Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Eur Radiol ; 2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38183450

RESUMO

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.

2.
Eur Radiol ; 32(3): 1997-2009, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34655311

RESUMO

OBJECTIVES: Manual assessment of aortic diameters on double-oblique reformatted computed tomography angiograms (CTA) is considered the current standard, although the reproducibility for growth rates has not been reported. Deformable registration of CTA has been proposed to provide 3D aortic diameters and growth maps, but validation is lacking. This study aimed to quantify accuracy and inter-observer reproducibility of registration-based and manual assessment of aortic diameters and growth rates. METHODS: Forty patients with ≥ 2 CTA acquired at least 6 months apart were included. Aortic diameters and growth rate were obtained in the aortic root and the entire thoracic aorta using deformable image registration by two independent observers, and compared with the current standard at typical anatomical landmarks. RESULTS: Compared with manual assessment, the registration-based technique presented low bias (0.46 mm), excellent agreement (ICC = 0.99), and similar inter-observer reproducibility (ICC = 0.99 for both) for aortic diameters; and low bias (0.10 mm/year), good agreement (ICC = 0.82), and much higher inter-observer reproducibility for growth rates (root: ICC = 0.96 vs 0.68; thoracic aorta: ICC = 0.96 vs 0.80). Registration-based growth rate reproducibility over a 6-month-long follow-up was similar to that obtained by manual assessment after 2.7 years (LoA = [- 0.01, 0.33] vs [- 0.13, 0.21] mm/year, respectively). Mapping of diameter and growth rate was highly reproducible (ICC > 0.9) in the whole thoracic aorta. CONCLUSIONS: Registration-based assessment of aortic dilation on CTA is accurate and substantially more reproducible than the current standard, even at follow-up as short as 6 months, and provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks. KEY POINTS: • Registration-based semi-automatic assessment of progressive aortic dilation on CTA is accurate and substantially more reproducible than the current standard. • The registration-based technique allows robust growth rate assessment at follow-up as short as 6 months, with a similar reproducibility to that obtained by manual assessment at around 3 years. • The use of image registration provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Aorta , Aorta Torácica/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
3.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35346239

RESUMO

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Rigidez Vascular , Dissecção Aórtica/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Análise de Onda de Pulso
4.
Eur Radiol ; 31(12): 9262-9272, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33977309

RESUMO

OBJECTIVE: Bicuspid aortic valve (BAV), the most common congenital valve defect, is associated with increased risk of aortic dilation and related complications; however, current risk assessment is not effective. Most of BAV have three leaflets with a fusion between two of them of variable length. This study aimed to ascertain whether the extent of leaflet fusion (often called raphe) is related to aortic dilation and flow abnormalities in BAV with no significant valvular dysfunction. METHODS: One hundred and twenty BAV patients with no significant valvular dysfunction or history of surgical repair or aortic valve replacement were consecutively and prospectively enrolled (September 2014-October 2018). Cardiac magnetic resonance protocol included a 4D flow sequence for haemodynamic assessment. Moreover, a stack of double-oblique cine images of the aortic valve were used to quantify fusion length (in systole) and leaflet length (diastole). Inter- and intra-observer reproducibility was tested in 30 randomly selected patients. RESULTS: Aortic valve leaflet fusion was measurable in 112 of 120 (93%) cases with good reproducibility (ICC = 0.826). Fusion length varied greatly (range: 2.3-15.4 mm; mean: 7.8 ± 3.2 mm). After correction for demographic and clinical conditions, fusion length was independently associated with diameter and z-score at the sinus of Valsalva (p = 0.002 and p = 0.002, respectively) and ascending aorta (p = 0.028 and p = 0.046). Fusion length was positively related to flow asymmetry, vortices and circumferential wall shear stress, thereby possibly providing a pathophysiological link with aortic dilation. CONCLUSIONS: Aortic valve fusion length is related to aortic dilation and flow abnormalities in BAV patients. KEY POINTS: • The length of the fusion between leaflets in non-dysfunctional bicuspid aortic valves varies substantially and can be reliably measured by cine CMR. • Aortic valve leaflet fusion length is independently related to aortic sinus and ascending aorta diameter. • Increased flow asymmetry, circumferential wall shear stress and presence of vortices are positively related to aortic valve leaflet fusion length.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Valva Aórtica/diagnóstico por imagem , Dilatação , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
5.
Arterioscler Thromb Vasc Biol ; 40(1): e10-e20, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31801375

RESUMO

OBJECTIVE: To assess the relationship between regional wall shear stress (WSS) and oscillatory shear index (OSI) and aortic dilation in patients with bicuspid aortic valve (BAV). Approach and Results: Forty-six consecutive patients with BAV (63% with right-left-coronary-cusp fusion, aortic diameter ≤ 45 mm and no severe valvular disease) and 44 healthy volunteers were studied by time-resolved 3-dimensional phase-contrast magnetic resonance imaging. WSS and OSI were quantified at different levels of the ascending aorta and the aortic arch, and regional WSS and OSI maps were obtained. Seventy percent of BAV had ascending aorta dilation. Compared with healthy volunteers, patients with BAV had increased WSS and decreased OSI in most of the ascending aorta and the aortic arch. In both BAV and healthy volunteers, regions of high WSS matched regions of low OSI and vice versa. No regions of both low WSS and high OSI were identified in BAV compared with healthy volunteers. Patients with BAV with dilated compared with nondilated aorta presented low and oscillatory WSS in the aortic arch, but not in the ascending aorta where dilation is more prevalent. Furthermore, no regions of concomitant low WSS and high OSI were identified when BAV were compared according to leaflet fusion pattern, despite the well-known differences in regional dilation prevalence. CONCLUSIONS: Regions with low WSS and high OSI do not match those with the highest prevalence of dilation in patients with BAV, thus providing no evidence to support the low and oscillatory shear stress theory in the pathogenesis of proximal aorta dilation in the presence of BAV.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Fluxo Sanguíneo Regional/fisiologia , Resistência ao Cisalhamento/fisiologia , Adulto , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/fisiopatologia , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Feminino , Seguimentos , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença , Estresse Mecânico
6.
Eur Heart J ; 40(25): 2047-2055, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30977783

RESUMO

AIMS: Life expectancy in Marfan syndrome patients has improved thanks to the early detection of aortic dilation and prophylactic aortic root surgery. Current international clinical guidelines support the use of aortic root diameter as a predictor of complications. However, other imaging markers are needed to improve risk stratification. This study aim to ascertain whether proximal aorta longitudinal and circumferential strain and distensibility assessed by cardiac magnetic resonance (CMR) predict the aortic root dilation rate and aortic events in Marfan syndrome. METHODS AND RESULTS: One hundred and seventeen Marfan patients with no previous aortic dissection, cardiac/aortic surgery, or moderate/severe aortic regurgitation were prospectively included in a multicentre protocol of clinical and imaging follow-up. At baseline, CMR was performed and proximal aorta longitudinal strain and ascending aorta circumferential strain and distensibility were obtained. During follow-up (85.7 [75.0-93.2] months), the annual growth rate of aortic root diameter was 0.62 ± 0.65 mm/year. Fifteen patients underwent elective surgical aortic root replacement and four presented aortic dissection. Once corrected for baseline clinical and demographic characteristics and aortic root diameter, proximal aorta longitudinal strain, but not circumferential strain and distensibility, was an independent predictor of the aortic root diameter growth rate (P = 0.001, P = 0.823, and P = 0.997, respectively), z-score growth rate (P = 0.013, P = 0.672, and P = 0.680, respectively), and aortic events (P = 0.023, P = 0.096, and P = 0.237, respectively). CONCLUSION: Proximal aorta longitudinal strain is independently related to the aortic root dilation rate and aortic events in addition to aortic root diameter, clinical risk factors, and demographic characteristics in Marfan syndrome patients.


Assuntos
Aorta/patologia , Doenças da Aorta/diagnóstico , Dilatação Patológica/diagnóstico , Síndrome de Marfan/complicações , Adulto , Dissecção Aórtica/epidemiologia , Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial/métodos , Diagnóstico Precoce , Feminino , Humanos , Espectroscopia de Ressonância Magnética/métodos , Masculino , Síndrome de Marfan/mortalidade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Espanha/epidemiologia
7.
J Cardiovasc Magn Reson ; 20(1): 28, 2018 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-29695249

RESUMO

BACKGROUND: In patients with bicuspid valve (BAV), ascending aorta (AAo) dilatation may be caused by altered flow patterns and wall shear stress (WSS). These differences may explain different aortic dilatation morphotypes. Using 4D-flow cardiovascular magnetic resonance (CMR), we aimed to analyze differences in flow patterns and regional axial and circumferential WSS maps between BAV phenotypes and their correlation with ascending aorta dilatation morphotype. METHODS: One hundred and one BAV patients (aortic diameter ≤ 45 mm, no severe valvular disease) and 20 healthy subjects were studied by 4D-flow CMR. Peak velocity, flow jet angle, flow displacement, in-plane rotational flow (IRF) and systolic flow reversal ratio (SFRR) were assessed at different levels of the AAo. Peak-systolic axial and circumferential regional WSS maps were also estimated. Unadjusted and multivariable adjusted linear regression analyses were used to identify independent correlates of aortic root or ascending dilatation. Age, sex, valve morphotype, body surface area, flow derived variables and WSS components were included in the multivariable models. RESULTS: The AAo was non-dilated in 24 BAV patients and dilated in 77 (root morphotype in 11 and ascending in 66). BAV phenotype was right-left (RL-) in 78 patients and right-non-coronary (RN-) in 23. Both BAV phenotypes presented different outflow jet direction and velocity profiles that matched the location of maximum systolic axial WSS. RL-BAV velocity profiles and maximum axial WSS were homogeneously distributed right-anteriorly, however, RN-BAV showed higher variable profiles with a main proximal-posterior distribution shifting anteriorly at mid-distal AAo. Compared to controls, BAV patients presented similar WSS magnitude at proximal, mid and distal AAo (p = 0.764, 0.516 and 0.053, respectively) but lower axial and higher circumferential WSS components (p < 0.001 for both, at all aortic levels). Among BAV patients, RN-BAV presented higher IRF at all levels (p = 0.024 proximal, 0.046 mid and 0.002 distal AAo) and higher circumferential WSS at mid and distal AAo (p = 0.038 and 0.046, respectively) than RL-BAV. However, axial WSS was higher in RL-BAV compared to RN-BAV at proximal and mid AAo (p = 0.046, 0.019, respectively). Displacement and axial WSS were independently associated with the root-morphotype, and circumferential WSS and SFRR with the ascending-morphotype. CONCLUSIONS: Different BAV-phenotypes present different flow patterns with an anterior distribution in RL-BAV, whereas, RN-BAV patients present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. Thus, RL-BAV patients present a higher axial WSS at the aortic root while RN-BAV present a higher circumferential WSS in mid and distal AAo. These results may explain different AAo dilatation morphotypes in the BAV population.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adulto , Idoso , Aorta Torácica/patologia , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Estudos de Casos e Controles , Dilatação Patológica , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Estresse Mecânico
8.
Echocardiography ; 34(8): 1122-1129, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28589566

RESUMO

AIMS: To evaluate how often patients with moderate-to-severe or severe mitral regurgitation (MR) meet the anatomical criteria for MitraClip implant and to examine the role of transthoracic echocardiography (TTE) for this task. METHODS AND RESULTS: From February to June 2015, all patients undergoing a TTE in nine Spanish hospitals were prospectively included. Patients with moderate-to-severe and severe mitral regurgitation were selected for analysis. Anatomical eligibility criteria for MitraClip were defined according to the EVEREST trial. A total of 39 855 consecutive TTE were reviewed, and 1403 patients with moderate-to-severe and severe MR were finally included. Primary MR was found in 779 patients (56%). Only in 74 patients (16%), all anatomical criteria for MitraClip could be assessed by TTE. Of these, 56% of patients had optimal valve morphology. Secondary MR was described in 361 patients (26%), and at least 249 of these (69%) had a high surgical risk. All five criteria for MitraClip were adequately assessed by TTE in 299 patients (83%). Of them, 118 patients (39%) had optimal valve morphology. CONCLUSIONS: A considerable proportion of patients have optimal mitral valve morphology for MitraClip. Moreover, TTE was particularly useful in determining whether or not the anatomical criteria for MitraClip implant were met in the majority of patients with secondary MR but in only a minority of those with primary MR.


Assuntos
Ecocardiografia Transesofagiana/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/diagnóstico , Valva Mitral/diagnóstico por imagem , Idoso , Feminino , Seguimentos , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Prevalência , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Espanha/epidemiologia
9.
J Heart Valve Dis ; 25(6): 724-729, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-28290172

RESUMO

BACKGROUND AND AIM OF THE STUDY: Although mitral regurgitation (MR) is a well-recognized prognosis factor, its true prevalence is probably underestimated and its etiology and mechanisms have not been sufficiently explored. The study aim was to evaluate the burden of MR, focusing attention on its frequency, severity, etiology, mechanism, and other associated conditions. METHODS: Between February and June 2015, a total of 39,855 consecutive echocardiographic studies was performed at nine tertiary hospitals, and were prospectively included in the study. MR severity was graded into four groups, ranging from none or trace to severe MR, in accordance with the recommendations of the European Association of Cardiovascular Imaging. Patients with moderate to severe MR were selected for the analysis. RESULTS: MR was detected in 22.6% of cases. MR severity was mild in 82.5% of patients (n = 7,376), moderate in 11.7% (n = 1,048), and severe in 5.8% (n = 521). Concomitant valvular heart disease was present in 3,544 patients (39.7%), with tricuspid regurgitation the most frequently encountered (21.6%). Among moderate and severe MR, primary MR was more frequent than secondary MR (58.8% versus 23.5%), with degenerative valve disease being the most common cause of primary MR (49.2%). A third group composed of mixed forms of MR was described in 17.8% of cases. CONCLUSIONS: MR is a common finding on echocardiography, and is frequently associated with other valvular heart disease. Most MRs are of degenerative origin. The primary and secondary forms of MR differ significantly in their clinical presentation with regard to gender, age, and ventricular function. There appears to be a gap for a 'mixed' group, though further studies are needed to confirm this suggestion.


Assuntos
Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Idoso , Ecocardiografia , Feminino , Doenças das Valvas Cardíacas/complicações , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/epidemiologia , Prevalência , Estudos Prospectivos , Índice de Gravidade de Doença
10.
Enferm Infecc Microbiol Clin ; 34(10): 626-632, 2016 Dec.
Artigo em Espanhol | MEDLINE | ID: mdl-26860418

RESUMO

INTRODUCTION: A growing number of patients with congenital heart disease (CHD) will reach adulthood. Infective endocarditis (IE) is a major complication in this population. The aim of this study was to describe the features of IE in adults with CHD treated in a reference centre. METHODS: A retrospective review was performed on a cohort of patients over 16 years of age with CHD who presented with IE (defined by the modified Duke criteria) between 1996 and 2014. Only the first episode from each patient was considered for the descriptive analysis. RESULTS: IE was observed in 27 patients. The median age at diagnosis of IE was 27.7 years, and 63% were male. Comorbidity was low (median Charlson index was 0). IE was mostly community-acquired (78%). The most frequent CHD were ventricular septal defect (33%). A repair was performed in 48% of patients, and 19% received palliative treatment. Forty-one percent of patients had some type of prosthesis. A residual defect was observed in 81%. The IE was detected in the right side of 44% of the patients. The most frequent aetiological agents were viridans group streptococci (41%) and Staphylococcus epidermidis (30%). Surgery was required to treat IE in 37% of patients. There were five re-infections and three relapses. Two patients died, both as a result of recurrence. CONCLUSIONS: IE in adults with CHD occurred in young patients, and almost all of them carried some prosthetic material or a residual defect. The IE is frequently right-sided. Although surgical treatment was required in many cases, mortality was low, except in the case of relapses.


Assuntos
Endocardite Bacteriana/complicações , Cardiopatias Congênitas/complicações , Adolescente , Adulto , Endocardite Bacteriana/microbiologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Estreptococos Viridans
11.
Anesthesiology ; 120(1): 32-41, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24212199

RESUMO

There has been a recent explosion of education and training in echocardiography in the specialties of anesthesiology and critical care. These devices, by their impact on clinical management, are changing the way surgery is performed and critical care is delivered. A number of international bodies have made recommendations for training and developed examinations and accreditations.The challenge to medical educators in this area is to deliver the training needed to achieve competence into already over-stretched curricula.The authors found an apparent increase in the use of simulators, with proven efficacy in improving technical skills and knowledge. There is still an absence of evidence on how it should be included in training programs and in the accreditation of certain levels.There is a conviction that this form of simulation can enhance and accelerate the understanding and practice of echocardiography by the anesthesiologist and intensivists, particularly at the beginning of the learning curve.


Assuntos
Anestesiologia/educação , Simulação por Computador , Ecocardiografia/tendências , Acreditação , Competência Clínica , Cuidados Críticos , Coração/anatomia & histologia , Coração/fisiologia , Humanos , Manequins
12.
Circulation ; 125(25): 3133-41, 2012 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-22615344

RESUMO

BACKGROUND: Patent false lumen in aortic dissection has been associated with poor prognosis. We aimed to assess the natural evolution of this condition and predictive factors. METHODS AND RESULTS: One hundred eighty-four consecutive patients, 108 surgically treated type A and 76 medically treated type B, were discharged after an acute aortic dissection with patent false lumen. Transesophageal echocardiography was performed before discharge, and computed tomography was performed at 3 months and yearly thereafter. Median follow-up was 6.42 years (quartile 1 to quartile 3: 3.31-10.49). Forty-nine patients died during follow-up (22 type A, 27 type B), 31 suddenly. Surgical or endovascular treatment was indicated in 10 type A and 25 type B cases. Survival free from sudden death and surgical-endovascular treatment was 0.90, 0.81, and 0.46 (95% CI, 0.36-0.55) at 3, 5, and 10 years, respectively. Multivariate analysis identified baseline maximum descending aorta diameter (hazard ratio [HR]: 1.32 [1.10-1.59]; P=0.003), proximal location (HR: 1.84 [1.06-3.19]; P=0.03), and entry tear size (HR: 1.13 [1.08-1.2]; P<0.001) as predictors of dissection-related adverse events, whereas mortality was predicted by baseline maximum descending aorta diameter (HR: 1.36 [1.08-1.70]; P=0.008), entry tear size (HR: 1.1 [1.04-1.16]; P=0.001), and Marfan syndrome (HR: 3.66 [1.65-8.13]; P=0.001). CONCLUSIONS: Aortic dissection with persistent patent false lumen carries a high risk of complications. In addition to Marfan syndrome and aorta diameter, a large entry tear located in the proximal part of the dissection identifies a high-risk subgroup of patients who may benefit from earlier and more aggressive therapy.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/terapia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/terapia , Adulto , Idoso , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/mortalidade , Feminino , Seguimentos , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
13.
Eur Heart J Cardiovasc Imaging ; 24(8): 1120-1128, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37131301

RESUMO

AIMS: To assess the progression of the disease and evolution of the main echocardiographic variables for quantifying AS in patients with severe low-flow low-gradient (LFLG) AS compared to other severe AS subtypes. METHODS AND RESULTS: Longitudinal, observational, multicenter study including consecutive asymptomatic patients with severe AS (aortic valve area, AVA < 1.0 cm²) and normal left ventricle ejection fraction (LVEF ≥ 50%). Patients were classified according to baseline echocardiography into: HG (high gradient; mean gradient ≥ 40 mmHg), NFLG (normal-flow low-gradient; mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35mL/m2), or LFLG (mean gradient < 40 mmHg, SVi ≤ 35 mL/m²). AS progression was analyzed by comparing patients' baseline measurements and their last follow-up measurements or those taken prior to aortic valve replacement (AVR). Of the 903 included patients, 401 (44.4%) were HG, 405 (44.9%) NFLG, and 97 (10.7%) LFLG. Progression of the mean gradient in a linear mixed regression model was greater in low-gradient groups: LFLG vs. HG (regression coefficient 0.124, P = 0.005) and NFLG vs. HG (regression coefficient 0.068, P = 0.018). No differences were observed between the LFLG and NFLG groups (regression coefficient 0.056, P = 0.195). However, AVA reduction was slower in the LFLG group compared to the NFLG (P < 0.001). During follow-up, in conservatively-managed patients, 19.1% (n = 9) of LFLG patients evolved to having NFLG AS and 44.7% (n = 21) to having HG AS. In patients undergoing AVR, 58.0% (n = 29) of LFLG baseline patients received AVR with a HG AS. CONCLUSION: LFLG AS shows an intermediate AVA and gradient progression compared to NFLG and HG AS. The majority of patients initially classified as having LFLG AS changed over time to having other severe forms of AS, and most of them received AVR with a HG AS.


Assuntos
Estenose da Valva Aórtica , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Valva Aórtica/diagnóstico por imagem , Função Ventricular Esquerda , Volume Sistólico , Índice de Gravidade de Doença , Resultado do Tratamento , Estudos Retrospectivos
14.
Can J Cardiol ; 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38013065

RESUMO

BACKGROUND: Percutaneous mitral paravalvular leak (PVL) closure techniques are an effective and safe alternative to surgical treatment, but data regarding long-term outcomes are scarce. We aim to describe the impact of successful percutaneous mitral PVL closure on long-term outcomes. METHODS: All consecutive patients in whom a first-attempt percutaneous mitral PVL closure was performed in a single tertiary centre between January 2010 and October 2021 were included. Clinical variables, procedural details, and procedural success were collected. Patients were classified based on procedural success, defined as no more than mild residual leak. All-cause mortality was the primary endpoint. Cardiovascular death and heart failure hospitalizations (HFHs) were key secondary endpoints. RESULTS: Ninety patients (median age 72.5 years [66.0-78.4]; median EuroSCORE-II 8.2 [5.3-12.46]) were included. Although reduction of at least 1 degree in PVL severity was achieved in 82 (91.1%), procedural success was achieved in 47 (52.2%). Chronic kidney disease, previous surgery for PVL, and the presence of multiple jets were independently associated with procedural failure. After a median follow-up of 3.2 (1.2-5.2) years, mortality rate was higher in the procedural failure group (27.3 per 100 patients-years) compared with the group with successful closure (8.2 per 100 patient-years). Procedural failure was associated with all-cause death (adjusted hazard ratio [aHR], 2.59; 95% confidence interval [CI], 1.41-4.78), cardiovascular death (aHR, 3.53; 95% CI, 1.67-7.49) and HFH (aHR, 3.27; 95% CI,1.72-6.20). CONCLUSIONS: A successful reduction in PVL to mild or absent is associated with improved rates of all-cause death, cardiovascular death, and HFHs.

15.
J Clin Med ; 11(2)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35054153

RESUMO

Multimodality imaging is the basis of the diagnosis, follow-up, and surgical management of bicuspid aortic valve (BAV) patients. Transthoracic echocardiography (TTE) is used in our clinical routine practice as a first line imaging for BAV diagnosis, valvular phenotyping and function, measurement of thoracic aorta, exclusion of other aortic malformations, and for the assessment of complications such are infective endocarditis and aortic. Nevertheless, TTE is less useful if we want to assess accurately other aortic segments such as mid-distal ascending aorta, where computed tomography (CT) and magnetic resonance (CMR) could improve the precision of aorta size measurement by multiplanar reconstructions. A major advantage of CT is its superior spatial resolution, which affords a better definition of valve morphology and calcification, accuracy, and reproducibility of ascending aorta size, and allows for coronary artery assessment. Moreover, CMR offers the opportunity of being able to evaluate aortic functional properties and blood flow patterns. In this setting, new developed sequences such as 4D-flow may provide new parameters to predict events during follow up. The integration of all multimodality information facilitates a comprehensive evaluation of morphologic and dynamic features, stratification of the risk, and therapy guidance of this cohort of patients.

16.
Eur Heart J Cardiovasc Imaging ; 23(5): 641-649, 2022 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-34104946

RESUMO

AIMS: To assess aortic flow and stiffness in patients with Loeys-Dietz syndrome (LDS) by 4D flow and cine cardiovascular magnetic resonance (CMR) and compare the results with those of healthy volunteers (HV) and Marfan syndrome (MFS) patients. METHODS AND RESULTS: Twenty-one LDS and 44 MFS patients with no previous aortic dissection or surgery and 35 HV underwent non-contrast-enhanced 4D flow CMR. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), and aortic diameters were obtained at 20 planes from the ascending (AAo) to the proximal descending aorta (DAo). IRF and SFRR were also quantified for aortic regions (proximal and distal AAo, arch and proximal DAo). Peak-systolic wall shear stress (WSS) maps were also estimated. Aortic stiffness was quantified using pulse wave velocity (PWV) and proximal AAo longitudinal strain. Compared to HV, LDS patients had lower rotational flow at the distal AAo (P = 0.002), arch (P = 0.002), and proximal DAo (P < 0.001) even after adjustment for age, stroke volume, and local diameter. LDS patients had higher SFRR in the proximal DAo compared to both HV (P = 0.024) and MFS patients (P = 0.015), even after adjustment for age and local diameter. Axial and circumferential WSS in LDS patients were lower than in HV. AAo circumferential WSS was lower in LDS compared to MFS patients. AAo and DAo PWV and proximal AAo longitudinal strain revealed stiffer aortas in LDS patients compared to HV (P = 0.007, 0.005, and 0.029, respectively) but no differences vs. MFS patients. CONCLUSION: Greater aortic stiffness as well as impaired IRF and WSS were present in LDS patients compared to HV. Conversely, similar aortic stiffness and overlapping aortic flow features were found in Loeys-Dietz and Marfan patients.


Assuntos
Síndrome de Loeys-Dietz , Síndrome de Marfan , Rigidez Vascular , Aorta/diagnóstico por imagem , Aorta/patologia , Voluntários Saudáveis , Humanos , Síndrome de Loeys-Dietz/diagnóstico por imagem , Síndrome de Loeys-Dietz/patologia , Síndrome de Marfan/diagnóstico por imagem , Análise de Onda de Pulso
17.
JACC Cardiovasc Imaging ; 15(1): 46-56, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34801463

RESUMO

OBJECTIVES: This study sought to assess the predictive value of wall shear stress (WSS) for colocalized ascending aorta (AAo) growth rate (GR) in patients with bicuspid aortic valve (BAV). BACKGROUND: BAV is associated with AAo dilation, but there is limited knowledge about possible predictors of aortic dilation in patients with BAV. An increased WSS has been related to aortic wall damage in patients with BAV, but no previous prospective study tested its predictive value for dilation rate. Recently, a registration-based technique for the semiautomatic mapping of aortic GR has been presented and validated. METHODS: Forty-seven patients with BAV free from valvular dysfunction prospectively underwent 4-dimensional flow cardiac magnetic resonance to compute WSS and subsequent follow-up with 2 electrocardiogram-gated high-resolution contrast-enhanced computed tomography angiograms for GR assessment. RESULTS: During a median follow-up duration of 43 months, mid AAo GR was 0.24 mm/year. WSS and its circumferential component showed statistically significant association with mid AAo GR in bivariate (P = 0.049 and P = 0.014, respectively) and in multivariate analysis corrected for stroke volume and either baseline AAo diameter (P = 0.046 and P = 0.014, respectively) or z-score (P = 0.036 and P = 0.012, respectively). GR mapping further detailed that GR was heterogeneous in the AAo and that circumferential WSS, but not WSS magnitude, showed statistically significant positive associations with GR in the regions with the fastest growth. CONCLUSIONS: 4D flow cardiac magnetic resonance-derived WSS and, in particular, its circumferential component predict progressive dilation of the ascending aorta in patients with BAV. Thus, the assessment of WSS may be considered in the follow-up of these patients.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Valva Aórtica/diagnóstico por imagem , Dilatação , Hemodinâmica , Humanos , Valor Preditivo dos Testes
18.
Int J Cardiol Heart Vasc ; 39: 100977, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35281755

RESUMO

Background: Atrial fibrillation (AF) is one of the most prevalent causes of cryptogenic stroke. Also, apart from AF itself, structural and remodelling changes in the atria might be an underlying cause of cryptogenic stroke. We aimed to discover circulating proteins and reveal pathways altered in AF and atrial cardiomyopathy, measured by left atrial volume index (LAVI) and peak atrial longitudinal strain (PALS), in patients with cryptogenic stroke. Methods: An aptamer array (including 1310 proteins) was measured in the blood of 20 cryptogenic stroke patients monitored during 28 days with a Holter device as a case-control study of the Crypto-AF cohort. Protein levels were compared between patients with (n = 10) and without AF (n = 10) after stroke, and the best candidates were tested in 111 patients from the same cohort (44 patients with AF and 67 without AF). In addition, in the first 20 patients, proteins were explored according to PALS and LAVI values. Results: Forty-six proteins were differentially expressed in AF cases. Of those, four proteins were tested in a larger sample size. Only DPP7, presenting lower levels in AF patients, was further validated. Fifty-seven proteins correlated with LAVI, and 270 correlated with PALS. NT-proBNP was common in all the discovery analyses performed. Interestingly, many proteins and pathways were altered in patients with low PALS. Conclusions: Multiple proteins and pathways related to AF and atrial cardiomyopathy have been revealed. The role of DPP7 as a biomarker for stroke aetiology should be further explored. Moreover, the present study may be considered hypothesis-generating.

19.
Front Cardiovasc Med ; 9: 908053, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35859587

RESUMO

Background: Atrial fibrillation (AF) increases the risk of ischemic stroke in asymptomatic individuals and may be the underlying cause of many cryptogenic strokes. We aimed to test the usefulness of candidate blood-biomarkers related to AF pathophysiology in two prospective cohorts representative of those populations. Methods: Two hundred seventy-four subjects aged 65-75 years with hypertension and diabetes from the AFRICAT cohort, and 218 cryptogenic stroke patients aged >55 years from the CRYPTO-AF cohort were analyzed. AF was assessed by 4 weeks of monitoring with a wearable Holter device (NuuboTM™). Blood was collected immediately before monitoring started. 10 candidate biomarkers were measured by automated immunoassays (Roche, Penzberg) in the plasma of all patients. Univariate and logistic regression analyses were performed in each cohort separately. Results: Atrial fibrillation detection rate was 12.4% (AFRICAT cohort) and 22.9% (CRYPTO-AF cohort). 4 biomarkers were significantly increased in asymptomatic individuals with AF [Troponin-T, Angiopoietin-2 (Ang-2), Endocan, and total N-terminal pro-B type natriuretic peptide (NT-proBNP)] and 7 biomarkers showed significantly higher concentrations in cryptogenic stroke patients with AF detection [growth differentiation factor 15, interleukin 6, Troponin-T, Ang-2, Bone morphogenic protein 10, Dickkopf-related protein 3 (DKK-3), and total NT-proBNP]. The models including Ang-2 and total NT-proBNP [AUC 0.764 (0.665-0.863)], and Ang-2 and DKK-3 [AUC = 0.733 (0.654-0.813)], together with age and sex, showed the best performance to detect AF in high-risk asymptomatic individuals, and in cryptogenic stroke patients, respectively. Conclusion: Blood-biomarkers, in particular, total NT-proBNP, DKK-3, and Ang-2, were associated with AF reflecting two mechanistically different pathways involved in AF pathophysiology (AF stretch and vascular changes). The combination of these biomarkers could be useful in AF screening strategies in the primary care setting and also for searching AF after cryptogenic stroke.

20.
Front Cardiovasc Med ; 9: 852954, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35433871

RESUMO

Objectives: To determine the risk of mortality and need for aortic valve replacement (AVR) in patients with low-flow low-gradient (LFLG) aortic stenosis (AS). Methods: A longitudinal multicentre study including consecutive patients with severe AS (aortic valve area [AVA] < 1.0 cm2) and normal left ventricular ejection fraction (LVEF). Patients were classified as: high-gradient (HG, mean gradient ≥ 40 mmHg), normal-flow low-gradient (NFLG, mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35 ml/m2) and LFLG (mean gradient < 40 mmHg, SVi ≤ 35 ml/m2). Results: Of 1,391 patients, 147 (10.5%) had LFLG, 752 (54.1%) HG, and 492 (35.4%) NFLG. Echocardiographic parameters of the LFLG group showed similar AVA to the HG group but with less severity in the dimensionless index, calcification, and hypertrophy. The HG group required AVR earlier than NFLG (p < 0.001) and LFLG (p < 0.001), with no differences between LFLG and NFLG groups (p = 0.358). Overall mortality was 27.7% (CI 95% 25.3-30.1) with no differences among groups (p = 0.319). The impact of AVR in terms of overall mortality reduction was observed the most in patients with HG (hazard ratio [HR]: 0.17; 95% CI: 0.12-0.23; p < 0.001), followed by patients with LFLG (HR: 0.25; 95% CI: 0.13-0.49; p < 0.001), and finally patients with NFLG (HR: 0.29; 95% CI: 0.20-0.44; p < 0.001), with a risk reduction of 84, 75, and 71%, respectively. Conclusions: Paradoxical LFLG AS affects 10.5% of severe AS, and has a lower need for AVR than the HG group and similar to the NFLG group, with no differences in mortality. AVR had a lower impact on LFLG AS compared with HG AS. Therefore, the findings of the present study showed LFLG AS to have an intermediate clinical risk profile between the HG and NFHG groups.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa