Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(4)2023 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-36850670

RESUMO

We designed a tunable diode laser absorption spectroscopy (TDLAS) sensor for the online monitoring of CO2 and H2O concentrations. It comprised a small self-design multi-pass cell, home-made laser drive circuits, and a data acquisition circuit. The optical and electrical parts and the gas circuit were integrated into a portable carrying case (height = 134 mm, length = 388 mm, and width = 290 mm). A TDLAS drive module (size: 90 mm × 45 mm) was designed to realize the function of laser current and temperature control with a temperature control accuracy of ±1.4 mK and a current control accuracy of ±0.5 µA, and signal acquisition and demodulation. The weight and power consumption of the TDLAS system were only 5 kg and 10 W, respectively. Distributed feedback lasers (2004 nm and 1392 nm) were employed to target CO2 and H2O absorption lines, respectively. According to Allan analysis, the detection limits of CO2 and H2O were 0.13 ppm and 3.7 ppm at an average time of 18 s and 35 s, respectively. The system response time was approximately 10 s. Sensor performance was verified by measuring atmospheric CO2 and H2O concentrations for 240 h. Experimental results were compared with those obtained using a commercial instrument LI-7500, which uses non-dispersive infrared technology. Measurements of the developed gas analyzer were in good agreement with those of the commercial instrument, and its accuracy was comparable. Therefore, the TDLAS sensor has strong application prospects in atmospheric CO2 and H2O concentration detection and ecological soil flux monitoring.

2.
Opt Express ; 30(24): 43961-43972, 2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36523082

RESUMO

We report an open-path and anti-pollution multi-pass cell based tunable diode laser absorption spectroscopy (TDLAS) sensor, which was designed for online measurement of atmospheric H2O and CO2 fluxes. It is mainly composed of two plano-convex mirrors coated on a convex surface, which makes it different from traditional multi-pass cells. This design does not allow a direct contact between the coating layer of the lens and air, thereby realizing the anti-pollution effect of the coating layer. Two DFB lasers operating at 1392 nm and 2004 nm were employed to target H2O and CO2 absorption lines, respectively. Allan analysis of variance indicated that detection limits of H2O and CO2 were 5.98 ppm and 0.68 ppm, respectively, at an average time of 0.1 s. The sensor performance was demonstrated by measuring CO2 and H2O flux emissions at Jiangdu Agricultural Monitoring Station in Jiangsu Province. The results were compared with those obtained using the commercial instrument LI-7500, which is based on non-dispersive infrared technology. The developed gas analysis instrument exhibited good consistency with commercial instruments, and its accuracy was comparable; thus, it has strong application prospects for flux measurements in any ecosystem.

3.
Sensors (Basel) ; 20(5)2020 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-32110962

RESUMO

A fully integrated photoacoustic nitrogen dioxide (NO2) sensor is developed and demonstrated. In this sensor, an embedded photoacoustic cell was manufactured by using an up-to-date 3D printing technique. A blue laser diode was used as a light source for excitation of photoacoustic wave in the photoacoustic cell. The photoacoustic wave is detected by a sensitive microelectromechanical system (MEMS) microphone. Homemade circuits are integrated into the sensor for laser diode driving and signal processing. The sensor was calibrated by using a chemiluminescence NO-NO2-NOX gas analyzer. And the performance of this sensor was evaluated. The linear relationship between photoacoustic signals and NO2 concentrations was verified in a range of below 202 ppb. The limit of detection was determined to 0.86 ppb with an integration time of 1 s. The corresponding normalized noise equivalent absorption was 2.0 × 10-8 cm-1∙W∙Hz-1/2. The stability and the optimal integration time were evaluated with an Allan deviation analysis, from which a detection limit of 0.25 ppb at the optimal integration time of 240 s was obtained. The sensor was used to measure outdoor air and the results agree with that obtained from the NO-NO2-NOX gas analyzer. The low-cost and portable photoacoustic NO2 sensor has a potential application for atmospheric NO2 monitoring.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa