Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Macromol Rapid Commun ; 38(12)2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28407331

RESUMO

Novel structures comprised of GaAs nanowire arrays conformally coated with conducting polymers (poly(3,4-ethylenedioxythiophene) (PEDOT) or poly(3,4-ethylenedioxythiophene-co-3-thiophene acetic acid) display both sensitivity and selectivity to a variety of volatile organic chemicals. A key feature is room temperature operation, so that neither a heater nor the power it would consume, is required. It is a distinct difference from traditional metal oxide sensors, which typically require elevated operational temperature. The GaAs nanowires are prepared directly via self-seeded metal-organic chemical deposition, and conducting polymers are deposited on GaAs nanowires using oxidative chemical vapor deposition (oCVD). The range of thickness for the oCVD layer is between 100 and 200 nm, which is controlled by changing the deposition time. X-ray diffraction analysis indicates an edge-on alignment of the crystalline structure of the PEDOT coating layer on GaAs nanowires. In addition, the positive correlation between the improvement of sensitivity and the increasing nanowire density is demonstrated. Furthermore, the effect of different oCVD coating materials is studied. The sensing mechanism is also discussed with studies considering both nanowire density and polymer types. Overall, the novel structure exhibits good sensitivity and selectivity in gas sensing, and provides a promising platform for future sensor design.


Assuntos
Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Nanofios/química , Polímeros/química , Temperatura , Compostos Orgânicos Voláteis/análise , Arsenicais/química , Gálio/química , Difração de Raios X
2.
Macromol Rapid Commun ; 36(13): 1283-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25882241

RESUMO

The synthesis and characterization of poly(3,4-ethylenedioxythiophene) (PEDOT) using water-assisted vapor phase polymerization (VPP) and oxidative chemical vapor deposition (oCVD) are reported. For the VPP PEDOT, the oxidant, FeCl3 , is sublimated onto the substrate from a heated crucible in the reactor chamber and subsequently exposed to 3,4-ethylenedioxythiophene (EDOT) monomer and water vapor in the same reactor. The oCVD PEDOT was produced by introducing the oxidant, EDOT monomer, and water vapor simultaneously to the reactor. The enhancement of doping and crystallinity is observed in the water-assisted oCVD thin films. The high doping level observed at UV-vis-NIR spectra for the oCVD PEDOT, suggests that water acts as a solubilizing agent for oxidant and its byproducts. Although the VPP produced PEDOT thin films are fully amorphous, their conductivities are comparable with that of the oCVD produced ones.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/síntese química , Cloretos/química , Compostos Férricos/química , Polímeros/síntese química , Tiofenos/química , Água/química , Condutividade Elétrica , Membranas Artificiais , Polimerização , Volatilização
3.
J Mater Chem B ; 12(23): 5711-5721, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38758163

RESUMO

The presence of a variety of bacteria is an inevitable/indispensable part of human life. In particular, for patients, the existence and spreading of bacteria lead to prolonged treatment period with many more complications. The widespread use of urinary catheters is one of the main causes for the prevalence of infections. The necessity of long-term use of indwelling catheters is unavoidable in terms of the development of bacteriuria and blockage. As is known, since a permanent solution to this problem has not yet been found, research and development activities continue actively. Herein, polyethylene glycol (PEG)-like thin films were synthesized by a custom designed plasma enhanced chemical vapor deposition (PE-CVD) method and the long-term effect of antifouling properties of PEG-like coated catheters was investigated against Escherichia coli and Proteus mirabilis. The contact angle measurements have revealed the increase of wettability with the increase of plasma exposure time. The antifouling activity of surface-coated catheters was analyzed against the Gram-negative/positive bacteria over a long-term period (up to 30 days). The results revealed that PE-CVD coated PEG-like thin films are highly capable of eliminating bacterial attachment on surfaces with relatively reduced protein attachment without having any toxic effect. Previous statements were supported with SEM, XPS, FTIR spectroscopy, and contact angle analysis.


Assuntos
Escherichia coli , Polietilenoglicóis , Proteus mirabilis , Propriedades de Superfície , Cateteres Urinários , Cateteres Urinários/microbiologia , Escherichia coli/efeitos dos fármacos , Proteus mirabilis/efeitos dos fármacos , Polietilenoglicóis/química , Aderência Bacteriana/efeitos dos fármacos , Incrustação Biológica/prevenção & controle , Humanos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia
4.
J Nanosci Nanotechnol ; 10(4): 2583-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20355467

RESUMO

As biomedical materials, titanium and titanium alloys (Ti-6Al-4V) are superior to many materials in terms of mechanical properties and biocompatibility. However, they are still not sufficient for prolonged clinical use because the biocompatibility of these materials must be improved. In this study, the prevention of the attachment of test microorganism on the Ti alloy surfaces by thiol (-SH) and hydroxyl (-OH) functional group containing monomer in plasma based electron beam generator was reported in order to prepare anti-fouling surfaces. The precursor, 11-mercaptoundecanoic acid is used as plasma source to create nano-film with 30-60 nm approximately. The surface chemistry and topology of uncoated and coated samples are characterized by Fourier Transform Infrared Spectroscopy (FTIR) and Atomic Force Microscopy (AFM). Static contact angle measurements are performed to state the change of surface hydrophilicity. All coated samples are tested in-vitro environment with Staphylococcus epidermidis that is chosen as the test bacteria strain in view of its significance for the pathogenesis of medical-device-related infections. This test is repeated after certain period of times and samples are waited in dynamic fluid media in order to investigate the stability of nano-coating. Plasma polymerized 11-mercaptoundecanoic acid film (PP MUA) with 42 +/- 4 nm is found alternative, stabile and simple method to create bacterial anti-fouling surfaces. The static contact angle of the coated surface is 34 +/- 80 whereas the uncoated surface is 57 +/- 50. For the coated surface, the presence of C-OH and C==O groups in infrared spectra defining the PP MUA is achieved by the plasma polymerization. The attachment of the model microorganism on the biomaterial surface prepared by PP MUA is reduced 85.3% if compared to unmodified control surface.


Assuntos
Ligas/química , Materiais Revestidos Biocompatíveis/química , Cristalização/métodos , Nanoestruturas/química , Staphylococcus epidermidis/fisiologia , Compostos de Sulfidrila/química , Titânio/química , Aderência Bacteriana/fisiologia , Substâncias Macromoleculares/química , Teste de Materiais , Conformação Molecular , Nanoestruturas/ultraestrutura , Nanotecnologia/métodos , Tamanho da Partícula , Propriedades de Superfície
5.
Adv Mater ; 29(19)2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28295681

RESUMO

A novel approach to fabricate supercapacitors (SCs) via vapor printing, specifically oxidative chemical vapor deposition (oCVD), is demonstrated. Compared to stacking multiple layers into a SC, this method enables the monolithic integration of all components into a single-sheet substrate, minimizing the inactive materials and eliminating the possibility of multilayer delamination. Electrodes comprised of pseudocapacitive material, poly(3,4-ethylenedioxythiophene) (PEDOT), are deposited into both sides of a sheet of flexible porous substrate. The film deposition and patterning are achieved in a single step. The oCVD PEDOT penetrates partially into the porous substrate from both surfaces, while leaving the interior of the substrate serving as a separator. Near the surface, the PEDOT coating conforms to the substrate's structure without blocking the pores, resembling the substrate's intrinsic morphology with high surface area. The porously structured PEDOT coating, paired with in situ ion gel electrolyte synthesis, gives enhanced electrode-electrolyte interfaces. The monolithic device demonstrates high volumetric capacitance (11.3 F cm-3 ), energy density (2.98 mWh cm-3 ), and power density (0.42 W cm-3 ). These outstanding performance metrics are attributed to the large loading of active materials, minimization of inactive materials, and good electrode-electrolyte interfaces. SC arrays can be printed on a single substrate without the use of wire interconnects.

6.
ACS Appl Mater Interfaces ; 7(30): 16213-22, 2015 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-26176840

RESUMO

We report a novel room temperature methanol sensor comprised of gold nanoparticles covalently attached to the surface of conducting copolymer films. The copolymer films are synthesized by oxidative chemical vapor deposition (oCVD), allowing substrate-independent deposition, good polymer conductivity and stability. Two different oCVD copolymers are examined: poly(3,4-ethylenedioxythiophene-co-thiophene-3-aceticacid)[poly(EDOT-co-TAA)] and poly(3,4-ehylenedioxythiophene-co-thiophene-3-ethanol)[poly(EDOT-co-3-TE)]. Covalent attachment of gold nanoparticles to the functional groups of the oCVD films results in a hybrid system with efficient sensing response to methanol. The response of the poly(EDOT-co-TAA)/Au devices is found to be superior to that of the other copolymer, confirming the importance of the linker molecules (4-aminothiophenol) in the sensing behavior. Selectivity of the sensor to methanol over n-pentane, acetone, and toluene is demonstrated. Direct fabrication on a printed circuit board (PCB) is achieved, resulting in an improved electrical contact of the organic resistor to the metal circuitry and thus enhanced sensing properties. The simplicity and low fabrication cost of the resistive element, mild working temperature, together with its compatibility with PCB substrates pave the way for its straightforward integration into electronic devices, such as wireless sensor networks.

7.
Opt Lett ; 32(6): 591-3, 2007 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17308570

RESUMO

An experimental study of the use of an S-transform to evaluate the phase distribution from a two-dimensional fringe pattern by introducing the carrier frequencies in two spatial directions, x and y, is presented. The phase distribution is extracted from the optical fringe pattern by using an S-transform gradient and S-transform phase methods. The experimental result for the Fourier transform profilometry algorithm is compared with the results of the S-transform analysis.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa