Rev Sci Instrum ; 79(2 Pt 2): 02C114, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315240

RESUMO

The JT-60U negative ion source has been designed to produce high current beams of 22 A through grids of 1080 apertures (five segments with nine rows of 24 apertures). One of the key issues is to steer such a high current beam through the multiaperture grids in order to focus the overall beam envelope because the beamlet-beamlet interaction may deflect the outer beamlets outward due to unbalanced space charge repulsion. To clarify the beam deflection in the JT-60U negative ion source, the beamlet trajectory in a multiaperture ion source was calculated by a three-dimensional simulation code. The measured angles of the outmost beamlets were in agreement with the calculated results where space charge of the beamlets was taken into account. It is noticed that the deflection of the outermost beamlet due to the beamlet-beamlet interaction is saturated at 5.2 mrad outward for beamlets more than ten.

2.
Rev Sci Instrum ; 79(2 Pt 2): 02A519, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315140

RESUMO

The first long pulse production of high power D(-) ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D(-) ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D(-) ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D(-) ion beams of 12.5 and 9.8 A were produced at 340 keV with cesium seeding at a rate of approximately 14 microg/s into the ion sources. The pulse duration of these D(-) ion beams was extended step by step, and then was successfully extended up to 18 s without degradation of the negative ion production. The D(-) ion beams were neutralized to yield 3.6 MW D(0) beams by a gas cell, and then injected into the JT-60 U plasma. Further, a slight reduction of D(-) ion beam power allowed the longer injection duration of 21 s at a D(0) beam power of 3.2 MW. The success in the long pulse production of a high power D(-) ion beam shows that negative ion beams can be produced during a few tens of seconds without degradations of negative ion production and the voltage holding in a large Cs-seeded negative ion source.

3.
Rev Sci Instrum ; 79(2 Pt 2): 02C105, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315231

RESUMO

In the large area negative ion source for the LHD negative-ion-(H(-))-based neutral beam system, (I) we used the spectrometer to measure caesium lines in the source plasma during beam shots. (II) With Doppler-shifted measurements, the H(alpha) line at three different locations along the beam as well as the spectrum profile for cases of different plasma grid areas. (III) Caesium deposition monitor with a high speed shutter was tested to measure the weight of the deposited Cs layer. In the observation, cleaner spectra of Doppler-shifted H(alpha) line with only a small level of background light were obtained at a new observation port which viewed the blueshifted light in the drift region after the accelerator of a LHD ion source. Both the amounts of Cs I (852 nm, neutral Cs(0)) and Cs II (522 nm, Cs(+)) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. It was thought that this was because the cesium was evaporated/sputtered from the source back plate by the back-streaming positive ions. Cs deposition rate to the crystal sensor measured by adjusting the shutter open time was evaluated to be 2.9 nanograms/s cm(2) for preliminary testing. More neutral Cs tended to be evolved in the source after arc discharge. Much Cs could be consumed in a high rate-pulsed operation (such as LHD source).

4.
Rev Sci Instrum ; 87(2): 02B304, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932032

RESUMO

Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltage holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.

5.
Rev Sci Instrum ; 87(2): 02B322, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932050

RESUMO

In order to realize negative ion sources and accelerators to be applicable to International Thermonuclear Experimental Reactor and JT-60 Super Advanced, a large cesium (Cs)-seeded negative ion source and a multi-aperture and multi-stage electric acceleration have been developed at Japan Atomic Energy Agency (JAEA). Long pulse production and acceleration of the negative ion beams have been independently carried out. The long pulse production of the high current beams has achieved 100 s at the beam current of 15 A by modifying the JT-60 negative ion source. The pulse duration time is increased three times longer than that before the modification. As for the acceleration, a pulse duration time has been also extended two orders of magnitudes from 0.4 s to 60 s. The developments of the negative ion source and acceleration at JAEA are well in progress towards the realization of the negative ion sources and accelerators for fusion applications.

6.
Rev Sci Instrum ; 85(2): 02B312, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593589

RESUMO

Long pulse beam extraction with a current density of 120 A/m(2) for 100 s has been achieved with a newly developed plasma grid (PG) for the JT-60SA negative ion source which is designed to produce high power and long pulse beams with a negative ion current of 130 A/m(2) (22 A) and a pulse length of 100 s. The PG temperature is regulated by fluorinated fluids in order to keep the high PG temperature for the cesium-seeded negative ion production. The time constant for temperature controllability of the PG was measured to be below 10 s, which was mainly determined by the heat transfer coefficient of the fluorinated fluid. The measured decay time of the negative ion current extracted from the actively temperature-controlled PG was 430 s which was sufficient for the JT-60SA requirement, and much longer than that by inertial-cooling PG of 60 s. Obtained results of the long pulse capability are utilized to design the full size PG for the JT-60SA negative ion source.

7.
Rev Sci Instrum ; 83(2): 02B117, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380274

RESUMO

Vacuum insulation on a large size negative ion accelerator with multiple extraction apertures and acceleration grids for fusion application was experimentally examined and designed. In the experiment, vacuum insulation characteristics were investigated in the JT-60 negative ion source with >1000 apertures on the grid with the surface area of ∼2 m(2). The sustainable voltages varied with a square root of the gap lengths between the grids, and decreased with number of the apertures and with the surface area of the grids. Based on the obtained results, the JT-60SA (super advanced) negative ion source is designed to produce 22 A, 500 keV D(-) ion beams for 100 s.

8.
Rev Sci Instrum ; 83(2): 02B119, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380276

RESUMO

In a multi-aperture multi-grid accelerator of the ITER neutral beam injector, the beamlets are deflected due to space charge repulsion between beamlets and beam groups, and also due to magnetic field. Moreover, the beamlet deflection is influenced by electric field distortion generated by grid support structure. Such complicated beamlet deflections and the compensations have been examined utilizing a three-dimensional beam analysis. The space charge repulsion and the influence by the grid support structure were studied in a 1∕4 model of the accelerator including 320 beamlets. Beamlet deflection due to the magnetic field was studied by a single beamlet model. As the results, compensation methods of the beamlet deflection were designed, so as to utilize a metal bar (so-called field shaping plate) of 1 mm thick beneath the electron suppression grid (ESG), and an aperture offset of 1 mm in the ESG.

9.
Rev Sci Instrum ; 81(2): 02B113, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192419

RESUMO

In JAEA, research and developments to realize high power accelerator (1 MeV, 40 AD(-) ion beams for 3600 s) for ITER have been carried out experimentally and numerically utilizing a five stage MAMuG (Multiaperture, Multigrid) accelerator. In this paper, the extension of the gap length, which is required to improve the voltage holding capability, is examined in two dimensional beam optics analyses and also from view point of stripping loss of ions. In order to suppress excess power loadings due to the direct interception of negative ions, which is issued in long pulse tests, the beamlet deflection is analyzed in three dimensional multibeamlet analyses. The necessary modifications shown above are applied to the MAMuG accelerator for coming long pulse tests in JAEA and ITER.

10.
Rev Sci Instrum ; 81(2): 02B112, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20225407

RESUMO

Developments of the large negative ion source have been progressed in the high-energy, high-power, and long-pulse neutral beam injector for JT-60 Super Advanced. Countermeasures have been studied and tested for critical issues of grid heat load and voltage holding capability. As for the heat load of the acceleration grids, direct interception of D- ions was reduced by adjusting the beamlet steering. As a result, the heat load was reduced below an allowable level for long-pulse injections. As for the voltage holding capability, local electric field was mitigated by tuning gap lengths between large-area acceleration grids in the accelerator. As a result, the voltage holding capability was improved up to the rated value of 500 kV. To investigate the voltage holding capability during beam acceleration, the beam acceleration test is ongoing with new extended gap.

11.
Rev Sci Instrum ; 81(2): 02A719, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20225405

RESUMO

Voltage holding capability of JT-60 negative ion source that has a large electrostatic negative ion accelerator with 45 cm x 1.1 m acceleration grids was experimentally examined and improved to realize 500 keV, 22 A, and 100 s D- ion beams for JT-60 Super Advanced. The gap lengths in the acceleration stages were extended to reduce electric fields in a gap between the large grids and at the corner of the support flanges from the original 4-5 to 3-4 kV/mm. As a result, the voltage holding capability without beam acceleration has been successfully improved from 400 to 500 kV. The pulse duration to hold 500 kV reached 40 s of the power supply limitation.