Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 74(5): 719-27, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19530147

RESUMO

OBJECTIVES: We evaluated the role of gender on clinical and angiographic results of the everolimus-eluting stent in the SPIRIT III trial. BACKGROUND: The SPIRIT III trial demonstrated superior efficacy of the XIENCE V everolimus-eluting stent compared with the TAXUS paclitaxel-eluting stent. Whether these results are applicable to women is unknown. METHODS: A total of 1,002 patients with coronary artery lesions of 28 mm or less long in 2.5-3.75 mm diameter vessels were prospectively randomized to receive percutaneous coronary intervention with either XIENCE V stent or TAXUS stent placement. Post hoc gender subset analysis was performed. RESULTS: A total of 669 patients (200 women) received the XIENCE V stent, and 332 patients (114 women) were assigned to the TAXUS stent. Women were older and had more hypertension and diabetes than men. At 1 year, rates of MACE (11.1% vs. 5.7%, P = 0.004), TVF (13.7% vs. 7.5%, P = 0.003), TVR (10.8% vs. 4.6%, P = 0.0007), and TLR (7.2% vs. 2.7%, P = 0.002) were higher in women compared with men. The difference in 1 year MACE and TVF rates between men and women remained after adjusting for baseline covariates. Although the angiographic characteristics at baseline were similar among the female cohort, women assigned to XIENCE V had lower in-stent late loss (0.19 vs. 0.42 mm, P = 0.01) compared with women treated with the TAXUS stent. Although 30-day clinical outcomes were similar for women treated with XIENCE V and TAXUS stents, at 1 year, women with XIENCE V stents had significantly lower MACE (8.2% vs. 16.1 %, P = 0.04) and TVR (3.1% vs. 8.9%, P = 0.03) compared with those treated with TAXUS stents. Stent thrombosis rates were similar between women receiving either XIENCE V or TAXUS stents. CONCLUSIONS: Women in the SPIRIT III trial had inherently higher MACE and TVF rates than men. However, the angiographic and clinical benefits of using XIENCE V stents are generalizable to women.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doenças Cardiovasculares/etiologia , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Everolimo , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores Sexuais , Método Simples-Cego , Sirolimo/administração & dosagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento , Saúde da Mulher
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa