Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Magn Reson Med ; 79(3): 1674-1683, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28626964

RESUMO

PURPOSE: Bayesian model fitting has been proposed as a robust alternative for intravoxel incoherent motion (IVIM) model-fitting parameter estimation. However, consensus regarding choice of prior distribution and posterior distribution central tendency measure is needed. The aim of this study was to compare the quality of IVIM parameter estimates produced by different prior distributions and central tendency measures, and to gain knowledge about the effect of these choices. METHODS: Three prior distributions (uniform, reciprocal, and lognormal) and two measures of central tendency (mean and mode) found in the literature were studied using simulations and in vivo data from a tumor mouse model. RESULTS: Simulations showed that the uniform and lognormal priors were superior to the reciprocal prior, especially for the parameters D and f and clinically relevant SNR levels. The choice of central tendency measure had less effect on the results, but had some effects on estimation bias. Results based on simulations and in vivo data agreed well, indicating high validity of the simulations. CONCLUSIONS: Choice of prior distribution and central tendency measure affects the results of Bayesian IVIM parameter estimates. This must be considered when comparing results from different studies. The best overall quality of IVIM parameter estimates was obtained using the lognormal prior. Magn Reson Med 79:1674-1683, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Teorema de Bayes , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Animais , Simulação por Computador , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Movimento/fisiologia , Neoplasias Experimentais , Razão Sinal-Ruído
2.
J Arthroplasty ; 33(3): 815-822, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29153632

RESUMO

BACKGROUND: Treatment of acetabular bone loss with impaction bone grafting (IBG) at revision total hip arthroplasty is highly dependent on mechanical stability and graft compression for clinical success. Here, we describe a new technique to further compress and stabilize the acetabular graft bed with a thin, perforated titanium shell. METHODS: We retrospectively analyzed 170 cases of acetabular revision arthroplasty 7 years (standard deviation 2.8) after IBG combined with a graft-compressing titanium shell implant. The patients were reviewed by clinical score and radiography. Three patients were lost to follow-up. The medical journals of the 33 deceased cases were reviewed for any reoperation. Of the 170 cases, 74 had a cavitary acetabular bone defect, 93 had combined segmental and cavitary bone defects, and 3 had a pelvic dissociation. Bone graft incorporation was assessed and correction of the hip center of rotation was calculated. RESULTS: Five cases (3%) were reoperated for mechanical loosening. One more was assessed as loose but asymptomatic and was not planned for revision. There were 3 reoperations for recurrent dislocation, 2 for deep infection and 1 for technical error. Reoperation for any reason, as the end point of survivorship, showed a survival rate of 92% after 10 years. Hip score according to Merle, d'Aubigne, and Postel increased from 10.8 (preoperatively) to 16.4 at follow-up. The clinical and radiological results were excellent. CONCLUSION: IBG combined with the compressing shell results in excellent results for this challenging condition.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Cimentos Ósseos , Transplante Ósseo , Prótese de Quadril , Reoperação/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aloenxertos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Rotação , Resultado do Tratamento
3.
BMC Med Imaging ; 16(1): 42, 2016 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-27400959

RESUMO

BACKGROUND: To extract DTI parameters from a specific structure, a region of interest (ROI) must be defined. ROI selection in small structures is challenging; the final measurement results could be affected due to the significant impact of small geometrical errors. In this study the optic tracts were analyzed with the aim to assess differences in DTI parameters due to ROI method and to identify the most reliable method. METHODS: Images of 20 healthy subjects were acquired. Fractional anisotropy (FA) was extracted from the optic tracts by four different ROI methods. Manual tracing was performed in 1) the b0 image and 2) a T1-weighted image registered to the FA image. Semi-automatic segmentation was performed based on 3) tractography and 4) the FA-skeleton algorithm in the tract-based spatial statistics (TBSS) framework. Results were analyzed with regard to ROI method as well as to inter-scan, intra-rater and inter-rater reliability. RESULTS: The resulting FA values divided the ROI methods into two groups that differed significantly: 1) the FA-skeleton and the b0 methods showed higher FA values compared to 2) the tractography and the T1-weighted methods. The intra- and inter-rater variabilities were similar for all methods, except for the tractography method where the inter-rater variability was higher. The FA-skeleton method had a better reproducibility than the other methods. CONCLUSION: Choice of ROI method was found to be highly influential on FA values when the optic tracts were analyzed. The FA-skeleton method performed the best, yielding low variability and high repeatability.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Processamento de Imagem Assistida por Computador/métodos , Trato Óptico/diagnóstico por imagem , Adulto , Algoritmos , Anisotropia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
4.
Opt Express ; 20(19): 21264-71, 2012 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-23037249

RESUMO

InSb-based quantum dots grown by metal-organic vapor-phase epitaxy (MOVPE) on InAs substrates are studied for use as the active material in interband photon detectors. Long-wavelength infrared (LWIR) photoluminescence is demonstrated with peak emission at 8.5 µm and photoresponse, interpreted to originate from type-II interband transitions in a p-i-n photodiode, was measured up to 6 µm, both at 80 K. The possibilities and benefits of operation in the LWIR range (8-12 µm) are discussed and the results suggest that InSb-based quantum dot structures can be suitable candidates for photon detection in the LWIR regime.

5.
J Neurosurg ; 127(3): 569-579, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27885957

RESUMO

OBJECTIVE Despite ample experience in surgical treatment of pituitary adenomas, little is known about objective indices that may reveal risk of visual impairment caused by tumor growth that leads to compression of the anterior visual pathways. This study aimed to explore diffusion tensor imaging (DTI) as a means for objective assessment of injury to the anterior visual pathways caused by pituitary adenomas. METHODS Twenty-three patients with pituitary adenomas, scheduled for transsphenoidal tumor resection, and 20 healthy control subjects were included in the study. A minimum suprasellar tumor extension of Grade 2-4, according to the SIPAP (suprasellar, infrasellar, parasellar, anterior, and posterior) scale, was required for inclusion. Neuroophthalmological examinations, conventional MRI, and DTI were completed in all subjects and were repeated 6 months after surgery. Quantitative assessment of chiasmal lift, visual field defect (VFD), and DTI parameters from the optic tracts was performed. Linear correlations, group comparisons, and prediction models were done in controls and patients. RESULTS Both the degree of VFD and chiasmal lift were significantly correlated with the radial diffusivity (r = 0.55, p < 0.05 and r = 0.48, p < 0.05, respectively) and the fractional anisotropy (r = -0.58, p < 0.05 and r = -0.47, p < 0.05, respectively) but not with the axial diffusivity. The axial diffusivity differed significantly between controls and patients with VFD, both before and after surgery (p < 0.05); however, no difference was found between patients with and without VFD. Based on the axial diffusivity and fractional anisotropy, a prediction model classified all patients with VFD correctly (sensitivity 1.0), 9 of 12 patients without VFD correctly (sensitivity 0.75), and 17 of 20 controls as controls (specificity 0.85). CONCLUSIONS DTI could detect pathology and degree of injury in the anterior visual pathways that were compressed by pituitary adenomas. The correlation between radial diffusivity and visual impairment may reflect a gradual demyelination in the visual pathways caused by an increased tumor effect. The low level of axial diffusivity found in the patient group may represent early atrophy in the visual pathways, detectable on DTI but not by conventional methods. DTI may provide objective data, detect early signs of injury, and be an additional diagnostic tool for determining indication for surgery in cases of pituitary adenomas.


Assuntos
Adenoma , Neoplasias Hipofisárias , Substância Branca , Anisotropia , Imagem de Tensor de Difusão , Humanos , Vias Visuais
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa