Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Curr Atheroscler Rep ; 26(7): 305-315, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38727963

RESUMO

PURPOSE OF REVIEW: Despite recent advances, coronary artery disease remains one of the leading causes of mortality worldwide. Noninvasive imaging allows atherosclerotic phenotyping by measurement of plaque burden, morphology, activity and inflammation, which has the potential to refine patient risk stratification and guide personalized therapy. This review describes the current and emerging roles of advanced noninvasive cardiovascular imaging methods for the assessment of coronary artery disease. RECENT FINDINGS: Cardiac computed tomography enables comprehensive, noninvasive imaging of the coronary vasculature, and is used to assess luminal stenoses, coronary calcifications, and distinct adverse plaque characteristics, helping to identify patients prone to future events. Novel software tools, implementing artificial intelligence solutions, can automatically quantify and characterize atherosclerotic plaque from standard computed tomography datasets. These quantitative imaging biomarkers have been shown to improve patient risk stratification beyond clinical risk scores and current clinical interpretation of cardiac computed tomography. In addition, noninvasive molecular imaging in higher risk patients can be used to assess plaque activity and plaque thrombosis. Noninvasive imaging allows unique insight into the burden, morphology and activity of atherosclerotic coronary plaques. Such phenotyping of atherosclerosis can potentially improve individual patient risk prediction, and in the near future has the potential for clinical implementation.


Assuntos
Doença da Artéria Coronariana , Fenótipo , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/diagnóstico , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Medição de Risco/métodos
2.
J Nucl Cardiol ; 30(4): 1558-1569, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36645580

RESUMO

BACKGROUND: Positron emission tomography (PET) is the clinical gold standard for quantifying myocardial blood flow (MBF). Pericoronary adipose tissue (PCAT) attenuation may detect vascular inflammation indirectly. We examined the relationship between MBF by PET and plaque burden and PCAT on coronary CT angiography (CCTA). METHODS: This post hoc analysis of the PACIFIC trial included 208 patients with suspected coronary artery disease (CAD) who underwent [15O]H2O PET and CCTA. Low-attenuation plaque (LAP, < 30HU), non-calcified plaque (NCP), and PCAT attenuation were measured by CCTA. RESULTS: In 582 vessels, 211 (36.3%) had impaired per-vessel hyperemic MBF (≤ 2.30 mL/min/g). In multivariable analysis, LAP burden was independently and consistently associated with impaired hyperemic MBF (P = 0.016); over NCP burden (P = 0.997). Addition of LAP burden improved predictive performance for impaired hyperemic MBF from a model with CAD severity and calcified plaque burden (P < 0.001). There was no correlation between PCAT attenuation and hyperemic MBF (r = - 0.11), and PCAT attenuation was not associated with impaired hyperemic MBF in univariable or multivariable analysis of all vessels (P > 0.1). CONCLUSION: In patients with stable CAD, LAP burden was independently associated with impaired hyperemic MBF and a stronger predictor of impaired hyperemic MBF than NCP burden. There was no association between PCAT attenuation and hyperemic MBF.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Estudos Prospectivos , Doença da Artéria Coronariana/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Tecido Adiposo/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
3.
J Thromb Thrombolysis ; 48(4): 610-618, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31359325

RESUMO

Both transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) have been proven to effectively correct von Willebrand Factor (vWF) pathologies, however there is limited data simultaneously comparing outcomes of both approaches. We prospectively enrolled patients with severe aortic stenosis referred for TAVI (n = 52) or SAVR (n = 48). In each case, vWF antigen (vWF:Ag), vWF activity (vWF:Ac) and activity-to-antigen (vWF:Ac/Ag) ratio were assessed at baseline, 24 h and 72 h after procedure. VWF abnormalities were defined as reduced vWF:Ac/Ag ratio (< 0.8). Bleeding events in both arms were classified according to Valve Academic Research Consortium (VARC-2) definitions. Overall, there was no difference between patients referred for TAVI and SAVR in vWF:Ac (1.62 ± 0.52 vs 1.71 ± 0.64; p = 0.593), vWF:Ag (1.99 ± 0.81 vs 2.04 ± 0.81; p = 0.942) or vWF:Ac/Ag ratio (0.84 ± 0.16 vs 0.85 ± 0.12; p = 0.950). Pathological vWF:Ac/Ag ratio was found in 20 (38%) TAVI and 15 (31%) SAVR patients (p = 0.407). Normalization of vWF:Ac/Ag ratio at day 3 after procedure was achieved in 19 (95%) TAVI and 13 (87%) SAVR patients (p = 0.439). Similar prevalence of major or life-threatening bleedings (MLTB) after TAVI and SAVR in entire groups was observed (19% vs. 23%, p = 0.652). VWF abnormalities were associated with higher incidence of MLTB in SAVR (53% vs 9%, p < 0.001), but not TAVI (15% vs. 22%, p = 0.132). Accordingly, in receiver-operating characteristic curve analysis vWF:Ac/Ag ratio < 0.8 showed significant sensitivity and specificity for predicting MLTB in SAVR group (AUC 0.735, 95% CI 0.538-0.931, p = 0.019). We proved that abnormal function of vWF is corrected successfully after both TAVI and SAVR, but vWF abnormalities are predictive of MLTB only in surgical patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/etiologia , Valor Preditivo dos Testes , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fator de von Willebrand/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
4.
Echocardiography ; 36(6): 1132-1138, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31012135

RESUMO

INTRODUCTION: Infective endocarditis (IE) may take different faces in patients after transcatheter aortic valve implantation (TAVI). OBJECTIVES: The primary aim of this study was to describe echocardiographic and clinical characteristics of TAVI's patients suffered from IE. METHODS: In a single-center, retrospective study we analyzed 311 consecutive patients treated with TAVI for severe aortic stenosis between 2010 and 2018. RESULTS: According to modified Duke criteria, we confirmed IE in 2.2% of the cohort, however PVE of TAVI's valve in 1.2% only; rest of the group suffered from CDRiE and IE of the mitral valve. In PVE's group vegetations were localized inside the frame with or without bioprosthesis moderate stenosis or regurgitation. Only 1 pts developed significant TAVI's bioprosthesis' paravalvular leak. We observed no native aortic anulus involvement. Mortality rate in the PVE-TAVI's group was 75% regardless of the type of treatment. CONCLUSIONS: The above findings show that IE following TAVI is a serious complication and various scenarios (also CDRiE and native valve IE) should be considered.


Assuntos
Ecocardiografia/métodos , Endocardite/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos
5.
Catheter Cardiovasc Interv ; 91(1): 115-123, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28843025

RESUMO

BACKGROUND: Coronary artery disease (CAD) and degenerative aortic stenosis often coexist. However, the impact of CAD and its management on the prognosis after transcatheter aortic valve implantation (TAVI) remains uncertain. We sought to evaluate the impact of obstructive CAD, SYNTAX score (Ss), and percutaneous coronary intervention (PCI) prior to TAVI on short-term outcome. METHODS: Overall, 896 patients who underwent TAVI after heart team decision was included. Pre-procedural angiograms were analysed to calculate baseline Ss (bSs) and residual Ss (rSs). Baseline, procedural and follow-up data up to 30 days was acquired from the national POL-TAVI registry. RESULTS: Patients with obstructive CAD at baseline (n = 462, 52%) had higher mortality as compared with the remaining (8.7 vs. 5.1%, log-rank P = 0.039). Also, after correction for confounding factors obstructive CAD was identified as independent predictor of mortality (hazard ratio [HR] 1.74, 95% confidence intervals [CIs] 1.03-2.94, P = 0.037). In obstructive CAD, neither bSs (AUC 0.47, CI 0.38-0.56, P = 0.47) nor rSs (AUC 0.47, CI 0.30-0.64, P = 0.72 for those undergoing PCI and AUC 0.48, CI 0.37-0.59, P = 0.75 for the remaining) was predictive of mortality. When revascularization status was considered, patients with PCI prior to TAVI had similar outcome as those without obstructive CAD at baseline (7.7 vs. 5.1%, log-rank P = 0.23) with no negative impact on mortality (HR 1.13, CI 0.62-2.09, P = 0.69). CONCLUSIONS: In conclusion, obstructive CAD at baseline evaluation for TAVI has independent negative impact on short-term prognosis. However, neither baseline nor residual Ss values have prognostic ability in patients undergoing TAVI. Revascularization prior to TAVI seems to improve survival to levels comparable with patients without obstructive CAD at baseline.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Polônia , Encaminhamento e Consulta , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
J Interv Cardiol ; 31(6): 861-869, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30009390

RESUMO

OBJECTIVE: To compare the safety and efficacy of transcathether aortic valve-in-valve implantation (ViV-TAVI) in degenerated stentless bioprostheses with failed stented valves and degenerated native aortic valves. INTRODUCTION: Little is known about ViV-TAVI in degenerated stentless valves. METHODS: Out of 45 ViV-TAVI procedures reported in the POL-TAVI registry, 20 failed stentless valves were compared with 25 stented prostheses and propensity-matched with 45 native TAVI cases. The mean follow-up was 633 (95% confidence interval [CI], 471-795) days and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. RESULTS: Patients with degenerated stentless valves were younger (65.6, CI 58-73.1 years vs 75.6, CI 72.2-78 [stented] vs 80.1, CI 78.7-81.6 y. [native], P < 0.001). Implantation was required later after surgery (11.5, CI 8-14.9 years) in the stentless cohort as compared with the stented one (6.2, CI 4.7-7.6 years, P = 0.006). ViV-TAVI in the stentless group was also associated with larger amount of contrast (211, CI 157-266 mL vs 135, CI 104-167 mL [stented] vs 132 (119-145) mL [native], P = 0.022). Using VARC-2 composite endpoints, ViV-TAVI in stentless prostheses was characterized by a lower device success (50% vs 76% in stented vs 88.9% in native TAVI, P < 0.001), but comparable early safety up to 30 days (73.7% vs 84% vs 81.8%, respectively, log-rank P = 0.667) and long-term clinical efficacy beyond 30 days (72.2% vs 72% vs 73.8%, respectively, log-rank P = 0.963). CONCLUSIONS: Despite technical challenges and a lower device success, ViV-TAVI in stentless aortic bioprostheses achieves similar safety, efficacy, and functional improvement as in stented or degenerated native valves.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Sistema de Registros , Stents , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Postepy Kardiol Interwencyjnej ; 20(2): 139-147, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39022713

RESUMO

Introduction: Global warming is claimed to be an important cardiovascular disease risk factor. The air pollution and ambient temperatures are believed to have a significant influence on increased morbidity and premature deaths. Aim: To point out possible causative factors for coronary angiography progression in patients presenting with chronic coronary syndrome. Material and methods: There were 66 patients (41 [62%] men and 25 [38%] women) with a median age of 71.5 (62-76) years, who underwent repeated coronary angiographies due to chronic coronary syndrome within a median time interval of 145 (96-296) days. In 18 (27%) patients coronary artery lesion progression was observed despite optimal pharmacotherapy. The demographical, clinical, and personalised epidemiological factors including air pollution particles and ambient temperature exposure were taken into account in the analysis. Results: In the multivariate logistic regression model with backward stepwise elimination method, tropical nights (p = 0.047) and mean daily temperatures (p = 0.043) were revealed as predictors of coronary lesion progression > 30%. The analysis of seasonal temperature changes showed significant differences related to minimal winter temperatures between both groups (p = 0.018). Conclusions: Coronary artery lesion progression can be related to either high values of daily temperatures or to low ambient temperature. The dichotomous characteristics of temperature exposure to atherosclerosis progression suggest a detrimental role of environmental extremities on human health.

9.
J Cardiovasc Dev Dis ; 10(5)2023 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-37233183

RESUMO

Aortic stenosis is the most common form of valve disease in the Western world and a major healthcare burden. Although echocardiography remains the central modality for the diagnosis and assessment of aortic stenosis, recently, advanced cardiac imaging with cardiovascular magnetic resonance, computed tomography, and positron emission tomography have provided invaluable pathological insights that may guide the personalized management of the disease. In this review, we discuss applications of these novel non-invasive imaging modalities for establishing the diagnosis, monitoring disease progression, and eventually planning the invasive treatment of aortic stenosis.

10.
J Cardiovasc Dev Dis ; 10(1)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36661916

RESUMO

Mechanical circulatory support (MCS) allows for functional left and right heart ventricle replacement. MCS induces a systemic inflammatory reaction and prothrombotic state leading to an increased risk of thrombus formation. The extracellular vesicles (EVs) are nanoparticles released from active/injured cells characterized by prothrombotic properties. Simple inflammatory parameters from whole blood count analysis have established a clinical role in everyday practice to describe immune-inflammatory activation. We hypothesized that increased plasma concentrations of EVs might be associated with the proinflammatory and pro-thrombotic characteristics of left ventricle assist device (LVAD) and right ventricle assist device (RVAD) devices. We presented a pilot study showing the concentration of peripheral blood serum, right and left ventricle mechanical assist device extracellular concentration in relation to thrombotic complication in patients treated with a biventricular pulsatile assist device (BIVAD). The observation was based on 12 replacements of pulsatile pumps during 175 days of observation. The proinflammatory characteristics of LVAD were noted. The proinflammatory and procoagulant activation by RVAD was observed. The results may provide possible explanations for the worse results of right-sided mechanical supports observed in clinical practice.

11.
Postepy Kardiol Interwencyjnej ; 19(3): 243-250, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37854973

RESUMO

Introduction: Coexistence of coronary artery disease (CAD) in patients with severe aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) raises questions regarding the safety and efficacy of TAVI in this subset of patients. Aim: To evaluate the impact of previous coronary revascularization in terms of percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) on clinical outcomes after TAVI. Material and methods: A total of 507 consecutive patients who underwent TAVI were divided into: non-revascularization (NR), post-PCI and post-CABG groups. The endpoints were established according to VARC-2 definitions. Results: Patients with previous coronary revascularization (36.7% of the population) were younger, more often male and their EuroSCORE II risk evaluation was significantly higher (NR 7.9% vs. post-PCI 8.0% vs. post-CABG 20.5%, p < 0.0001). Patients after PCI or CABG prior to TAVI had similar 30-day all-cause mortality rates as those without coronary revascularization at baseline (NR vs. post-PCI vs. post-CABG: 8.1% vs. 5.5% vs. 6.8%, respectively; p = 0.6). There were no differences in 12-month all-cause mortality rates between groups (NR vs. post-PCI vs. post-CABG: 15.3% vs. 14.2% vs. 16.9%, respectively; log-rank p = 0.67). In the Cox proportional-hazards regression model, acute kidney injury stage 2-3 (HR = 3.7, 95% CI: 2.14-6.33; p < 0.001) and post-TAVI stroke (HR = 3.5, 95% CI: 1.57-7.8; p = 0.002) were independently correlated with 1-year mortality. Conclusions: TAVI seems to be a safe and effective procedure for the treatment of severe AS in patients with previous coronary revascularization.

12.
Adv Med Sci ; 68(2): 396-401, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37837798

RESUMO

PURPOSE: The normal healthy valve is devoid of inflammatory cells, however background of aortic stenosis (AS) may include inflammatory processes. Moreover, the link between hyperparathyroidism and heart failure is postulated. Simple whole blood analysis with indices is a beneficial tool in cardiovascular diseases' assessment. The purpose of the study was to evaluate correlation between parathyroid hormone (PTH) and simple blood parameters in severe AS. MATERIAL AND METHODS: The study included 62 patients with severe AS. Patients with inflammatory or autoimmune co-morbidities were excluded. Blood samples were collected, and clinical and demographic data were analyzed. RESULTS: The final study group comprised 55 patients (31 females, 56.4%; mean age 77.13 (SD 6.76)). In 23 patients (41.8%), PTH concentration was markedly increased. The study group was divided into two subgroups according to the PTH concentration. Patients from both groups did not differ significantly in terms of age and co-morbidities. PTH concentration correlated positively with monocyte-lymphocyte ratio (MLR) (p â€‹= â€‹0.008, Spearman rho 0.356) and platelet-lymphocyte ratio (PLR) (p â€‹= â€‹0.047, Spearman rho 0.269), creatinine level (p â€‹= â€‹0.001, Spearman rho 0.425) and glomerular filtration rate (GFR-MDRD) (p â€‹= â€‹0.009, Spearman rho -0.349). The multivariable logistic regression with backward analysis revealed MLR (p â€‹= â€‹0.029) and GFR (p â€‹= â€‹0.028) as independent significant predictors of abnormal PTH values. The receiver operator characteristics (ROC) curve was performed for the model of MLR and GFR-MDRD (AUC â€‹= â€‹0.777), yielding the sensitivity of 60.9% and specificity of 90.6%. CONCLUSIONS: PTH concentration correlates with monocyte-to-lymphocyte and platelet-to-lymphocyte ratios in calcified AS.


Assuntos
Estenose da Valva Aórtica , Monócitos , Feminino , Humanos , Idoso , Hormônio Paratireóideo , Linfócitos , Plaquetas , Neutrófilos , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos
13.
Kardiol Pol ; 81(4): 373-380, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36594529

RESUMO

BACKGROUND: The carotid artery is an alternative access route for transcatheter aortic valve implantation (TAVI), especially useful in patients unsuitable for traditional access routes including transfemoral (TF), subclavian, transapical, and aortic. AIMS: To investigate the feasibility and safety of transcarotid (TC) access for TAVI in comparison to the TF approach in a multicenter setting. METHODS: A total of 41 patients, treated between December 2014 and December 2018, were retrospectively reported to the Polish Registry of Common Carotid Artery Access for TAVI (POL-CAROTID). The median follow-up time was 619 (365-944) days, and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. Clinical outcomes were compared with 41 propensity-matched TF-TAVI patients. RESULTS: The mean (standard deviation [SD]) patients' age was 78.0 (7.2) years, and 29 patients (70.7%) were men. Prohibitive iliofemoral anatomy and/or obesity (46.3%) and/or the presence of a stent graft in the abdominal aorta (31.7%) were the most common indications for TC-TAVI. Device success for TC-TAVI was comparable with the matched TF-TAVI group (90.2% vs. 95.3%, respectively, P = 0.396), and no periprocedural mortality was observed. Moreover, early safety was similar between the two groups (92.7% vs. 95.3%, respectively, log-rank P = 0.658) with only 1 case of non-disabling stroke during the first month after TC-TAVI. Consequently, no cerebrovascular events were observed in the mid-term, and the clinical efficacy of TC-TAVI corresponded well with TF-TAVI (90.2% vs. 92.7%, respectively, log-rank P = 0.716). A total of 4 (9.8%) deaths were noted in the TC-TAVI cohort in comparison to 3 (7.3%) in the TF-TAVI group. CONCLUSIONS: The results of the study indicated that the first cohort of Polish patients with implantations of second-generation transcarotid transcatheter heart valves had a similar prognosis to TF-TAVI with regard to safety and feasibility. TC access may be considered an optimal alternative for patients in whom the TF approach is precluded.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Artérias Carótidas , Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
14.
Eur Heart J Cardiovasc Imaging ; 24(12): 1653-1660, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37339331

RESUMO

AIMS: Aortic stenosis is characterized by fibrosis and calcification of the valve, with a higher proportion of fibrosis observed in women. Stenotic bicuspid aortic valves progress more rapidly than tricuspid valves, which may also influence the relative composition of the valve. We aimed to investigate the influence of cusp morphology on quantitative aortic valve composition quantified from contrast-enhanced computed tomography angiography in severe aortic stenosis. METHODS AND RESULTS: Patients undergoing transcatheter aortic valve implantation with bicuspid and tricuspid valves were propensity matched 1:1 by age, sex, and comorbidities. Computed tomography angiograms were analysed using semi-automated software to quantify the fibrotic and calcific scores (volume/valve annular area) and the fibro-calcific ratio (fibrotic score/calcific score). The study population (n = 140) was elderly (76 ± 10 years, 62% male) and had a peak aortic jet velocity of 4.1 ± 0.7 m/s. Compared with those with tricuspid valves (n = 70), patients with bicuspid valves (n = 70) had higher fibrotic scores [204 (interquartile range 118-267) vs. 144 (99-208) mm3/cm2, P = 0.006] with similar calcific scores (P = 0.614). Women had greater fibrotic scores than men in bicuspid [224 (181-307) vs. 169 (109-247) mm3/cm2, P = 0.042] but not tricuspid valves (P = 0.232). Men had greater calcific scores than women in both bicuspid [203 (124-355) vs. 130 (70-182) mm3/cm2, P = 0.008] and tricuspid [177 (136-249) vs. 100 (62-150) mm3/cm2, P = 0.004] valves. Among both valve types, women had a greater fibro-calcific ratio compared with men [tricuspid 1.86 (0.94-2.56) vs. 0.86 (0.54-1.24), P = 0.001 and bicuspid 1.78 (1.21-2.90) vs. 0.74 (0.44-1.53), P = 0.001]. CONCLUSIONS: In severe aortic stenosis, bicuspid valves have proportionately more fibrosis than tricuspid valves, especially in women.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/patologia , Doença da Válvula Aórtica Bicúspide/patologia , Fibrose
15.
Eur Heart J Qual Care Clin Outcomes ; 9(8): 768-777, 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36637410

RESUMO

AIMS: Prediction of adverse events in mid-term follow-up after transcatheter aortic valve implantation (TAVI) is challenging. We sought to develop and validate a machine learning model for prediction of 1-year all-cause mortality in patients who underwent TAVI and were discharged following the index procedure. METHODS AND RESULTS: The model was developed on data of patients who underwent TAVI at a high-volume centre between January 2013 and March 2019. Machine learning by extreme gradient boosting was trained and tested with repeated 10-fold hold-out testing using 34 pre- and 25 peri-procedural clinical variables. External validation was performed on unseen data from two other independent high-volume TAVI centres. Six hundred four patients (43% men, 81 ± 5 years old, EuroSCORE II 4.8 [3.0-6.3]%) in the derivation and 823 patients (46% men, 82 ± 5 years old, EuroSCORE II 4.7 [2.9-6.0]%) in the validation cohort underwent TAVI and were discharged home following the index procedure. Over the 12 months of follow-up, 68 (11%) and 95 (12%) subjects died in the derivation and validation cohorts, respectively. In external validation, the machine learning model had an area under the receiver-operator curve of 0.82 (0.78-0.87) for prediction of 1-year all-cause mortality following hospital discharge after TAVI, which was superior to pre- and peri-procedural clinical variables including age 0.52 (0.46-0.59) and the EuroSCORE II 0.57 (0.51-0.64), P < 0.001 for a difference. CONCLUSION: Machine learning based on readily available clinical data allows accurate prediction of 1-year all-cause mortality following a successful TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Lactente , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia
16.
J Cardiovasc Comput Tomogr ; 17(2): 112-119, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36670043

RESUMO

BACKGROUND: Distinct sex-related differences exist in coronary artery plaque burden and distribution. We aimed to explore sex differences in quantitative plaque burden by coronary CT angiography (CCTA) in relation to ischemia by invasive fractional flow reserve (FFR). METHODS: This post-hoc analysis of the PACIFIC trial included 581 vessels in 203 patients (mean age 58.1 â€‹± â€‹8.7 years, 63.5% male) who underwent CCTA and per-vessel invasive FFR. Quantitative assessment of total, calcified, non-calcified, and low-density non-calcified plaque burden were performed using semiautomated software. Significant ischemia was defined as invasive FFR ≤0.8. RESULTS: The per-vessel frequency of ischemia was higher in men than women (33.5% vs. 7.5%, p â€‹< â€‹0.001). Women had a smaller burden of all plaque subtypes (all p â€‹< â€‹0.01). There was no sex difference on total, calcified, or non-calcified plaque burdens in vessels with ischemia; only low-density non-calcified plaque burden was significantly lower in women (beta: -0.183, p â€‹= â€‹0.035). The burdens of all plaque subtypes were independently associated with ischemia in both men and women (For total plaque burden (5% increase): Men, OR: 1.15, 95%CI: 1.06-1.24, p â€‹= â€‹0.001; Women, OR: 1.96, 95%CI: 1.11-3.46, p â€‹= â€‹0.02). No significant interaction existed between sex and total plaque burden for predicting ischemia (interaction p â€‹= â€‹0.108). The addition of quantitative plaque burdens to stenosis severity and adverse plaque characteristics improved the discrimination of ischemia in both men and women. CONCLUSIONS: In symptomatic patients with suspected CAD, women have a lower CCTA-derived burden of all plaque subtypes compared to men. Quantitative plaque burden provides independent and incremental predictive value for ischemia, irrespective of sex.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Angiografia por Tomografia Computadorizada , Valor Preditivo dos Testes , Placa Aterosclerótica/complicações , Angiografia Coronária/métodos , Índice de Gravidade de Doença
17.
Kardiol Pol ; 2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37096948

RESUMO

BACKGROUND: Valve-in-valve transcatheter transfemoral mitral valve implantation (ViV-TMVI) is an emerging treatment alternative to reoperation in high surgical risk patients with a failed mitral bioprostheses. AIM: To describe characteristics and evaluate 30-day outcomes of ViV-TMVI in the Polish population. METHODS: Nationwide registry was initiated to collect data of all patients with failed mitral bioprosthesis undergoing ViV-TMVI in Poland. This study presents 30-days clinical and echocardiographic follow-up. RESULTS: Overall, 27 ViV-TMVI were performed in 8 centers until May 2022 (85% since 2020). Mean (standard deviation [SD]) age was 73 (11.6) years with the median (interquartile range [IQR]) STS score of 5.3% (4.3%-14.3%). Mean (SD) time between surgical implantation and ViV-TMVI was 8.2 (3.2) years. Failed Hancock II (29%) and Perimount Magna (22%) were most frequently treated. Mechanisms of failure were equally often pure mitral regurgitation or stenosis (both 37%) with mixed etiology in 26%. Balloon-expandable Sapien 3/Ultra were used in all but 1 patient. Technical success was 96.3% (1 patient required additional prosthesis). Mean (SD) transvalvular mitral gradient reached 6.7 (2.2) mm Hg and mitral valve area was 1.8 (0.4) cm². None of the patients had moderate or severe mitral regurgitation with only 14.8% graded as mild. In 92.6% device success (2 patients had mean gradient ≥10 mm Hg) and in 85.6% procedural success was present. There were no deaths, cerebrovascular events or need for mitral valve surgery during 30-day follow-up. CONCLUSIONS: In short-term observation ViV-TMVI is safe and effective alternative for patients with failed mitral bioprosthesis at high surgical risk of re-operation. Longer observations on larger sample are warranted.

18.
Br J Radiol ; 96(1149): 20220180, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37310152

RESUMO

OBJECTIVE: We aimed to evaluate the effectiveness of utilizing artificial intelligence (AI) to quantify the extent of pneumonia from chest CT scans, and to determine its ability to predict clinical deterioration or mortality in patients admitted to the hospital with COVID-19 in comparison to semi-quantitative visual scoring systems. METHODS: A deep-learning algorithm was utilized to quantify the pneumonia burden, while semi-quantitative pneumonia severity scores were estimated through visual means. The primary outcome was clinical deterioration, the composite end point including admission to the intensive care unit, need for invasive mechanical ventilation, or vasopressor therapy, as well as in-hospital death. RESULTS: The final population comprised 743 patients (mean age 65  ±â€¯ 17 years, 55% men), of whom 175 (23.5%) experienced clinical deterioration or death. The area under the receiver operating characteristic curve (AUC) for predicting the primary outcome was significantly higher for AI-assisted quantitative pneumonia burden (0.739, p = 0.021) compared with the visual lobar severity score (0.711, p < 0.001) and visual segmental severity score (0.722, p = 0.042). AI-assisted pneumonia assessment exhibited lower performance when applied for calculation of the lobar severity score (AUC of 0.723, p = 0.021). Time taken for AI-assisted quantification of pneumonia burden was lower (38 ± 10 s) compared to that of visual lobar (328 ± 54 s, p < 0.001) and segmental (698 ± 147 s, p < 0.001) severity scores. CONCLUSION: Utilizing AI-assisted quantification of pneumonia burden from chest CT scans offers a more accurate prediction of clinical deterioration in patients with COVID-19 compared to semi-quantitative severity scores, while requiring only a fraction of the analysis time. ADVANCES IN KNOWLEDGE: Quantitative pneumonia burden assessed using AI demonstrated higher performance for predicting clinical deterioration compared to current semi-quantitative scoring systems. Such an AI system has the potential to be applied for image-based triage of COVID-19 patients in clinical practice.


Assuntos
COVID-19 , Deterioração Clínica , Pneumonia , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , COVID-19/diagnóstico por imagem , Inteligência Artificial , Pulmão , SARS-CoV-2 , Mortalidade Hospitalar , Estudos Retrospectivos , Pneumonia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
19.
Kardiol Pol ; 80(7-8): 825-833, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35575408

RESUMO

BACKGROUND: Pulmonary hypertension related to left ventricle heart disease is a common finding in patients with severe aortic stenosis treated with transcatheter aortic valve implantation (TAVI) and is associated with a higher mortality rate. AIMS: The study aimed to analyze the influence of pulmonary artery systolic pressure (PASP) changes after TAVI on long-term survival. METHODS: TAVI was performed in 362 patients between January 2013 and December 2018. The study group comprised 210 patients who underwent a detailed 1-month follow-up. RESULTS: At 1-month, 142 had a stable or decreased PASP value (Group 1), while in 68 patients an increase was observed (Group 2). During 1-year follow-up, 20 patients died (9.5%), 9 in Group 1 and 11 in Group 2 (P = 0.02). The receiver operating characteristic (ROC) curve analysis (area under the curve [AUC], 0.750) revealed a significant value of 1-month measurement for 1-year mortality prediction. The cutoff for the PASP value predictive of mortality was ≤41 mm Hg. A Kaplan-Meier analysis showed significantly higher mortality in patients without a 1-month PASP decrease. In the multivariable analysis, PASP measured at 1-month after TAVI (hazard ratio, 1.040; 95% confidence interval, 1.019-1.062; P < 0.001) was an independent predictor of 1-year mortality. Each 1 mm Hg increase in PASP predicts a 4% increase in the risk of death. CONCLUSION: Decreased or stable value of PASP at 1-month follow-up may predict better 1-year survival after TAVI, while each 1 mm Hg increase in PASP confers a 4% greater risk of 1-year mortality.


Assuntos
Estenose da Valva Aórtica , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Pressão Sanguínea , Humanos , Hipertensão Pulmonar/complicações , Artéria Pulmonar , Fatores de Risco , Resultado do Tratamento
20.
Adv Clin Exp Med ; 31(9): 937-945, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35546564

RESUMO

BACKGROUND: Persistent inflammatory response after transcatheter aortic valve implantation (TAVI) is one of the possible causes of early and mid-term postprocedural adverse events. OBJECTIVES: To establish the predictive role of whole blood parameters on inflammatory response characteristics within a 1-year follow-up. MATERIAL AND METHODS: The study group comprised 163 consecutive patients (52.1% females), mean age 78.6 (±6.6) years (± standard deviation (SD)) who underwent TAVI and completed 1-year follow-up on-site examinations. Patients were retrospectively divided into acute kidney injury (AKI) and non-AKI subgroups. Clinical and laboratory data were collected. In-hospital and follow-up outcomes were assessed. RESULTS: The clinical and procedural details did not show significant differences between AKI and non-AKI groups. Neutrophil-to-lymphocyte ratio (NLR) decreased from baseline to measurement after 1 year with a statistically significant decline in the whole study population and non-AKI subgroup (both p = 0.005). The baseline NLR cutoff value of 4.2 for the non-AKI group ((area under the curve (AUC) = 0.718, p < 0.0001; sensitivity 46.27%, specificity 92.31%) and of 3.8 for the AKI group (AUC = 0.673, p = 0.0174; sensitivity 59.25%, specificity 84%) had prognostic properties for persistent NLR elevation. CONCLUSIONS: The NLR decreases after TAVI, and this phenomenon is more evident in patients without AKI. Furthermore, baseline NLR cutoff values may be considered predictors of persistence of inflammatory response.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Idoso , Estenose da Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Linfócitos , Masculino , Neutrófilos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa