0033 to 9 mg) applied after arteriovenous fistula (AVF) creation. Participants were followed for one year. The primary outcome measure was safety. Efficacy measures were the proportion with intra-operative increases in AVF outflow vein diameter or blood flow ≥25% (primary), changes in outflow vein diameter and blood flow, AVF maturation and lumen stenosis by ultrasound criteria and AVF patency. RESULTS: The adverse events in the PRT-201 group (n=45) were similar to those in the placebo group (n=21). There were no differences in the proportion with ≥25% increase in vein diameter or blood flow, successful maturation or lumen stenosis. There was no statistically significant difference in primary patency between the dose groups (placebo n=21, Low Dose n=16, Medium Dose n=17 and High Dose n=12). In a subgroup analysis that excluded three participants with early surgical failures, the hazard ratio (HR) for primary patency loss of Low Dose compared with placebo was 0.38 (95% CI 0.10-1.41, P=0.15). In a Cox model, Low Dose (HR 0.27, 95% CI 0.04-0.79, P=0.09), white race (HR 0.17, 95% CI 0.03-0.79, P=0.02), and age <65 years (HR 0.25, CI 0.05-1.15, P=0.08) were associated (P<0.10) with a decreased risk of primary patency loss. CONCLUSIONS: PRT-201 was not different from placebo for safety or efficacy measures. There was a suggestion for improved AVF primary patency with Low Dose PRT-201 that is now being studied in a larger clinical trial.


Assuntos
Derivação Arteriovenosa Cirúrgica , Proteínas de Transporte/administração & dosagem , Oclusão de Enxerto Vascular/prevenção & controle , Diálise Renal , Trombose/prevenção & controle , Extremidade Superior/irrigação sanguínea , Adulto , Idoso , Análise de Variância , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Método Duplo-Cego , Esquema de Medicação , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Elastase Pancreática , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Trombose/etiologia , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa