Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Semin Nucl Med ; 37(6): 420-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17920349

RESUMO

The choline transporter and choline kinase enzyme frequently are overexpressed in malignancy. Therefore, positron-emitter-labeled compounds derived from choline have the potential to serve as oncologic probes for positron emission tomography. The fluorine-18 ((18)F)-labeled choline derivative fluorocholine (FCH) in particular has demonstrated potential utility for imaging of a variety of neoplasms, including those of the breast, prostate, liver, and brain. The pharmacokinetics of FCH and other choline tracers allow for whole-body imaging within minutes of injection while still achieving high tumor-to-background contrast in most organs, including the brain. These features, along with the possibility of imaging malignancies that have proved elusive with the use of (18)F-fluorodeoxyglucose positron emission tomography support further clinical investigations of (18)F-labeled choline tracers.


Assuntos
Colina/análogos & derivados , Neoplasias/diagnóstico por imagem , Compostos Radiofarmacêuticos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/metabolismo , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/metabolismo , Colina/farmacocinética , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/metabolismo , Feminino , Radioisótopos de Flúor , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Masculino , Neoplasias Nasofaríngeas/diagnóstico por imagem , Neoplasias Nasofaríngeas/metabolismo , Neoplasias/metabolismo , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Compostos Radiofarmacêuticos/farmacocinética
2.
Presse Med ; 36(12 Pt 2): 1794-806, 2007 Dec.
Artigo em Francês | MEDLINE | ID: mdl-17524607

RESUMO

In prostate cancer, use of FDG, the radiopharmaceutical currently most widely used in oncology, is limited to the most aggressive cancers and, in the absence of another tracer, to attempting to localise occult recurrences detected biochemically (elevated PSA serum levels). Four other PET tracers are currently suggested in various situations of prostate cancer development: for guiding biopsies, for diagnosis and staging of the primary cancer and of local or metastatic recurrences, especially in bone, and for localizing occult biochemical recurrence. This article is illustrated by cases summarising our experience with fluoromethylcholine-(18F) and PET/CT. They cover a wide spectrum of clinical settings: localisation of intraprostatic neoplastic lesions, initial staging, monitoring treatment by ultrasound, detection of occult recurrences and characterisation of images on conventional imaging modalities, which are questionable or difficult to interpret.


Assuntos
Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Colina/análogos & derivados , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Humanos , Masculino , Recidiva Local de Neoplasia/diagnóstico por imagem , Estadiamento de Neoplasias , Neoplasias da Próstata/patologia , Compostos Radiofarmacêuticos
3.
J Nucl Med ; 47(9): 1455-62, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16954553

RESUMO

UNLABELLED: The aim of this study was to evaluate whether (18)F-fluorodihydroxyphenylalanine ((18)F-FDOPA) PET is accurate for the diagnosis and follow-up of any type of well-differentiated digestive endocrine tumor and to assess its performance compared with standard somatostatin receptor scintigraphy (SRS) using (111)In-pentetreotide. METHODS: We reviewed the results of 33 evaluable (18)F-FDOPA PET and (111)In-pentetreotide SRS examinations performed between March 2002 and September 2005 in 30 patients referred for documented well-differentiated digestive endocrine tumor. RESULTS: The sensitivity and accuracy of (18)F-FDOPA PET were significantly better for carcinoid tumors (defined according to the World Health Organization 2000 classification) (n = 19) than for noncarcinoid tumors (n = 14)-that is, 93% versus 25% for sensitivity (P < 0.01) and 89% versus 36% for accuracy (P < 0.01), respectively. In contrast, the performances of (111)In-pentetreotide SRS did not differ according to the carcinoid or noncarcinoid type of the primary endocrine tumor-that is, 81% versus 75% for sensitivity and 79% versus 71% for accuracy, respectively. In carcinoid tumors, comparison between (18)F-FDOPA PET and (111)In-pentetreotide SRS showed that (18)F-FDOPA PET more accurately evaluated the extent of disease than (111)In-pentetreotide SRS. (111)In-Pentetreotide SRS did not reveal any additional lesions in any case. Conversely, in noncarcinoid tumors, the extent of the disease was more accurately evaluated in all cases by (111)In-pentetreotide SRS than by (18)F-FDOPA PET. CONCLUSION: This preliminary study emphasizes the importance of a precise histologic characterization of well-differentiated digestive endocrine tumor to select the best radiopharmaceutical. (18)F-FDOPA PET appears to be useful in carcinoid tumors and could become the first-line scintigraphic imaging modality for these tumors, but (111)In-pentetreotide SRS appeared to be a better first-line scintigraphic imaging modality for noncarcinoid digestive tumors.


Assuntos
Tumor Carcinoide/diagnóstico por imagem , Neoplasias do Sistema Digestório/diagnóstico por imagem , Di-Hidroxifenilalanina/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Somatostatina/análogos & derivados , Adulto , Idoso , Tumor Carcinoide/metabolismo , Neoplasias do Sistema Digestório/metabolismo , Di-Hidroxifenilalanina/farmacocinética , Neoplasias das Glândulas Endócrinas/diagnóstico por imagem , Neoplasias das Glândulas Endócrinas/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética , Receptores de Somatostatina/metabolismo , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Somatostatina/farmacocinética
4.
Nucl Med Commun ; 27(1): 5-9, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16340717

RESUMO

OBJECTIVES: To compare, intra-individually, the detection rates of sentinel node on lymphoscintigraphy performed on the day of injection (D0) and on the following day (D1) in breast carcinoma. We also compared 2-day and 1-day protocols in the two groups of patients. METHODS: The 2-day and 1-day protocols included 76 patients in group 1 and 23 patients in group 2. Patients from group 1 underwent lymphoscintigraphy twice--at 2 h (lymphoscintigraphy 1) and 18 h (lymphoscintigraphy 2) post-injection at four sites periareolar using 99mTc sulfur colloid. Patients from group 2 underwent lymphoscintigraphy only at 2 h post-injection. The detection rates and the number of sentinel nodes were compared in the two lymphoscintigraphy examinations for group 2. RESULTS: The detection rate on lymphoscintigraphy in group 1 was 92% at D0 and 96% at D1. The overall agreement between lymphoscintigraphy 1 and lymphoscintigraphy 2 was 69/76 (91%). In 2/76 women, the sentinel node disappeared at D1 on lymphoscintigraphy, but remained detectable during surgery, and in 5/76 women, the sentinel node appeared at D1 on lymphoscintigraphy. The mean number of sentinel nodes detected on lymphoscintigraphy was 2.05+/-0.14 at D0 and 1.76+/-0.11 at D1 (P=0.004) in group 2, the detection rate of the sentinel node was 20/23 (87%). CONCLUSION: Our study demonstrated that for patients undergoing the 2-day protocol for sentinel node procedure in early stage breast cancer, the optimal imaging time would be to perform lymphoscintigraphy 1 h after injection, with the possibility of imaging patients the following day in cases where lymphoscintigraphy was negative.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/secundário , Aumento da Imagem/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Biópsia de Linfonodo Sentinela/métodos , Coloide de Enxofre Marcado com Tecnécio Tc 99m/administração & dosagem , Neoplasias da Mama/patologia , Feminino , Humanos , Injeções , Metástase Linfática , Pessoa de Meia-Idade , Variações Dependentes do Observador , Cintilografia , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
5.
Presse Med ; 35(9 Pt 2): 1339-46, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16969330

RESUMO

FDG, a radioactive glucose analog for PET imaging, requires some precautions: it should be used only in patients with glycemia < 7mmol/L, fasting for at least 6 h but well hydrated, and after pregnancy is ruled out. FDG-PET has many indications in oncology. Its clinical utility has been documented in some circumstances, listed as routine indications in the European Principal Characteristics Summary and the French Standards, Options, and Recommendations. The European "Points to Consider" define as a principal criterion of clinical utility the impact of the imaging results on patient management. The original results presented here evaluate the clinical impact of FDG-PET among patients at Tenon Hospital by the rate of modifications in patient' management, determined with the same questionnaire as that used in two California studies of 2044 patients. Our response rate was lower than in our previous retrospective study in 2000 (34% versus 73%), probably because a prospective evaluation requires more work by the referring physician (who had to respond to two separate letters). On the other hand, the modification rate rose significantly (54% versus 46%, p<0.001), especially for colorectal cancer (58% versus 44%, p<0.02). The California studies had similar response rates (31%-48%, depending on the indication). Their modification rates were also similar, although higher for lymphoma (68%), colorectal (65%) and breast (58%) cancers.


Assuntos
Fluordesoxiglucose F18 , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomada de Decisões , Humanos
6.
Presse Med ; 35(9 Pt 2): 1347-53, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16969331

RESUMO

Normal biodistribution of FDG includes intense physiologic uptake in the brain, which consumes glucose. The high background therefore makes it difficult to detect the foci taking up glucose, which correspond to malignant lesions. FDG PET is nevertheless clinically useful for detecting high-grade gliomas, cerebral lymphomas and, in some cases, unexpected brain metastases in whole-body PET examinations. As an adjunct to CT and MRI, FDG-PET can make stereotactic radiosurgery more precise in targeting primary or secondary brain cancers and can differentiate necrotic fibrosis from viable cancer tissue during follow-up in cases of abnormal or equivocal MRI results. When available, methionine-(11C) PET delineates low grade gliomas accurately. Several fluorine (18F)-labeled radiopharmaceuticals have been proposed in this setting, with FET and FDOPA apparently the most effective. Four original clinical cases illustrating performances of FET and FDOPA PET in this setting are presented.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Colina , Didesoxinucleosídeos , Di-Hidroxifenilalanina/análogos & derivados , Fluordesoxiglucose F18 , Glioma/diagnóstico por imagem , Humanos , Metionina , Compostos Radiofarmacêuticos
7.
Presse Med ; 35(9 Pt 2): 1355-69, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16969332

RESUMO

FDG PET is useful when cancer in the head or neck (except for tumors of the salivary glands, which cannot be characterized accurately) is diagnosed or suspected but not confirmed by biopsy. It can, for example, find evidence of suspicious lymph nodes in clinically N0 necks, detect foci suggestive of distant metastases or second cancers, and provide useful prognostic information. Because it can be very difficult to identify anatomical structures and landmarks on PET images in the head and neck region, PET/CT fusion is very helpful in this area. In early assessment of chemotherapy, the absence of a significant reduction in FDG uptake after one or two cycles predicts lack of efficacy and thus indicates the need to modify the regimen. Conversely, the disappearance of FDG foci indicates effective treatment and good prognosis but cannot rule out the persistence of any malignant tissue at the end of treatment, especially neoadjuvant. Diagnostic impact is probably greatest in monitoring for recurrence and restaging known recurrence: FDG PET should be performed - perhaps routinely - early enough that curative options are still open, but long enough after the end of treatment to avoid false positive results from inflammation. The strategy and timing of FDG PET during follow-up should be determined in more detail in the future, as should the role (if any) of fluorotyrosine (FET) PET in squamous cell carcinoma.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Antineoplásicos/uso terapêutico , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Estadiamento de Neoplasias/métodos , Compostos Radiofarmacêuticos
8.
Presse Med ; 35(9 Pt 2): 1371-6, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16969333

RESUMO

FDG-PET can be successful in localizing the primary cancer when a metastasis is discovered but no primary tumor can be identified (cancer of unknown primary, or CUP) by physical examination, laboratory testing (for tumor markers, for example) or conventional imaging. The greatest number of PET studies in CUP concern secondary lesions in cervical lymph nodes, and PET is an established clinical use (highest ranking, 1A) according to the 3rd German Consensus Conference and an "option" in the French Standards, Options, and Recommendations. Success rates range from 30% to 50% in most studies using PET; a higher rate was reported recently with PET/CT. FDG-PET should be performed sufficiently early in cases of neurological paraneoplastic syndrome, because established lesions become irreversible. Identification of the antibody present helps to specify the organ and FDG-PET can then localize the lesion; together these techniques make it possible to perform curative surgery even when the primary tumor is not visible. The success rate is somewhat lower than in cases of metastasis, around 35%. The clinical utility of PET in other paraneoplastic syndromes has not yet been sufficiently studied, but these conditions are rare. It is precisely in cases with a kind of 'orphan' indication that FDG PET should be considered, as an effective "problem solver".


Assuntos
Neoplasias Primárias Desconhecidas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Fluordesoxiglucose F18 , Humanos , Síndromes Paraneoplásicas do Sistema Nervoso/diagnóstico por imagem , Compostos Radiofarmacêuticos
9.
Presse Med ; 35(9 Pt 2): 1387-400, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16969335

RESUMO

In our hospital as in many others, primary lung cancer is the most frequent indication for FDG PET. Studies have assessed the clinical utility of this imaging modality in characterizing solitary pulmonary nodules or masses, initial staging, defining tumor volume in radiotherapy and searching for recurrence of or restaging non-small cell carcinoma; studies are currently underway to evaluate its use in early assessment of chemotherapy response. Small cell lung cancer has a high FDG uptake and PET/CT can be useful for rapid staging. False negative results may be due to pure bronchioloalveolar carcinomas and endocrine tumors. FDG-PET will certainly play a more important role in the diagnosis and follow-up of pleural cancers in the future. An unexpected positive FDG PET focus should be considered as a warning, but histological proof should precede any irrevocable decisions.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pleurais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Diagnóstico Diferencial , Fluordesoxiglucose F18 , Humanos , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos
10.
Presse Med ; 35(9 Pt 2): 1377-85, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16969334

RESUMO

FDG PET can detect thyroid cancer in patients referred for exploration of a different cancer. Because of its lack of specificity, however, this modality is not indicated for examination of thyroid nodules: ultrasonography and fine needle biopsy with cytology allow histological diagnosis, which can be completed by iodine-123 scintigraphy when an autonomous nodule is suspected. No information is currently available about the utility of FDG PET in preoperative staging. In follow-up of patients undergoing thyroidectomy for adenocarcinoma, FDG PET is useful for detecting recurrence in cases where serum thyroglobulin levels rise and iodine-131 scintigraphy is negative: surgical resection may be appropriate. Nonetheless FDG PET should be performed more widely and earlier: the initial presence of foci positive for FDG is a major predictor of shorter survival, and most cancer lesions take up either iodine or FDG. In follow-up of medullary carcinoma, FDG PET detects residual tissue better than any other scintigraphic procedures, especially when serum levels of CEA (carcinoembryonic antigen) are rising rapidly. FDOPA PET seems to have better sensitivity than FDG-PET and may be useful in occult recurrence, as three case reports indicate.


Assuntos
Tomografia por Emissão de Pósitrons , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/cirurgia , Carcinoma Medular/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Compostos Radiofarmacêuticos , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia
11.
Bull Acad Natl Med ; 189(5): 963-75; discussion 975-8, 2005 May.
Artigo em Francês | MEDLINE | ID: mdl-16433466

RESUMO

Positron emission tomography (PET) is a metabolic radionuclide imaging method in which a tracer labeled with a positron emitter is detected with a dedicated system. 18F-fluorodeoxyglucose (FDG) accumulates in tumor cells because of their increased glycolytic activity, and is thus widely used as a tracer in oncology. This increased metabolic activity precedes morphologic modifications, making FDG-PET a very useful tool for detecting and staging cancer. It can also be used to characterize morphologic changes, differentiating not only between benign and malignant lesions, but also between viable tumor cells and areas of necrosis and/or fibrosis induced by treatments. Being a whole-body examination, it allows malignancies to be staged in a single procedure. Systems combining PET and CT (computed tomography) offer improved performance, providing both metabolic and anatomical data. This technique appears to be useful for initial breast cancer staging, especially of locally advanced forms and suspected recurrences (increase of isolated tumor marker). Early studies of PET evaluation of responses to hormonal and/or cytotoxic therapies have also given very promising results. However, this technique does not seem sufficiently sensitive to be included in the initial screening or diagnosis of primary tumors, owing to its limited resolution (about 5 mm) and its restricted availability. This approach is poorly sensitive when used for axillary assessment, but offers good specificity.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Neoplasias da Mama/terapia , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem
16.
J Nucl Med ; 51(11): 1699-706, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20956466

RESUMO

UNLABELLED: This prospective study aimed to compare the diagnostic performance of (18)F-fluorocholine and (18)F-FDG for detecting and staging hepatocellular carcinoma (HCC) in patients with chronic liver disease and suspected liver nodules. METHODS: Whole-body PET/CT was performed in a random order at 10 min after injection of 4 MBq of (18)F-fluorocholine per kilogram and at 1 h after injection of 5 MBq of (18)F-FDG per kilogram. PET/CT results were read in a masked manner by 2 specialists, and diagnostic performance was assessed from the results of consensus masked reading. Those focal lesions appearing with increased or decreased activity, compared with background, on (18)F-fluorocholine PET/CT were considered positive for malignancy. The standard of truth was determined on a per-site basis using data from a histologic examination and a follow-up period of more than 6 mo; on a per-patient basis, the Barcelona criteria were also accepted as a proof of HCC in 5 patients. RESULTS: Eighty-one patients were recruited; standard of truth was determined in 59 cases. HCC was diagnosed in 34 patients. Therefore, sensitivity was 88% for (18)F-fluorocholine and 68% for (18)F-FDG (P = 0.07), and in 70 sites, sensitivity was 84% for (18)F-fluorocholine, significantly better than the 67% for (18)F-FDG (P = 0.01). Of the 11 patients with well-differentiated HCC, 6 had a positive result with (18)F-fluorocholine alone, whereas (18)F-FDG was never positive alone; corresponding site-based sensitivity was 94% for (18)F-fluorocholine and 59% for (18)F-FDG (P = 0.001). The detection rate of 18 sites corresponding to other malignancies was 78% for (18)F-fluorocholine and 89% for (18)F-FDG. In nonmalignant sites, (18)F-fluorocholine appeared less specific than (18)F-FDG (62% vs. 91% P < 0.01) because of uptake by focal nodular hyperplasia. CONCLUSION: (18)F-fluorocholine was significantly more sensitive than (18)F-FDG at detecting HCC, in particular in well-differentiated forms. In contrast, (18)F-FDG appeared somewhat more sensitive at detecting other malignancies and was negative in focal nodular hyperplasia. Thus (18)F-fluorocholine appears to be a useful PET/CT tracer for the detection and surveillance of HCC; however, performing PET/CT with both radiopharmaceuticals seems to be the best option.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Colina/análogos & derivados , Fluordesoxiglucose F18 , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Transporte Biológico , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/patologia , Diferenciação Celular , Colina/metabolismo , Doença Crônica , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Estadiamento de Neoplasias , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Nucl Med Commun ; 31(5): 389-97, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20145579

RESUMO

AIM: Bronchioloalveolar (BAC) cancer is a source of false-negative F-fluorodeoxyglucose (FDG) PET/computed tomography (CT) results. A few studies reported better diagnostic performances with PET tracers of lipid metabolism, C-choline, or C-acetate, for the detection of well-differentiated adenocarcinoma or BAC. F-fluorocholine (FCH) is a lipid analogue for PET imaging, with advantages in terms of logistics and image resolution. We carried out this prospective pilot study to evaluate whether FCH PET/CT could detect lung cancer with a BAC component and could be more sensitive than FDG in this aim. METHODS: Fifteen patients with a lung nodule or lesion suspected for BAC on CT and/or with a history of BAC had PET/CT 60-90 min after 5 MBq FDG/kg body mass and, on a separate day, 10-20 min after 4 MBq FCH/kg body mass. The standard of truth was histology and a 6-month follow-up. RESULTS: Nine patients (12 lesions) presented BAC or adenocarcinoma with BAC features, two patients presented adenocarcinoma without BAC features (five lesions) and four patients presented benign lesions (15 non-malignant sites). For both FCH and FDG, patient-based sensitivity was 78% for detecting cancer with a BAC component and 82% for detecting malignancy. Site-based sensitivity for detecting malignancy was 76 and 75% for detecting cancer with BAC features, for both radiopharmaceuticals. Specificity was similar for FCH and FDG (site-based 93 vs. 81%, NS). In these early-stage cancers, only one adrenal metastasis was observed that took up FCH and FDG. CONCLUSION: In this population of patients with ground-glass opacities selected on CT suggestive of BAC or with a history of BAC and a recent lung anomaly on CT, FCH detected all malignant lesions with at least a 2.0 cm short axis. However, FDG had similar performance.


Assuntos
Adenocarcinoma Bronquioloalveolar/diagnóstico por imagem , Colina/análogos & derivados , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma Bronquioloalveolar/metabolismo , Idoso , Idoso de 80 Anos ou mais , Transporte Biológico , Colina/metabolismo , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
18.
Presse Med ; 37(2 Pt 2): e1-e24, 2008 Feb.
Artigo em Francês | MEDLINE | ID: mdl-17951024

RESUMO

In digestive oncology, the most frequent indication for FDG PET, in our experience and as reported in the literature, is the localisation of recurrent colorectal cancer. This molecular imaging method has also been shown to be clinically useful in various other settings, especially for preoperative staging, for colorectal, esophageal, gastric, pancreatic, hepatic and biliary cancers. We also report on current PET practice in two particular cancers: hepatocellular carcinoma, for which other tracers, including fluoromethylcholine-(18F), are being currently evaluated, and gastrointestinal endocrine tumours, which are included in the recent French marketing authorisation of fluoroDOPA-(18F) and which are also potential targets for radiolabelled somatostatin analogues for PET imaging.


Assuntos
Neoplasias do Sistema Digestório/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Neoplasias do Sistema Digestório/patologia , Neoplasias do Sistema Digestório/terapia , Fluordesoxiglucose F18 , Humanos , Recidiva Local de Neoplasia/diagnóstico , Estadiamento de Neoplasias , Prognóstico , Compostos Radiofarmacêuticos
19.
Eur J Nucl Med Mol Imaging ; 33(11): 1285-9, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16802155

RESUMO

PURPOSE: The diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG) PET is insufficient to characterise hepatocellular carcinoma (HCC) in liver masses and to diagnose all cases of recurrent HCC. HCC has been reported to take up [(11)C]acetate, but routine use of this tracer is difficult. Choline is another tracer of lipid metabolism, present in large amounts in HCC. In a proof-of-concept study, we evaluated [(18)F]fluorocholine (FCH) uptake by HCC and compared FCH PET/CT with FDG PET/CT. METHODS: Twelve patients with newly diagnosed (n=8) or recurrent HCC (n=4) were prospectively enrolled. HCC was assessed by histology in eight cases and by American Association for the Study of Liver Diseases (AASLD) criteria in four cases. All patients underwent whole-body PET/CT 10 min after injection of 4 MBq/kg FCH. Within 1 week, 9 of the 12 patients also underwent whole-body FDG PET/CT 1 h after injection of 5 MBq/kg FDG. RESULTS: The per-patient analysis showed a detection rate of 12/12 using FCH PET/CT for both newly diagnosed and recurrent HCC. The median signal to noise ratio was 1.5+/-0.38. There was a trend towards a higher FCH SUV(max) in well-differentiated HCC (15.6+/-7.9 vs 11.9+/-0.9, NS). Of the nine patients who underwent FCH and FDG PET/CT, all nine were positive with FCH whereas only five were positive with FDG. CONCLUSION: FCH provides a high detection rate for HCC, making it potentially useful in the initial evaluation of HCC or in the detection of recurrent disease. The favourable result of this proof-of-concept study opens the way to a phase III prospective study.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Colina/análogos & derivados , Fluordesoxiglucose F18 , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
20.
AJR Am J Roentgenol ; 185(6): 1516-24, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16304006

RESUMO

OBJECTIVE: The objective of our study was to evaluate a rigid registration method in lung perfusion SPECT using thoracic CT as a standard. MATERIALS AND METHODS: The reproducibility of markers selection and the robustness of the method were assessed on a torso phantom. The accuracy of registration regarding the number and location of markers and the breathing state during CT was evaluated on eight patients using 10 external markers placed around the thorax before SPECT and CT acquisitions. The accuracy of registration was assessed using the mean errors (ME) between 10 markers after registration. RESULTS: Registration using external markers on a phantom was accurate (ME, < 3 mm) when rotation was less than 40 degrees (p = 0.02). The accuracy of registration improved markedly from four to six markers for phantom (5.5-3.6 mm) and patients (11.2-9.5 mm) and then remained constant up to 10 markers. The ME was less when using markers that well encompassed the thorax for phantom and patients (p = 0.02 and p = 0.05, respectively). The use of four anatomic markers was not accurate (ME, 20 mm). CONCLUSION: The registration method is reproducible and accurate, and six external markers were required to get an ME of less than 10 mm in patients.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Idoso , Análise de Variância , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Postura , Radiografia Torácica/instrumentação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa