Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Molecules ; 24(20)2019 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-31658737

RESUMO

The mixed-ligand strategy was selected as an approach to tailor a metal-organic framework (MOF) with microextraction purposes. The strategy led to the synthesis of up to twelve UiO-66-based MOFs with different amounts of functionalized terephthalate ligands (H-bdc), including nitro (-NO2) and amino (-NH2) groups (NO2-bdc and NH2-bdc, respectively). Increases of 25% in ligands were used in each case, and different pore environments were thus obtained in the resulting crystals. Characterization of MOFs includes powder X-ray diffraction, infrared spectroscopy, and elemental analysis. The obtained MOFs with different degrees and natures of functionalization were tested as sorbents in a dispersive miniaturized solid-phase extraction (D-µSPE) method in combination with high-performance liquid chromatography (HPLC) and diode array detection (DAD), to evaluate the influence of mixed functionalization of the MOF on the analytical performance of the entire microextraction method. Eight organic pollutants of different natures were studied, using a concentration level of 5 µg· L-1 to mimic contaminated waters. Target pollutants included carbamazepine, 4-cumylphenol, benzophenone-3, 4-tert-octylphenol, 4-octylphenol, chrysene, indeno(1,2,3-cd)pyrene, and triclosan, as representatives of drugs, phenols, polycyclic aromatic hydrocarbons, and disinfectants. Structurally, they differ in size and some of them present polar groups able to form H-bond interactions, either as donors (-NH2) or acceptors (-NO2), permitting us to evaluate possible interactions between MOF pore functionalities and analytes' groups. As a result, extraction efficiencies can reach values of up to 60%, despite employing a microextraction approach, with four main trends of behavior being observed, depending on the analyte and the MOF.


Assuntos
Estruturas Metalorgânicas/química , Hidrocarbonetos Policíclicos Aromáticos/química , Microextração em Fase Sólida , Cromatografia Líquida de Alta Pressão , Ligantes
2.
Medicentro ; 8(2)jun. 2004. tab
Artigo em Espanhol | CUMED | ID: cum-31630

RESUMO

Se practicó la técnica de ultrasonido de vaciamiento vesicular a 2 604 pacientes con diagnóstico presuntivo de colecistopatía alitiásica, con el objetivo de demostrar la efectividad de la técnica ultrasonográfica. Dicho estudio fue realizado en la sección de ultrasonido del departamento de Radiología del Hospital Universitario “Arnaldo Milián Castro”, en el período comprendido entre enero de 1994 y enero de 2001.Se utilizó un equipo de ultrasonido COMBISON 310 (KRETZ) con transductor de 3,5 MHZ. Para evaluar la actividad cinética de la vesícula biliar se tomó como patrón sonométrico su volumen, se realizó la primera medición con el paciente en ayunas y la segunda a la hora de haber ingerido una comida rica en grasa. La contractilidad y el vaciamiento vesicular se consideró normal cuando el volumen de la vesícula se redujo en un 50 por ciento o más al realizar la segunda medición. Se establecieron relaciones entre la colecistografía oral y el ultrasonido de vaciamiento vesicular en relación con preparación, contraindicaciones y causa de estudio no útil. En los pacientes intervenidos quirúrgicamente se correlacionaron hallazgos sonográficos e histológicos. Se demostró la superioridad de la técnica ultrasonográfica sobre la colecistografía oral(AU)


Assuntos
Humanos , Esvaziamento da Vesícula Biliar , Colecistite , Colecistografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa