Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Neuromuscul Dis ; 11(3): 701-714, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640165

RESUMO

Background: Stride Velocity 95th Centile (SV95C) is the first wearable device-derived clinical outcome assessment (COA) to receive European Medicines Agency (EMA) qualification as a primary endpoint in ambulant patients with Duchenne muscular dystrophy (DMD) aged ≥4 years. Objective: To compare SV95C-in its first-ever clinical trial application as a secondary endpoint-with established motor function COAs used in the trial (Four-Stair Climb [4SC] velocity, North Star Ambulatory Assessment [NSAA], and Six-Minute Walk Distance [6MWD]). Methods: SV95C was a secondary endpoint in a subset (n = 47) of participants in the SPITFIRE/WN40227 trial of taldefgrobep alfa, which was discontinued due to lack of clinical benefit. Participants in the ≤48-week SV95C sub-study were 6-11 years old and received corticosteroids for ≥6 months pre-treatment. Pearson correlations were used to compare SV95C with the other COAs. Responsiveness and changes over time were respectively assessed via standardized response means (SRMs) based on absolute changes and mixed models for repeated measures. Results: SV95C change at Week 24 was -0.07 m/s, with limited variability (standard deviation: 0.16, n = 27). The SRM for SV95C indicated moderate responsiveness to clinical change at the earliest timepoint (Week 12, n = 46), while those of the other COAs did not indicate moderate responsiveness until Week 36 (6MWD, n = 33) or Week 48 (4SC velocity, n = 20; NSAA total score, n = 20). Baseline correlations between SV95C and other COAs were strong (r = 0.611-0.695). Correlations between SV95C change from baseline to Week 48 and changes in other COAs were moderate to strong (r = 0.443-0.678).∥. Conclusions: Overall, SV95C demonstrated sensitivity to ambulatory decline over short intervals, low variability, and correlation with established COAs. Although the negative trial precluded demonstration of SV95C's sensitivity to drug effect, these findings support the continued use of SV95C in DMD clinical trials.


Assuntos
Distrofia Muscular de Duchenne , Teste de Caminhada , Caminhada , Humanos , Distrofia Muscular de Duchenne/fisiopatologia , Distrofia Muscular de Duchenne/tratamento farmacológico , Criança , Masculino , Caminhada/fisiologia , Avaliação de Resultados em Cuidados de Saúde , Dispositivos Eletrônicos Vestíveis , Feminino
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa