Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Can J Cardiol ; 32(12): 1575.e21-1575.e23, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27177837

RESUMO

Minimally invasive cardiac surgery techniques offer better cosmesis, quicker recovery, and shorter hospital stay when compared with sternotomy. Large cardiac tumours have been traditionally resected via sternotomy to provide adequate surgical exposure, complete surgical resection, and prevent tumour fragmentation. We describe a patient with advanced multiple sclerosis and wheelchair dependence with a massive obstructive left atrial tumour who underwent successful minimally invasive en bloc resection with an uncomplicated postoperative course.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Átrios do Coração , Neoplasias Cardíacas , Esclerose Múltipla/complicações , Mixoma , Ecocardiografia/métodos , Feminino , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/patologia , Neoplasias Cardíacas/cirurgia , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Limitação da Mobilidade , Mixoma/complicações , Mixoma/patologia , Mixoma/cirurgia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Carga Tumoral
2.
Ann Thorac Surg ; 74(6): 2003-9; discussion 2009, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12643387

RESUMO

BACKGROUND: The St. Jude Medical Regent valve is the next-generation bileaflet aortic prosthesis, modified from the currently marketed St. Jude Medical mechanical valve to achieve a larger geometric orifice without changing the existing design of the pivot mechanism or blood-contact surface areas. The present study reports the hemodynamic and early clinical results of an ongoing multicenter trial investigating the performance of the Regent valve. METHODS: Between July 1998 and July 2001, 361 patients at 17 centers in North America and Europe underwent implantation of a Regent mechanical aortic valve prosthesis. Clinical status was prospectively recorded, and echocardiography with Doppler was performed at discharge and at 2 months, 6 months, 1 year, and 2 years after operation. RESULTS: Follow-up to date is 300 patient-years (average, 0.8 +/- 0.7 years per patient; range, 0.0 to 2.7 years). There were low rates of clinical adverse events. Mean gradient at 6 months was 9.7 +/- 5.3 mm Hg, 7.6 +/- 5.2 mm Hg, 6.3 +/- 3.7 mm Hg, 5.8 +/- 3.4 mm Hg, and 4.0 +/- 2.6 mm Hg, respectively, for 19-mm, 21-mm, 23-mm, 25-mm, and 27-mm valves; effective orifice area was 1.6 +/- 0.4 cm2, 2.0 +/- 0.7 cm2, 2.2 +/- 0.9 cm2, 2.5 +/- 0.9 cm2, and 3.6 +/- 1.3 cm2, respectively. Indexed effective orifice area was equal to or greater than 1.0 cm2/m2 for all valve sizes. Left ventricular mass index decreased significantly between early postoperative (165.9 +/- 57.1 g/m2) and 6-month follow-up (137.9 +/- 41.0 g/m2; delta = -28.0 +/- 49.1 g/m2; p < 0.0001). CONCLUSIONS: The St. Jude Medical Regent aortic valve has excellent hemodynamics and early clinical results, with rapid and significant left ventricular mass regression. Long-term clinical assessment is ongoing.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Adulto , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia Doppler , Feminino , Seguimentos , Ventrículos do Coração/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa