Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Molecules ; 25(20)2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33066091

RESUMO

The goal of this work was to develop a shape memory polymer (SMP) foam with visibility under both X-ray and magnetic resonance imaging (MRI) modalities. A porous polymeric material with these properties is desirable in medical device development for applications requiring thermoresponsive tissue scaffolds with clinical imaging capabilities. Dual modality visibility was achieved by chemically incorporating monomers with X-ray visible iodine-motifs and MRI visible monomers with gadolinium content. Physical and thermomechanical characterization showed the effect of increased gadopentetic acid (GPA) on shape memory behavior. Multiple compositions showed brightening effects in pilot, T1-weighted MR imaging. There was a correlation between the polymeric density and X-ray visibility on expanded and compressed SMP foams. Additionally, extractions and indirect cytocompatibility studies were performed to address toxicity concerns of gadolinium-based contrast agents (GBCAs). This material platform has the potential to be used in a variety of medical devices.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Materiais Inteligentes/química , Células 3T3 , Animais , Meios de Contraste/toxicidade , Gadolínio/química , Camundongos , Microscopia Eletrônica de Varredura , Porosidade , Espectroscopia de Infravermelho com Transformada de Fourier , Resistência à Tração , Temperatura de Transição , Raios X
2.
J Mater Chem B ; 12(15): 3694-3702, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38529581

RESUMO

Thermoresponsive shape memory polymers (SMPs) prepared from UV-curable poly(ε-caprolactone) (PCL) macromers have the potential to create self-fitting bone scaffolds, self-expanding vaginal stents, and other shape-shifting devices. To ensure tissue safety during deployment, the shape actuation temperature (i.e., the melt transition temperature or Tm of PCL) must be reduced from ∼55 °C that is observed for scaffolds prepared from linear-PCL-DA (Mn ∼ 10 kg mol-1). Moreover, increasing the rate of biodegradation would be advantageous, facilitating bone tissue healing and potentially eliminating the need for stent retrieval. Herein, a series of six UV-curable PCL macromers were prepared with linear or 4-arm star architectures and with Mns of 10, 7.5, and 5 kg mol-1, and subsequently fabricated into six porous scaffold compositions (10k, 7.5k, 5k, 10k★, 7.5k★, and 5k★) via solvent casting particulate leaching (SCPL). Scaffolds produced from star-PCL-tetraacrylate (star-PCL-TA) macromers produced pronounced reductions in Tm with decreased Mnversus those formed with the corresponding linear-PCL-diacrylate (linear-PCL-DA) macromers. Scaffolds were produced with the desired reduced Tm profiles: 37 °C < Tm < 55 °C (self-fitting bone scaffold), and Tm ≤ 37 °C (self-expanding stent). As macromer Mn decreased, crosslink density increased while % crystallinity decreased, particularly for scaffolds prepared from star-PCL-TA macromers. While shape memory behavior was retained and radial expansion pressure increased, this imparted a reduction in modulus but with an increase in the rate of degradation.


Assuntos
Poliésteres , Alicerces Teciduais , Temperatura de Transição , Osso e Ossos , Temperatura
3.
ACS Appl Bio Mater ; 5(6): 2633-2642, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35658422

RESUMO

First metatarsophalangeal joint (MPJ) arthroplasty procedures are a common podiatric procedure. However, almost one-third of cases require revision surgeries because of nonunions. Revision or salvage surgery requires more extensive hardware and bone grafts to recreate the first metatarsal. Unfortunately, salvage surgeries have a similar rate of failure attributed to delayed healing, bone graft dissolution, and the lack of bone ingrowth. Furthermore, patients who suffer from neuropathic comorbidities such as diabetes suffer from a diminished healing capacity. An increase in proinflammatory factors and the high presence of reactive oxygen species (ROS) present in diabetics are linked to lower fusion rates. To this end, there is a need for a clinically relevant bone graft to promote bone fusions in patients with neuropathic comorbidities. Incorporating thiol-ene networks for bone scaffolds has demonstrated increased osteogenic biomarkers over traditional polymeric materials. Furthermore, thiol-ene networks can act as antioxidants. Sulfide linkages within the network have an inherent ability to consume radical oxygen to create sulfoxide and sulfone groups. These unique properties of thiol-ene networks make them a promising candidate as bone grafts for diabetic patients. In this work, we propose a thiol-ene biomaterial to address the current limitations of MPJ fusion in diabetics by characterizing mechanical properties, degradation rates under accelerated conditions, and oxidative responsiveness under pathophysiologic conditions. We also demonstrated that thiol-ene-based materials could reduce the number of hydroxyl radicals associated with neuropathic comorbidities.


Assuntos
Polímeros , Compostos de Sulfidrila , Humanos , Teste de Materiais
4.
J Colloid Interface Sci ; 625: 237-247, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35716618

RESUMO

INTRODUCTION: Measuring in vivo degradation for polymeric scaffolds is critical for analysis of biocompatibility. Traditionally, histology has been used to estimate mass loss in scaffolds, allowing for simultaneous evaluation of mass loss and the biologic response to the implant. Oxidatively degradable shape memory polyurethane (SMP) foams have been implemented in two vascular occlusion devices: peripheral embolization device (PED) and neurovascular embolization device (NED). This work explores the errors introduced when using histological sections to evaluate mass loss. METHODS: Models of the SMP foams were created to mimic the device geometry and the tetrakaidekahedral structure of the foam pore. These models were degraded in Blender for a wide range of possible degradation amounts and the mass loss was estimated using m sections. RESULTS: As the number of sections (m) used to estimate mass loss for a volume increased the sampling error decreased and beyond m = 5, the decrease in error was insignificant. NED population and sampling errors were higher than for PED scenarios. When m ≥ 5, the averaged sampling error was below 1.5% for NED and 1% for PED scenarios. DISCUSSION/CONCLUSION: This study establishes a baseline sampling error for estimating randomly degraded porous scaffolds using a sectional method. Device geometry and the stage of mass loss influence the sampling error. Future studies will use non-random degradation to further investigate in vivo mass loss scenarios.


Assuntos
Polímeros , Poliuretanos , Porosidade
5.
Polymers (Basel) ; 14(19)2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36236069

RESUMO

Shape-memory polymer (SMP) polyurethane foams have been applied as embolic devices and implanted in multiple animal models. These materials are oxidatively degradable and it is critical to quantify and characterize the degradation for biocompatibility assessments. An image-based method using high-resolution and magnification scans of histology sections was used to estimate the mass loss of the peripheral and neurovascular embolization devices (PED, NED). Detailed analysis of foam microarchitecture (i.e., struts and membranes) was used to estimate total relative mass loss over time. PED foams implanted in porcine arteries showed a degradation rate of ~0.11% per day as evaluated at 30-, 60-, and 90-day explant timepoints. NED foams implanted in rabbit carotid elastase aneurysms showed a markedly faster rate of degradation at ~1.01% per day, with a clear difference in overall degradation between 30- and 90-day explants. Overall, membranes degraded faster than the struts. NEDs use more hydrophobic foam with a smaller pore size (~150-400 µm) compared to PED foams (~800-1200 µm). Previous in vitro studies indicated differences in the degradation of the two polymer systems, but not to the magnitude seen in vivo. Implant location, animal species, and local tissue health are among the hypothesized reasons for different degradation rates.

6.
J Mater Chem B ; 9(18): 3826-3837, 2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33979417

RESUMO

"Self-fitting" shape memory polymer (SMP) scaffolds prepared as semi-interpenetrating networks (semi-IPNs) with crosslinked linear-poly(ε-caprolactone)-diacrylate (PCL-DA, Mn∼10 kg mol-1) and linear-poly(l-lactic acid) (PLLA, Mn∼15 kg mol-1) [75/25 wt%] exhibited robust mechanical properties and accelerated degradation rates versus a PCL-DA scaffold control. However, their potential to treat irregular craniomaxillofacial (CMF) bone defects is limited by their relatively high fitting temperature (Tfit∼55 °C; related to the Tm of PCL) required for shape recovery (i.e. expansion) and subsequent shape fixation during press fitting of the scaffold, which can be harmful to surrounding tissue. Additionally, the viscosity of the solvent-based precursor solutions, cast over a fused salt template during fabrication, can limit scaffold size. Thus, in this work, analogous semi-IPN SMP scaffolds were formed with a 4-arm star-PCL-tetracryalate (star-PCL-TA) (Mn∼10 kg mol-1) and star-PLLA (Mn∼15 kg mol-1). To assess the impact of a star-polymer architecture, four semi-IPN compositions were prepared: linear-PCL-DA/linear-PLLA (L/L), linear-PCL-DA/star-PLLA (L/S), star-PCL-TA/linear-PLLA (S/L) and star-PCL-TA/star-PLLA (S/S). Two PCL controls were also prepared: LPCL (i.e. 100% linear-PCL-DA) and SPCL (i.e. 100% star-PCL-TA). The S/S semi-IPN scaffold exhibited particularly desirable properties. In addition to achieving a lower, tissue-safe Tfit (∼45 °C), it exhibited the fastest rate of degradation which is anticipated to more favourably permit neotissue infiltration. The radial expansion pressure exerted by the S/S semi-IPN scaffold at Tfit was greater than that of LPCL, which is expected to enhance osseointegration and mechanical stability. The intrinsic viscosity of the S/S semi-IPN macromer solution was also reduced such that larger scaffold specimens could be prepared.


Assuntos
Materiais Inteligentes/química , Animais , Doenças Ósseas/terapia , Força Compressiva , Modelos Animais de Doenças , Poliésteres/química , Porosidade , Ratos , Materiais Inteligentes/metabolismo , Materiais Inteligentes/uso terapêutico , Viscosidade
7.
ACS Biomater Sci Eng ; 6(5): 2588-2599, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32715083

RESUMO

The IMPEDE Embolization Plug is a catheter-delivered vascular occlusion device that utilizes a porous shape memory polymer foam as a scaffold for thrombus formation and distal coils to anchor the device within the vessel. In this study, we investigated the biological response of porcine arteries to the IMPEDE device by assessing the extent of healing and overall effectiveness in occluding the vessel at 30, 60, and 90 days. Compared to control devices (Amplatzer Vascular Plug and Nester Embolization Coils), the host response to IMPEDE showed increased cellular infiltration (accommodated by the foam scaffold), which led to advanced healing of the initial thrombus to mature collagenous connective tissue (confirmed by transmission electron microscopy (TEM)). Over time, the host response to the IMPEDE device included degradation of the foam by multinucleated giant cells, which promoted fibrin and polymer degradation and advanced the healing response. Device effectiveness, in terms of vessel occlusion, was evaluated histologically by assessing the degree of recanalization. Although instances of recanalization were often observed at all time points for both control and test articles, the mature connective tissue within the foam scaffold of the IMPEDE devices improved percent vessel occlusion; when recanalization was observed in IMPEDE-treated vessels, channels were exclusively peri-device rather than intradevice, as often observed in the controls, and the vessels mostly remained >75% occluded. Although total vessel occlusion provides the optimal ischemic effect, in cardiovascular pathology, there is a progressive ischemic effect on the downstream vasculature as a vessel narrows. As such, we expect a sustained ischemic therapeutic effect to be observed in vessels greater than 75% occluded. Overall, the current study suggests the IMPEDE device presents advantages over controls by promoting an enhanced degree of healing within the foam scaffold, which decreases the likelihood of intradevice recanalization and ultimately may lead to a sustained ischemic therapeutic effect.


Assuntos
Embolização Terapêutica , Materiais Inteligentes , Doenças Vasculares , Animais , Prótese Vascular , Polímeros , Suínos
8.
J Biomed Mater Res B Appl Biomater ; 107(8): 2466-2475, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30775843

RESUMO

Shape memory polymer (SMP) foam-coated coils (FCCs) are new embolic coils coated with porous SMP designed to expand for increased volume filling and enhanced healing after implantation. The purpose of this study was to compare chronic aneurysm healing after treatment with SMP FCCs to bare platinum coil (BPC) controls in the rabbit elastase aneurysm model. BPCs or SMP FCCs were implanted in rabbit elastase-induced aneurysms for follow-up at 30 days (n = 10), 90 days (n = 5), and 180 days (n = 12 for BPCs; n = 14 for SMP FCCs). Aneurysm occlusion and histologic healing, including a qualitative healing score, neointima thickness, collagen deposition, and inflammation were compared between the two groups. The mean neointima thickness was significantly greater in groups treated with SMP FCCs for all three time points. Histologic healing scores and collagen deposition quantification suggested that aneurysms treated with SMP FCCs experience more complete healing of the dome by 90 days, but the differences were not statistically significant. More progressive occlusion and recanalization were observed in aneurysms treated with SMP FCCs, but neither difference was statistically significant. Additionally, the SMP foam used in the FCCs was found to degrade faster in the rabbit elastase model than expected based on previous studies in a porcine sidewall aneurysm model. This study suggests that SMP FCCs can promote neointima formation along the aneurysm neck, and may lead to more complete healing of the dome and neck. These findings indicate potential benefits of this device for aneurysm occlusion procedures. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B:2466-2475, 2019.


Assuntos
Aneurisma , Materiais Revestidos Biocompatíveis , Embolização Terapêutica/instrumentação , Elastase Pancreática/toxicidade , Materiais Inteligentes , Aneurisma/induzido quimicamente , Aneurisma/fisiopatologia , Aneurisma/terapia , Animais , Coelhos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa