Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 4035-4042, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37191693

RESUMO

PURPOSE: To biomechanically compare the initial fixation strength of grafts among three tibial tunnel angles (30°/45°/60°) in transtibial posterior cruciate ligament (PCL) reconstruction. METHODS: A series of transtibial PCL reconstruction models were established with porcine tibias and bovine tendons. Specimens were randomly assigned to three groups according to the angles between the tibial tunnel and the perpendicular line of the tibial shaft: Group A (30°, n = 12), Group B (45°, n = 12), and Group C (60°, n = 12). The area of the tunnel entrance, the segmental bone mineral density (sBMD) of the graft fixation site of the tibia and the maximum insertion torque of the interference screw were measured. Finally, load to failure tests were carried out on the graft-screw-tibia constructs at the same rate. RESULTS: Ultimate load to failure in Group C (335.2 ± 107.5 N) was significantly lower than that in Group A (584.1 ± 127.9 N, P < 0.01) and Group B (521.9 ± 95.9 N, P < 0.01). There were no significant differences between biomechanical properties of Groups A and B (n.s.). The posterior part fractures of the tibial tunnel exit occurred in eight specimens of Group C. In addition, the ultimate load was proven to be related to insertion torque (rho = 0.7, P < 0.01), sBMD (rho = 0.7, P < 0.01), and the area of the tunnel entrance (rho =- 0.4, P = 0.01). CONCLUSION: The ultimate load to failure was significantly lower in tibial PCL interference screw fixation for tunnels drilled at 60° compared to 30°/45°. In addition, the ultimate load was significantly correlated with insertion torque, sBMD and the area of the tunnel entrance. Given that the load to failure of distal fixation may not be sufficient for early postoperative rehabilitation, a 60° tunnel should not be recommended to drill in tibia during PCL reconstruction.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Posterior , Animais , Bovinos , Fenômenos Biomecânicos , Parafusos Ósseos , Ligamento Cruzado Posterior/cirurgia , Suínos , Tíbia/cirurgia
2.
J Cell Biochem ; 120(9): 14986-14994, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31026097

RESUMO

α-Mangostin (α-M) is a commonly used traditional medicine with various biological and pharmacological activities. Our study aimed to explore the effects and mechanism of α-M in regulating apoptosis of rheumatoid arthritis fibroblast-like synoviocytes (RA-FLS). α-M of 10 to 100 µM was used to treat RA-FLS for 24 hours, followed by measuring cell viability and apoptosis. The involvement of reactive oxygen species (ROS) and mitogen-activated protein kinases was detected. Treatment of α-M promoted apoptosis and reduced viability of RA-FLS in a dose-dependent manner. The mitochondrial membrane potential in RA-FLS was remarkably reduced by α-M treatment, accompanied by the cytochrome c accumulation in the cytosol and increased activities of caspase-3 and caspase-9. Moreover, we found that α-M treatment promoted ROS production and extracellular signal-regulated kinase 1/2 (ERK1/2) phosphorylation. The proapoptotic activity of α-M in RA-FLS was markedly reversed by the co-induction with the ERK1/2 inhibitor LY3214996 or ROS scavenger N-acetyl-l-cysteine. In conclusion, our studies found that α-M had remarkable proapoptotic activities in RA-FLS, which is regulated by the induction of ROS accumulation and ERK1/2 phosphorylation. α-M may thus have potential therapeutic effects for rheumatoid arthritis.


Assuntos
Apoptose/efeitos dos fármacos , Artrite Reumatoide/tratamento farmacológico , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Inibidores de Proteínas Quinases/farmacologia , Sinoviócitos/metabolismo , Xantonas/farmacologia , Acetilcisteína/farmacologia , Idoso , Artrite Reumatoide/metabolismo , Benzamidas/farmacologia , Caspase 3/metabolismo , Caspase 9/metabolismo , Sobrevivência Celular/efeitos dos fármacos , Citocromos c/metabolismo , Feminino , Humanos , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Pessoa de Meia-Idade , Proteína Quinase 1 Ativada por Mitógeno/metabolismo , Proteína Quinase 3 Ativada por Mitógeno/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Sulfonamidas/farmacologia
3.
BMC Musculoskelet Disord ; 17(1): 384, 2016 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-27595993

RESUMO

BACKGROUND: Consistent reference data used for anatomic posterior cruciate ligament (PCL) reconstruction is not well defined. Quantitative guidelines defining the location of PCL attachment would aid in performing anatomic PCL reconstruction. The purpose was to characterize anatomic parameters of the PCL tibial attachment based on magnetic resonance imaging (MRI) in a large population of adult knees. METHODS: The PCL tibial attachment site was examined in 736 adult knees with an intact PCL using 3.0-T proton density-weighted sagittal MRI. The outcomes measured were the anterior-posterior diameter (APD) of the tibial plateau; angle between the tibial plateau and the posterior tibial 'shelf' (the slope where the PCL tibial attachment site was) (PTS); length of the PTS; proximal, central, and distal PCL attachment positions as well as the width of the PCL attachment site; and vertical dimension of the PCL attachment site inferior from the tibial plateau. RESULTS: The average APD of the tibia plateau was 33.6 ± 3.5 mm, yielding significant differences between males (35.5 ± 3.0 mm) and females (31.6 ± 2.7 mm), P <.05, and there was a significantly decreasing trend with increasing age in males (P <.05). Mean angle between the tibial plateau and the PTS was 122.4° ± 8.1°, and subgroup analysis showed that the young group had a differently smaller angle (120.9° ± 7.5°) than the middle-aged (123.7° ± 8.2°) and the old (123.4° ± 7.7°) in males population, while there were no significant differences between sexes (P >.05). The proximal, central positions and width of the PCL attachment site were 13.4 ± 3.0 mm, 17.8 ± 3.0 mm and 9.6 ± 2.4 mm along the PTS, with significant differences between males and females (P <.05), and accounted for 60.0 % ± 9.1 %, 80.0 % ± 4.6 % and 43.3 % ± 9.7 % of the PTS respectively, with no significant differences between sexes and among age groups (all P >.05). CONCLUSIONS: This study provides reference data of the tibial PCL attachment based on MRI in the sagittal orientation. In analysis of retrospective data from a large population of adult patients, the quantitative values can be used as references to define the inserted angle and depth of the drill guide, and the exact position and size of the tibial PCL tunnel for performing arthroscopic anatomic PCL reconstruction.


Assuntos
Ligamento Cruzado Posterior/diagnóstico por imagem , Adolescente , Adulto , Idoso , Artroscopia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/anatomia & histologia , Ligamento Cruzado Posterior/cirurgia , Valores de Referência , Adulto Jovem
4.
Quant Imaging Med Surg ; 13(8): 5195-5206, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37581068

RESUMO

Background: The graft bending angle created by the graft and the tibial tunnel has inevitably occurred during the transtibial posterior cruciate ligament (PCL) reconstruction. However, few studies quantitively analyzed this angle. This study aimed to (I) explore the optimal tibial tunnel placement to maximize the graft bending angle in the PCL reconstruction; (II) reveal the effect of the tibial tunnel placement on the graft bending angle. Methods: This was an in-vitro surgical simulation study based on the three-dimensional (3D) computed tomography (CT). A total of 55 patients who took CT scanning for knee injuries were selected (April 2020 to January 2022) from the local hospital database for review. The 3D knee models were established on the Mimics software based on the knees' CT data. Using the Rhinoceros software to simulate the transtibial PCL reconstruction on the 3D CT knee model. The anteromedial and anterolateral tibial tunnel approaches were simulated with different tibial tunnel angle. The graft bending angle and tibial tunnel length (TTL) with different tibial tunnel angles were quantitively analyzed. Results: The graft bending angle in anterolateral approach with a 50° tibial tunnel angle was significantly greater than it in anteromedial approach with a 60° tibial tunnel angle (P<0.001). There was no difference of the graft bending angle between the anterolateral approach with a 40° tibial tunnel angle and the anteromedial approach with a 60° tibial tunnel angle (P>0.05). The graft bending angle showed a strong correlation with the tibial tunnel angle (for anteromedial approach: r=0.759, P<0.001; for anterolateral approach: r=0.702, P<0.001). The best-fit equation to calculate the graft bending angle based on the tibial tunnel angle was Y = 0.89*X + 59.05 in anteromedial tibial tunnel approach (r2=0.576), and was Y = 0.78*X + 80.21 anterolateral tibial tunnel approach (r2=0.493). Conclusions: The graft bending angle and TTL will significantly increase as the tibial tunnel angle becomes greater. Maximizing the tibial tunnel angle (50° tibial tunnel angle) in the anterolateral approach could provide the greatest graft bending angle in the PCL reconstruction. No matter how the tibial tunnel angle is changed in the anteromedial approach, using anterolateral approach might reduce the killer turn effect more effectively than using anteromedial approach.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa