Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Allergy Asthma Immunol ; 130(2): 199-205.e2, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36288782

RESUMO

BACKGROUND: Air pollution is associated with poor asthma outcomes. High-efficiency particulate air air purifiers may reduce air pollution and thus improve asthma outcomes. However, the efficacy of such devices for this purpose remains inconclusive. OBJECTIVE: To investigate the effects of reducing the levels of pollutants on asthma outcomes in adults, using a novel Dyson high-efficiency particulate air air purifier. METHODS: In a single-center, double-blinded, randomized controlled trial, participants (N = 50) were randomized at a 1:1 ratio to active filters (intervention) or to dummy filters (placebo) for a total of 78 weeks. The primary outcomes were the changes in Asthma Control Questionnaire 6 (ACQ6) and Asthma-specific Quality of Life Questionnaire (AQLQ) scores from baseline. The secondary outcomes were changes in indoor air pollution and lung function measurements. The coronavirus disease 2019 pandemic limited spirometry measurements to 2 time points and assessment of fractional exhaled nitric oxide and bronchial hyperresponsiveness to baseline only. RESULTS: Air pollutant levels were significantly lower in the intervention group compared with the placebo group (P = .0003). Both groups had a significant improvement in their ACQ6 and AQLQ. However, there were no significant between-group differences in ACQ6, AQLQ, or spirometry, compared with baseline in multivariable repeated measures models. CONCLUSION: The Dyson air purifier significantly improved air quality. However, there were no significant improvements in asthma control, quality of life, or measures of lung function in the intervention group compared with the control group despite improvements in indoor air quality. Larger, extended studies are required to confirm or refute these findings, especially given that the coronavirus disease 2019 pandemic prevented the procurement of detailed objective data. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT04729530; ttps://clinicaltrials.gov/ct2/show/NCT04729530.


Assuntos
Filtros de Ar , Poluição do Ar em Ambientes Fechados , Asma , COVID-19 , Adulto , Humanos , Qualidade de Vida , Asma/tratamento farmacológico , Poluição do Ar em Ambientes Fechados/análise , Método Duplo-Cego
2.
JMIR Res Protoc ; 10(7): e28624, 2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34313599

RESUMO

BACKGROUND: Indoor air quality has been shown to influence asthma control and outcomes. Air purifiers and high-efficiency particulate air filtration devices can improve indoor air quality by reducing the indoor levels of air pollution and allergens. However, the influence of this improved indoor air quality on asthma control remains unclear; hence, randomized controlled trials are needed to further elucidate this phenomenon. OBJECTIVE: This study aims to investigate the effect of reducing the levels of allergens and pollutants in the bedroom and living room through the use of Dyson air purifiers (Dyson Pure Cool) on asthma control. METHODS: This is an 18-month long, investigator-led, randomized, double-blinded, placebo-controlled, single-center trial. Subjects will be randomized in a 1:1 ratio to active or placebo Dyson filters. The primary outcome is the change in the scores of Asthma Control Questionnaire 6 and Asthma-specific Quality of Life Questionnaire from baseline. Secondary outcomes include changes in lung function (forced expiratory volume in one second, forced expiratory volume in one second/forced vital capacity ratio, and midexpiratory flows), peak expiratory flow measurements, airway hyperresponsiveness (assessed by methacholine bronchial challenge), fractional exhaled nitric oxide, and indoor air pollutant levels. The sample size will be 50 subjects, and all subjects will have a confirmed diagnosis of mild persistent to moderate persistent asthma along with an Asthma Control Questionnaire 6 score of >1.5. RESULTS: This study was approved by the West Midlands Research Ethics Committee (18/WM/0277). The study results will be published in peer-reviewed scientific journals; presented at relevant scientific conferences; and shared in plain English with participants in our newsletters, in our clinics, and via the David Hide Asthma and Allergy Research Centre website. Our trial began in September 2019 and is expected to end in August 2021. CONCLUSIONS: This is a double-blinded, placebo-controlled, randomized, investigator-led study to investigate the efficacy of a novel air purifier in improving asthma control in adults. The trial period of 18 months will facilitate the collection of robust data and will therefore generate clear signals. However, this extended trial duration may lead to patient withdrawal. Furthermore, this trial is conducted at a single center and in a location with a homogenous cohort of people, which may affect translatability. Nonetheless, it is hoped that the findings of this trial may help further inform clinicians regarding the utility of this novel device as an adjunct in asthma care. TRIAL REGISTRATION: ClinicalTrials.gov NCT04729530; https://clinicaltrials.gov/ct2/show/NCT04729530. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/28624.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa