Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Anaesthesiol ; 38(12): 1242-1252, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34155171

RESUMO

BACKGROUND: Cardiac output (CO) monitoring is the basis of goal-directed treatment for major abdominal surgery. A capnodynamic method estimating cardiac output (COEPBF) by continuously calculating nonshunted pulmonary blood flow has previously shown good agreement and trending ability when evaluated in mechanically ventilated pigs. OBJECTIVES: To compare the performance of the capnodynamic method of CO monitoring with transpulmonary thermodilution (COTPTD) in patients undergoing major abdominal surgery. DESIGN: Prospective, observational, method comparison study. Simultaneous measurements of COEPBF and COTPTD were performed before incision at baseline and before and after increased (+10 cmH2O) positive end-expiratory pressure (PEEP), activation of epidural anaesthesia and intra-operative events of hypovolemia and low CO. The first 25 patients were ventilated with PEEP 5 cmH2O (PEEP5), while in the last 10 patients, lung recruitment followed by individual PEEP adjustment (PEEPadj) was performed before protocol start. SETTING: Karolinska University Hospital, Stockholm, Sweden. PATIENTS: In total, 35 patients (>18 years) scheduled for major abdominal surgery with advanced hemodynamic monitoring were included in the study. MAIN OUTCOME MEASURES AND ANALYSIS: Agreement and trending ability between COEPBF and COTPTD at different clinical moments were analysed with Bland--Altman and four quadrant plots. RESULTS: In total, 322 paired values, 227 in PEEP5 and 95 in PEEPadj were analysed. Respectively, the mean COEPBF and COTPTD were 4.5 ±â€Š1.0 and 4.8 ±â€Š1.1 in the PEEP5 group and 4.9 ±â€Š1.2 and 5.0 ±â€Š1.0 l min-1 in the PEEPadj group. Mean bias (levels of agreement) and percentage error (PE) were -0.2 (-2.2 to 1.7) l min-1 and 41% for the PEEP5 group and -0.1 (-1.7 to 1.5) l min-1 and 31% in the PEEPadj group. Concordance rates during changes in COEPBF and COTPTD were 92% in the PEEP5 group and 90% in the PEEPadj group. CONCLUSION: COEPBF provides continuous noninvasive CO estimation with acceptable performance, which improved after lung recruitment and PEEP adjustment, although not interchangeable with COTPTD. This method may become a tool for continuous intra-operative CO monitoring during general anaesthesia in the future. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03444545.


Assuntos
Respiração com Pressão Positiva , Termodiluição , Animais , Débito Cardíaco , Humanos , Monitorização Fisiológica , Estudos Prospectivos , Reprodutibilidade dos Testes , Suínos
2.
Acta Anaesthesiol Scand ; 64(5): 670-676, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31965563

RESUMO

INTRODUCTION: Lung protective ventilation can decrease post-operative pulmonary complications. The aim of this study was to evaluate a capnodynamic method estimating effective lung volume (ELV) as a proxy for end-expiratory lung volume in response to PEEP changes in patients, healthy subjects and a porcine model. METHODS: Agreement and trending ability for ELV in anaesthetized patients and agreement in awake subjects were evaluated using nitrogen multiple breath wash-out/in and plethysmography as a reference respectively. Agreement and trending ability were evaluated in pigs during PEEP elevations with inert gas wash-out as reference. RESULTS: In anaesthetized patients bias (95% limits of agreement [LoA]) and percentage error (PE) at PEEP 0 cm H2 O were 133 mL (-1049 to 1315) and 71%, at PEEP 5 cm H2 O 161 mL (-1291 to 1613 mL) and 66%. In healthy subjects: 21 mL (-755 to 796 mL) and 26%. In porcines, at PEEP 5-20 cm H2 O bias decreased from 223 mL to 136 mL LoA (34-412) to (-30 to 902) and PE 29%-49%. Trending abilities in anaesthetized patients and porcines were 100% concordant. CONCLUSION: The ELV-method showed low bias but high PE in anaesthetized patients. Agreement was good in awake subjects. In porcines, agreement was good at lower PEEP levels. Concordance related to PEEP changes reached 100% in all settings. This method may become a useful trending tool for monitoring lung function during mechanical ventilation, if findings are confirmed in other clinical contexts.


Assuntos
Capnografia/métodos , Pulmão/fisiologia , Respiração com Pressão Positiva , Adulto , Idoso , Animais , Capnografia/estatística & dados numéricos , Feminino , Humanos , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Modelos Animais , Reprodutibilidade dos Testes , Respiração , Suínos , Volume de Ventilação Pulmonar , Adulto Jovem
3.
J Clin Monit Comput ; 34(6): 1199-1207, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31745763

RESUMO

Respiratory failure may cause hemodynamic instability with strain on the right ventricle. The capnodynamic method continuously calculates cardiac output (CO) based on effective pulmonary blood flow (COEPBF) and could provide CO monitoring complementary to mechanical ventilation during surgery and intensive care. The aim of the current study was to evaluate the ability of a revised capnodynamic method, based on short expiratory holds (COEPBFexp), to estimate CO during acute respiratory failure (LI) with high shunt fractions before and after compliance-based lung recruitment. Ten pigs were submitted to lung lavage and subsequent ventilator-induced lung injury. COEPBFexp, without any shunt correction, was compared to a reference method for CO, an ultrasonic flow probe placed around the pulmonary artery trunk (COTS) at (1) baseline in healthy lungs with PEEP 5 cmH2O (HLP5), (2) LI with PEEP 5 cmH2O (LIP5) and (3) LI after lung recruitment and PEEP adjustment (LIPadj). CO changes were enforced during LIP5 and LIPadj to estimate trending. LI resulted in changes in shunt fraction from 0.1 (0.03) to 0.36 (0.1) and restored to 0.09 (0.04) after recruitment manoeuvre. Bias (levels of agreement) and percentage error between COEPBFexp and COTS changed from 0.5 (- 0.5 to 1.5) L/min and 30% at HLP5 to - 0.6 (- 2.3 to 1.1) L/min and 39% during LIP5 and finally 1.1 (- 0.3 to 2.5) L/min and 38% at LIPadj. Concordance during CO changes improved from 87 to 100% after lung recruitment and PEEP adjustment. COEPBFexp could possibly be used for continuous CO monitoring and trending in hemodynamically unstable patients with increased shunt and after recruitment manoeuvre.


Assuntos
Pulmão , Insuficiência Respiratória , Animais , Débito Cardíaco , Humanos , Artéria Pulmonar , Respiração Artificial , Insuficiência Respiratória/terapia , Suínos
4.
J Clin Monit Comput ; 32(2): 311-319, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28497180

RESUMO

The capnodynamic method is a minimally invasive method continuously calculating effective pulmonary blood flow (COEPBF), equivalent to cardiac output when intra pulmonary shunt flow is low. The capnodynamic equation joined with a ventilator pattern containing cyclic reoccurring expiratory holds, provides breath to breath hemodynamic monitoring in the anesthetized patient. Its performance however, might be affected by changes in the mixed venous content of carbon dioxide (CvCO2). The aim of the current study was to evaluate COEPBF during rapid measurable changes in mixed venous carbon dioxide partial pressure (PvCO2) following ischemia-reperfusion and during sustained hypercapnia in a porcine model. Sixteen pigs were submitted to either ischemia-reperfusion (n = 8) after the release of an aortic balloon inflated during 30 min or to prolonged hypercapnia (n = 8) induced by adding an instrumental dead space. Reference cardiac output (CO) was measured by an ultrasonic flow probe placed around the pulmonary artery trunk (COTS). Hemodynamic measurements were obtained at baseline, end of ischemia and during the first 5 min of reperfusion as well as during prolonged hypercapnia at high and low CO states. Ischemia-reperfusion resulted in large changes in PvCO2, hemodynamics and lactate. Bias (limits of agreement) was 0.7 (-0.4 to 1.8) L/min with a mean error of 28% at baseline. COEPBF was impaired during reperfusion but agreement was restored within 5 min. During prolonged hypercapnia, agreement remained good during changes in CO. The mean polar angle was -4.19° (-8.8° to 0.42°). Capnodynamic COEPBF is affected but recovers rapidly after transient large changes in PvCO2 and preserves good agreement and trending ability during states of prolonged hypercapnia at different levels of CO.


Assuntos
Capnografia/métodos , Hipercapnia/diagnóstico , Pulmão/irrigação sanguínea , Circulação Pulmonar/fisiologia , Animais , Aorta/patologia , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/patologia , Hemodinâmica , Ácido Láctico/análise , Monitorização Intraoperatória , Período Perioperatório , Traumatismo por Reperfusão , Reprodutibilidade dos Testes , Respiração , Respiração Artificial , Suínos , Termodiluição
5.
J Clin Monit Comput ; 30(6): 761-769, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26377022

RESUMO

A capnodynamic calculation of effective pulmonary blood flow includes a lung volume factor (ELV) that has to be estimated to solve the mathematical equation. In previous studies ELV correlated to reference methods for functional residual capacity (FRC). The aim was to evaluate the stability of ELV during significant manipulations of cardiac output (CO) and assess the agreement for absolute values and trending capacity during PEEP changes at different lung conditions. Ten pigs were included. Alterations of alveolar carbon dioxide were induced by cyclic reoccurring inspiratory holds. The Sulphur hexafluoride technique for FRC measurements was used as reference. Cardiac output was altered by preload reduction and inotropic stimulation at PEEP 5 and 12 cmH2O both in normal lung conditions and after repeated lung lavages. ELV at baseline PEEP 5 was [mean (SD)], 810 (163) mL and decreased to 400 (42) mL after lavage. ELV was not significantly affected by CO alterations within the same PEEP level. In relation to FRC the overall bias (limits of agreement) was -35 (-271 to 201) mL, and percentage error 36 %. A small difference between ELV and FRC was seen at PEEP 5 cmH2O before lavage and at PEEP 12 cmH2O after lavage. ELV trending capability between PEEP steps, showed a concordance rate of 100 %. ELV was closely related to FRC and remained stable during significant changes in CO. The trending capability was excellent both before and after surfactant depletion.


Assuntos
Débito Cardíaco/fisiologia , Pulmão/fisiologia , Anestesia , Animais , Capacidade Residual Funcional , Hemodinâmica , Pulmão/irrigação sanguínea , Pulmão/fisiopatologia , Lesão Pulmonar/fisiopatologia , Medidas de Volume Pulmonar , Modelos Teóricos , Respiração com Pressão Positiva/métodos , Valores de Referência , Fluxo Sanguíneo Regional , Testes de Função Respiratória , Hexafluoreto de Enxofre/química , Tensoativos , Suínos , Volume de Ventilação Pulmonar , Fatores de Tempo
6.
Lakartidningen ; 1132016 05 17.
Artigo em Sueco | MEDLINE | ID: mdl-27187697

RESUMO

Valvular heart disease constitutes the majority of all causes of heart disease in pregnancy. In the presence of valvular heart disease, the necessary haemodynamic changes of pregnancy might cause heart failure, leading to severe maternal and fetal morbidity and even mortality. In lower-income countries, rheumatic heart disease remains one of the major causes of death related to pregnancy [6]. In low-income countries, rheumatic heart disease is found in 60% to 80% of the pregnant women with heart disease, and 10% to 30% have a congenital disorder including congenital valve disorders [4]. The most common valvular lesion of rheumatic heart disease is mitral stenosis. This valvular lesion can be the cause of extreme disability and even mortality during pregnancy due to an increase in the transvalvular gradient and a rise in left atrial pressure. The maternal mortality associated with mitral stenosis is stratified by New York Heart Association (NYHA) classification: class I, 0.1%; class II, 0.3%; class III, 5.5%; and class IV, 6.0%. Most patients are in class I or II at presentation, but 12% to 25% of patients are in class III or IV [14].


Assuntos
Estenose da Valva Mitral/diagnóstico , Cardiopatia Reumática/diagnóstico , Adulto , Cesárea , Etiópia/etnologia , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/terapia , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Complicações Cardiovasculares na Gravidez/terapia , Resultado da Gravidez , Cardiopatia Reumática/complicações , Cardiopatia Reumática/terapia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa