Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Lasers Surg Med ; 51(10): 920-932, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31236997

RESUMO

BACKGROUND AND OBJECTIVE: Microcirculation plays a critical role in physiologic processes and several disease states. Laser speckle imaging (LSI) is a full-field, real-time imaging technique capable of mapping microvessel networks and providing relative flow velocity within the vessels. In this study, we demonstrate that LSI combine with multispectral reflectance imaging (MSRI), which allows for distinction between veins and arteries in the vascular flow maps produced by LSI. We apply this combined technique to mouse cerebral vascular network in vivo, comparing imaging through the skull, to the dura mater and brain directly through a craniectomy, and through a transparent cranial "Window to the Brain" (WttB) implant. STUDY DESIGN/MATERIALS AND METHODS: The WttB implant used in this study is made of a nanocrystalline Yttria-Stabilized-Zirconia ceramic. MSRI was conducted using white-light illumination and filtering the reflected light for 560, 570, 580, 590, 600, and 610 nm. LSI was conducted using an 810 nm continuous wave near-infrared laser with incident power of 100 mW, and the reflected speckle pattern was captured by a complementary metal-oxide-semiconductor (CMOS) camera. RESULTS: Seven vessel branches were analyzed and comparison was made between imaging through the skull, craniectomy, and WttB implant. Through the skull, MSRI did not detect any vessels, and LSI could not image microvessels. Imaging through the WttB implant, MSRI was able to identify veins versus arteries, and LSI was able to image microvessels with only slightly higher signal-to-noise ratio and lower sharpness than imaging the brain through a craniectomy. CONCLUSIONS: This study demonstrates the ability to perform MSRI-LSI across a transparent cranial implant, to allow for cerebral vascular networks to be mapped, including microvessels. These images contain additional information such as vein-artery separation and relative blood flow velocities, information which is of value scientifically and medically. The WttB implant provides substantial improvements over imaging through the murine cranial bone, where microvessels are not visible and MSRI cannot be performed. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.


Assuntos
Encéfalo/irrigação sanguínea , Microvasos/diagnóstico por imagem , Imagem Óptica/métodos , Próteses e Implantes , Implantação de Prótese , Crânio/cirurgia , Animais , Velocidade do Fluxo Sanguíneo , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Cerâmica , Masculino , Camundongos , Microcirculação/fisiologia , Imagem Óptica/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho , Ítrio , Zircônio
2.
J Biomech Eng ; 139(3)2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28024161

RESUMO

The role of trabeculae carneae in modulating left ventricular (LV) diastolic compliance remains unclear. The objective of this study was to determine the contribution of trabeculae carneae to the LV diastolic compliance. LV pressure-volume compliance curves were measured in six human heart explants from patients with LV hypertrophy at baseline and following trabecular cutting. The effect of trabecular cutting was also analyzed with finite-element model (FEM) simulations. Our results demonstrated that LV compliance improved after trabecular cutting (p < 0.001). Finite-element simulations further demonstrated that stiffer trabeculae reduce LV compliance further, and that the presence of trabeculae reduced the wall stress in the apex. In conclusion, we demonstrate that integrity of the LV and trabeculae is important to maintain LV stiffness and loss in trabeculae leads to more LV compliance.


Assuntos
Diástole/fisiologia , Ventrículos do Coração , Miocárdio/metabolismo , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Estresse Mecânico
3.
Lasers Surg Med ; 48(8): 782-789, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27389389

RESUMO

BACKGROUND AND OBJECTIVE: The development and feasibility of a novel nanocrystalline yttria-stabilized-zirconia (nc-YSZ) cranial implant has been recently established. The purpose of what we now call "window to the brain (WttB)" implant (or platform), is to improve patient care by providing a technique for delivery and/or collection of light into/from the brain, on demand, over large areas, and on a chronically recurring basis without the need for repeated craniotomies. WttB holds the transformative potential for enhancing light-based diagnosis and treatment of a wide variety of brain pathologies including cerebral edema, traumatic brain injury, stroke, glioma, and neurodegenerative diseases. However, bacterial adhesion to the cranial implant is the leading factor for biofilm formation (fouling), infection, and treatment failure. Escherichia coli (E. coli), in particular, is the most common isolate in gram-negative bacillary meningitis after cranial surgery or trauma. The transparency of our WttB implant may provide a unique opportunity for non-invasive treatment of bacterial infection under the implant using medical lasers. STUDY DESIGN/MATERIALS AND METHODS: A drop of a diluted overnight culture of BL21-293 E. coli expressing luciferase was seeded between the nc-YSZ implant and the agar plate. This was followed by immediate irradiation with selected laser. After each laser treatment the nc-YSZ was removed, and cultures were incubated for 24 hours at 37 °C. The study examined continuous wave (CW) and pulsed wave (PW) modes of near-infrared (NIR) 810 nm laser wavelength with a power output ranging from 1 to 3 W. During irradiation, the temperature distribution of nc-YSZ surface was monitored using an infrared thermal camera. Relative luminescence unit (RLU) was used to evaluate the viability of bacteria after the NIR laser treatment. RESULTS: Analysis of RLU suggests that the viability of E. coli biofilm formation was reduced with NIR laser treatment when compared to the control group (P < 0.01) and loss of viability depends on both laser fluence and operation mode (CW or PW). The results demonstrate that while CW laser reduces the biofilm formation more than PW laser with the same power, the higher surface temperature of the implant generated by CW laser limits its medical efficacy. In contrast, with the right parameters, PW laser produces a more moderate photothermal effect which can be equally effective at controlling bacterial growth. CONCLUSIONS: Our results show that E. coli biofilm formation across the thickness of the nc-YSZ implant can be disrupted using NIR laser treatment. The results of this in vitro study suggest that using nc-YSZ as a cranial implant in vivo may also allow for locally selective, non-invasive, chronic treatment of bacterial layers (fouling) that might form under cranial implants, without causing adverse thermal damage to the underlying host tissue when appropriate laser parameters are used. Lasers Surg. Med. 48:782-789, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Biofilmes/efeitos da radiação , Escherichia coli/efeitos da radiação , Lasers , Nanopartículas/microbiologia , Procedimentos Neurocirúrgicos/instrumentação , Próteses e Implantes/microbiologia , Ítrio , Zircônio
4.
Nanomedicine ; 9(3): 356-65, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22960192

RESUMO

Though gold nanoparticles have been considered bio-inert, recent studies have questioned their safety. To reduce the potential for toxicity, we developed a nanoclustering of gold and iron oxide as a nanoparticle (nanorose) which biodegrades into subunits to facilitate rapid excretion. In this present study, we demonstrate acid and macrophage lysosomal degradation of nanorose via loss of the near-infrared optical shift, and clearance of the nanorose in vivo following i.v. administration in C57BL/6 mice by showing gold concentration is significantly reduced in 11 murine tissues in as little as 31 days (P < 0.01). Hematology and chemistry show no toxicity of nanorose injected mice up to 14 days after administration. We conclude that the clustering design of nanorose does enhance the excretion of these nanoparticles, and that this could be a viable strategy to limit the potential toxicity of gold nanoparticles for clinical applications. FROM THE CLINICAL EDITOR: The potential toxicity of nanomaterials is a critically important limiting factor in their more widespread clinical application. Gold nanoparticles have been classically considered bio-inert, but recent studies have questioned their safety. The authors of this study have developed a clustering gold and iron oxide nanoparticle (nanorose), which biodegrades into subunits to facilitate rapid excretion, resulting in reduced toxicity.


Assuntos
Ouro/toxicidade , Ferro/toxicidade , Nanopartículas Metálicas/toxicidade , Testes de Toxicidade , Ácidos/química , Animais , Células Cultivadas , Ouro/administração & dosagem , Concentração de Íons de Hidrogênio , Injeções Intravenosas , Ferro/administração & dosagem , Luz , Macrófagos/efeitos dos fármacos , Macrófagos/metabolismo , Macrófagos/ultraestrutura , Nanopartículas Metálicas/administração & dosagem , Nanopartículas Metálicas/ultraestrutura , Camundongos , Camundongos Endogâmicos C57BL , Espalhamento de Radiação , Soluções , Espectrofotometria Ultravioleta , Fatores de Tempo
5.
ACS Appl Bio Mater ; 5(6): 2664-2675, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35671525

RESUMO

Transparent yttria-stabilized zirconia (YSZ) ceramics are promising for cranial window applications because of their good mechanical and optical properties as well as biocompatibility. YSZ discs with different yttria concentrations were either processed via current-activated pressure-assisted densification (CAPAD) using commercial nanoparticles or densified via spark plasma sintering (SPS) using pyrolysis-synthesized nanoparticles in-house. This study provided critical results to screen composition, processing, microstructure, and cytocompatibility of transparent YSZ discs for cranial window applications. CAPAD-processed YSZ discs with 6 or 8 mol % yttria (6YSZ and 8YSZ) and SPS-densified YSZ discs with 4 mol % yttria (4YSZ_P) showed 200-350 nm polycrystalline grains containing 20-30 nm crystallite domains. SPS-densified YSZ discs with 8 mol % yttria (8YSZ_P) showed larger polycrystalline grains of 819 ± 155 nm with 29 ± 5 nm crystallite domains. CAPAD-processed YSZ discs with 3 mol % yttria (3YSZ) showed 39 ± 9 nm grains. Bone-marrow-derived stem cells (BMSCs) on the polished YSZ discs showed statistically higher spreading areas than those on the unpolished YSZ discs of the same compositions. Generally, polished 8YSZ, 4YSZ_P, and 8YSZ_P discs and unpolished 8YSZ_R, 4YSZ_PR, and 8YSZ_PR discs had lower average cell adhesion densities than other YSZ discs under direct contact conditions. Under indirect contact conditions, all the YSZ disc groups showed similar average cell adhesion densities to the Cell-only control. The groups of polished 4YSZ_P and 8YSZ_P discs, unpolished 4YSZ_PR and 8YSZ_PR discs, and particle control of 8YSZ_Pnp showed higher Y3+ ion concentrations than other groups. No mineral deposition was detected on the polished YSZ discs after cell culture. Considering multiple factors such as cytocompatibility, cell adhesion density, Y3+ ion release, mineral deposition, and optical transparency collectively, 8YSZ may be the best candidate for the cranial window applications. Further studies are needed to evaluate the long-term transparency and biocompatibility of YSZ discs.


Assuntos
Ítrio , Zircônio , Cerâmica , Ítrio/química , Zircônio/química
6.
Front Bioeng Biotechnol ; 9: 619686, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33869149

RESUMO

Transparent "Window to the Brain" (WttB) cranial implants made from a biocompatible ceramic, nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), were recently reported. These reports demonstrated chronic brain imaging across the implants in mice using optical coherence tomography (OCT) and laser speckle imaging. However, optical properties of these transparent cranial implants are neither completely characterized nor completely understood. In this study, we measure optical properties of the implant using a swept source OCT system with a spectral range of 136 nm centered at 1,300 nm to characterize the group refractive index of the nc-YSZ window, over a narrow range of temperatures at which the implant may be used during imaging or therapy (20-43°C). Group refractive index was found to be 2.1-2.2 for OCT imaging over this temperature range. Chromatic dispersion for this spectral range was observed to vary over the sample, sometimes flipping signs between normal and anomalous dispersion. These properties of nc-YSZ should be considered when designing optical systems and procedures that propagate light through the window, and when interpreting OCT brain images acquired across the window.

7.
J Biomed Mater Res B Appl Biomater ; 108(3): 709-716, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31172661

RESUMO

The "Window to the Brain" is a transparent cranial implant under development, based on nanocrystalline yttria-stabilized zirconia (nc-YSZ) transparent ceramic material. Previous work has demonstrated the feasibility of this material to facilitate brain imaging over time, but the long-term stability of the material over decades in the body is unknown. In this study, the low-temperature degradation (LTD) of nc-YSZ of 3, 6, and 8 mol % yttria is compared before and after accelerated ageing treatments following ISO standards for assessing the ageing resistance of zirconia ceramics. After 100 hr of accelerated ageing (equivalent to many decades of ageing in the body), the samples do not show any signs of phase transformation to monoclinic by X-ray diffraction and micro-Raman spectroscopy. Moreover, the mechanical hardness of the samples did not decrease, and changes in optical transmittance from 500 to 1000 nm due to ageing treatments was minimal (below 3% for all samples), and unlikely to be due to phase transformation of surface crystals to monoclinic. These results indicate the nc-YSZ has excellent ageing resistance and can withstand long-term implantation conditions without exhibiting LTD.


Assuntos
Cerâmica/química , Nanopartículas/química , Próteses e Implantes , Ítrio/química , Zircônio/química , Cerâmica/metabolismo , Cristalização , Dureza , Temperatura Alta , Humanos , Teste de Materiais , Nanopartículas/metabolismo , Transição de Fase , Pressão , Crânio , Propriedades de Superfície , Difração de Raios X , Ítrio/metabolismo , Zircônio/metabolismo
8.
Artigo em Inglês | MEDLINE | ID: mdl-32695757

RESUMO

Repeated non-diffuse optical imaging of the brain is difficult. This is due to the fact that the cranial bone is highly scattering and thus a strong optical barrier. Repeated craniotomies increase the risk of complications and may disrupt the biological systems being imaged. We previously introduced a potential solution in the form of a transparent ceramic cranial implant called the Window to the Brain (WttB) implant. This implant is made of nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), which possesses the requisite mechanical strength to serve as a permanent optical access window in human patients. In this present study, we demonstrate repeated brain imaging of n = 5 mice using both OCT and LSI across the WttB implant over 4 weeks. The main objectives are to determine if the WttB implant allows for chronic OCT imaging, and to shed further light on the question of whether optical access provided by the WttB implant remains stable over this duration in the body. The Window to the Brain implant allowed for stable repeated imaging of the mouse brain with Optical Coherence Tomography over 28 days, without loss of signal intensity. Repeated Laser Speckle Imaging was also possible over this timeframe, but signal to noise ratio and the sharpness of vessels in the images decreased with time. This can be partially explained by elevated blood flow during the first imaging session in response to trauma from the surgery, which was also detected by OCT flow imaging. These results are promising for long-term optical access through the WttB implant, making feasible chronic in vivo studies in multiple neurological models of brain disease.

9.
Biomed Opt Express ; 9(10): 4879-4892, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30319909

RESUMO

Laser speckle imaging (LSI) of mouse cerebral blood flow was compared through a transparent nanocrystalline yttria-stabilized zirconia (nc-YSZ) cranial implant over time (at days 0, 14, and 28, n = 3 mice), and vs. LSI through native skull (at day 60, n = 1 mouse). The average sharpness of imaged vessels was found to remain stable, with relative change in sharpness under 7.69% ± 1.2% over 28 days. Through-implant images of vessels at day 60 appeared sharper and smaller on average, with microvessels clearly visible, compared to through-skull images where vessels appeared blurred and distorted. These results suggest that long-term imaging through this implant is feasible.

10.
J Biomed Opt ; 20(11): 115002, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26538329

RESUMO

The ability to distinguish macrophage subtypes noninvasively could have diagnostic potential in cancer, atherosclerosis, and diabetes, where polarized M1 and M2 macrophages play critical and often opposing roles. Current methods to distinguish macrophage subtypes rely on tissue biopsy. Optical imaging techniques based on light scattering are of interest as they can be translated into biopsy-free strategies. Because mitochondria are relatively strong subcellular light scattering centers, and M2 macrophages are known to have enhanced mitochondrial biogenesis compared to M1, we hypothesized that M1 and M2 macrophages may have different angular light scattering profiles. To test this, we developed an in vitro angle-resolved forward light scattering measurement system. We found that M1 and M2 macrophage monolayers scatter relatively unequal amounts of light in the forward direction between 1.6 deg and 3.2 deg with M2 forward scattering significantly more light than M1 at increasing angles. The ratio of forward scattering can be used to identify the polarization state of macrophage populations in culture.


Assuntos
Macrófagos/citologia , Macrófagos/fisiologia , Microscopia de Contraste de Fase/instrumentação , Nefelometria e Turbidimetria/instrumentação , Refratometria/instrumentação , Animais , Células Cultivadas , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Macrófagos/classificação , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
11.
JACC Cardiovasc Imaging ; 8(1): 63-72, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25499133

RESUMO

OBJECTIVES: This study hypothesized that bright spots in intravascular optical coherence tomography (IVOCT) images may originate by colocalization of plaque materials of differing indexes of refraction. To quantitatively identify bright spots, we developed an algorithm that accounts for factors including tissue depth, distance from light source, and signal-to-noise ratio. We used this algorithm to perform a bright spot analysis of IVOCT images and compared these results with histological examination of matching tissue sections. BACKGROUND: Bright spots are thought to represent macrophages in IVOCT images, and studies of alternative etiologies have not been reported. METHODS: Fresh human coronary arteries (n = 14 from 10 hearts) were imaged with IVOCT in a mock catheterization laboratory and then processed for histological analysis. The quantitative bright spot algorithm was applied to all images. RESULTS: Results are reported for 1,599 IVOCT images co-registered with histology. Macrophages alone were responsible for only 23% of the bright spot-positive regions, although they were present in 57% of bright spot-positive regions (as determined by histology). Additional etiologies for bright spots included cellular fibrous tissue (8%), interfaces between calcium and fibrous tissue (10%), calcium and lipids (5%), and fibrous cap and lipid pool (3%). Additionally, we showed that large pools of macrophages in CD68(+) histology sections corresponded to dark regions in comparative IVOCT images; this is due to the fact that a pool of lipid-rich macrophages will have the same index of refraction as a pool of lipid and thus will not cause bright spots. CONCLUSIONS: Bright spots in IVOCT images were correlated with a variety of plaque components that cause sharp changes in the index of refraction. Algorithms that incorporate these correlations may be developed to improve the identification of some types of vulnerable plaque and allow standardization of IVOCT image interpretation.


Assuntos
Vasos Coronários/patologia , Macrófagos/patologia , Tomografia de Coerência Óptica , Algoritmos , Humanos
12.
J Biomed Opt ; 19(12): 126017, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25545341

RESUMO

We sought to elucidate the mechanisms underlying two common intravascular optical coherence tomography (IV-OCT) artifacts that occur when imaging metallic stents: "merry-go-rounding" (MGR), which is an increase in strut arc length (SAL), and "blooming," which is an increase in the strut reflection thickness (blooming thickness). Due to uncontrollable variables that occur in vivo, we performed an in vitro assessment of MGR and blooming in stented vessel phantoms. Using Xience V and Driver stents, we examined the effects of catheter offset, intimal strut coverage, and residual blood on SAL and blooming thickness in IV-OCT images. Catheter offset and strut coverage both caused minor MGR, while the greatest MGR effect resulted from light scattering by residual blood in the vessel lumen, with 1% hematocrit (Hct) causing a more than fourfold increase in SAL compared with saline (p<0.001 ). Residual blood also resulted in blooming, with blooming thickness more than doubling when imaged in 0.5% Hct compared with saline (p<0.001 ). We demonstrate that a previously undescribed mechanism, light scattering by residual blood in the imaging field, is the predominant cause of MGR. Light scattering also results in blooming, and a newly described artifact, three-dimensional-MGR, which results in "ghost struts" in B-scans.


Assuntos
Artefatos , Procedimentos Endovasculares/métodos , Tomografia de Coerência Óptica/métodos , Animais , Fenômenos Fisiológicos Sanguíneos , Processamento de Imagem Assistida por Computador , Lasers , Luz , Modelos Cardiovasculares , Imagens de Fantasmas , Reprodutibilidade dos Testes , Espalhamento de Radiação , Stents , Suínos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa