Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
J Cell Sci ; 134(19)2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34494099

RESUMO

Ptychographic hard X-ray computed tomography (PXCT) is a recent method allowing imaging with quantitative electron-density contrast. Here, we imaged, at cryogenic temperature and without sectioning, cellular and subcellular structures of a chemically fixed and stained wild-type mouse retina, including axons and synapses, with complete isotropic 3D information over tens of microns. Comparison with tomograms of degenerative retina from a mouse model of retinitis pigmentosa illustrates the potential of this method for analyzing disease processes like neurodegeneration at sub-200 nm resolution. As a non-destructive imaging method, PXCT is very suitable for correlative imaging. Within the outer plexiform layer containing the photoreceptor synapses, we identified somatic synapses. We used a small region inside the X-ray-imaged sample for further high-resolution focused ion beam/scanning electron microscope tomography. The subcellular structures of synapses obtained with the X-ray technique matched the electron microscopy data, demonstrating that PXCT is a powerful scanning method for tissue volumes of more than 60 cells and sensitive enough for identification of regions as small as 200 nm, which remain available for further structural and biochemical investigations.


Assuntos
Retina , Tomografia , Animais , Imageamento Tridimensional , Camundongos , Microscopia Eletrônica , Sinapses , Tomografia Computadorizada por Raios X
2.
Nature ; 547(7663): 328-331, 2017 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-28726832

RESUMO

In soft ferromagnetic materials, the smoothly varying magnetization leads to the formation of fundamental patterns such as domains, vortices and domain walls. These have been studied extensively in thin films of thicknesses up to around 200 nanometres, in which the magnetization is accessible with current transmission imaging methods that make use of electrons or soft X-rays. In thicker samples, however, in which the magnetization structure varies throughout the thickness and is intrinsically three dimensional, determining the complex magnetic structure directly still represents a challenge. We have developed hard-X-ray vector nanotomography with which to determine the three-dimensional magnetic configuration at the nanoscale within micrometre-sized samples. We imaged the structure of the magnetization within a soft magnetic pillar of diameter 5 micrometres with a spatial resolution of 100 nanometres and, within the bulk, observed a complex magnetic configuration that consists of vortices and antivortices that form cross-tie walls and vortex walls along intersecting planes. At the intersections of these structures, magnetic singularities-Bloch points-occur. These were predicted more than fifty years ago but have so far not been directly observed. Here we image the three-dimensional magnetic structure in the vicinity of the Bloch points, which until now has been accessible only through micromagnetic simulations, and identify two possible magnetization configurations: a circulating magnetization structure and a twisted state that appears to correspond to an 'anti-Bloch point'. Our imaging method enables the nanoscale study of topological magnetic structures in systems with sizes of the order of tens of micrometres. Knowledge of internal nanomagnetic textures is critical for understanding macroscopic magnetic properties and for designing bulk magnets for technological applications.

3.
Nature ; 543(7645): 402-406, 2017 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-28300088

RESUMO

Modern nanoelectronics has advanced to a point at which it is impossible to image entire devices and their interconnections non-destructively because of their small feature sizes and the complex three-dimensional structures resulting from their integration on a chip. This metrology gap implies a lack of direct feedback between design and manufacturing processes, and hampers quality control during production, shipment and use. Here we demonstrate that X-ray ptychography-a high-resolution coherent diffractive imaging technique-can create three-dimensional images of integrated circuits of known and unknown designs with a lateral resolution in all directions down to 14.6 nanometres. We obtained detailed device geometries and corresponding elemental maps, and show how the devices are integrated with each other to form the chip. Our experiments represent a major advance in chip inspection and reverse engineering over the traditional destructive electron microscopy and ion milling techniques. Foreseeable developments in X-ray sources, optics and detectors, as well as adoption of an instrument geometry optimized for planar rather than cylindrical samples, could lead to a thousand-fold increase in efficiency, with concomitant reductions in scan times and voxel sizes.

4.
J Synchrotron Radiat ; 29(Pt 5): 1223-1231, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073881

RESUMO

The acquisition speed and spatial resolution of X-ray nanotomography have continuously improved over the last decades. Coherent diffraction-based techniques breach the 10 nm resolution barrier frequently and thus pose stringent demands on sample positioning accuracy and stability. At the same time there is an increasing desire to accommodate in situ or operando measurements. Here, an environmental control system for X-ray nanotomography is introduced to regulate the temperature of a sample from room temperature up to 850°C in a controlled atmospheric composition. The system allows for a 360° sample rotation, permitting tomographic studies in situ or operando free of missing wedge constraints. The system is implemented and available at the flOMNI microscope at the Swiss Light Source. In addition to the environmental control system itself, the related modifications of flOMNI are described. Tomographic measurements of a nanoporous gold sample at 50°C and 600°C at a resolution of sub-20 nm demonstrate the performance of the device.

5.
Nature ; 527(7578): 349-52, 2015 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-26581291

RESUMO

The mechanical properties of many materials are based on the macroscopic arrangement and orientation of their nanostructure. This nanostructure can be ordered over a range of length scales. In biology, the principle of hierarchical ordering is often used to maximize functionality, such as strength and robustness of the material, while minimizing weight and energy cost. Methods for nanoscale imaging provide direct visual access to the ultrastructure (nanoscale structure that is too small to be imaged using light microscopy), but the field of view is limited and does not easily allow a full correlative study of changes in the ultrastructure over a macroscopic sample. Other methods of probing ultrastructure ordering, such as small-angle scattering of X-rays or neutrons, can be applied to macroscopic samples; however, these scattering methods remain constrained to two-dimensional specimens or to isotropically oriented ultrastructures. These constraints limit the use of these methods for studying nanostructures with more complex orientation patterns, which are abundant in nature and materials science. Here, we introduce an imaging method that combines small-angle scattering with tensor tomography to probe nanoscale structures in three-dimensional macroscopic samples in a non-destructive way. We demonstrate the method by measuring the main orientation and the degree of orientation of nanoscale mineralized collagen fibrils in a human trabecula bone sample with a spatial resolution of 25 micrometres. Symmetries within the sample, such as the cylindrical symmetry commonly observed for mineralized collagen fibrils in bone, allow for tractable sampling requirements and numerical efficiency. Small-angle scattering tensor tomography is applicable to both biological and materials science specimens, and may be useful for understanding and characterizing smart or bio-inspired materials. Moreover, because the method is non-destructive, it is appropriate for in situ measurements and allows, for example, the role of ultrastructure in the mechanical response of a biological tissue or manufactured material to be studied.


Assuntos
Nanoestruturas/ultraestrutura , Espalhamento a Baixo Ângulo , Tomografia/métodos , Idoso , Colágeno/ultraestrutura , Humanos , Imageamento Tridimensional/métodos , Masculino , Coluna Vertebral/ultraestrutura , Difração de Raios X
6.
Nature ; 527(7578): 353-6, 2015 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-26581292

RESUMO

When used in combination with raster scanning, small-angle X-ray scattering (SAXS) has proven to be a valuable imaging technique of the nanoscale, for example of bone, teeth and brain matter. Although two-dimensional projection imaging has been used to characterize various materials successfully, its three-dimensional extension, SAXS computed tomography, poses substantial challenges, which have yet to be overcome. Previous work using SAXS computed tomography was unable to preserve oriented SAXS signals during reconstruction. Here we present a solution to this problem and obtain a complete SAXS computed tomography, which preserves oriented scattering information. By introducing virtual tomography axes, we take advantage of the two-dimensional SAXS information recorded on an area detector and use it to reconstruct the full three-dimensional scattering distribution in reciprocal space for each voxel of the three-dimensional object in real space. The presented method could be of interest for a combined six-dimensional real and reciprocal space characterization of mesoscopic materials with hierarchically structured features with length scales ranging from a few nanometres to a few millimetres--for example, biomaterials such as bone or teeth, or functional materials such as fuel-cell or battery components.


Assuntos
Espalhamento a Baixo Ângulo , Tomografia/métodos , Difração de Raios X , Colágeno/ultraestrutura , Humanos , Imageamento Tridimensional/métodos , Nanoestruturas/ultraestrutura , Dente/ultraestrutura
7.
Nano Lett ; 20(2): 1305-1314, 2020 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-31951418

RESUMO

X-ray tomography has become an indispensable tool for studying complex 3D interior structures with high spatial resolution. Three-dimensional imaging using soft X-rays offers powerful contrast mechanisms but has seen limited success with tomography due to the restrictions imposed by the much lower energy of the probe beam. The generalized geometry of laminography, characterized by a tilted axis of rotation, provides nm-scale 3D resolution for the investigation of extended (mm range) but thin (µm to nm) samples that are well suited to soft X-ray studies. This work reports on the implementation of soft X-ray laminography (SoXL) at the scanning transmission X-ray spectromicroscope of the PolLux beamline at the Swiss Light Source, Paul Scherrer Institut, which enables 3D imaging of extended specimens from 270 to 1500 eV. Soft X-ray imaging provides contrast mechanisms for both chemical sensitivity to molecular bonds and oxidation states and magnetic dichroism due to the much stronger attenuation of X-rays in this energy range. The presented examples of applications range from functionalized nanomaterials to biological photonic crystals and sophisticated nanoscaled magnetic domain patterns, thus illustrating the wide fields of research that can benefit from SoXL.


Assuntos
Meios de Contraste/química , Imageamento Tridimensional/métodos , Nanoestruturas/química , Tomografia por Raios X/métodos , Meios de Contraste/uso terapêutico , Humanos , Magnetismo , Microscopia Eletrônica de Varredura , Nanoestruturas/uso terapêutico , Fótons , Radiografia , Raios X
8.
Neuroimage ; 204: 116214, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31568873

RESUMO

While diffusion MRI (dMRI) is currently the method of choice to non-invasively probe tissue microstructure and study structural connectivity in the brain, its spatial resolution is limited and its results need structural validation. Current ex vivo methods employed to provide 3D fiber orientations have limitations, including tissue-distorting sample preparation, small field of view or inability to quantify 3D fiber orientation distributions. 3D fiber orientation in tissue sections can be obtained from 3D scanning small-angle X-ray scattering (3D sSAXS) by analyzing the anisotropy of scattering signals. Here we adapt the 3D sSAXS method for use in brain tissue, exploiting the high sensitivity of the SAXS signal to the ordered molecular structure of myelin. We extend the characterization of anisotropy from vectors to tensors, employ the Funk-Radon-Transform for converting scattering information to real space fiber orientations, and demonstrate the feasibility of the method in thin sections of mouse brain with minimal sample preparation. We obtain a second rank tensor representing the fiber orientation distribution function (fODF) for every voxel, thereby generating fODF maps. Finally, we illustrate the potential of 3D sSAXS by comparing the result with diffusion MRI fiber orientations in the same mouse brain. We show a remarkably good correspondence, considering the orthogonality of the two methods, i.e. the different physical processes underlying the two signals. 3D sSAXS can serve as validation method for microstructural MRI, and can provide novel microstructural insights for the nervous system, given the method's orthogonality to dMRI, high sensitivity to myelin sheath's orientation and abundance, and the possibility to extract myelin-specific signal and to perform micrometer-resolution scanning.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/ultraestrutura , Imagem de Difusão por Ressonância Magnética/normas , Fibras Nervosas Mielinizadas/ultraestrutura , Neuroimagem/normas , Tomografia Computadorizada por Raios X/normas , Difração de Raios X/normas , Animais , Estudos de Viabilidade , Camundongos , Neuroimagem/métodos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Difração de Raios X/métodos
9.
J Synchrotron Radiat ; 27(Pt 3): 779-787, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32381781

RESUMO

Small-angle scattering tensor tomography (SASTT) is a recently developed technique able to tomographically reconstruct the 3D reciprocal space from voxels within a bulk volume. SASTT extends the concept of X-ray computed tomography, which typically reconstructs scalar values, by reconstructing a tensor per voxel, which represents the local nanostructure 3D organization. In this study, the nanostructure orientation in a human trabecular-bone sample obtained by SASTT was validated by sectioning the sample and using 3D scanning small-angle X-ray scattering (3D sSAXS) to measure and analyze the orientation from single voxels within each thin section. Besides the presence of cutting artefacts from the slicing process, the nanostructure orientations obtained with the two independent methods were in good agreement, as quantified with the absolute value of the dot product calculated between the nanostructure main orientations obtained in each voxel. The average dot product per voxel over the full sample containing over 10 000 voxels was 0.84, and in six slices, in which fewer cutting artefacts were observed, the dot product increased to 0.91. In addition, SAXS tensor tomography not only yields orientation information but can also reconstruct the full 3D reciprocal-space map. It is shown that the measured anisotropic scattering for individual voxels was reproduced from the SASTT reconstruction in each voxel of the 3D sample. The scattering curves along different 3D directions are validated with data from single voxels, demonstrating SASTT's potential for a separate analysis of nanostructure orientation and structural information from the angle-dependent intensity distribution.


Assuntos
Imageamento Tridimensional/métodos , Coluna Vertebral/ultraestrutura , Tomografia Computadorizada por Raios X/métodos , Difração de Raios X/métodos , Anisotropia , Humanos , Espalhamento a Baixo Ângulo
10.
J Synchrotron Radiat ; 27(Pt 3): 730-736, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32381775

RESUMO

Across all branches of science, medicine and engineering, high-resolution microscopy is required to understand functionality. Although optical methods have been developed to `defeat' the diffraction limit and produce 3D images, and electrons have proven ever more useful in creating pictures of small objects or thin sections, so far there is no substitute for X-ray microscopy in providing multiscale 3D images of objects with a single instrument and minimal labeling and preparation. A powerful technique proven to continuously access length scales from 10 nm to 10 µm is ptychographic X-ray computed tomography, which, on account of the orthogonality of the tomographic rotation axis to the illuminating beam, still has the limitation of necessitating pillar-shaped samples of small (ca 10 µm) diameter. Large-area planar samples are common in science and engineering, and it is therefore highly desirable to create an X-ray microscope that can examine such samples without the extraction of pillars. Computed laminography, where the axis of rotation is not perpendicular to the illumination direction, solves this problem. This entailed the development of a new instrument, LamNI, dedicated to high-resolution 3D scanning X-ray microscopy via hard X-ray ptychographic laminography. Scanning precision is achieved by a dedicated interferometry scheme and the instrument covers a scan range of 12 mm × 12 mm with a position stability of 2 nm and positioning errors below 5 nm. A new feature of LamNI is a pair of counter-rotating stages carrying the sample and interferometric mirrors, respectively.

11.
Angew Chem Int Ed Engl ; 59(39): 17266-17271, 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-32579755

RESUMO

Hydrodesulphurization, the removal of sulphur from crude oils, is an essential catalytic process in the petroleum industry safeguarding the production of clean hydrocarbons. Sulphur removal is critical for the functionality of downstream processes and vital to the elimination of environmental pollutants. The effectiveness of such an endeavour is among other factors determined by the structural arrangement of the heterogeneous catalyst. Namely, the accessibility of the catalytically active molybdenum disulphide (MoS2 ) slabs located on the surfaces of a porous alumina carrier. Here, we examined a series of pristine sulfided Mo and NiMo hydrodesulphurization catalysts of increasing metal loading prepared on commercial alumina carriers using ptychographic X-ray computed nanotomography. Structural analysis revealed a build consisting of two interwoven support matrix elements differing in nanoporosity. With increasing metal loading, approaching that of industrial catalysts, these matrix elements exhibit a progressively dissimilar MoS2 surface coverage as well as MoS2 cluster formation at the matrix element boundaries. This is suggestive of metal deposition limitations and/ or catalyst activation and following prohibitive of optimal catalytic utilization. These results will allow for diffusivity calculations, a better rationale of current generation catalyst performance as well as a better distribution of the active phase in next-generation hydrodesulphurization catalysts.

12.
Opt Express ; 27(25): 36637-36652, 2019 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-31873438

RESUMO

As the resolution of X-ray tomography improves, the limited long-term stability and accuracy of nanoimaging tools does not allow computing artifact-free three-dimensional (3D) reconstructions without an additional step of numerical alignment of the measured projections. However, the common iterative alignment methods are significantly more computationally demanding than a simple tomographic reconstruction of the acquired volume. Here, we address this issue and present an alignment toolkit, which exploits methods with deep-subpixel accuracy combined with a multi-resolution scheme. This leads to robust and accurate alignment with significantly reduced computational and memory requirements. The performance of the presented methods is demonstrated on simulated and measured datasets for tomography and also laminography acquisition geometries. A GPU accelerated implementation of our alignment framework is publicly available.

13.
Opt Express ; 27(10): 14981-14997, 2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31163938

RESUMO

We present a systematic study, where effects of the illumination probe design on ptychography reconstruction quality are evaluated under well-controlled conditions. The illumination probe was created using Fresnel zone-plate (FZP) optics with locally displaced zones to provide a fine control over perturbations of the illumination wavefront. We show that optimally designed wavefront modulations not only reduce bias and variance in the reconstruction of the lowest spatial frequencies but also lead to improved imaging resolution and reduction of artefacts compared to a conventional FZP. Both these factors are important for quantitative accuracy and resolution of ptychographic tomography. Our work furthers the understanding of the important characteristics of an optimal illumination for high-resolution X-ray ptychography and how to design optimal FZP wavefront modulations for different applications of ptychographic imaging. These findings are applicable and relevant for ptychography using optical, EUV, and X-ray photons as well as electrons.

14.
Opt Lett ; 44(9): 2181-2184, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31042178

RESUMO

Advances in imaging systems and modeling allow for depth information to be retrieved from projections via virtual sectioning of the imaged object. Here we introduce a regridding method that explicitly and directly incorporates this information into a general and non-iterative tomographic reconstruction algorithm. The method is applicable to any imaging scheme that provides depth-resolved projections. Additionally, we show, via numerical simulations, that with this method the required number of projections for adequate angular sampling can be reduced.

15.
Opt Express ; 26(3): 3108-3123, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29401843

RESUMO

Although ptychography does not require a precise knowledge of the illumination wavefront, common implementations rely upon assumptions such as accurate knowledge of the scan positions and constant illumination. Limited validity of these assumptions results in deterioration of the reconstruction quality. We present a generalized ptychography method that optimizes the reconstruction along multiple directions. In our manuscript, we demonstrate that the additional flexibility not only helps to amend imprecisions of the ptychography model in a self-consistent way but additionally leads to faster convergence without a significant increase of the computational cost per iteration.

16.
Opt Express ; 26(10): 12585-12593, 2018 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-29801297

RESUMO

Ptychography is a coherent diffractive imaging method that can provide a diffraction-limited, robust reconstruction of the sample's complex transmission function without the use of high-quality optics. However, the scanning nature of conventional X-ray ptychography unavoidably requires the mechanical motion of either the illumination probe or the sample. In order to avoid overhead related to breaking and acceleration for every scan position, so-called fly-scan methods were developed. Here, we present an improved variant that removes the limitation of continuous scanning along a linear scanning path and allows for ptychographic reconstruction of scans taken along an arbitrary 2D continuous trajectory. We also demonstrate numerically and experimentally that our method provides significantly improved robustness against noise, particularly for larger fly-scan steps, i.e. sample shift during an exposure, which will gain importance with the advent of 4th generation synchrotron sources, where the available coherent flux may be increased by orders of magnitude. Finally, we show that the use of a spiral scan continuous trajectory alleviates significantly raster grid artifacts.

17.
J Struct Biol ; 199(3): 209-215, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28760694

RESUMO

Collagen is the most prominent protein in biological tissues. Tissue fixation is often required for preservation or sectioning of the tissue. This may affect collagen nanostructure and potentially provide incorrect information when analyzed after fixation. We aimed to unravel the effect of 1) ethanol and formalin fixation and 2) 24h air-dehydration on the organization and structure of collagen fibers at the nano-scale using small and wide angle X-ray scattering. Samples were divided into 4 groups: ethanol fixed, formalin fixed, and two untreated sample groups. Samples were allowed to air-dehydrate in handmade Kapton pockets during the measurements (24h) except for one untreated group. Ethanol fixation affected the collagen organization and nanostructure substantially and during 24h of dehydration dramatic changes were evident. Formalin fixation had minor effects on the collagen organization but after 12h of air-dehydration the spatial variation increased substantially, not evident in the untreated samples. Generally, collagen shrinkage and loss of alignment was evident in all samples during 24h of dehydration but the changes were subtle in all groups except the ethanol fixed samples. This study shows that tissue fixation needs to be chosen carefully in order to preserve the features of interest in the tissue.


Assuntos
Tendão do Calcâneo/ultraestrutura , Colágeno/ultraestrutura , Fixação de Tecidos/métodos , Tendão do Calcâneo/química , Animais , Colágeno/química , Desidratação , Etanol/química , Feminino , Formaldeído/química , Nanoestruturas/ultraestrutura , Ratos Sprague-Dawley , Espalhamento a Baixo Ângulo , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
18.
Opt Express ; 25(18): 21145-21158, 2017 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-29041521

RESUMO

High-efficiency microfocusing of multi-keV X-rays at synchrotron sources is highly profitable for spatially resolved structural analysis of many kinds. Because radiation from synchrotron sources is typically elongated along the horizontal dimension, generating a microbeam that is isotropic in size requires a carefully designed optics system. Here we report on using a combination of a horizontally tunable slit downstream of the undulator source with elliptical diffractive Fresnel zone plates. We demonstrate the arrangement in context of small-angle X-ray scattering experiments, obtaining a microbeam of 2.2 µm × 1.8 µm (X × Y) with a flux of 1.2 × 1010 photons/s at an energy of 11.2 keV at the sample position.

19.
J Struct Biol ; 194(1): 124-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26853498

RESUMO

Sponge glass spicules have solicited great interest due to their mechanical and optical properties. Herein we use ptychographic nanotomography to obtain detailed insights into the internal structure of an anchor spicule from the Venus flower basket. The obtained dataset has 90nm resolution in 3D and provides quantitative determination of the electron density. The data reveal significant variations in electron density across the spicule. The central organic filament is found to be slightly but significantly displaced from the spicule central axis. Analysis of the electron density affords an estimate of a protein volume fraction in the organic filament of about 70%. In the highly mineralized part of the spicule, the electron density is seen to display circular symmetry and be neigh independent of position along the spicule long axis. Variations in the electron density beyond those included in current models of spicule mechanics are observed.


Assuntos
Vidro/química , Poríferos/química , Dióxido de Silício/química , Microtomografia por Raio-X/métodos , Animais , Diagnóstico por Imagem/métodos , Imageamento Tridimensional/métodos , Microscopia Eletrônica de Varredura , Poríferos/ultraestrutura
20.
J Struct Biol ; 195(3): 337-344, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27417019

RESUMO

The macro- and micro-features of bone can be assessed by using imaging methods. However, nano- and molecular features require more detailed characterization, such as use of e.g., vibrational spectroscopy and X-ray scattering. Nano- and molecular features also affect the mechanical competence of bone tissue. The aim of the present study was to reveal the effects of mineralization and its alterations on the mineral crystal scale, by investigating the spatial variation of molecular composition and mineral crystal structure across the cross-section of femur diaphyses in young rats, and healthy and osteoporotic mature rats (N=5). Fourier transform infrared spectroscopy and scanning small- and wide-angle X-ray scattering (SAXS/WAXS) techniques with high spatial resolution were used at identical locations over the whole cross-section. This allowed quantification of point-by-point information about the spatial distribution of mineral crystal volume. All measured parameters (crystal dimensions, degree of orientation and predominant orientation) varied across the cortex. Specifically, the crystal dimensions were lower in the central cortex than in the endosteal and periosteal regions. Mineral crystal orientation followed the cortical circumference in the periosteal and endosteal regions, but was less well-oriented in the central regions. Central cortex is formed rapidly during development through endochondral ossification. Since rats possess no osteonal remodeling, this bone remains (until old age). Significant linear correlations were observed between the dimensional and organizational parameters, e.g., between crystal length and degree of orientation (R(2)=0.83, p<0.001). Application of SAXS/WAXS provides valuable information on bone nanostructure and its constituents, effects of diseases and, prospectively, mechanical competence.


Assuntos
Fêmur/ultraestrutura , Animais , Densidade Óssea , Feminino , Ratos Sprague-Dawley , Espalhamento a Baixo Ângulo , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa