Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Circulation ; 104(12 Suppl 1): I330-5, 2001 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-11568078

RESUMO

BACKGROUND: Early diastolic intraventricular pressure gradients (IVPGs) have been proposed to relate to left ventricular (LV) elastic recoil and early ventricular "suction." Animal studies have demonstrated relationships between IVPGs and systolic and diastolic indices during acute ischemia. However, data on the effects of improvements in LV function in humans and the relationship to IVPGs are lacking. METHODS AND RESULTS: Eight patients undergoing CABG and/or infarct exclusion surgery had a triple-sensor high-fidelity catheter placed across the mitral valve intraoperatively for simultaneous recording of left atrial (LA), basal LV, and apical LV pressures. Hemodynamic data obtained before bypass were compared with those with similar LA pressures and heart rates obtained after bypass. From each LV waveform, the time constant of LV relaxation (tau), +dP/dt(max), and -dP/dt(max) were determined. Transesophageal echocardiography was used to determined end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fractions (EF). At similar LA pressures and heart rates, IVPG increased after bypass (before bypass 1.64+/-0.79 mm Hg; after bypass 2.67+/-1.25 mm Hg; P<0.01). Significant improvements were observed in ESV, as well as in apical and basal +dP/dt(max), -dP/dt(max), and tau (each P<0.05). Overall, IVPGs correlated inversely with both ESV (IVPG=-0.027[ESV]+3.46, r=-0.64) and EDV (IVPG=-0.027[EDV]+4.30, r=-0.70). Improvements in IVPGs correlated with improvements in apical tau (Deltatau =5.93[DeltaIVPG]+4.76, r=0.91) and basal tau (Deltatau =2.41[DeltaIVPG]+5.13, r=-0.67). Relative changes in IVPGs correlated with changes in ESV (DeltaESV=-0.97[%DeltaIVPG]+23.34, r=-0.79), EDV (DeltaEDV=-1.16[%DeltaIVPG]+34.92, r=-0.84), and EF (DeltaEF=0.38[%DeltaIVPG]-8.39, r=0.85). CONCLUSIONS: Improvements in LV function also increase IVPGs. These changes in IVPGs, suggestive of increases in LV suction and elastic recoil, correlate directly with improvements in LV relaxation and ESV.


Assuntos
Pressão Sanguínea , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Diástole , Elasticidade , Técnicas Eletrofisiológicas Cardíacas , Feminino , Testes de Função Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Sístole , Resultado do Tratamento
2.
Circulation ; 102(19 Suppl 3): III101-6, 2000 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-11082371

RESUMO

BACKGROUND: Infarct exclusion (IE) surgery, a technique of left ventricular (LV) reconstruction for dyskinetic or akinetic LV segments in patients with ischemic cardiomyopathy, requires accurate volume quantification to determine the impact of surgery due to complicated geometric changes. METHODS AND RESULTS: Thirty patients who underwent IE (mean age 61+/-8 years, 73% men) had epicardial real-time 3-dimensional echocardiographic (RT3DE) studies performed before and after IE. RT3DE follow-up was performed transthoracically 42+/-67 days after surgery in 22 patients. Repeated measures ANOVA was used to compare the values before and after IE surgery and at follow-up. Significant decreases in LV end-diastolic (EDVI) and end-systolic (ESVI) volume indices were apparent immediately after IE and in follow-up (EDVI 99+/-40, 67+/-26, and 71+/-31 mL/m(2), respectively; ESVI 72+/-37, 40+/-21, and 42+/-22 mL/m(2), respectively; P:<0.05). LV ejection fraction increased significantly and remained higher (0.29+/-0.11, 0.43+/-0.13, and 0.42+/-0.09, respectively, P:<0.05). Forward stroke volume in 16 patients with preoperative mitral regurgitation significantly improved after IE and in follow-up (22+/-12, 53+/-24, and 58+/-21 mL, respectively, P:<0.005). New York Heart Association functional class at an average 285+/-144 days of clinical follow-up significantly improved from 3.0+/-0.8 to 1.8+/-0.8 (P:<0.0001). Smaller end-diastolic and end-systolic volumes measured with RT3DE immediately after IE were closely related to improvement in New York Heart Association functional class at clinical follow-up (Spearman's rho=0.58 and 0.60, respectively). CONCLUSIONS: RT3DE can be used to quantitatively assess changes in LV volume and function after complicated LV reconstruction. Decreased LV volume and increased ejection fraction imply a reduction in LV wall stress after IE surgery and are predictive of symptomatic improvement.


Assuntos
Cardiomiopatias/cirurgia , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Isquemia Miocárdica/cirurgia , Função Ventricular Esquerda , Volume Cardíaco , Cardiomiopatias/complicações , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Isquemia Miocárdica/complicações , Volume Sistólico , Taxa de Sobrevida , Resultado do Tratamento
3.
J Am Coll Cardiol ; 27(3): 706-13, 1996 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-8606286

RESUMO

OBJECTIVES: This study sought to elevate the effect of proximal flow constraint induced by the left ventricular wall on the accuracy of calculated flow rates and to assess a possible correction factor to adjust the proximal convergence angle. We further defined under which hydrodynamic and geometric conditions it is necessary to apply the corrected convergence angle. BACKGROUND: The proximal flow convergence method has been proposed as a new approach to quantify valvular regurgitation. However, significant overestimation of the calculated regurgitant flow rate has been reported, particularly in patients with mitral valve prolapse and severe mitral regurgitation. METHODS: We used an in vitro flow model and induced various degrees of proximal flow constraint. The accuracy of the proposed convergence angle formula, alpha = tau + 2 tan-1 d/r (d = wall distance; r = isovelocity radius) was tested in vitro and in a three-dimensional numerical simulation. RESULTS: With a constraining wall near the orifice, overstimulation of regurgitant flow rates was noted and was most significant with the constraining wall positioned closest to the orifice (calculated flow rate [Qc]/true flow rate [Qo] = 1.85 +/- 0.55 [mean +/- SD]). These findings were similar to the results of the numerical simulation. Applying the correction factor nearly completely eliminated the overestimation of the calculated flow rates (cQc), with cQc/Qo = 1.13 +/- 0.25. CONCLUSIONS: In the presence of a constraining wall, significant overestimation of calculated flow rates is observed when hemispheric symmetry of the flow field is assumed. In this situation, it is necessary to apply the corrected convergence angle formula to improve the accuracy of the proximal flow convergence method.


Assuntos
Ecocardiografia Doppler em Cores , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Viés , Velocidade do Fluxo Sanguíneo , Fatores de Confusão Epidemiológicos , Testes de Função Cardíaca , Humanos , Modelos Cardiovasculares , Análise Numérica Assistida por Computador , Reprodutibilidade dos Testes
4.
J Am Coll Cardiol ; 23(4): 943-50, 1994 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-8106700

RESUMO

OBJECTIVES: This clinical trial was performed to determine the safety and clinical impact of titrated metoprolol therapy in patients with heart failure, documented coronary artery disease and a low ejection fraction. BACKGROUND: Despite known cardiodepressant effects, long-term use of beta-adrenergic antagonists appears to be beneficial in patients with idiopathic dilated cardiomyopathy. However, this therapy has not been critically evaluated in patients with heart failure and coronary artery disease. METHODS: In 50 patients with heart failure, known coronary artery disease and an ejection fraction < or = 0.40, we examined the impact of metoprolol therapy in a 6-month double-blind, placebo-controlled randomized trial, assessing the frequency of heart failure exacerbations and changes in symptoms (New York Heart Association functional class), ejection fraction and exercise duration. Placebo-treated patients who completed 6-month follow-up studies then underwent a trial with metoprolol therapy (crossover group). RESULTS: Metoprolol was titrated to a mean maximal dose of 87 mg/day (range 25 to 100) without serious adverse reactions. During double-blind therapy, use of a beta-blocker was associated with a significant reduction in the number of hospital admissions (4% vs. 32%, p < 0.05), overall improved functional class (p = 0.02), increased ejection fraction (4 +/- 7% [mean +/- SD] compared with 0 +/- 6%, p < 0.05) and a greater increase in exercise duration (193 +/- 276 vs. 38 +/- 213 s with placebo, p < 0.01). Crossover outcome paralleled the favorable impact seen during randomized metoprolol therapy. CONCLUSIONS: Cautious use of titrated metoprolol appears to be safe and beneficial when added to standard heart failure therapy in patients with dilated cardiomyopathy associated with coronary artery disease.


Assuntos
Doença das Coronárias/complicações , Insuficiência Cardíaca/tratamento farmacológico , Metoprolol/uso terapêutico , Método Duplo-Cego , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Metoprolol/administração & dosagem , Pessoa de Meia-Idade , Resultado do Tratamento
5.
J Am Coll Cardiol ; 35(1): 201-8, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10636281

RESUMO

OBJECTIVES: To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND: The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS: We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS: In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS: Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.


Assuntos
Volume Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Diástole/fisiologia , Cães , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valores de Referência
6.
J Am Coll Cardiol ; 36(6): 1942-9, 2000 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-11092668

RESUMO

OBJECTIVES: We hypothesized that color M-mode (CMM) images could be used to solve the Euler equation, yielding regional pressure gradients along the scanline, which could then be integrated to yield the unsteady Bernoulli equation and estimate noninvasively both the convective and inertial components of the transmitral pressure difference. BACKGROUND: Pulsed and continuous wave Doppler velocity measurements are routinely used clinically to assess severity of stenotic and regurgitant valves. However, only the convective component of the pressure gradient is measured, thereby neglecting the contribution of inertial forces, which may be significant, particularly for nonstenotic valves. Color M-mode provides a spatiotemporal representation of flow across the mitral valve. METHODS: In eight patients undergoing coronary artery bypass grafting, high-fidelity left atrial and ventricular pressure measurements were obtained synchronously with transmitral CMM digital recordings. The instantaneous diastolic transmitral pressure difference was computed from the M-mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation and was compared to the catheter measurements. RESULTS: From 56 beats in 16 hemodynamic stages, inclusion of the inertial term ([deltapI]max = 1.78+/-1.30 mm Hg) in the noninvasive pressure difference calculation significantly increased the temporal correlation with catheter-based measurement (r = 0.35+/-0.24 vs. 0.81+/-0.15, p< 0.0001). It also allowed an accurate approximation of the peak pressure difference ([deltapc+I]max = 0.95 [delta(p)cathh]max + 0.24, r = 0.96, p<0.001, error = 0.08+/-0.54 mm Hg). CONCLUSIONS: Inertial forces are significant components of the maximal pressure drop across the normal mitral valve. These can be accurately estimated noninvasively using CMM recordings of transmitral flow, which should improve the understanding of diastolic filling and function of the heart.


Assuntos
Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiologia , Ultrassonografia Doppler em Cores , Função Ventricular Esquerda , Pressão Ventricular , Idoso , Feminino , Hemodinâmica , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Análise de Regressão
7.
J Am Coll Cardiol ; 30(5): 1288-94, 1997 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-9350929

RESUMO

OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Função Ventricular Esquerda , Adulto , Cardiomiopatia Dilatada/complicações , Vasos Coronários/fisiologia , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Insuficiência Cardíaca/etiologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Fluxo Sanguíneo Regional
8.
J Am Coll Cardiol ; 34(3): 795-801, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10483962

RESUMO

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.


Assuntos
Função do Átrio Esquerdo/fisiologia , Valva Mitral/fisiologia , Veias Pulmonares/fisiologia , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Ecocardiografia Doppler/métodos , Ecocardiografia Doppler/estatística & dados numéricos , Feminino , Hemodinâmica , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Modelos Cardiovasculares , Monitorização Intraoperatória/estatística & dados numéricos , Veias Pulmonares/diagnóstico por imagem , Sístole/fisiologia
9.
J Am Coll Cardiol ; 32(4): 1074-82, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9768735

RESUMO

OBJECTIVES: To develop and validate an automated noninvasive method to quantify mitral regurgitation. BACKGROUND: Automated cardiac output measurement (ACM), which integrates digital color Doppler velocities in space and in time, has been validated for the left ventricular (LV) outflow tract but has not been tested for the LV inflow tract or to assess mitral regurgitation (MR). METHODS: First, to validate ACM against a gold standard (ultrasonic flow meter), 8 dogs were studied at 40 different stages of cardiac output (CO). Second, to compare ACM to the LV outflow (ACMa) and inflow (ACMm) tracts, 50 normal volunteers without MR or aortic regurgitation (44+/-5 years, 31 male) were studied. Third, to compare ACM with the standard pulsed Doppler-two-dimensional echocardiographic (PD-2D) method for quantification of MR, 51 patients (61+/-14 years, 30 male) with MR were studied. RESULTS: In the canine studies, CO by ACM (1.32+/-0.3 liter/min, y) and flow meter (1.35+/-0.3 liter/min, x) showed good correlation (r=0.95, y=0.89x+0.11) and agreement (deltaCO(y-x)=0.03+/-0.08 [mean+/-SD] liter/min). In the normal subjects, CO measured by ACMm agreed with CO by ACMa (r=0.90, p < 0.0001, deltaCO=-0.09+/-0.42 liter/min), PD (r=0.87, p < 0.0001, deltaCO=0.12+/-0.49 liter/min) and 2D (r=0.84, p < 0.0001, deltaCO=-0.16+/-0.48 liter/min). In the patients, mitral regurgitant volume (MRV) by ACMm-ACMa agreed with PD-2D (r= 0.88, y=0.88x+6.6, p < 0.0001, deltaMRV=2.68+/-9.7 ml). CONCLUSIONS: We determined that ACM is a feasible new method for quantifying LV outflow and inflow volume to measure MRV and that ACM automatically performs calculations that are equivalent to more time-consuming Doppler and 2D measurements. Additionally, ACM should improve MR quantification in routine clinical practice.


Assuntos
Débito Cardíaco , Ecocardiografia Doppler em Cores , Insuficiência da Valva Mitral/diagnóstico , Adulto , Animais , Valva Aórtica/diagnóstico por imagem , Cães , Ecocardiografia Doppler de Pulso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes
10.
J Am Coll Cardiol ; 36(5): 1664-9, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11079674

RESUMO

OBJECTIVES: We sought to determine the relationship between different echocardiographic indices and pulmonary capillary wedge pressures (PCWP) in normal volunteers. BACKGROUND: Indices based on tissue Doppler (TDE) and color M-mode (CMM) echocardiography have been proposed to reflect left (LV) ventricular filling pressures. These include the ratio of early diastolic transmitral velocity (E) to early myocardial velocity measured by TDE (E') and the ratio of E to the wave propagation velocity (Vp) measured from CMM images. These indices, however, have not been validated in normal individuals. METHODS: We studied seven volunteers during two phases of preload altering maneuvers, baseline, with two stages of lower body negative pressure, and repeat baseline with two stages of volume loading. The PCWP obtained from right heart catheterization was compared with diastolic indices using pulsed Doppler, TDE and CMM echocardiography. RESULTS: The PCWP ranged from 2.2 to 23.5 mm Hg. During preload alterations, significant changes in E and septal E' (both p < 0.05) but not lateral E' or Vp were observed. Furthermore, E, septal E' and E/Vp correlated with PCWP (all r > 0.80) but not combined E and TDE indices (both r < 0.15). Within individuals, a similar linear relationship was observed among E/Vp, E and septal E' (average r > 0.80). CONCLUSIONS: In subjects without heart disease, E, septal E' and E/Vp correlate with PCWP. Because the influence of ventricular relaxation is minimized, the ratio E/Vp may be the best overall index of LV filling pressures.


Assuntos
Ecocardiografia , Pressão Propulsora Pulmonar/fisiologia , Adulto , Feminino , Humanos , Masculino , Valores de Referência
11.
J Am Coll Cardiol ; 36(3): 900-7, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10987618

RESUMO

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.


Assuntos
Sistemas Computacionais , Ecocardiografia Tridimensional , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/fisiopatologia , Volume Sistólico , Função Ventricular Esquerda , Animais , Feminino , Aneurisma Cardíaco/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Ovinos
12.
J Am Coll Cardiol ; 38(7): 1994-2000, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11738306

RESUMO

OBJECTIVES: This study was conducted to evaluate follow-up results in patients with hypertrophic obstructive cardiomyopathy (HOCM) who underwent either percutaneous transluminal septal myocardial ablation (PTSMA) or septal myectomy. BACKGROUND: Controversy exists with regard to these two forms of treatment for patients with HOCM. METHODS: Of 51 patients with HOCM treated, 25 were treated by PTSMA and 26 patients via myectomy. Two-dimensional echocardiograms were performed before both procedures, immediately afterwards and at a three-month follow-up. The New York Heart Association (NYHA) functional class was obtained before the procedures and at follow-up. RESULTS: Interventricular septal thickness was significantly reduced at follow-up in both groups (2.3 +/- 0.4 cm vs. 1.9 +/- 0.4 cm for septal ablation and 2.4 +/- 0.6 cm vs. 1.7 +/- 0.2 cm for myectomy, both p < 0.001). Estimated by continuous-wave Doppler, the resting pressure gradient (PG) across the left ventricular outflow tract (LVOT) significantly decreased immediately after the procedures in both groups (64 +/- 39 mm Hg vs. 28 +/- 29 mm Hg for PTSMA, 62 +/- 43 mm Hg vs. 7 +/- 7 mm Hg for myectomy, both p < 0.0001). At three-month follow-up, the resting PG remained lower in the PTSMA and myectomy groups (24 +/- 19 mm Hg and 11 +/- 6 mm Hg, respectively, vs. those before procedures, both p < 0.0001). The NYHA functional class was also significantly improved in both groups (3.5 +/- 0.5 vs. 1.9 +/- 0.7 for PTSMA, 3.3 +/- 0.5 vs. 1.5 +/- 0.7 for myectomy, both p < 0.0001). CONCLUSIONS: Both myectomy and PTSMA reduce LVOT obstruction and significantly improve NYHA functional class in patients with HOCM. However, there are benefits and drawbacks for each therapeutic method that must be counterbalanced when deciding on treatment for LVOT obstruction.


Assuntos
Cateterismo Cardíaco , Cardiomiopatia Hipertrófica/cirurgia , Septos Cardíacos/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Adulto , Idoso , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Septos Cardíacos/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/cirurgia
13.
J Am Coll Cardiol ; 38(4): 1195-202, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11583903

RESUMO

OBJECTIVES: We aimed to validate a new flow convergence (FC) method that eliminated the need to locate the regurgitant orifice and that could be performed semiautomatedly. BACKGROUND: Complex and time-consuming features of previously validated color Doppler methods for determining mitral regurgitant volume (MRV) have prevented their widespread clinical use. METHODS: Thirty-nine different hemodynamic conditions in 12 sheep with surgically created flail leaflets inducing chronic mitral regurgitation were studied with two-dimensional (2D) echocardiography. Color Doppler M-mode images along the centerline of the accelerating flow towards the mitral regurgitation orifice were obtained. The distance between the two first aliasing boundaries (interaliasing distance [IAD]) was measured and the FC radius was mathematically derived according to the continuity equation (R(calc) = IAD/(1 - radicalv(1)/v(2)), v(1) and v(2) being the aliasing velocities). The conventional 2D FC radius was also measured (R(meas)). Mitral regurgitant volume was then calculated according to the FC method using both R(calc) and R(meas). Aortic and mitral electromagnetic (EM) flow probes and meters were balanced against each other to determine the reference standard MRV. RESULTS: Mitral regurgitant volume calculated from R(calc) and R(meas) correlated well with EM-MRV (y = 0.83x + 5.17, r = 0.90 and y = 1.04x + 0.91, r = 0.91, respectively, p < 0.001 for both). However, both methods resulted in slight overestimation of EM-MRV (Delta was 3.3 +/- 2.1 ml for R(calc) and 1.3 +/- 2.3 ml for R(meas)). CONCLUSIONS: Good correlation was observed between MRV derived from R(calc) (IAD method) and EM-MRV, similar to that observed with R(meas) (conventional FC method) and EM-MRV. The R(calc) using the IAD method has an advantage over conventional R(meas) in that it does not require spatial localization of the regurgitant orifice and can be performed semiautomatedly.


Assuntos
Insuficiência da Valva Mitral/fisiopatologia , Modelos Animais , Ultrassonografia Doppler em Cores , Animais , Velocidade do Fluxo Sanguíneo , Insuficiência da Valva Mitral/diagnóstico por imagem , Modelos Cardiovasculares , Ovinos
14.
Am J Cardiol ; 84(9): 1068-73, 1999 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-10569665

RESUMO

The geometry of the left ventricle in patients with cardiomyopathy is often sub-optimal for 2-dimensional ultrasound when assessing left ventricular (LV) function and localized abnormalities such as a ventricular aneurysm. The aim of this study was to report the initial experience of real-time 3-D echocardiography for evaluating patients with cardiomyopathy. A total of 34 patients were evaluated with the real-time 3D method in the operating room (n = 15) and in the echocardiographic laboratory (n = 19). Thirteen of 28 patients with cardiomyopathy and 6 other subjects with normal LV function were evaluated by both real-time 3-D echocardiography and magnetic resonance imaging (MRI) for obtaining LV volumes and ejection fractions for comparison. There were close relations and agreements for LV volumes (r = 0.98, p <0.0001, mean difference = -15 +/- 81 ml) and ejection fractions (r = 0.97, p <0.0001, mean difference = 0.001 +/- 0.04) between the real-time 3D method and MRI when 3 cardiomyopathy cases with marked LV dilatation (LV end-diastolic volume >450 ml by MRI) were excluded. In these 3 patients, 3D echocardiography significantly underestimated the LV volumes due to difficulties with imaging the entire LV in a 60 degrees x 60 degrees pyramidal volume. The new real-time 3D echocardiography is feasible in patients with cardiomyopathy and may provide a faster and lower cost alternative to MRI for evaluating cardiac function in patients.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Isquemia Miocárdica/diagnóstico por imagem , Volume Cardíaco/fisiologia , Cardiomiopatia Dilatada/cirurgia , Estudos de Viabilidade , Coração Auxiliar , Humanos , Isquemia Miocárdica/cirurgia , Sensibilidade e Especificidade , Volume Sistólico/fisiologia , Ultrassonografia , Função Ventricular Esquerda/fisiologia
15.
Am J Cardiol ; 83(7): 1064-8, 1999 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-10190521

RESUMO

Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Adolescente , Adulto , Idoso , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Criança , Pré-Escolar , Fenômenos Eletromagnéticos , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ovinos
16.
J Appl Physiol (1985) ; 90(1): 299-307, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11133922

RESUMO

Myocardial tissue Doppler echocardiography (TDE) has been proposed as a tool for the assessment of diastolic function. Controversy exists regarding whether TDE measurements are influenced by preload. In this study, left ventricular volume and high-fidelity pressures were obtained in eight closed-chest dogs during intermittent caval occlusion. The time constant of isovolumic ventricular relaxation (tau) was altered with varying doses of dobutamine and esmolol. Peak early diastolic myocardial (E(m)) and transmitral (E) velocities were measured before and after preload reduction. The relative effects of changes in preload and relaxation were determined for E(m) and compared with their effects on E. The following results were observed: caval occlusion significantly decreased E (DeltaE = 16.4 +/- 3.3 cm/s, 36.6 +/- 13.7%, P < 0.01) and E(m) (DeltaE(m) = 1. 3 +/- 0.4 cm/s, 32.5 +/- 26.1%, P < 0.01) under baseline conditions. However, preload reduction was similar for E under all lusitropic conditions (P = not significant), but these effects on E(m) decreased with worsening relaxation. At tau < 50 ms, changes in E(m) with preload reduction were significantly greater (DeltaE(m) = 2.8 +/- 0.6 cm/s) than at tau = 50-65 ms (DeltaE(m) = 1.2 +/- 0.2 cm/s) and at tau >65 ms (DeltaE(m) = 0.5 +/- 0.1 cm/s, P < 0.05). We concluded that TDE E(m) is preload dependent. However, this effect decreases with worsening relaxation.


Assuntos
Circulação Coronária , Ecocardiografia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda , Animais , Velocidade do Fluxo Sanguíneo , Constrição Patológica , Diástole , Cães , Valva Mitral/fisiologia , Pressão , Veias Cavas/fisiopatologia , Função Ventricular
17.
J Am Soc Echocardiogr ; 13(7): 696-8, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10887358

RESUMO

Doppler echocardiography is commonly used in the assessment of stenotic valvular orifices. We describe the application of transesophageal echocardiography for the detection of a critical ostial left main coronary stenosis. Because preoperative coronary angiography often is not routinely performed in young patients undergoing valve surgery, application of Doppler echocardiography can potentially prevent catastrophic complications, particularly in atypical cases.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler de Pulso/métodos , Ecocardiografia Transesofagiana , Adulto , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Feminino , Humanos , Sensibilidade e Especificidade
18.
Med Phys ; 30(7): 1683-93, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12906185

RESUMO

In this investigation, we describe a quantitative technique to measure coronary motion, which can be correlated with cardiac image quality using multislice computed tomography (MSCT) scanners. MSCT scanners, with subsecond scanning, thin-slice imaging (sub-millimeter) and volume scanning capabilities have paved the way for new clinical applications like noninvasive cardiac imaging. ECG-gated spiral CT using MSCT scanners has made it possible to scan the entire heart in a single breath-hold. The continuous data acquisition makes it possible for multiple phases to be reconstructed from a cardiac cycle. We measure the position and three-dimensional velocities of well-known landmarks along the proximal, mid, and distal regions of the major coronary arteries [left main (LM), left anterior descending (LAD), right coronary artery (RCA), and left circumflex (LCX)] during the cardiac cycle. A dynamic model (called the "delay algorithm") is described which enables us to capture the same physiological phase or "state" of the anatomy during the cardiac cycle as the instantaneous heart rate varies during the spiral scan. The coronary arteries are reconstructed from data obtained during different physiological cardiac phases and we correlate image quality of different parts of the coronary anatomy with phases at which minimum velocities occur. The motion characteristics varied depending on the artery, with the highest motion being observed for RCA. The phases with the lowest mean velocities provided the best visualization. Though more than one phase of relative minimum velocity was observed for each artery, the most consistent image quality was observed during mid-diastole ("diastasis") of the cardiac cycle and was judged to be superior to other reconstructed phases in 92% of the cases. In the process, we also investigated correlation between cardiac arterial states and other measures of motion, such as the left ventricular volume during a cardiac cycle, which earlier has been demonstrated as an example of how anatomic-specific information can be used in a knowledge-based cardiac CT algorithm. Using these estimates in characterizing cardiac motion also provides realistic simulation models for higher heart rates and also in optimizing volume reconstructions for individual segments of the cardiac anatomy.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Eletrocardiografia/métodos , Coração/diagnóstico por imagem , Coração/fisiopatologia , Imageamento Tridimensional/métodos , Movimento , Idoso , Algoritmos , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Técnica de Subtração , Tomografia Computadorizada Espiral
19.
J Clin Neurophysiol ; 7(3): 417-41, 1990 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2211996

RESUMO

Neonatal EEG interpretation can aid in the estimation of central nervous system maturation, as well as provide diagnostic and prognostic information of the high-risk infant. However, one cannot easily visualize the complex interrelationships coupling EEG and polysomnographic components of the EEG-sleep rhythm. This is particularly relevant for the preterm neonate, in whom a rudimentary sleep cycle has not yet been clearly delineated. Computer analysis can augment the information derived from the visual interpretation of scalp-generated EEG activity. Automated techniques for EEG-sleep analysis have only recently been applied to a neonatal population. Such studies have been limited to full-term rather than preterm infants and rely on conventional methods that assume stationarity of neurophysiologic signals. We describe a computer system that simultaneously compares behavioral and electrographic components of EEG-sleep in a manner that preserves the integrity of the signals over time, while investigating the time- and frequency-dependent relationships among signals. Strategies for on-line and off-line editing, data storage, and off-line signal processing are described. Computational algorithms regarding analyses of EEG power, motility, and cardiorespiratory data are being used to study the ontogeny of EEG-sleep in asymptomatic preterm and full-term neonates. Computer strategies are based on both principles of stationarity and nonstationarity of physiologic signals and are applied depending on the temporal resolution required for specific signal processing needs.


Assuntos
Eletroencefalografia/instrumentação , Recém-Nascido/fisiologia , Processamento de Sinais Assistido por Computador , Fases do Sono/fisiologia , Sistemas Computacionais , Potenciais Evocados/fisiologia , Humanos , Redes Locais , Minicomputadores , Software
20.
J Heart Valve Dis ; 10(1): 49-56, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11206768

RESUMO

BACKGROUND AND AIM OF THE STUDY: The non-invasive evaluation of mitral valve area is often used in the assessment of patients with mitral stenosis. The pressure half-time method is commonly used to calculate valve area, but is inaccurate in many clinical scenarios. We sought to quantify the effects of changing cardiac output on the accuracy of mitral valve area determination. METHODS: Thirteen patients with mitral stenosis underwent routine stress echocardiography with resting and peak exercise results compared. A previously described and clinically validated mathematical model of the cardiovascular system was used to validate the clinical results. Seven different loading conditions for each of four different stenotic valve areas were modeled. RESULTS: In patients, with increasing cardiac output, pressure half-time decreased (-30.6+/-35.3 ms/l/min) and calculated valve area increased by 0.25+/-0.30 cm2/l/min. By continuity, it appeared that approximately half of this increase was due to actual valve orifice stretching, the remainder reflecting fundamental changes in the relationship between half-time and valve area. Mathematical modeling resulted in similar changes in pressure half-time and calculated valve area (0.06 to 0.12 cm2/l/min, p = 0.20 versus clinical results). CONCLUSION: Changes in cardiac output result in predictable changes in pressure half-time, and should be considered when performing serial examinations in patients with mitral stenosis.


Assuntos
Pressão Sanguínea/fisiologia , Débito Cardíaco/fisiologia , Ecocardiografia , Teste de Esforço , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Simulação por Computador , Diástole/fisiologia , Ecocardiografia Doppler , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Estenose da Valva Mitral/fisiopatologia , Modelos Teóricos , Volume Sistólico/fisiologia , Sístole/fisiologia , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa