Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Drug Test Anal ; 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38234065

RESUMO

Methandienone is an anabolic-androgenic steroid that is prohibited in equine sports due to its potential performance enhancing properties. Metabolism and detection of methandienone in equine urine have been investigated comprehensively in literature; however, there is a limited knowledge about its metabolites in equine plasma and no information about its detection in equine hair. Following a multi-dose oral administration of methandienone to two Thoroughbred horses, 17-epimethandienone, methyltestosterone, two mono-hydroxylated, two di-hydroxylated and three 17α-methylandrostanetriol metabolites were detected in plasma. The majority of these were present as free analytes, whilst the mono-hydroxylated metabolites and one isomer of 17α-methylandrostanetriol were partially conjugated. Estimated peak concentrations of methandienone were 6,000 and 11,100 pg/ml; meanwhile, they were 25.4 and 40.5 pg/ml for methyltestosterone. The most abundant analyte in the post-administration plasma samples of both horses was the mono-hydroxylated metabolite; however, the parent compound provided the longest detection (up to 96 h). Screening analysis of hair enabled the detection of methandienone in mane hair samples only, for up to 3 months. Its mono- and di-hydroxylated metabolites were detected with greater peak responses for up to 6 months post-administration in both mane and tail samples, showing that these metabolites could be better analytical targets for hair analysis when administered orally. A follow-up methodology with an extensive wash procedure confirmed the presence of methandienone and its metabolites in a number of post-administration hair samples. Final wash samples were also analysed to assess the degree of internal incorporation (via bloodstream) against possible external deposition (via sweat/sebum).

2.
Drug Test Anal ; 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38217093

RESUMO

FG-4592 is a hypoxia-inducible factor inhibitor that has been approved for therapeutic use in some countries. This class of compounds can increase the oxygen carrying capacity of the blood and thus have the potential to be used as performance enhancing agents in sports. The purpose of this study was to investigate the detection of FG-4592 and metabolites in equine plasma and mane hair following a multiple dose oral administration to two Thoroughbred racehorses, to identify the best analytical targets for doping control laboratories. Urine samples were also analysed, and the results compared to previously published urine data. Liquid chromatography-high resolution mass spectrometry was used for metabolite identification in urine and plasma. Liquid chromatography-tandem mass spectrometry was used for full sample analysis of urine, plasma and hair samples and generation of urine and plasma profiles. FG-4592 and a mono-hydroxylated metabolite were detected in plasma. FG-4592 was detected with the greatest abundance and gave the longest duration of detection, up to 312 h post-administration, and would be the recommended target in routine doping samples. FG-4592 was detected in all mane hair samples collected post-administration, up to 166 days following the final dose, showing extended detection can be achieved with this matrix. To the best of the authors' knowledge, this is the first report of FG-4592 and metabolites in equine plasma and hair samples. Urine results were consistent with the previously published data, with FG-4592 offering the best target for detection and longest detection periods.

3.
Drug Test Anal ; 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38092431

RESUMO

Detection of doping with steroids that are also endogenous in the horse can be challenging, and a variety of approaches to distinguish exogenous administration from their natural presence are employed. Knowledge of endogenous concentrations of various steroids in different genders of horses (intact male, castrated male and female) and factors that could naturally affect them is beneficial for establishing ways for detection of their use. The current internationally adopted approaches include concentration-based thresholds in urine and plasma, steroid ratios in urine and targeting the administered intact steroid esters in plasma and hair. However, these have their limitations, and therefore, other strategies, such as additional biomarkers and steroid profiling based on longitudinal testing and multivariate analysis, have been investigated and could potentially improve detection of the use of endogenous steroids in horses. This paper aims to provide a comprehensive overview of the steroids (androgens, oestrogens and progestogens) that have been reported to be endogenous to horses in literature, their concentration ranges in different genders and factors potentially affecting them as well as current and possible future approaches to detect their use.

4.
Drug Test Anal ; 13(3): 583-594, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33169539

RESUMO

Etizolam is a benzodiazepine analogue that is approved for use in Japan, Italy and India but has recently appeared as a nonapproved product on the illicit drug market in Europe and North America. Etizolam was identified in a crystalline material seized at a Kentucky racetrack, raising concerns that this drug may have been used in racing. The aim of this study was to characterize the metabolism and excretion of etizolam in horses to generate information on its disposition and to incorporate the correct urinary and serum target analytes into anti-doping screening procedures. Etizolam was administered both intravenous and orally at a dose of 0.1 mg/kg of body weight to three horses using a two-way crossover design. Pre-administration and post-administration serum and urine samples were collected and experiments conducted to identify potential metabolites in these samples. Additionally, in vitro metabolism studies using horse liver S9 were undertaken to complement the in vivo metabolism studies. Numerous metabolites were id1entified in both serum and urine in additional to parent drug, with α-hydroxy-etizolam producing the most abundant analytical signal (in terms of signal intensity and duration of detection) of the identified metabolites in both matrices. Therefore, α-hydroxy-etizolam is considered to be the most appropriate analyte for detection for anti-doping purposes. Analytical methods were developed and validated and then applied to post-administration samples to generate concentrations of etizolam and its major metabolites in serum and urine, resulting in excretion profiles that can be used to guide approaches to detecting the use of the drug.


Assuntos
Diazepam/análogos & derivados , Dopagem Esportivo/prevenção & controle , Detecção do Abuso de Substâncias/métodos , Administração Intravenosa , Administração Oral , Animais , Estudos Cross-Over , Diazepam/administração & dosagem , Diazepam/análise , Diazepam/farmacocinética , Cavalos , Fígado/metabolismo
5.
Drug Test Anal ; 5(5): 306-14, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22514113

RESUMO

Fluticasone propionate (FP) is an anti-inflammatory agent with topical and inhaled applications commonly used in the treatment of asthma in steroid-dependent individuals. The drug is used in racehorses to treat Inflammatory Airway Disease; this work was performed in order to advise on its use and detect potential misuse close to racing. Methods were developed for the extraction and analysis of FP from horse plasma and a carboxylic acid metabolite (FP-17ßCOOH) from horse urine. The methods utilize ultra high performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) in order to detect the extremely low concentrations of analyte present in both matrices. The developed methods were used to analyse plasma and urine samples collected following inhaled administration of FP to six thoroughbred horses. FP was detected in plasma for a minimum of 72 h post-administration and FP-17ßCOOH was detected in urine for approximately 18 h post-administration. The results show that it is possible to detect FP in the horse following inhaled administration.


Assuntos
Androstadienos/sangue , Androstadienos/urina , Anti-Inflamatórios/sangue , Anti-Inflamatórios/urina , Cavalos/sangue , Cavalos/urina , Administração por Inalação , Androstadienos/administração & dosagem , Androstadienos/metabolismo , Animais , Anti-Inflamatórios/administração & dosagem , Anti-Inflamatórios/metabolismo , Cromatografia Líquida de Alta Pressão , Fluticasona , Espectrometria de Massas em Tandem
6.
Anal Chim Acta ; 787: 163-72, 2013 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-23830435

RESUMO

The detection of the abuse of anabolic steroids in equine sport is complicated by the endogenous nature of some of the abused steroids, such as testosterone and nandrolone. These steroids are commonly administered as intramuscular injections of esterified forms of the steroid, which prolongs their effects and improves bioavailability over oral dosing. The successful detection of an intact anabolic steroid ester therefore provides unequivocal proof of an illegal administration, as esterified forms are not found endogenously. Detection of intact anabolic steroid esters is possible in plasma samples but not, to date, in the traditional doping control matrix of urine. The analysis of equine mane hair for the detection of anabolic steroid esters has the potential to greatly extend the time period over which detection of abuse can be monitored. Equine mane hair samples were incubated in 0.1M phosphate buffer (pH 9.5) before anabolic steroids (testosterone, nandrolone, boldenone, trenbolone and stanozolol), anabolic steroid esters (esters of testosterone, nandrolone, boldenone and trenbolone) and associated compounds (fluticasone propionate and esters of hydroxyprogesterone) were extracted by liquid-liquid extraction with a mix of hexane and ethyl acetate (7:3, v:v). Further sample clean up by solid phase extraction was followed by derivatisation with methoxylamine HCL and analysis by UHPLC-MS/MS. Initial method development was performed on a representative suite of four testosterone esters (propionate, phenylpropionate, isocaproate and decanoate) and the method was later extended to include a further 18 compounds. The applicability of the method was demonstrated by the analysis of mane hair samples collected following the intramuscular administration of 500 mg of Durateston(®) (mixed testosterone esters) to a Thoroughbred mare (560 kg). The method was subsequently used to successfully detect boldenone undecylenate and stanozolol in hair samples collected following suspicious screening findings from post-race urine samples. The use of segmental analysis to potentially provide additional information on the timing of administration was also investigated.


Assuntos
Anabolizantes/análise , Dopagem Esportivo , Cabelo/química , Espectrometria de Massas em Tandem/métodos , Testosterona/análise , Animais , Cromatografia Líquida de Alta Pressão/métodos , Ésteres , Estudos de Viabilidade , Feminino , Cavalos , Masculino , Esteroides/análise
7.
Drug Test Anal ; 3(4): 206-13, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21287693

RESUMO

Analysis of equine plasma samples to detect the abuse of anabolic steroids can be complicated when the parent steroid is endogenous to the animal. Anabolic steroids are usually administered intramuscularly as synthetic esters and therefore detection of the exogenous esters provides unequivocal proof of illegal administration. An ultra high performance liquid chromatography tandem mass spectrometric (UPLC-MSMS) method for the analysis of esters of testosterone (propionate, phenylpropionate, isocaproate, and decanoate) and boldenone (undecylenate) in equine plasma has been developed. Esters were extracted from equine plasma using a mixture of hexane and ethyl acetate and treated with methoxyamine hydrochloride to form methyloxime derivatives. Metenolone enanthate was used as an internal standard. After chromatographic separation, the derivatized steroid esters were quantified using selected reaction monitoring (SRM). The limit of detection for all of the steroid esters, based on a signal to noise ratio (S/N) of 3:1, was 1-3 pg/mL. The lower limit of quantification (LLOQ) for the all of the steroid esters was 5 pg/mL when 2 mL of plasma was extracted. Recovery of the steroid esters was 85-97% for all esters except for testosterone decanoate which was recovered at 62%. The intra-day coefficient of variation (CV) for the analysis of plasma quality control (QC) samples was less than 9.2% at 40 pg/mL and less than 6.0% at 400 pg/mL. The developed assay was used to successfully confirm the presence of intact testosterone esters in equine plasma samples following intramuscular injection of Durateston® (mixed testosterone esters).


Assuntos
Cavalos/sangue , Oximas/sangue , Espectrometria de Massas em Tandem/normas , Testosterona/análogos & derivados , Testosterona/sangue , Anabolizantes/administração & dosagem , Anabolizantes/sangue , Animais , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Dopagem Esportivo/prevenção & controle , Ésteres , Injeções Intramusculares , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Testosterona/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa