Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Nat Methods ; 21(5): 804-808, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38191935

RESUMO

Neuroimaging research requires purpose-built analysis software, which is challenging to install and may produce different results across computing environments. The community-oriented, open-source Neurodesk platform ( https://www.neurodesk.org/ ) harnesses a comprehensive and growing suite of neuroimaging software containers. Neurodesk includes a browser-accessible virtual desktop, command-line interface and computational notebook compatibility, allowing for accessible, flexible, portable and fully reproducible neuroimaging analysis on personal workstations, high-performance computers and the cloud.


Assuntos
Neuroimagem , Software , Neuroimagem/métodos , Humanos , Interface Usuário-Computador , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem
2.
Res Sq ; 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36993557

RESUMO

Neuroimaging data analysis often requires purpose-built software, which can be challenging to install and may produce different results across computing environments. Beyond being a roadblock to neuroscientists, these issues of accessibility and portability can hamper the reproducibility of neuroimaging data analysis pipelines. Here, we introduce the Neurodesk platform, which harnesses software containers to support a comprehensive and growing suite of neuroimaging software (https://www.neurodesk.org/). Neurodesk includes a browser-accessible virtual desktop environment and a command line interface, mediating access to containerized neuroimaging software libraries on various computing platforms, including personal and high-performance computers, cloud computing and Jupyter Notebooks. This community-oriented, open-source platform enables a paradigm shift for neuroimaging data analysis, allowing for accessible, flexible, fully reproducible, and portable data analysis pipelines.

3.
Neuroinformatics ; 20(3): 811-824, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35266105

RESUMO

Accurate electromagnetic modeling of the head of a subject is of main interest in the fields of source reconstruction and brain stimulation. Those processes rely heavily on the quality of the model and, even though the geometry of the tissues can be extracted from magnetic resonance images (MRI) or computed tomography (CT), their physical properties such as the electrical conductivity are difficult to measure with non intrusive techniques. In this paper, we propose a tool to assess the uncertainty in the model parameters, the tissue conductivity, as well as compute a parametric forward models for electroencephalography (EEG) and transcranial direct current stimulation (tDCS) current distribution.


Assuntos
Estimulação Transcraniana por Corrente Contínua , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Simulação por Computador , Eletroencefalografia/métodos , Fenômenos Eletromagnéticos , Imageamento por Ressonância Magnética/métodos , Estimulação Transcraniana por Corrente Contínua/métodos
4.
JCI Insight ; 6(24)2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34784296

RESUMO

BACKGROUNDTight relationships between sleep quality, cognition, and amyloid-ß (Aß) accumulation, a hallmark of Alzheimer's disease (AD) neuropathology, have been shown. Sleep arousals become more prevalent with aging and are considered to reflect poorer sleep quality. However, heterogeneity in arousals has been suggested while their associations with Aß and cognition are not established.METHODSWe recorded undisturbed night-time sleep with EEG in 101 healthy individuals aged 50-70 years, devoid of cognitive and sleep disorders. We classified spontaneous arousals according to their association with muscular tone increase (M+/M-) and sleep stage transition (T+/T-). We assessed cortical Aß burden over earliest affected regions via PET imaging and assessed cognition via neuropsychological testing.RESULTSArousal types differed in their oscillatory composition in θ (4-8 Hz) and ß (16-30 Hz) EEG bands. Furthermore, T+M- arousals, interrupting sleep continuity, were positively linked to Aß burden (P = 0.0053, R²ß* = 0.08). By contrast, more prevalent T-M+ arousals, upholding sleep continuity, were associated with lower Aß burden (P = 0.0003, R²ß* = 0.13), and better cognition, particularly over the attentional domain (P < 0.05, R²ß* ≥ 0.04).CONCLUSIONContrasting with what is commonly accepted, we provide empirical evidence that arousals are diverse and differently associated with early AD-related neuropathology and cognition. This suggests that sleep arousals, and their coalescence with other brain oscillations during sleep, may actively contribute to the beneficial functions of sleep and constitute markers of favorable brain and cognitive health trajectories.TRIAL REGISTRATIONEudraCT 2016-001436-35.FUNDINGFRS-FNRS Belgium (FRSM 3.4516.11), Actions de Recherche Concertées Fédération Wallonie-Bruxelles (SLEEPDEM 17/27-09), ULiège, and European Regional Development Fund (Radiomed Project).


Assuntos
Peptídeos beta-Amiloides/metabolismo , Cognição/fisiologia , Heterogeneidade Genética , Qualidade do Sono , Sono/genética , Idoso , Nível de Alerta , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
JCI Insight ; 6(2)2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33290274

RESUMO

BACKGROUNDNeuronal hyperexcitability characterizes the early stages of Alzheimer's disease (AD). In animals, early misfolded tau and amyloid-ß (Aß) protein accumulation - both central to AD neuropathology - promote cortical excitability and neuronal network dysfunction. In healthy humans, misfolded tau and Aß aggregates are first detected, respectively, in the brainstem and frontomedial and temporobasal cortices, decades prior to the onset of AD cognitive symptoms. Whether cortical excitability is related to early brainstem tau - and its associated neuroinflammation - and cortical Aß aggregations remains unknown.METHODSWe probed frontal cortex excitability, using transcranial magnetic stimulation combined with electroencephalography, in a sample of 64 healthy late-middle-aged individuals (50-69 years; 45 women and 19 men). We assessed whole-brain [18F]THK5351 PET uptake as a proxy measure of tau/neuroinflammation, and we assessed whole-brain Aß burden with [18F]Flutemetamol or [18F]Florbetapir radiotracers.RESULTSWe found that higher [18F]THK5351 uptake in a brainstem monoaminergic compartment was associated with increased cortical excitability (r = 0.29, P = 0.02). By contrast, [18F]THK5351 PET signal in the hippocampal formation, although strongly correlated with brainstem signal in whole-brain voxel-based quantification analyses (P value corrected for family-wise error [PFWE-corrected] < 0.001), was not significantly associated with cortical excitability (r = 0.14, P = 0.25). Importantly, no significant association was found between early Aß cortical deposits and cortical excitability (r = -0.20, P = 0.11).CONCLUSIONThese findings reveal potential brain substrates for increased cortical excitability in preclinical AD and may constitute functional in vivo correlates of early brainstem tau accumulation and neuroinflammation in humans.TRIAL REGISTRATIONEudraCT 2016-001436-35.FUNDINGF.R.S.-FNRS Belgium, Wallonie-Bruxelles International, ULiège, Fondation Simone et Pierre Clerdent, European Regional Development Fund.


Assuntos
Aminopiridinas/farmacocinética , Tronco Encefálico/diagnóstico por imagem , Tronco Encefálico/metabolismo , Córtex Cerebral/fisiopatologia , Envelhecimento Saudável/metabolismo , Quinolinas/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Idoso , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologia , Doença de Alzheimer/fisiopatologia , Peptídeos beta-Amiloides/metabolismo , Córtex Cerebral/patologia , Estudos Transversais , Diagnóstico Precoce , Eletroencefalografia , Feminino , Radioisótopos de Flúor/farmacocinética , Neuroimagem Funcional , Envelhecimento Saudável/patologia , Envelhecimento Saudável/fisiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estimulação Magnética Transcraniana , Proteínas tau/metabolismo
6.
Clocks Sleep ; 2(3): 258-272, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32803153

RESUMO

Arousals during sleep are transient accelerations of the EEG signal, considered to reflect sleep perturbations associated with poorer sleep quality. They are typically detected by visual inspection, which is time consuming, subjective, and prevents good comparability across scorers, studies and research centres. We developed a fully automatic algorithm which aims at detecting artefact and arousal events in whole-night EEG recordings, based on time-frequency analysis with adapted thresholds derived from individual data. We ran an automated detection of arousals over 35 sleep EEG recordings in healthy young and older individuals and compared it against human visual detection from two research centres with the aim to evaluate the algorithm performance. Comparison across human scorers revealed a high variability in the number of detected arousals, which was always lower than the number detected automatically. Despite indexing more events, automatic detection showed high agreement with human detection as reflected by its correlation with human raters and very good Cohen's kappa values. Finally, the sex of participants and sleep stage did not influence performance, while age may impact automatic detection, depending on the human rater considered as gold standard. We propose our freely available algorithm as a reliable and time-sparing alternative to visual detection of arousals.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa