Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Radiol Prot ; 40(1): 243-252, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31499482

RESUMO

PURPOSE: Recently new mobile systems for dispensing positron emitters have been produced, designed to guarantee dispensing cycles in an aseptic environment. The aim of the present work was to assess the advantage of one of these systems in radiation protection of operators in clinical settings. METHODS: Recently, in our centre the new self-dispensing system named KARL100 by Tema Sinergie was adopted for 18F-FDG radiopharmaceuticals. The system is associated with an automatic Rad-inject infuser. The system that was previously used was a fixed isolator NMC DSI (Tema Sinergie), equipped with a µDDS-An activity fractioning system, together with a pneumatic post for the syringe delivery. The dosimetric evaluations on both systems were carried out through environmental measurements with an ionisation chamber and with the use of personal dosimeters. RESULTS: The operations of preparation and administration of 18F-FDG dose to the patient, with the use of Karl100 + RadInject, involve exposures much lower than those obtained by the fixed isolator. The average body exposure of the technician was reduced by 31%, and for the physician by 77%. On the extremities, the equivalent dose to the hands of the technician was reduced by 78%, and for the physician by 96%. Also the additional dosimeters worn by the technician confirmed the estimated environmental assessments. CONCLUSIONS: The exposures of the working personnel were significantly reduced with the introduction of the new KARL100 system.


Assuntos
Fluordesoxiglucose F18/administração & dosagem , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/métodos , Radiometria/instrumentação , Compostos Radiofarmacêuticos/administração & dosagem , Humanos , Doses de Radiação
2.
Phys Med Biol ; 63(23): 235010, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30474620

RESUMO

State of the art point-spread function (PSF) corrections implemented in positron emission tomography/computed tomography (PET/CT) reconstruction improved image quality and diagnostic performance but caused an increase in the standardized uptake value (SUV) compared to a conventional OSEM reconstruction system. The EANM suggested one produce two reconstructions, one optimised for maximum lesion detection and one for semi-quantitative analysis. In this work we investigated an alternative methodology, using a single reconstruction data set together with a post-reconstruction algorithm for SUV harmonization. Data acquisition was performed on a Siemens Biograph mCT system equipped with lutetium oxyorthosilicat crystals, PSF and time-of-flight algorithms and on a General Electric Discovery STE system equipped with BGO crystals. Both a EANM double reconstruction method and a dedicated post-reconstruction algorithm (marketed as EQ-filter) were tested to harmonize the quantitative values of the two PET/CT scanners. For phantom measurements we used a NEMA IQ phantom and a Jaszczak cylindrical phantom equipped with small spheres (lesion to background ratios of 8:1 and 4:1). Several different reconstruction settings were tested in order to provide a general methodology. Data obtained by phantom measurements were validated on seven oncologic patients who performed a one-bed extra acquisition on a different scanner. The evaluation regarded 39 small lesions (diameters: 0.3-2.6 cm) and was performed by two experienced nuclear medicine physicians. The SUV recoveries measured with the PSF reconstruction exceeded those obtained by the OSEM reconstruction with deviations ranging from 16% to 150%. These discrepancies resulted below 7% applying the optimized value of the EQ.filter or the double-reconstruction methods. For each reconstruction setting the optimal value of the EQ.filter was identified in order to minimize these discrepancies. Patient data, analyzed by Wilcoxon statistical test, confirmed and validated phantom measurements. EQ.filter can harmonize SUV values between different PET/CT scanners using a single reconstruction optimized to maximum lesion detectability. In this way, the second reconstruction proposed by EANM/EARL is avoided.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Calibragem , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa