Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Gastroenterology ; 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39214503

RESUMO

BACKGROUND & AIMS: The authors assessed whether familial colorectal cancer (FCRC) surveillance in individuals without hereditary CRC can be optimized METHODS: The Adenoma and Serrated Pathway to Colorectal Cancer-FCRC model simulates CRC development in individuals with a family history of CRC at 2-fold and 4-fold increased CRC risk compared with the general population. The authors simulated a strategy without surveillance, the current Dutch guideline (5-yearly colonoscopy between ages 45 and 75 years), and the following 3 sets of alternative strategies: colonoscopy surveillance, surveillance combining colonoscopy and fecal immunochemical test (FIT), and FIT-based surveillance. Each set included a range of strategies differing in age range and test interval. The optimal strategy was defined as the strategy with highest quality-adjusted life-years (QALYs) satisfying all of the following criteria: in the (near-)efficiency area of the cost-effectiveness frontier and compared with current surveillance; noninferior effectiveness; no substantial increase in colonoscopy burden; and not more expensive. RESULTS: The optimal strategy was 10-yearly colonoscopy with 2-yearly FIT between colonoscopies from ages 40 to 80 years for both 2-fold and 4-fold increased CRC risk. At 2-fold risk, this strategy prevented 0.8 more CRC deaths, gained 15.8 more QALYs at 731 fewer colonoscopies, and saved €98,000 over the lifetime of 1000 individuals compared with current surveillance. At 4-fold risk, figures were 2.1 more CRC deaths prevented, 37.0 more QALYs gained at 567 fewer colonoscopies, and €127,000 lower costs. Current surveillance was not (near-)efficient. CONCLUSIONS: FIT could play an important role in FCRC surveillance. Surveillance with 10-yearly colonoscopy and 2-yearly FIT between colonoscopies from ages 40 to 80 years increased QALYs and reduced colonoscopy burden and costs compared with current FCRC surveillance.

2.
Gastroenterology ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39218164

RESUMO

BACKGROUND & AIMS: Colonoscopy-based surveillance to prevent colorectal cancer (CRC) causes substantial burden for patients and health care. Stool tests may help to reduce surveillance colonoscopies by limiting colonoscopies to individuals at increased risk of advanced neoplasia. METHODS: This cross-sectional observational study included individuals aged 50-75 years with surveillance indication. Before bowel preparation, participants collected samples for a multitarget stool DNA test and 2 fecal immunochemical tests (FITs). Test accuracy was calculated for all surveillance indications. For the post-polypectomy indication only, which is the most common and is associated with a relatively low CRC risk, long-term impact of stool-based surveillance was evaluated with the Adenoma and Serrated Pathway to Colorectal Cancer model. Stool-based strategies were simulated to tune each test's positivity threshold to obtain strategies at least as effective as colonoscopy surveillance. RESULTS: There were 3453 individuals with results for all stool tests and colonoscopy; 2226 had previous polypectomy, 1003 had previous CRC, and 224 had a familial risk. Areas under the receiver operating characteristic curve for advanced neoplasia were 0.72 (95% CI, 0.69-0.75) for the multitarget stool DNA test, 0.61 (95% CI, 0.58-0.64) for the FIT OC-SENSOR (Eiken Chemical Co, Tokyo, Japan) and 0.59 (95% CI, 0.56-0.61) for the FIT FOB-Gold (Sentinel, Milan, Italy). Stool-based post-polypectomy surveillance strategies at least as effective as colonoscopy surveillance reduced the number of colonoscopies by 15%-41% and required 5.6-9.5 stool tests over a person's lifetime. Multitarget stool DNA-based surveillance was more costly than colonoscopy surveillance, whereas FIT-based surveillance saved costs. CONCLUSIONS: This study found that stool-based post-polypectomy surveillance strategies can be safe and cost-effective, with potential to reduce the number of colonoscopies by up to 41%. CLINICALTRIALS: gov, Number: NCT02715141.

3.
Lancet Oncol ; 25(3): 326-337, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38346438

RESUMO

BACKGROUND: The faecal immunochemical test (FIT) is widely employed for colorectal cancer screening. However, its sensitivity for advanced precursor lesions remains suboptimal. The multitarget FIT (mtFIT), measuring haemoglobin, calprotectin, and serpin family F member 2, has demonstrated enhanced sensitivity for advanced neoplasia, especially advanced adenomas, at equal specificity to FIT. This study aimed to prospectively validate and investigate the clinical utlitity of mtFIT versus FIT in a setting of population-based colorectal cancer screening. METHODS: Individuals aged 55-75 years and who were eligible for the Dutch national FIT-based colorectal cancer screening programme were invited to submit both a FIT and mtFIT sample collected from the same bowel movement. Positive FIT (47 µg/g haemoglobin cutoff) or mtFIT (based on decision-tree algorithm) led to a colonoscopy referral. The primary outcome was the relative detection rate of mtFIT versus FIT for all advanced neoplasia. Secondary outcomes were the relative detection rates of colorectal cancer, advanced adenoma, and advanced serrated polyps individually and the long-term effect of mtFIT-based versus FIT-based programmatic screening on colorectal cancer incidence, mortality, and cost, determined with microsimulation modelling. The study has been registered in ClinicalTrials.gov, NCT05314309, and is complete. FINDINGS: Between March 25 and Dec 7, 2022, 35 786 individuals were invited to participate in the study, of whom 15 283 (42·7%) consented, and 13 187 (86·3%) of 15 283 provided both mtFIT and FIT samples with valid results. Of the 13 187 participants, 6637 (50·3%) were male and 6550 (49·7%) were female. mtFIT showed a 9·11% (95% CI 8·62-9·61) positivity rate and 2·27% (95% CI 2·02-2·54) detection rate for advanced neoplasia, compared with a positivity rate of 4·08% (3·75-4·43) and a detection rate of 1·21% (1·03-1·41) for FIT. Detection rates of mtFIT versus FIT were 0·20% (95% CI 0·13-0·29) versus 0·17% (0·11-0·27) for colorectal cancer; 1·64% (1·43-1·87) versus 0·86% (0·72-1·04) for advanced adenoma, and 0·43% (0·33-0·56) versus 0·17% (0·11-0·26) for advanced serrated polyps. Modelling demonstrated that mtFIT-based screening could reduce colorectal cancer incidence by 21% and associated mortality by 18% compared with the current Dutch colorectal cancer screening programme, at feasible costs. Furthermore, at equal positivity rates, mtFIT outperformed FIT in terms of diagnostic yield. At an equally low positivity rate, mtFIT-based screening was predicted to further decrease colorectal cancer incidence by 5% and associated mortality by 4% compared with FIT-based screening. INTERPRETATION: The higher detection rate of mtFIT for advanced adenoma compared with FIT holds the potential to translate into additional and clinically meaningful long-term colorectal cancer incidence and associated mortality reductions in programmatic colorectal cancer screening. FUNDING: Stand Up to Cancer, Dutch Cancer Society, Dutch Digestive Foundation, and Health~Holland.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Detecção Precoce de Câncer , Defecação , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Adenoma/diagnóstico , Adenoma/epidemiologia , Hemoglobinas
4.
Value Health ; 27(4): 397-404, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38141815

RESUMO

OBJECTIVES: To facilitate informed decision making on participating in colorectal cancer (CRC) screening, we assessed the benefit-harm balance of CRC screening for a wide range of subgroups over different time horizons. METHODS: The study combined incidence proportions of benefits and harms of (not) participating in CRC screening estimated by the Adenoma and Serrated pathway to CAncer microsimulation model, a preference eliciting survey, and benefit-harm balance modeling combining all outcomes to determine the net health benefit of CRC screening over 10, 20, and 30 years. Probability of net health benefit was estimated for 210 different subgroups based on age, sex, previous participation in CRC screening, and lifestyle. RESULTS: CRC screening was net beneficial in 183 of 210 subgroups over 30 years (median probability [MP] of 0.79, interquartile range [IQR] of 0.69-0.85) across subgroups. Net health benefit was greater for men (MP 0.82; IQR 0.69-0.89) than women (MP 0.76; IQR 0.67-0.83) and for those without history of participation in previous screenings (MP 0.84; IQR 0.80-0.89) compared with those with (MP 0.69; IQR 0.59-0.75). Net health benefit decreased with increasing age, from MP of 0.84 (IQR 0.80-0.86) at age 55 to 0.61 (IQR 0.56-0.71) at age 75. Shorter time horizons led to lower benefit, with MP of 0.70 (IQR 0.62-0.80) over 20 years and 0.54 (IQR 0.48-0.67) over 10 years. CONCLUSIONS: Our benefit-harm analysis provides information about net health benefit of screening participation, based on important characteristics and preferences of individuals, which could assist screening invitees in making informed decisions on screening participation.


Assuntos
Neoplasias Colorretais , Detecção Precoce de Câncer , Masculino , Humanos , Feminino , Idoso , Lactente , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Tomada de Decisões , Programas de Rastreamento
5.
Rheumatology (Oxford) ; 62(10): 3366-3372, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36799560

RESUMO

OBJECTIVES: Self-monitoring and patient-initiated care (PIC) leads to fewer outpatient clinic visits in patients with established RA with low disease activity (LDA) while healthcare outcomes are similar. This study assesses the cost-effectiveness of PIC with self-monitoring. METHODS: A 12-month randomized controlled trial was performed with 49 patients in the PIC with self-monitoring group (app-group) and 53 in usual care. The usual care group continued with preplanned visits. The app group had one planned follow-up visit after 12 months and monitored their RA disease activity in a smartphone app. Both groups could make additional appointments at liberty. We included adult RA patients with a disease duration of over 2 years, a disease activity score 28 (DAS28) below 3.2 that were stable on medication for at least 6 months. The effect measure, the DAS28, was measured at 12 months and healthcare resource usage and productivity losses were measured at 3, 6, 9 and 12 months. RESULTS: There was no significant difference in mean change of DAS28 (-0.04 mean difference, 95% CI: -0.39, 0.30), nor a statistically significant difference in total costs (mean difference €514, 95% CI:-€266, €3690) in the app group compared with the usual care group. The probability that the app was cost-effective was 0.37 and 0.57 at a willingness-to-pay threshold of 0 and 50 000 €/point improvement DAS28, respectively. CONCLUSION: Although rheumatic care costs were significantly lower in the app group, total costs and effects of PIC with self-monitoring were not different from usual care in RA patients with LDA.


Assuntos
Análise de Custo-Efetividade , Assistência ao Paciente , Adulto , Humanos , Análise Custo-Benefício
6.
Endoscopy ; 54(1): 88-99, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34872120

RESUMO

BACKGROUND : The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 - 5 mm). METHODS : A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds. RECOMMENDATION 1: In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1-5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1-5 mm in the rectosigmoid. Histopathology is used as the gold standard.Level of agreement 95 %. RECOMMENDATION 2: In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1-5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1-5 mm. Histopathology is used as the gold standard.Level of agreement 100 %. CONCLUSION : The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Endoscopia Gastrointestinal , Humanos
7.
Prev Med ; 164: 107187, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35963311

RESUMO

Longitudinal adherence to colorectal cancer (CRC) screening is reported using different summarizing measures, which hampers international comparison. We provide evidence to guide recommendations on which longitudinal adherence measure to report. Using adherence data over four stool-based CRC screening rounds in three countries, we calculated six summarizing adherence measures; adherence over all rounds, adherence per round, rescreening, full programme adherence (yes/no), regularity (never/inconsistent/consistent screenees) and number of times participated. For each measure, we calculated the accuracy in capturing the observed adherence patterns. Using the ASCCA model, we predicted screening effectiveness when using summarizing measures as model input versus the observed adherence patterns. Adherence over all rounds in the Italian, Spanish and Dutch cohorts was 64.9%, 42.8% and 61.5%, respectively, and the proportion of consistent screenees was 50.9%, 26.3% and 45.7%. Number of times participated and regularity were most accurate and resulted in similar model-predicted screening effectiveness as simulating the observed adherence patterns of Italy, Spain and the Netherlands (mortality reductions: 24.4%, 16.9% and 23.5%). Adherence over all rounds and adherence per round were least accurate. Screening effectiveness was overestimated when using adherence over all rounds (mortality reductions: 26.8%, 19.4% and 25.7%) and adherence per round (mortality reductions: 26.8%, 19.5% and 25.9%). To conclude, number of times participated and regularity were most accurate and resulted in similar model-predicted screening effectiveness as using the observed adherence patterns. However they require longitudinal data. To facilitate international comparison of CRC screening programme performance, consensus on an accurate adherence measure to report should be reached.


Assuntos
Neoplasias Colorretais , Detecção Precoce de Câncer , Humanos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/prevenção & controle , Consenso , Fezes , Itália/epidemiologia , Espanha/epidemiologia , Países Baixos/epidemiologia
8.
Ann Intern Med ; 174(9): 1224-1231, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34280333

RESUMO

BACKGROUND: The fecal immunochemical test (FIT) is used in colorectal cancer (CRC) screening, yet it leaves room for improvement. OBJECTIVE: To develop a multitarget FIT (mtFIT) with better diagnostic performance than FIT. DESIGN: Diagnostic test accuracy study. SETTING: Colonoscopy-controlled series. PARTICIPANTS: Persons (n = 1284) from a screening (n = 1038) and referral (n = 246) population were classified by their most advanced lesion (CRC [n = 47], advanced adenoma [n = 135], advanced serrated polyp [n = 30], nonadvanced adenoma [n = 250], and nonadvanced serrated polyp [n = 53]), along with control participants (n = 769). MEASUREMENTS: Antibody-based assays were developed and applied to leftover FIT material. Classification and regression tree (CART) analysis was applied to biomarker concentrations to identify the optimal combination for detecting advanced neoplasia. Performance of this combination, the mtFIT, was cross-validated using a leave-one-out approach and compared with FIT at equal specificity. RESULTS: The CART analysis showed a combination of hemoglobin, calprotectin, and serpin family F member 2-the mtFIT-to have a cross-validated sensitivity for advanced neoplasia of 42.9% (95% CI, 36.2% to 49.9%) versus 37.3% (CI, 30.7% to 44.2%) for FIT (P = 0.025), with equal specificity of 96.6%. In particular, cross-validated sensitivity for advanced adenomas increased from 28.1% (CI, 20.8% to 36.5%) to 37.8% (CI, 29.6% to 46.5%) (P = 0.006). On the basis of these results, early health technology assessment indicated that mtFIT-based screening could be cost-effective compared with FIT. LIMITATION: Study population is enriched with persons from a referral population. CONCLUSION: Compared with FIT, the mtFIT showed better diagnostic accuracy in detecting advanced neoplasia because of an increased detection of advanced adenomas. Moreover, early health technology assessment indicated that these results provide a sound basis to pursue further development of mtFIT as a future test for population-based CRC screening. A prospective screening trial is in preparation. PRIMARY FUNDING SOURCE: Stand Up to Cancer/Dutch Cancer Society, Dutch Digestive Foundation, and HealthHolland.


Assuntos
Neoplasias Colorretais/diagnóstico , Testes Diagnósticos de Rotina/normas , Fezes/química , Programas de Rastreamento/instrumentação , Idoso , Biomarcadores Tumorais/química , Colonoscopia , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Int J Cancer ; 148(11): 2702-2711, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33460468

RESUMO

Patient's quality of life should be included in clinical decision making regarding the administration of adjuvant chemotherapy (ACT) in stage II/III colon cancer. Therefore, quality of life, summarized as health utility (HU), was evaluated for patients treated with and without ACT. Furthermore, the role of chemotherapy-induced peripheral neuropathy (CIPN) on HU was evaluated. Patients diagnosed with stage II/III colon cancer between 2011 and 2019 and participating in the Prospective Dutch ColoRectal Cancer cohort were included (n = 914). HU scores were assessed with the EQ-5D-5L at baseline, 3, 6, 12, 18, and 24 months. Patients treated with ACT received mainly capecitabine and oxaliplatin (57%) or capecitabine monotherapy (40%) (average duration: 3.5 months). HU 3 to 18 months after diagnosis (potential ACT period + 12 months follow-up) was compared between patients treated with and without ACT using a mixed model adjusted for age, sex and education level. Subsequently, the CIPN sensory, motor and autonomy scales, measured using the EORTC QLQ-CIPN20, were independently included in the model to evaluate the impact of neuropathy. Using a mixed model, a significant difference of -0.039 (95% confidence interval: -0.062; -0.015) in HU was found between patients treated with and without ACT. Including the CIPN sensory, motor and autonomy scales decreased the difference with 0.019, 0.015 and 0.02, respectively. HU 3 to 18 months after diagnosis is significantly lower in patients treated with ACT vs without ACT. This difference is on the boundary of clinical relevance and appears to be partly related to the sensory and motor neuropathy-related side effects of ACT.


Assuntos
Capecitabina/uso terapêutico , Quimioterapia Adjuvante/efeitos adversos , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Oxaliplatina/uso terapêutico , Doenças do Sistema Nervoso Periférico/epidemiologia , Idoso , Capecitabina/efeitos adversos , Tomada de Decisão Clínica , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Oxaliplatina/efeitos adversos , Doenças do Sistema Nervoso Periférico/induzido quimicamente , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
10.
Gastrointest Endosc ; 94(4): 812-822.e43, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33887268

RESUMO

BACKGROUND AND AIMS: One reason the optical diagnosis strategy for diminutive colorectal polyps has not yet been implemented is that the current competence criteria (Preservation and Incorporation of Valuable Endoscopic Innovation [PIVI] initiative) are difficult to use in daily practice. To provide guidance for setting alternative easy-to-adopt competence criteria, we determined the lowest proportion of diminutive polyps that should have a correct optical diagnosis to meet the PIVI. METHODS: For this simulation study, we used datasets from 2 prospectively collected cohorts of patients who underwent colonoscopy in either a primary colonoscopy or fecal immunochemical test (FIT) screening setting. In the simulation approach, virtual endoscopists or computer-aided diagnosis systems performed optical diagnosis of diminutive polyps with a fixed diagnostic performance level (strategy) on all individuals in the cohort who had ≥1 diminutive polyp. Strategies were defined by systematically varying the proportion of correct optical diagnoses for each polyp subtype (ie, adenomas, hyperplastic polyps, sessile serrated lesions). For each strategy, we determined whether PIVI-1 (≥90% agreement with U.S. or European Society for Gastrointestinal Endoscopy [ESGE] surveillance guidelines) and PIVI-2 (≥90% negative predictive value [NPV] for neoplastic lesions in the rectosigmoid) were met using Monte Carlo sampling with 1000 repetitions, with histology as reference. RESULTS: The level of overall diagnostic accuracy to achieve the PIVI differed significantly depending on the clinical setting and guidelines used. In the colonoscopy screening setting, all diagnostic strategies in which 92% of all diminutive polyps (regardless of histology) were diagnosed correctly led to 90% or more agreement with U.S. surveillance intervals (ie, PIVI-1). For all diagnostic strategies in which ≥89% of all diminutive polyps were correctly diagnosed, at least 90% NPV was achieved (ie, PIVI-2). For the FIT screening setting, values were respectively ≥77% and ≥94%. When using ESGE guidelines, PIVI-1 was in both settings already met when 40% of all diminutive polyps were diagnosed correctly. CONCLUSIONS: In contrast to the fixed PIVI criteria, our simulation study shows that different thresholds for the proportion of correctly diagnosed diminutive polyps lead to different clinical consequences depending on guidelines and clinical setting. However, this target proportion of diminutive colorectal polyps correctly diagnosed with optical diagnosis represents easier-to-adopt competence criteria.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adenoma/diagnóstico por imagem , Adenoma/patologia , Colo/patologia , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Humanos , Imagem de Banda Estreita , Valor Preditivo dos Testes , Reto
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa