Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
Phys Rev Lett ; 133(5): 055102, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39159102

RESUMO

At present, magnetic confinement fusion devices rely solely on absolute neutron counting as a direct way of measuring fusion power. Absolute counting of deuterium-tritium gamma rays could provide the secondary neutron-independent technique required for the validation of scientific results and as a licensing tool for future power plants. However, this approach necessitates an accurate determination of the gamma-ray-to-neutron branching ratio. The gamma-ray-to-neutron branching ratio for the deuterium-tritium reaction ^{3}H(^{2}H,γ)^{5}He/^{3}H(^{2}H,n)^{4}He was determined in magnetic confinement fusion plasmas at the Joint European Torus in predominantly deuterium beam heated plasmas. The branching ratio was found to be equal to (2.4±0.5)×10^{-5} over the deuterium energy range of (80±20) keV. This accurate determination of the deuterium-tritium branching ratio paves the way for a direct and neutron-independent measurement of fusion power in magnetic confinement fusion reactors, based on the absolute counting of deuterium-tritium gamma rays.

2.
Rep Prog Phys ; 79(9): 094301, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27502571

RESUMO

Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

3.
Health Educ Res ; 31(4): 439-49, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27288347

RESUMO

The aim of this study was to investigate factors mediating the effects of Luoghi di Prevenzione (LdP) smoking prevention intervention based on social competence and social influence approaches, and characterized by peer-led school-based interventions, out-of-school workshops, school lessons, and by enforcing the school anti-smoking policy. Students aged 14-15 years in 13 secondary schools in Reggio Emilia, Italy (989 students) were randomly assigned to the LdP intervention or a control condition. The baseline and follow-up surveys were carried out before and 18 months after the intervention, respectively.The outcomes were cigarette daily and frequent smoking and smoking at school. Multilevel multiple mediation analyses were carried out in order to study effect mediation. The mediators were normative perception, positive and negative beliefs, refusal skills for smoking, social acceptability perception, risk perception, smoking knowledge and awareness about dangers of second-hand smoking.The intervention effects were explained by the social influence component through the mediator refusal skills for smoking. The programme also showed to significantly increase risk perception and smoking knowledge, even though these mediators had no effect on smoking. Moreover, LdP intervention directly reduced smoking in school areas. Future interventions should maintain and strengthen the LdP social influence component and the part regarding the school anti-smoking policy.


Assuntos
Serviços de Saúde Escolar , Prevenção do Hábito de Fumar/métodos , Adolescente , Atitude Frente a Saúde , Feminino , Humanos , Masculino , Serviços de Saúde Escolar/organização & administração , Fumar/epidemiologia , Prevenção do Hábito de Fumar/organização & administração
4.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39087810

RESUMO

A COmpact Spectrometer for Measurements Of Neutrons at the ASDEX Upgrade Tokamak (COSMONAUT) has been developed for spectroscopy measurements of the 2.45 MeV neutron emission from deuterium plasmas at the ASDEX Upgrade. The instrument is based on a CLYC-7 inorganic scintillator, whereby the detection of fusion neutrons occurs via their interaction with 35Cl nuclei in the detector crystal, leading to a peak in the detector response function and providing excellent neutron/gamma-ray discrimination capabilities. The diagnostics is installed along a radial line of sight and makes use of a digital system to record time resolved data for the whole duration of the discharge. Measurements in ASDEX Upgrade plasmas with neutral beam injection have been carried out and are successfully interpreted using state-of-the-art modeling codes. Next step applications of the diagnostics are in experiments aimed at generating energetic particles by ion cyclotron resonance heating schemes. In these scenarios, COSMONAUT will provide unique information on the acceleration of deuterons beyond the beam injection energy and on their confinement, for comparison with modeling.

5.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39093115

RESUMO

A new 14 MeV neutron spectrometer utilizing the magnetic proton recoil (MPR) technique is under development for the SPARC tokamak. This instrument measures neutrons by converting them into protons, whose momenta are subsequently analyzed using a series of magnets before detection by an array of scintillators known as the hodoscope. In this work, we explore various solutions for the hodoscope detectors through laboratory tests with radioactive sources and simulations. We present findings on light collection and pulse shape discrimination based on detector types, as well as optimal solutions for photo-detectors studying the differences between SiPM and PMT. Our results also led to the determination of a better optimized design for the hodoscope detectors, consisting of a 0.7 cm width and a 13 cm length EJ276D scintillation rod.

6.
J Phys Condens Matter ; 36(38)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38885691

RESUMO

This paper describes the physical modelling of neutron scattering in two polycrystalline inclusion compounds, fully deuterated clathrate hydrate andC60, each with paramagnetic oxygen as guest molecules. For studying the suitability of these materials for neutron moderation to very low energies, the model includes, in addition to the magnetic neutron scattering by the oxygen, the nuclear scattering by all constituents. The theoretical total cross sections are calculated based on the phonon density of states obtained by density functional theory and molecular dynamics simulations. At low temperatures, the developed scattering kernels are in good agreement with experimental neutron scattering data reported in the literature. At 20 K and above, a Lorentzian distribution for the zero-field splitting of the magnetic substates of the spin triplet of the oxygen molecules helps to reproduce magnetic peaks observed in inelastic neutron scattering experiments better than the original theory based on a single-valued splitting constant. Neutron spectra obtained by Monte Carlo simulations in infinite media are presented, highlighting the potential use ofO2-containing fully deuterated clathrate hydrate as a neutron moderator for the production of very cold neutrons.

7.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39101791

RESUMO

The ITER Radial Gamma-Ray Spectrometer (RGRS) consists of three gamma-ray detectors observing the plasma through three collimated, coplanar, radial lines of sight (LoS). The system was initially designed to monitor the runaway electron emission and the alpha-particle density profile [Nocente et al., Nucl. Fusion 57, 076016 (2017)]. This work presents a novel technique for measuring the fusion power during D-T operation using the RGRS. This method is based on the absolute measurement of the 17 MeV fusion gamma-rays and a semi-analytical computation of their transport from the plasma source to the detectors. This approach was initially developed and tested at JET during the second D-T campaign (DTE2) on a single LoS diagnostic [Dal Molin et al., Phys. Rev. Lett. (submitted) (2024); Rebai et al., Phys. Rev. C (submitted) (2024); and Marcer et al., Nucl. Fusion (unpublished) (2024)]. This work exploits the multiple LoS of the RGRS to create a combined virtual diagnostic whose detected fraction of the total plasma emission is less affected by variations in the plasma emission profile, reducing systematic uncertainties on the estimated total emission, compared to the individual detectors.

8.
Rev Sci Instrum ; 94(1): 013501, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725552

RESUMO

The only method for assessing the fusion power throughput of a deuterium-tritium (DT) reactor presently relies on determining the absolute number of 14 MeV neutrons produced in the DT plasma. An independent method, developed and investigated during the recent DT campaign at the Joint European Torus, is based on the absolute counting of 17 MeV gamma rays produced by the competing T(D, γ)5He reaction that features a very weak branching ratio (about 3-6 × 10-6) when compared to the main T(D, n)4He reaction. The state-of-the-art spectrometer used for gamma-ray measurements in magnetic confinement fusion plasmas is LaBr3(Ce) scintillator detectors, although they require significant neutron shielding to extract a relatively weak gamma-ray signal from a much more abundant neutron field. A better approach relies on a gamma-ray detector that is intrinsically insensitive to neutrons. We have advanced the design of a gamma-ray counter based on the Cherenkov effect for gamma-rays whose energy exceeds 11 MeV, optimized to work in the neutron-rich environment of a steady-state, magnetically confined fusion plasma device. The gamma-rays interact with an aluminum window and extract electrons that move into the radiator emitting photons via the Cherenkov effect. Since the Cherenkov light consists of few photons (25 on average) in the far UV band (100-200 nm), a pre-amplifier is required to transport the photons to the neutron-shielded location, which may be a few meters away, where the readout elements of the detector, either a silicon or standard photomultiplier tube, are placed. The present work focuses on the development of a scintillating GEM (Gas Electron Multiplier) based pre-amplifier that acts as a Cherenkov photon pre-amplifier and wavelength shifter. This paper presents the result of a set of Garfield++ simulations developed to find the optimal GEM working parameters. A photon gain of 100 is obtained by biasing a single GEM foil to 1 kV.

9.
Rev Sci Instrum ; 93(9): 093515, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182493

RESUMO

The Joint European Torus (JET) is the only tokamak in the world able to operate in Deuterium-Tritium (DT) plasmas. A successful DT experimental campaign, the DTE2, has recently been carried out, providing unique opportunities for studying both physics and technological aspects. In particular, it allowed us to investigate and benchmark the solutions adopted to attenuate the significant 14 MeV neutron flux, needed to enable high-resolution gamma-ray spectroscopy measurements on a tokamak. While in inertial confinement experiments, gamma-rays and neutrons are discriminated through time-of-flight techniques; in magnetic confinement experiments, the neutron attenuators are a key element to allow gamma-ray measurements in order to reestablish the 1 × 105 to 1 background to signal ratio. In this paper, the role of the reference neutron attenuators at JET, based on LiH, has been analyzed and described.

10.
Rev Sci Instrum ; 93(11): 113501, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461431

RESUMO

The EAST plasmas heated with deuterium neutral beam injection and ion cyclotron resonance heating (ICRH) have been simulated by the TRANSP code. The analysis has been conducted using the full wave solver TORIC5, the radio frequency (RF)-kick operator, and NUBEAM to model the RF heating effects on fast ion velocity distribution. In this work, we present several simulated results compared with experiments for high power EAST scenarios, indicating that the interactions between ICRH and fast ions can significantly accelerate fast ions, which are confirmed by the increased neutron yield and broadened neutron emission spectrum measurements.

11.
Rev Sci Instrum ; 93(9): 093525, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182521

RESUMO

The most performant deuterium-tritium (DT) plasma discharges realized by the Joint European Torus (JET) tokamak in the recent DT campaign have produced neutron yields on the order of 1018 n/s. At such high neutron yields, gamma-ray spectroscopy measurements with scintillators are challenging as events from the neutron-induced background often dominate over the signal, leading to a significant fraction of pileup events and instability of the photodetector gain along with the consequent degradation of the reconstructed spectrum. Here, we describe the solutions adopted for the tangential lanthanum bromide spectrometer installed at JET. A data acquisition system with free streaming mode digitization capabilities for the entire duration of the discharge has been used to solve dead-time related issues and a data reconstruction code with pileup recovery and photodetector gain drift restoration has been implemented for off-line analysis of the data. This work focuses on the acquired data storage and parsing, with a detailed explanation of the pileup recovery and gain drift restoration algorithms.

12.
Rev Sci Instrum ; 93(11): 113512, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461481

RESUMO

Dedicated nuclear diagnostics have been designed, developed, and built within EUROFUSION enhancement programs in the last ten years for installation at the Joint European Torus and capable of operation in high power Deuterium-Tritium (DT) plasmas. The recent DT Experiment campaign, called DTE2, has been successfully carried out in the second half of 2021 and provides a unique opportunity to evaluate the performance of the new nuclear diagnostics and for an understanding of their behavior in the record high 14 MeV neutron yields (up to 4.7 × 1018 n/s) and total number of neutrons (up to 2 × 1019 n) achieved on a tokamak. In this work, we will focus on the 14 MeV high resolution neutron spectrometers based on artificial diamonds which, for the first time, have extensively been used to measure 14 MeV DT neutron spectra with unprecedented energy resolution (Full Width at Half Maximum of ≈1% at 14 MeV). The work will describe their long-term stability and operation over the DTE2 campaign as well as their performance as neutron spectrometers in terms of achieved energy resolution and high rate capability. This important experience will be used to outline the concept of a spectroscopic neutron camera for the SPARC tokamak. The proposed neutron camera will be the first one to feature the dual capability to measure (i) the 2.5 and 14 MeV neutron emissivity profile via the conventional neutron detectors based on liquid or plastics scintillators and (ii) the 14 MeV neutron spectral emission via the use of high-resolution diamond-based spectrometers. The new opportunities opened by the spectroscopic neutron camera to measure plasma parameters will be discussed.

13.
Rev Sci Instrum ; 93(9): 093520, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182523

RESUMO

A new deuterium-tritium experimental, DTE2, campaign has been conducted at the Joint European Torus (JET) between August 2021 and late December 2021. Motivated by significant enhancements in the past decade at JET, such as the ITER-like wall and enhanced auxiliary heating power, the campaign achieved a new fusion energy world record and performed a broad range of fundamental experiments to inform ITER physics scenarios and operations. New capabilities in the area of fusion product measurements by nuclear diagnostics were available as a result of a decade long enhancement program. These have been tested for the first time in DTE2 and a concise overview is provided here. Confined alpha particle measurements by gamma-ray spectroscopy were successfully demonstrated, albeit with limitations at neutron rates higher than some 1017 n/s. High resolution neutron spectroscopy measurements with the magnetic proton recoil instrument were complemented by novel data from a set of synthetic diamond detectors, which enabled studies of the supra-thermal contributions to the neutron emission. In the area of escaping fast ion diagnostics, a lost fast ion detector and a set of Faraday cups made it possible to determine information on the velocity space and poloidal distribution of the lost alpha particles for the first time. This extensive set of data provides unique information for fundamental physics studies and validation of the numerical models, which are key to inform the physics and scenarios of ITER.

14.
Phys Rev Lett ; 107(20): 205002, 2011 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-22181739

RESUMO

The spectral broadening of characteristic γ-ray emission peaks from the reaction (12)C((3)He,pγ)(14)N was measured in D((3)He) plasmas of the JET tokamak with ion cyclotron resonance heating tuned to the fundamental harmonic of (3)He. Intensities and detailed spectral shapes of γ-ray emission peaks were successfully reproduced using a physics model combining the kinetics of the reacting ions with a detailed description of the nuclear reaction differential cross sections for populating the L1-L8 (14)N excitation levels yielding the observed γ-ray emission. The results provide a paradigm, which leverages knowledge from areas of physics outside traditional plasma physics, for the development of nuclear radiation based methods for understanding and controlling fusion burning plasmas.

15.
Rev Sci Instrum ; 92(4): 043517, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243482

RESUMO

A novel compact spectrometer optimized for the measurement of hard x rays generated by runaway electrons is presented. The detector is designed to be installed in the fan-shaped collimator of the gamma-ray imager diagnostic at the DIII-D tokamak. The spectrometer is based on a 1 × 1 cm2 cerium doped yttrium aluminum perovskite scintillator crystal coupled with a silicon photomultiplier. The detector dynamic energy range is in excess of 10 MeV, with an energy resolution of ∼10% at 661.7 keV. The fast detector signal (≈70 ns full width at half maximum) allows for operation at counting rates in excess of 1 MCps. The gain stability of the system can be monitored in real time using a light-emitting diode embedded in the instrument. The detector is expected to be deployed in the forthcoming DIII-D runaway electron experimental campaign.

16.
Rev Sci Instrum ; 92(4): 043506, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243369

RESUMO

Stilbene crystal detectors are widely used as fast neutron measurement tools based on recoil proton detection, such as liquid scintillators. A compact stilbene crystal neutron spectrometer (CSCNS) has been installed at the Experimental Advanced Superconducting Tokamak (EAST) to obtain information on fuel ions produced in the plasma core because of its merits of good n/γ discrimination capability, high detection efficiency, and fast response. For the first time, CSCNS has been used for neutron emission spectroscopy measurements in EAST plasmas with neutral beam injection (NBI) heating. The CSCNS has the same horizontal line of sight as the time-of-flight enhanced diagnostics neutron spectrometer. Under NBI heating scenarios, the time trace of the neutron yield monitored by the CSCNS is similar to the one monitored by a standard 235U fission chamber. The experimental pulse height spectra are also similar to the simulated ones generated by folding the simulated neutron energy spectrum with the detector response functions. These results demonstrate the capability of the CSCNS for neutron diagnostics and the study of fast-ion physics in EAST.

17.
Rev Sci Instrum ; 92(4): 043537, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243441

RESUMO

A new tangential gamma-ray spectrometer has been developed for fast ion measurements in deuterium and deuterium-tritium plasmas of the Joint European Torus (JET). The instrument is based on a LaBr3 crystal with a photo-multiplier tube and replaces a pre-existing bismuth germanate detector, providing enhanced energy resolution and a counting rate capability in the MHz range. The line of sight is equipped with a LiH attenuator, which reduces the background due to 14 MeV neutron interactions with the crystal by more than two orders of magnitude and enables the observation of gamma-ray emission from confined α particles in JET deuterium-tritium plasmas. Thanks to its tangential line of sight, the detector can distinguish co- and counter-passing ions. The performance of the instrument is demonstrated through the results of recent JET fast ion experiments in deuterium plasmas.

18.
Rev Sci Instrum ; 92(4): 043552, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243473

RESUMO

Neutron emission spectroscopy and neutron yield measurements are important for high neutral beam injection (NBI) power heating at the Experimental Advanced Superconducting Tokamak (EAST). The neutron yields mainly depend on the deposition from NBI to the deuterium plasmas in the EAST. We have recently used TRANSP with time dependent diagnostic results to simulate the transport process of 30 s long pulse deuterium plasma discharges in the EAST, obtaining the time dependent fast ion distribution, neutron emission spectrum, and total neutron emission rate. Combined with the time trace of the result measured by a standard 235U fission chamber, the effects of different configurations of NBI heating in EAST fusion plasmas have been evaluated.

19.
Pulmonology ; 2021 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-33879426

RESUMO

The design of e-cigarettes (e-cigs) is constantly evolving and the latest models can aerosolize using high-power sub-ohm resistance and hence may produce specific particle concentrations. The aim of this study was to evaluate the aerosol characteristics generated by two different types of electronic cigarette in real-world conditions, such as a sitting room or a small office, in number of particles (particles/cm3). We compared the real time and time-integrated measurements of the aerosol generated by the e-cigarette types Just Fog and JUUL. Real time (10s average) number of particles (particles/cm3) in 8 different aerodynamic sizes was measured using an optical particle counter (OPC) model Profiler 212-2. Tests were conducted with and without a Heating, Ventilating Air Conditioning System (HVACS) in operation, in order to evaluate the efficiency of air filtration. During the vaping sessions the OPC recorded quite significant increases in number of particles/cm3. The JUUL e-cig produced significantly lower emissions than Just Fog with and without the HVACS in operation. The study demonstrates the rapid volatility or change from liquid or semi-liquid to gaseous status of the e-cig aerosols, with half-life in the order of a few seconds (min. 4.6, max 23.9), even without the HVACS in operation. The e-cig aerosol generated by the JUUL proved significantly lower than that generated by the Just Fog, but this reduction may not be sufficient to eliminate or consistently reduce the health risk for vulnerable non e-cig users exposed to it.

20.
Rev Sci Instrum ; 92(5): 053529, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243238

RESUMO

The Joint European Torus (JET) gamma-ray camera has been recently upgraded with the installation of new gamma-ray detectors, based on LaBr3(Ce) scintillation crystals, which add spectroscopic capability to the existing system allowing measurements with good energy resolution (5% at 0.622 MeV), a dynamic range from hundreds of keV up to about 30 MeV, and high counting rate capabilities of MCps. First gamma-ray measurements during the C38 campaign of the JET have been successfully carried out, in particular, in D-3He plasmas from three-ion ion cyclotron resonance heating experiments, where the detection of 16.4 MeV γ-rays from D + 3He → γ + 5Li reactions with the gamma-ray camera upgrade allowed determining the spatial profile of alpha particles born in D + 3He fusion reactions.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa