Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Zhonghua Bing Li Xue Za Zhi ; 32(2): 124-7, 2003 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-12839673

RESUMO

OBJECTIVE: To analyze the loss of heterozygosity (LOH) at 5 loci on chromosome 3p in soft tissue leiomyosarcoma (LMS). METHODS: LOH was detected in 22 cases of LMS using PCR-silver staining targeting 5 microsatellite sites on 3p14.2-pter. Relation between LOH and LMS clinical pathological features was also analyzed. RESULTS: Ten of 22 LMS samples showed LOH at more than one locus (45.4%). Among the 5 loci, LOH occurred more frequently at D3s1295 (36.8%) and D3s1289 (10.5%), but absent at D3s1293. No significant difference was found on LOH incidence between different grade, size and location of LMS. CONCLUSIONS: LOH on chromosome 3p14.2-23 region is relatively frequent in LMS. Region around D3s1295 and D3s1289 may harbor tumor suppressor gene relating to LMS.


Assuntos
Cromossomos Humanos Par 3 , Leiomiossarcoma/genética , Perda de Heterozigosidade , Repetições de Microssatélites , Neoplasias de Tecidos Moles/genética , Neoplasias Abdominais/genética , Neoplasias Abdominais/patologia , Extremidades , Genes Supressores de Tumor , Humanos , Leiomiossarcoma/patologia , Neoplasias Retroperitoneais/genética , Neoplasias Retroperitoneais/patologia , Neoplasias de Tecidos Moles/patologia
2.
Chin Med J (Engl) ; 125(19): 3393-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23044294

RESUMO

BACKGROUND: Since permanent polymer is implicated in adverse events associated with delayed vessel healing after drug eluting stents (DES) implantation, great efforts have been made to develop more biocompatible DES with biodegradable polymer or without polymer. The present study aimed to evaluate the safety and efficacy of polymer free paclitaxel-eluting stents (PF-PES) in comparison with permanent polymer sirolimus-eluting stents (PP-SES) in patients with acute ST-segment elevation myocardial infarction (STEMI). METHODS: Patients with STEMI were randomly assigned to receive PP-SES (n = 55), and PF-PES (n = 50). The 6-month angiographic and 1-year clinical outcomes were compared between the two groups. Target lesion failure (TLF) was defined as the composite of cardiac death, recurrent nonfatal myocardial infarction (Re-MI), or target lesion revascularization (TLR). RESULTS: Follow-up angiography at six months was performed in 72.7% of the PP-SES group and 70.0% of the PF-PES group (P = 0.757). The two groups had comparable angiographic outcomes including minimal luminal diameter, diameter stenosis, late loss and binary restenosis. All patients were clinically followed up to one year. The two groups had similar clinical outcomes with relatively low rates of target lesion failure (10.9% PP-SES vs. 12.0% PF-PES, P = 0.861) and definite or probable stent thrombosis (1.8% PP-SES vs. 2.0% PF-PES, P = 1.000) at one year. CONCLUSIONS: The present study suggests that the safety and efficacy of PF-PES in the setting of STEMI are comparable to PP-SES. Further randomized trials with larger study populations are needed to get definite conclusions.


Assuntos
Angioplastia Coronária com Balão/métodos , Stents Farmacológicos/efeitos adversos , Imunossupressores/uso terapêutico , Infarto do Miocárdio/terapia , Paclitaxel/uso terapêutico , Polímeros/efeitos adversos , Sirolimo/uso terapêutico , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Feminino , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa