Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Synapse ; 78(4): e22304, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38896000

RESUMO

The goal of this report is to explore how K2P channels modulate axonal excitability by using the crayfish ventral superficial flexor preparation. This preparation allows for simultaneous recording of motor nerve extracellular action potentials (eAP) and intracellular excitatory junctional potential (EJP) from a muscle fiber. Previous pharmacological studies have demonstrated the presence of K2P-like channels in crayfish. Fluoxetine (50 µM) was used to block K2P channels in this study. The blocker caused a gradual decline, and eventually complete block, of motor axon action potentials. At an intermediate stage of the block, when the peak-to-peak amplitude of eAP decreased to ∼60%-80% of the control value, the amplitude of the initial positive component of eAP declined at a faster rate than that of the negative peak representing sodium influx. Furthermore, the second positive peak following this sodium influx, which corresponds to the after-hyperpolarizing phase of intracellularly recorded action potentials (iAP), became larger during the intermediate stage of eAP block. Finally, EJP recorded simultaneously with eAP showed no change in amplitude, but did show a significant increase in synaptic delay. These changes in eAP shape and EJP delay are interpreted as the consequence of depolarized resting membrane potential after K2P channel block. In addition to providing insights to possible functions of K2P channels in unmyelinated axons, results presented here also serve as an example of how changes in eAP shape contain information that can be used to infer alterations in intracellular events. This type of eAP-iAP cross-inference is valuable for gaining mechanistic insights here and may also be applicable to other model systems.


Assuntos
Potenciais de Ação , Astacoidea , Axônios , Fluoxetina , Neurônios Motores , Animais , Astacoidea/efeitos dos fármacos , Astacoidea/fisiologia , Fluoxetina/farmacologia , Potenciais de Ação/efeitos dos fármacos , Potenciais de Ação/fisiologia , Neurônios Motores/efeitos dos fármacos , Neurônios Motores/fisiologia , Axônios/efeitos dos fármacos , Axônios/fisiologia
2.
J Arthroplasty ; 38(7S): S265-S273, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37105329

RESUMO

BACKGROUND: Larger head-to-neck ratio of dual mobility (DM) hip arthroplasties provide greater range of motion/less risk of dislocation, but raise concerns for high wear and friction. We measured in vitro, the wear rates of contemporary DM hips with highly cross-linked ultra high molecular weight polyethylene (UHWMPE), where it came from, and their frictional torques. METHODS: Hip simulators were used to compare the wear of DM to fixed-bearing (FB) designs of 2 different implants. Each of 8 different configurations underwent millions of simulated walking cycle tests, some as full DM, some as FB controls, some DM with the outer-articulation deliberately immobilized, and some the inner. Wear and 3-dimensional-frictional torques were measured and friction independent of size was deduced. RESULTS: The DM hips produced lower wear and friction-torque than the FB hips. The DM wear during walking gait comes mostly from the smaller inner articular surface. If the outer surface was immobilized, the wear and torque of the inner alone would be small, but the full DM (inner and outer free-to-move) wear and torque were smallest of all. Friction measurements expectedly showed larger hips having higher frictional torques, but the DM showed the lowest, again because its motion was mostly the smaller inner articulation; smaller than even a modern fixed-bearing hip. CONCLUSION: The DM hips appear to combine the benefits of greater range of motion and less impingement of larger hips, with the lower wear and friction of smaller FB hips, with some benefits compromised if the outer or inner articulations are immobilized.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Desenho de Prótese , Fricção , Falha de Prótese
3.
J Arthroplasty ; 37(7S): S674-S677, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35283230

RESUMO

BACKGROUND: Two-stage reimplantation is an effective treatment for periprosthetic joint infection (PJI). Many factors are involved in the variable success of this procedure. The purpose of this study is to examine the relationship between patient risk factors, comorbidities, and the pathogen on reinfection rates following two-stage reimplantation. METHODS: We evaluated 158 patients treated for PJI from 2008-2019. Only patients who had completed a two-stage exchange were included. Patient demographics, comorbidities, laboratory values, time-to-reimplantation, pathogen, antibiotic sensitivities, host status, and reinfection rates were assessed. Multivariate analysis was performed to identify correlation between risk factors and reinfection. A P-value < .05 was considered statistically significant. RESULTS: 31 patients experienced a reinfection (19.6%). There was a statistically significant association between infection with Methicillin Sensitive Staphylococcus Aureus (MSSA) and reinfection (P = .046). Patients with a reinfection also had a significantly greater median serum C-reactive protein (CRP) level (12.65 g/dL) at the time of diagnosis compared to patients without a reinfection (5.0 g/dL) (P = .010). Median Erythrocyte Sedimentation Rate (ESR) (56 in no re-infection and 69 in re-infection) and time-to-reimplantation (101 days in no reinfection and 141 days in reinfection) demonstrated a trend toward an association with re-infection but were not statistically significant (P = .055 and P = .054 respectively). CONCLUSION: As the number of arthroplasties continue to rise, PJIs are increasing proportionately and represent a significant revision burden. Elevated C-reactive protein (CRP) levels and Methicillin Sensitive Staphylococcus aureus (MSSA) infection were strongly associated with failure of a two-stage reimplantation. While not statistically significant with our numbers, there were strong trends toward an association between elevated Erythrocyte Sedimentation Rate (ESR), longer time-to-reimplantation, and reinfection.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Reinfecção , Reimplante , Infecções Estafilocócicas , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Artrite Infecciosa/etiologia , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Proteína C-Reativa/análise , Humanos , Meticilina/farmacologia , Meticilina/uso terapêutico , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Reoperação , Estudos Retrospectivos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/etiologia
4.
Clin Orthop Relat Res ; 474(7): 1649-56, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26831479

RESUMO

BACKGROUND: The continued presence of biofilm may be one cause of the high risk of failure observed with irrigation and débridement with component retention in acute periprosthetic joint infection (PJI). There is a poor understanding of the role of biofilm antibiotic tolerance in PJI. QUESTIONS/PURPOSES: (1) Do increasing doses of cefazolin result in decreased viable biofilm mass on arthroplasty materials? (2) Is cefazolin resistance phenotypic or genotypic? (3) Is biofilm viability a function of biofilm depth after treatment with cefazolin? (4) Is the toxin-antitoxin system, yoeB expression, associated with antibiotic stress? METHODS: Methicillin-sensitive Staphylococcus aureus biofilm was cultured on total knee arthroplasty (TKA) materials and exposed to increasing doses of cefazolin (control, 0.5, 1.0, 10.0, 100.0 µg/mL). Quantitative confocal microscopy and quantitative culture were used to measure viable biofilm cell density. To determine if cefazolin resistance was phenotypic or genotypic, we measured minimum inhibitory concentration (MIC) after exposure to different cefazolin concentrations; changes in MIC would suggest genotypic features, whereas unchanged MIC would suggest phenotypic behavior. Finally, quantitative reverse transcription-polymerase chain reaction was used to quantify expression of yoeB levels between biofilm and planktonic bacteria after exposure to 1 µg/mL cefazolin for 3 hours. RESULTS: Although live biofilm mass was reduced by exposure to cefazolin when compared with biofilm mass in controls (39.2 × 10(3) ± 26.4 × 10(3) pixels), where the level after 0.5 µg/mL exposure also showed reduced mass (20.3 × 10(3) ± 11.9 × 10(3) pixels), no further reduction was seen after higher doses (mass at 1.0 µg/mL: 5.0 × 10(3) pixels ± 1.1 × 10(3) pixels; at 10.0 µg/mL: 6.4 × 10(3) ± 9.6 × 10(3) pixels; at 100.0 µg/mL: 6.4 × 10(3) ± 3.9 × 10(3)). At the highest concentration tested (100 µg/mL), residual viable biofilm was present on all three materials, and there were no differences in percent biofilm survival among cobalt-chromium (18.5% ± 15.1%), polymethylmethacrylate (22.8% ± 20.2%), and polyethylene (14.7% ± 10.4%). We found that tolerance was a phenotypic phenomenon, because increasing cefazolin exposure did not result in changes in MIC as compared with controls (MIC in controls: 0.13 ± 0.02; at 0.5 µg/mL: 0.13 ± 0.001, p = 0.96; at 1.0 µg/m: 0.14 ± 0.04, p = 0.95; at 10.0 µg/m: 0.11 ± 0.016, p = 0.47; at 100.0 µg/m: 0.94 ± 0.047, p = 0.47). Expression of yoeB after 1 µg/mL cefazolin for 3 hours in biofilm cells was greater in biofilm but not in planktonic cells (biofilm: 62.3-fold change, planktonic cells: -78.8-fold change, p < 0.001). CONCLUSIONS: Antibiotics are inadequate at complete removal of the biofilm from the surface of TKA materials. Results suggest that bacterial persisters are responsible for this phenotypic behavior allowing biofilm high tolerance to antibiotics. CLINICAL RELEVANCE: Antibiotic-tolerant biofilm suggests a mechanism behind the poor results in irrigation and débridement for acute TKA PJI.


Assuntos
Antibacterianos/farmacologia , Artroplastia do Joelho/efeitos adversos , Biofilmes/efeitos dos fármacos , Cefazolina/farmacologia , Farmacorresistência Bacteriana , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus/efeitos dos fármacos , Artroplastia do Joelho/instrumentação , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Toxinas Bacterianas/genética , Toxinas Bacterianas/metabolismo , Biofilmes/crescimento & desenvolvimento , Relação Dose-Resposta a Droga , Farmacorresistência Bacteriana/genética , Endorribonucleases/genética , Endorribonucleases/metabolismo , Prótese do Joelho/microbiologia , Meticilina/farmacologia , Testes de Sensibilidade Microbiana , Viabilidade Microbiana/efeitos dos fármacos , Microscopia Confocal , Fenótipo , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/genética , Staphylococcus aureus/crescimento & desenvolvimento , Staphylococcus aureus/metabolismo
5.
J Med Ethics ; 40(5): 346-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23955369

RESUMO

BACKGROUND: The number of coauthors in the medical literature has increased over the past 50 years as authorship continues to have important academic, social and financial implications. AIM AND METHOD: The study aim was to determine the prevalence of honorary authorship in biomedical publications and identify the factors that lead to its existence. An email with a survey link was sent anonymously to 9283 corresponding authors of PubMed articles published within 1 year of contact. RESULTS: A completed survey was obtained from 1246 corresponding authors, a response rate of 15.75%. One-third (33.4%) admitted that they had added authors who did not deserve authorship credit. Origin of the study from Europe and Asia (p ≤ 0.001 and 0.005, respectively), study type as case report/case series (p=0.036) and increasing number of coauthors were found to be the associated factors on multivariate analysis. Journal impact factor was also found to be associated with honorary authorship (mean journal impact factor was 4.82 (SD 6.32) for those who self-reported honorary authorship and 5.60 (SD 7.13) for those who did not report unjust authorship, p=0.05). In retrospect, 75% of the authors indicated that they would remove unjustified names from the authorship list. Reasons for adding honorary authors were complimentary (39.4%), to avoid conflict at work (16.1%), to facilitate article acceptance (7.2%), and other (3.6%). CONCLUSIONS: Honorary authorship is relatively common in biomedical publications. Researchers should comply with the International Committee of Medical Journal Editors' criteria for authorship.


Assuntos
Autoria , Pesquisa Biomédica , Editoração , Pesquisadores , Relatório de Pesquisa , Ásia , Autoria/normas , Políticas Editoriais , Ética em Pesquisa , Europa (Continente) , Humanos , Internet , Editoração/ética , Editoração/normas , Editoração/tendências , Pesquisadores/ética , Pesquisadores/normas , Pesquisadores/tendências , Autorrelato , Inquéritos e Questionários
6.
J Arthroplasty ; 29(6): 1128-32, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24439797

RESUMO

In acute periprosthetic infection, irrigation and debridement with component retention has a high failure rate in some studies. We hypothesize that pulse lavage irrigation is ineffective at removing biofilm from total knee arthroplasty (TKA) components. Staphylococcus aureus biofilm mass and location was directly visualized on arthroplasty materials with a photon collection camera and laser scanning confocal microscopy. There was a substantial reduction in biofilm signal intensity, but the reduction was less than a ten-fold decrease. This suggests that irrigation needs to be further improved for the removal of biofilm mass below the necessary bioburden level to prevent recurrence of acute infection in total knee arthroplasty.


Assuntos
Artroplastia do Joelho/instrumentação , Biofilmes , Contaminação de Equipamentos , Prótese do Joelho/microbiologia , Staphylococcus aureus/isolamento & purificação , Irrigação Terapêutica , Microscopia Confocal
7.
Clin Orthop Relat Res ; 471(1): 155-61, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22972652

RESUMO

BACKGROUND: Computer-aided surgery aims to improve implant alignment in TKA but has only been adopted by a minority for routine use. A novel approach, navigated freehand bone cutting (NFC), is intended to achieve wider acceptance by eliminating the need for cumbersome, implant-specific mechanical jigs and avoiding the expense of navigation. QUESTIONS/PURPOSES: We determined cutting time, surface quality, implant fit, and implant alignment after NFC of synthetic femoral specimens and the feasibility and alignment of a complete TKA performed with NFC technology in cadaveric specimens. METHODS: Seven surgeons prepared six synthetic femoral specimens each, using our custom NFC system. Cutting times, quality of bone cuts, and implant fit and alignment were assessed quantitatively by CT surface scanning and computational measurements. Additionally, a single surgeon performed a complete TKA on two cadaveric specimens using the NFC system, with cutting time and implant alignment analyzed through plain radiographs and CT. RESULTS: For the synthetic specimens, femoral coronal alignment was within ± 2° of neutral in 94% of the specimens. Sagittal alignment was within 0° to 5° of flexion in all specimens. Rotation was within ± 1° of the epicondylar axis in 97% of the specimens. The mean time to make cuts improved from 13 minutes for the first specimen to 9 minutes for the fourth specimen. TKA was performed in two cadaveric specimens without complications and implants were well aligned. CONCLUSIONS: TKA is feasible with NFC, which eliminates the need for implant-specific instruments. We observed a fast learning curve. CLINICAL RELEVANCE: NFC has the potential to improve TKA alignment, reduce operative time, and reduce the number of instruments in surgery. Fewer instruments and less sterilization could reduce costs associated with TKA.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador/instrumentação , Artroplastia do Joelho/métodos , Humanos , Duração da Cirurgia , Projetos Piloto , Amplitude de Movimento Articular , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
8.
Proc Inst Mech Eng H ; 237(6): 669-682, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37139865

RESUMO

The high prevalence of cardiac diseases around the world has created a need for quick, easy and cost effective approaches to diagnose heart disease. The auscultation and interpretation of heart sounds using the stethoscope is relatively inexpensive, requires minimal to advanced training, and is widely available and easily carried by healthcare providers working in urban environments or medically underserved rural areas. Since René-Théophile-Hyacinthe Laennec's simple, monoaural design, the capabilities of modern-day, commercially available stethoscopes and stethoscope systems have radically advanced with the integration of electronic hardware and software tools, however these systems are largely confined to the metropolitan medical centers. The purpose of this paper is to review the history of stethoscopes, compare commercially available stethoscope products and analytical software, and discuss future directions. Our review includes a description of heart sounds and how modern software enables the measurement and analysis of time intervals, teaching auscultation, remote cardiac examination (telemedicine) and, more recently, spectrographic evaluation and electronic storage. The basic methodologies behind modern software algorithms and techniques for heart sound preprocessing, segmentation and classification are described to provide awareness.


Assuntos
Ruídos Cardíacos , Estetoscópios , Auscultação/métodos , Software , Algoritmos , Auscultação Cardíaca
9.
J Arthroplasty ; 27(3): 461-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22146382

RESUMO

Concerns about reduced strength, fatigue resistance, and oxidative stability of highly cross-linked and remelted ultrahigh-molecular-weight polyethylene (UHMWPE) have limited its clinical acceptance for total knee arthroplasty. We hypothesized that a highly cross-linked UHMWPE stabilized with vitamin E would have less oxidation and loss of mechanical properties. We compared the oxidation, in vitro strength, fatigue-crack propagation resistance, and wear of highly cross-linked UHMWPE doped with vitamin E to γ-inert-sterilized direct compression-molded UHMWPE (control). After accelerated aging, the control material showed elevated oxidation, loss of small-punch mechanical properties, and loss of fatigue-crack propagation resistance. In contrast, the vitamin E-stabilized material had minimal changes and exhibited 73% to 86% reduction in wear for both cruciate-retaining and posterior-stabilized total knee arthroplasty designs. Highly cross-linked vitamin E-stabilized UHMWPE performed well in vitro.


Assuntos
Prótese do Joelho , Teste de Materiais , Polietileno , Polietilenos , Vitamina E , Artroplastia do Joelho , Desenho de Prótese , Fatores de Tempo
10.
J Orthop Res ; 39(9): 1851-1859, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33002224

RESUMO

Over the last three decades, there have been significant advancements in knee and hip replacement technology. The implants and the surgical technology we now have to aid in their implantation are advancing and improving functional outcomes and survivorship. Despite these advancements, there are still issues with patient satisfaction, functional limitations, and early revisions due to instability and aseptic loosening. This article reviews the state of current technology in hip and knee replacement implant design and surgical technique, and reviews some of the current implant designs and surgical technologies that may be able to solve some of the most common issues in the knee and hip replacement surgery.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese do Joelho , Artroplastia de Quadril/métodos , Humanos , Articulação do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação
11.
J Orthop Res ; 38(7): 1436-1444, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32437026

RESUMO

Over the last three decades there have been significant advancements in the knee and hip replacement technology that has been driven by an issue in the past concerning adverse local tissue reactions, aseptic and septic loosening. The implants and the materials we utilize have improved over the last two decades and in knee and hip replacement there has been a decrease in the failures attributed to wear and osteolysis. Despite these advancements there are still issues with patient satisfaction and early revisions due to septic and aseptic loosening in knee replacement patients. This article reviews the state of current implant material technology in hip and knee replacement surgery, discusses some of the unmet needs we have in biomaterials, and reviews some of the current biomaterials and technology that may be able to solve the most common issues in the knee and hip replacement surgery.


Assuntos
Materiais Biocompatíveis , Prótese de Quadril , Prótese do Joelho , Artroplastia de Substituição , Cerâmica , Humanos
12.
Nanotechnology ; 20(24): 245303, 2009 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-19468161

RESUMO

Nanocrystalline zirconia has recently attracted extensive research interest due to its unique mechanical, thermal and electrical properties as compared with bulk zirconia counterparts, and it is of particular importance for controlling the phase stability of different polymorphs (amorphous, cubic, tetragonal and monoclinic phases) in different size regimes. In this work, we performed ion beam bombardments on bilayers (amorphous and cubic) of nano-zirconia using 1 MeV Kr2+ irradiation. Transmission electron microscopy (TEM) analysis reveals that amorphous zirconia transforms to a tetragonal structure under irradiation at room temperature, suggesting that the tetragonal phase is more energetically favorable under these conditions. The final grain size of the tetragonal zirconia can be controlled by irradiation conditions. A slower kinetics in the grain growth from cubic nanocrystalline zirconia was found as compared with that for the tetragonal grains recrystallized from the amorphous layer. The radiation-induced nanograins of tetragonal ZrO2 are stable at ambient conditions and maintain their physical integrity over a long period of time after irradiation. These results demonstrated that ion beam methods provide the means to control the phase stability and structure of zirconia polymorphs.


Assuntos
Cristalização/métodos , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Nanotecnologia/métodos , Titânio/química , Zircônio/química , Zircônio/efeitos da radiação , Íons Pesados , Substâncias Macromoleculares/química , Teste de Materiais , Conformação Molecular/efeitos da radiação , Nanoestruturas/efeitos da radiação , Tamanho da Partícula , Transição de Fase , Propriedades de Superfície
13.
Proc Inst Mech Eng H ; 233(9): 921-930, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31223052

RESUMO

Biomaterials with enhanced biocompatibility are favored in implant studies to improve the outcomes of total joint replacement surgeries. This study tested the hypothesis that nano-structured surfaces for orthopedic applications, produced by the ion beam-assisted deposition method, would enhance osteointegration by altering the expression of bone-associated genes in osteoblasts. The ion beam-assisted deposition technique was employed to deposit nano-films on glass or titanium substrates. The effects of the ion beam-assisted deposition produced surfaces on the human osteosarcoma cell line SAOS-2 at the molecular level were investigated by assays of adhesion, proliferation, differentiation, and apoptosis on coated surfaces versus uncoated cobalt-chrome, as the control. Ion beam-assisted deposition nano-coatings enhanced bone-associated gene expression at initial cell adhesion, proliferation, and differentiation compared to cobalt-chrome surfaces as assessed by polymerase chain reaction techniques. Increased cell proliferation was observed using a nuclear cell proliferation-associated antigen. Moreover, enhanced cell differentiation was determined by alkaline phosphatase activity, an indicator of bone formation. In addition, programmed cell death assessed by annexin V staining and flow cytometry was lower on nano-surfaces compared to cobalt-chrome surfaces. Overall, the results indicate that nano-coated surfaces produced by the ion beam-assisted deposition technique for use on implants were superior to orthopedic grade cobalt-chrome in supporting bone cell adhesion, proliferation, and differentiation and reducing apoptosis. Thus, surface properties altered by the ion beam-assisted deposition technique should enhance bone formation and increase the biocompatibility of bone cell-associated surfaces.


Assuntos
Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Regulação da Expressão Gênica/efeitos dos fármacos , Nanoestruturas/química , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo , Osteogênese/genética , Apoptose/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Vidro/química , Humanos , Osteoblastos/citologia , Osteogênese/efeitos dos fármacos , Propriedades de Superfície , Titânio/química
14.
Clin Transplant ; 22(5): 664-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18435783

RESUMO

A technically difficult liver transplant was performed in a 68-yr-old male with Alveolar Echinococcosis causing end-stage liver disease. The pathology was extensive and included hepatic artery thrombosis, Budd-Chiari syndrome, and right hemidiaphragm invasion necessitating resection of this portion of diaphragm and direct donor cava anastomosis to the right atrium. The patient is now 21 months since transplant disease free with normal liver function.


Assuntos
Síndrome de Budd-Chiari/parasitologia , Equinococose Hepática/complicações , Echinococcus multilocularis , Falência Hepática/etiologia , Falência Hepática/terapia , Transplante de Fígado , Idoso , Animais , Humanos , Masculino
15.
Clin Orthop Relat Res ; 466(11): 2677-85, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18758877

RESUMO

One of the assumed benefits of mobile bearings is the reduction of UHMWPE wear. However, to date, such benefit has not been categorically proven. To test the hypothesis that rotating platform total knee arthroplasty would have less wear than a fixed-bearing of the same design, this in vitro study compared the wear and kinematics (which influence wear) of one type of mobile with fixed-bearing tibial components of otherwise identical design. We tested four fixed bearing (FB) and four rotating platforms (RP) on force control knee simulators using identical ISO standard force inputs and simulated soft tissue restraint for 6 million walking cycles. The internal/external rotations peaked just before toe off, reaching an average maximum of 7 degrees internal (tibial rotation) in the RP, 1.5 times that of the FB, which peaked at approximately 4.5 degrees internally. Two of the RP specimens showed infrequent and mostly temporary dislocations of the UHMWPE insert. The wear rate for the FB averaged 8.14 +/- 2.63 mg/million cycles and the RP averaged 6.78 +/- 1.74 mg/million cycles. Both were very low wear rates compared with most other implants tested similarly in the same laboratory. We concluded polyethylene wear was similar for both designs.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Modelos Biológicos , Fenômenos Biomecânicos , Análise de Falha de Equipamento/métodos , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Teste de Materiais/métodos , Desenho de Prótese , Amplitude de Movimento Articular/fisiologia
16.
Scanning ; 30(2): 59-64, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18288715

RESUMO

The application of titanium dioxide (TiO(2)) films as surgical implant coatings for antibiotic attachment depends crucially on their available surface area and thus their surface morphology and crystallinity. Here, we report our fabrication of high Wenzel ratio TiO(2) films targeted to increase the film surface area using the ion beam-assisted deposition (IBAD) technique at high-deposition temperatures (approximately 610 degrees C). The modulation of the films' surface morphology was accomplished by varying the chemical identity of the concurrent ion beams bombarded on the films during the e-beam evaporation process. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) were employed to investigate the surface morphology of the as-deposited films. X-ray diffractometry (XRD) revealed that these nanocrystalline films primarily consist of anatase phase TiO(2). Wenzel ratio, the ratio of the actual surface area to the projected area, of IBAD films prepared with argon, oxygen, and nitrogen ion beams was measured to be 1.52, 1.31 and 1.49, respectively. The effect of the differences in chemical reactivity and ion size of these three type ion beams are discussed to explain the present results.


Assuntos
Materiais Revestidos Biocompatíveis , Nanopartículas Metálicas/ultraestrutura , Titânio , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Difração de Raios X
17.
J Am Coll Surg ; 205(3): 439-44, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17765160

RESUMO

BACKGROUND: Pilonidal disease is a common condition among young people. Complicated pilonidal surgical wounds are associated with considerable morbidity, including chronic sacral wound, loss of work time, and lifestyle limitation. The aim of our study is to report our experience with Karydakis procedure and explore the risk factors associated with infection and poor healing in pilonidal operation. STUDY DESIGN: A 3-year experience of a Joint-Commission International accredited tertiary center in patients with pilonidal sinus operations is reported. We retrospectively reviewed the charts of unselected patients with pilonidal sinus who underwent excision and primary closure on elective basis in terms of wound healing, surgical site infection, and return to work. Variables predictive of surgical site infection and disruption were assessed by multiple logistic analyses. RESULTS: From January 2004 to December 2006, 94 patients with pilonidal disease underwent excision and primary closure on elective basis. Incidence of surgical site infection was 12.8%. No recurrence was observed after median followup of 6 months, with interquartile range of 4 to 9 months. Smoking (p = 0.027) and obesity (p = 0.047) were independent risk factors for wound infections. CONCLUSIONS: Excision and primary closure is an acceptable modality of treatment in nonobese and nonsmoker patients with pilonidal sinus disease. Infection rate in obese patients and smokers is unacceptably high, and active preoperative weight loss and smoking cessation or simple laid open procedure is recommended in these patients.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório/normas , Seio Pilonidal/cirurgia , Deiscência da Ferida Operatória/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Adolescente , Adulto , Feminino , Humanos , Modelos Logísticos , Masculino , Obesidade/complicações , Estudos Retrospectivos , Fatores de Risco , Fumar/efeitos adversos , Estatísticas não Paramétricas , Deiscência da Ferida Operatória/prevenção & controle , Infecção da Ferida Cirúrgica/prevenção & controle , Resultado do Tratamento , Cicatrização
18.
J Biomech ; 40(7): 1550-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17084405

RESUMO

Pre-clinical experimental wear testing of total knee replacement (TKR) components is an invaluable tool for evaluating new implant designs and materials. However, wear testing can be a lengthy and expensive process, and hence parametric studies evaluating the effects of geometric, loading, or alignment perturbations may at times be cost-prohibitive. The objectives of this study were to develop an adaptive FE method capable of simulating wear of a polyethylene tibial insert and to compare predicted kinematics, weight loss due to wear, and wear depth contours to results from a force-controlled experimental knee simulator. Finite element-based computational wear predictions were performed to 5 million gait cycles using both force- and displacement-controlled inputs. The displacement-controlled inputs, by accurately matching the experimental tibiofemoral motion, provided an evaluation of the simple wear theory. The force-controlled inputs provided an evaluation of the overall numerical method by simultaneously predicting both kinematics and wear. Analysis of the predicted wear convergence behavior indicated that 10 iterations, each representing 500,000 gait cycles, were required to achieve numerical accuracy. Using a wear factor estimated from the literature, the predicted kinematics, polyethylene wear contours, and weight loss were in reasonable agreement with the experimental data, particularly for the stance phase of gait. Although further development of the simplified wear theory is important, the initial predictions are encouraging for future use in design phase implant evaluation. In contrast to the experimental testing which occurred over approximately 2 months, computational wear predictions required only 2h.


Assuntos
Artroplastia do Joelho/normas , Análise de Elementos Finitos , Marcha/fisiologia , Teste de Materiais/métodos , Falha de Prótese , Fenômenos Biomecânicos , Humanos , Modelos Biológicos , Polietileno , Tíbia
19.
Vasc Endovascular Surg ; 41(6): 559-63, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18166641

RESUMO

Traumatic mesenteric arterioportal fistulas (APF) are rare but serious and life-threatening. This article reports the case of a 24-year-old female who suffered a gunshot wound to the abdomen and subsequently developed a superior mesenteric artery (SMA) pseudoaneurysm and APF, which caused secondary right heart failure and pulmonary hypertension. The patient underwent a successful endovascular stent-graft exclusion of the pseudoaneurysm/APF. The patient was asymptomatic 18 months post procedure and leading an active life with a normal arterial flow in the SMA confirmed by duplex ultrasonography.


Assuntos
Falso Aneurisma/cirurgia , Fístula Arteriovenosa/cirurgia , Implante de Prótese Vascular , Artéria Mesentérica Superior/cirurgia , Veia Esplênica/cirurgia , Ferimentos por Arma de Fogo/complicações , Traumatismos Abdominais/complicações , Traumatismos Abdominais/diagnóstico por imagem , Traumatismos Abdominais/etiologia , Traumatismos Abdominais/cirurgia , Adulto , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Fístula Arteriovenosa/complicações , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/etiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Artéria Mesentérica Superior/diagnóstico por imagem , Procedimentos Cirúrgicos Minimamente Invasivos , Radiografia Intervencionista , Veia Esplênica/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ferimentos por Arma de Fogo/diagnóstico por imagem , Ferimentos por Arma de Fogo/cirurgia
20.
Foot Ankle Int ; 28(2): 219-23, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17296143

RESUMO

BACKGROUND: The success of ankle arthrodesis for the treatment of post-traumatic ankle arthritis depends on achieving and maintaining rigid fixation of the prepared tibiotalar interface. The purpose of this study was to examine the biomechanical effect of anterior plate supplementation of a popular three-screw fusion construct. METHODS: Six fresh-frozen cadaver ankles were prepared and instrumented with three partially threaded screws compressing the tibiotalar interface. Testing was done with and without supplementary anterior plate fixation under three different decoupled loading conditions: plantarflexion/dorsiflexion, inversion/eversion, and rotation. Motion at the tibiotalar interface was recorded. RESULTS: Anterior plating increased construct stiffness by a factor of 3.5, 1.9, and 1.4 for the sagittal, coronal, and torsion modes, respectively. Less motion occurred at the tibiotalar interface in all to the three different loading conditions (p = 0.031) with plate supplementation. CONCLUSIONS: Compared to screws alone, anterior plate supplementation increases construct rigidity and decreases micromotion at the ankle fusion interface.


Assuntos
Articulação do Tornozelo/cirurgia , Artrodese/instrumentação , Placas Ósseas , Articulação do Tornozelo/fisiologia , Artrite/cirurgia , Artrodese/métodos , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Humanos , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa