Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786511

RESUMO

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Hemodinâmica/fisiologia , Bloqueio de Ramo , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Função Ventricular Esquerda/fisiologia , Estimulação Cardíaca Artificial
2.
Heart Lung Circ ; 32(10): 1198-1206, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37634968

RESUMO

BACKGROUND: Atrial myopathy may underlie the progression of atrial fibrillation (AF) from a treatable disease to an irreversible condition with poor ablation outcomes. Electrophysiological methods to unmask areas prone to re-entry initiation could be key to defining latent atrial myopathy. METHODS: Consecutive patients referred for AF ablation were prospectively included at four institutions. Decrement evoked potential mapping (DEEP) was performed in eight left atrial sites and five right atrial sites, from two different pacing locations (endocardially from the left atrial appendage, epicardially from the proximal coronary sinus). The electrograms (EGMs) during S1 600 ms drive and after an extra stimulus (S2 at +30 ms above atrial refractoriness) were studied at each location and assessed for decremental properties. Follow-up was 12 months. RESULTS: Seventy-four patients were included and 85% had persistent AF. A total of 17,614 EGMs were individually analysed and measured. Nine percent of the EGMs showed DEEP properties (local delay of >10 ms after S2) with a mean decrement of 33±26 ms. DEEPs were more frequent in the left atrium than the right atrium (9.4% vs 8.0%; p<0.001) and more prevalent in persistent AF patients than paroxysmal AF patients (9.8% vs 4.6% p=0.001). Atrial DEEPs were more frequently unmasked in normal bipolar voltage areas and by epicardial pacing than endocardial pacing (9.6% vs 8.4%, respectively; p=0.004). Within the left atrium, the roof had the highest prevalence of DEEP EGMs. CONCLUSIONS: DEEP mapping of both atria is useful for highlighting areas with a tendency for unidirectional block and re-entry initiation. Those areas are more easily unmasked by epicardial pacing from the coronary sinus and more prevalent in persistent AF patients than in paroxysmal AF patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Doenças Musculares , Humanos , Átrios do Coração , Apêndice Atrial/cirurgia , Doenças Musculares/cirurgia , Potenciais Evocados
3.
Eur Heart J ; 41(47): 4471-4480, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-32860414

RESUMO

AIMS: Long-standing persistent atrial fibrillation (LSPAF) is challenging to treat with suboptimal catheter ablation (CA) outcomes. Thoracoscopic surgical ablation (SA) has shown promising efficacy in atrial fibrillation (AF). This multicentre randomized controlled trial tested whether SA was superior to CA as the first interventional strategy in de novo LSPAF. METHODS AND RESULTS: We randomized 120 LSPAF patients to SA or CA. All patients underwent predetermined lesion sets and implantable loop recorder insertion. Primary outcome was single procedure freedom from AF/atrial tachycardia (AT) ≥30 s without anti-arrhythmic drugs at 12 months. Secondary outcomes included clinical success (≥75% reduction in AF/AT burden); procedure-related serious adverse events; changes in patients' symptoms and quality-of-life scores; and cost-effectiveness. At 12 months, freedom from AF/AT was recorded in 26% (14/54) of patients in SA vs. 28% (17/60) in the CA group [OR 1.128, 95% CI (0.46-2.83), P = 0.83]. Reduction in AF/AT burden ≥75% was recorded in 67% (36/54) vs. 77% (46/60) [OR 1.13, 95% CI (0.67-4.08), P = 0.3] in SA and CA groups, respectively. Procedure-related serious adverse events within 30 days of intervention were reported in 15% (8/55) of patients in SA vs. 10% (6/60) in CA, P = 0.46. One death was reported after SA. Improvements in AF symptoms were greater following CA. Over 12 months, SA was more expensive and provided fewer quality-adjusted life-years (QALYs) compared with CA (0.78 vs. 0.85, P = 0.02). CONCLUSION: Single procedure thoracoscopic SA is not superior to CA in treating LSPAF. Catheter ablation provided greater improvements in symptoms and accrued significantly more QALYs during follow-up than SA. CLINICAL TRIAL REGISTRATION: ISRCTN18250790 and ClinicalTrials.gov: NCT02755688.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Humanos , Anos de Vida Ajustados por Qualidade de Vida , Recidiva , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 30(4): 520-527, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30614114

RESUMO

BACKGROUND: Noninvasive electrocardiographic mapping of ventricular tachycardia (VT) and ablation using stereotactic radiotherapy was recently reported. This strategy does not directly evaluate the critical diastolic components and assumes that the epicardial exit site of VT subtends closely over the endocardial mid-diastolic isthmus. OBJECTIVE: To determine if the epicardial exit site of VT spatially corresponds to the critical diastolic components of ischemic scar-related VT. MATERIALS AND METHODS: Intraoperative simultaneous endocardial and epicardial mapping were performed during VT using a 112-bipole endocardial balloon and 112-bipole epicardial sock array. In eight patients, nine VTs having entire diastolic circuit mapped were included in the study. The diastolic path and VT-exit sites (epicardial and endocardial) were determined. RESULTS: The diastolic path was mapped in the endocardium for all nine VTs (median length, 50; interquartile range [IQR], 28 mm). The tachycardia cycle length ranged from 210-500 ms. The VT-exit site was early in the endocardium for six VTs and on the epicardium for three VTs. The mid-diastolic isthmus and endocardial exit site of the six endocardial VTs were spatially distant from their epicardial exit site by a median distance of 32 and 27 mm, respectively. For the three VTs with an early epicardial exit, the isthmus and endocardial exit sites were distant from the epicardial exit site by a median distance of 34 and 38 mm, respectively. CONCLUSION: The epicardial exit site and the mid-diastolic isthmus sites were spatially distant and discrepant. Surface electrocardiography (ECG)-derived strategy in identifying epicardial exit site to select noninvasive ablation targets is prone to identify epicardial exit sites and may not identify critical targets in ischemic scar VT.


Assuntos
Ablação por Cateter , Endocárdio/fisiopatologia , Frequência Cardíaca , Isquemia Miocárdica/complicações , Pericárdio/fisiopatologia , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
5.
Europace ; 20(3): 451-458, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28108547

RESUMO

Aims: Characterizing the differences in substrate and clinical outcome between heart failure (HF) and non-heart failure (non-HF) patients undergoing persistent atrial fibrillation (AF) ablation. Methods and results: Using complex fractionated electrograms (CFE) as a surrogate marker of substrate complexity, we compared the bi-atrial substrate in patients with persistent AF with and without HF, at baseline and after ablation, to determine its impact on clinical outcome. In this retrospective analysis of two prospective studies, 60 patients underwent de-novo step-wise left atrial (LA) ablation, 30 with normal left ventricular ejection fraction (LVEF) ≥ 50% (non-HF group) and 30 with LVEF ≤ 35% (HF group). Multiple high-density bi-atrial CFE maps were acquired along with AF cycle length (AFCL) at each procedural stage. Change in bi-atrial CFE areas, AFCL and outcome data were then compared. In the non-HF group, higher CFE-areas were found at baseline and at each step of the procedure in the LA. In both LA and the right atrium (RA), baseline and final CFE area were also higher in the non-HF group. Single procedure, arrhythmia-free survival at 1 year was higher in the HF group compared with the non-HF group (72% vs. 43%, log rank P = 0.04). Final total bi-atrial CFE area was an independent predictor of arrhythmia recurrence. Conclusions: CFE represents an important surrogate marker of atrial substrate complexity. The atrial substrate in persistent AF differs between HF and non-HF with the latter representing a more complex 'primary' bi-atrial myopathy. LA focussed ablation results in more extensive substrate modification in HF and better clinical outcomes as compared with non-HF.


Assuntos
Fibrilação Atrial/complicações , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/complicações , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Sistema de Condução Cardíaco/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Intervalo Livre de Progressão , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Eur Heart J ; 37(46): 3470-3482, 2016 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-26935273

RESUMO

AIMS: The aim of this study was to analyse randomized controlled study and real-world outcomes of patients with non-valvular atrial fibrillation (NVAF) undergoing left atrial appendage closure (LAAC) with the Watchman device and to compare costs with available antithrombotic therapies. METHODS AND RESULTS: Registry data of LAAC from two centres were prospectively collected from 110 patients with NVAF at risk of stroke, suitable and unsuitable for long-term anticoagulation (age 71.3 ± 9.2 years, CHADS2 2.8 ± 1.2, CHA2DS2-VASc 4.5 ± 1.6, and HAS-BLED 3.8 ± 1.1). Outcomes from PROTECT AF and registry study LAAC were compared with warfarin, dabigatran, rivaroxaban, apixaban, aspirin, and no treatment using a network meta-analysis. Costs were estimated over a 10-year horizon. Uncertainty was assessed using sensitivity analyses. The procedural success rate was 92% (103/112). Follow-up was 24.1 ± 4.6 months, during which annual rates of stroke, major bleeding, and all-cause mortality were 0.9% (2/223 patient-years), 0.9% (2/223 patient-years), and 1.8% (4/223 patient-years), respectively. Anticoagulant therapy was successfully stopped in 91.2% (93/102) of implanted patients by 12 months. Registry study LAAC stroke and major bleeding rates were significantly lower than PROTECT AF results: mean absolute difference of stroke, 0.89% (P = 0.02) and major bleeding, 5.48% (P < 0.001). Left atrial appendage closure achieved cost parity between 4.9 years vs. dabigatran 110 mg and 8.4 years vs. warfarin. At 10 years, LAAC was cost-saving against all therapies (range £1162-£7194). CONCLUSION: Left atrial appendage closure in NVAF in a real-world setting may result in lower stroke and major bleeding rates than reported in LAAC clinical trials. Left atrial appendage closure in both settings achieves cost parity in a relatively short period of time and may offer substantial savings compared with current therapies. Savings are most pronounced among higher risk patients and those unsuitable for anticoagulation.


Assuntos
Apêndice Atrial , Anticoagulantes , Fibrilação Atrial , Humanos , Acidente Vascular Cerebral , Resultado do Tratamento , Varfarina
8.
Pacing Clin Electrophysiol ; 39(9): 926-34, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27436224

RESUMO

BACKGROUND: To investigate the effects of catheter ablation and rate control strategies on cardiac and inflammatory biomarkers in patients with heart failure and persistent atrial fibrillation (AF). METHODS: Patients were recruited from the ARC-HF trial (catheter Ablation vs Rate Control for management of persistent AF in Heart Failure, NCT00878384), which compared ablation with rate control for persistent AF in heart failure. B-type natriuretic peptide (BNP), midregional proatrial natriuretic peptide (MR-proANP), apelin, and interleukin-6 (IL-6) were assayed at baseline, 3 months, 6 months, and 12 months. The primary end point, analyzed per-protocol, was changed from baseline at 12 months. RESULTS: Of 52 recruited patients, 24 ablation and 25 rate control subjects were followed to 12 months. After 1.2 ± 0.5 procedures, sinus rhythm was present in 22 (92%) ablation patients; under rate control, rate criteria were achieved in 23 (96%) of 24 patients remaining in AF. At 12 months, MR-proANP fell significantly in the ablation arm (-106.0 pmol/L, interquartile range [IQR] -228.2 to -60.6) compared with rate control (-28.7 pmol/L, IQR -69 to +9.5, P = 0.028). BNP showed a similar trend toward reduction (P = 0.051), with no significant difference in apelin (P = 0.13) or IL-6 (P = 0.68). Changes in MR-proANP and BNP correlated with peak VO2 and ejection fraction, and MR-proANP additionally with quality-of-life score. CONCLUSIONS: Catheter ablation, compared with rate control, in patients with heart failure and persistent AF was associated with significant reduction in MR-proANP, which correlated with physiological and symptomatic improvement. Ablation-based rhythm control may induce beneficial cardiac remodeling, unrelated to changes in inflammatory state. This may have prognostic implications, which require confirmation by event end point studies.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/sangue , Fibrilação Atrial/terapia , Biomarcadores/sangue , Estimulação Cardíaca Artificial , Ablação por Cateter , Apelina , Fibrilação Atrial/diagnóstico , Fator Natriurético Atrial/sangue , Doença Crônica , Feminino , Insuficiência Cardíaca , Humanos , Peptídeos e Proteínas de Sinalização Intercelular/sangue , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Avaliação de Resultados em Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
9.
Magn Reson Med ; 73(2): 646-54, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24604664

RESUMO

PURPOSE: High resolution three-dimensional (3D) late gadolinium enhancement (LGE) imaging is performed with single R-wave gating to minimize lengthy acquisition durations. In patients with atrial fibrillation (AF), heart rate variability results in variable magnetization recovery between sequence repeats, and image quality is often poor. In this study, we implemented and tested a dynamic inversion time (dynamic-TI) scheme designed to reduce sequence sensitivity to heart rate variations. METHODS: An inversion-prepared 3D segmented gradient echo sequence was modified so that the TI varied automatically from beat-to-beat (dynamic-TI) based on the time since the last sequence repeat. 3D LGE acquisitions were performed in 17 patients prior to radio frequency ablation of persistent AF both with and without dynamic-TI. Qualitative image quality scores, blood signal-to-ghosting ratios (SGRs). and blood-myocardium contrast-to-ghosting ratios (CGRs) were compared. RESULTS: Image quality scores were higher with dynamic-TI than without dynamic-TI (2.2 ± 0.9 vs. 1.8 ± 1.1, P = 0.008), as were blood-myocardium CGRs (13.8 ± 7.6 vs. 8.3 ± 6.1, P = 0.003) and blood SGRs (19.6 ± 8.5 vs. 13.1 ± 8.0, P = 0.003). CONCLUSION: The dynamic-TI algorithm improves image quality of 3D LGE imaging in this difficult patient population by reducing the sequence sensitivity to RR interval variations


Assuntos
Algoritmos , Fibrilação Atrial/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Compostos Organometálicos , Idoso , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Cardiovasc Electrophysiol ; 26(4): 378-384, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25546580

RESUMO

INTRODUCTION: Contact force sensing (CFS) technology improves acute pulmonary vein isolation durability; however, its impact on the clinical outcome of ablating atrial fibrillation (AF) is unknown. METHODS AND RESULTS: First time AF ablation procedures employing CFS from 4 centers were matched retrospectively to those without CFS in a 1:2 manner by type of AF. Freedom from atrial tachyarrhythmia was defined as the primary outcome measure, and fluoroscopy time the secondary outcome measure. Nineteen possible explanatory variables were tested in addition to CFS. A total of 600 AF ablation procedures (200 using CFS and 400 using non-CFS catheters) performed between 2010 and 2012 (46% paroxysmal, 36% persistent, 18% long-lasting persistent) were analyzed. The mean follow-up duration was 11.4 ± 4.7 months-paroxysmal AF 11.2 ± 4.1 CFS versus 11.3 ± 3.9 non-CFS (P = 0.745)-nonparoxysmal AF 10.4 ± 4.5 CFS versus 11.9 ± 5.4 non-CFS (P = 0.015). The use of a CFS catheter independently predicted clinical success in ablating paroxysmal AF (HR 2.24 [95% CIs 1.29-3.90]; P = 0.004), but not nonparoxysmal AF (HR 0.73 [0.41-1.30]; P = 0.289) in a multivariate analysis that included follow-up duration. Among all cases, the use of CFS catheters was associated with reduced fluoroscopy time in multivariate analysis (reduction by 7.7 [5.0-10.5] minutes; P < 0.001). Complication rates were similar in both groups. CONCLUSIONS: At medium-term follow-up, CFS catheter technology is associated with significantly improved outcome of first time catheter ablation of paroxysmal AF, but not nonparoxysmal AF. Fluoroscopy time was lower when CFS technology was employed in all types of AF ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Inglaterra , Feminino , Fluoroscopia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Veias Pulmonares/fisiopatologia , Doses de Radiação , Radiografia Intervencionista/métodos , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Biomed Eng Online ; 14: 88, 2015 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-26445883

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common heart rhythm disorder. In order for late Gd enhancement cardiovascular magnetic resonance (LGE CMR) to ameliorate the AF management, the ready availability of the accurate enhancement segmentation is required. However, the computer-aided segmentation of enhancement in LGE CMR of AF is still an open question. Additionally, the number of centres that have reported successful application of LGE CMR to guide clinical AF strategies remains low, while the debate on LGE CMR's diagnostic ability for AF still holds. The aim of this study is to propose a method that reliably distinguishes enhanced (abnormal) from non-enhanced (healthy) tissue within the left atrial wall of (pre-ablation and 3 months post-ablation) LGE CMR data-sets from long-standing persistent AF patients studied at our centre. METHODS: Enhancement segmentation was achieved by employing thresholds benchmarked against the statistics of the whole left atrial blood-pool (LABP). The test-set cross-validation mechanism was applied to determine the input feature representation and algorithm that best predict enhancement threshold levels. RESULTS: Global normalized intensity threshold levels T PRE  = 1 1/4 and T POST  = 1 5/8 were found to segment enhancement in data-sets acquired pre-ablation and at 3 months post-ablation, respectively. The segmentation results were corroborated by using visual inspection of LGE CMR brightness levels and one endocardial bipolar voltage map. The measured extent of pre-ablation fibrosis fell within the normal range for the specific arrhythmia phenotype. 3D volume renderings of segmented post-ablation enhancement emulated the expected ablation lesion patterns. By comparing our technique with other related approaches that proposed different threshold levels (although they also relied on reference regions from within the LABP) for segmenting enhancement in LGE CMR data-sets of AF patients, we illustrated that the cut-off levels employed by other centres may not be usable for clinical studies performed in our centre. CONCLUSIONS: The proposed technique has great potential for successful employment in the AF management within our centre. It provides a highly desirable validation of the LGE CMR technique for AF studies. Inter-centre differences in the CMR acquisition protocol and image analysis strategy inevitably impede the selection of a universally optimal algorithm for segmentation of enhancement in AF studies.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/patologia , Meios de Contraste , Gadolínio , Átrios do Coração/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Técnicas de Ablação , Algoritmos , Fibrilação Atrial/terapia , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador
12.
Pacing Clin Electrophysiol ; 37(11): 1427-35, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25220575

RESUMO

BACKGROUND: Catheter-based contact force sensing (CFS) technology gives detailed information regarding contact between the catheter tip and myocardium. This may result in more effective ablation procedures. The primary objective of this study was comparison of remote robotic navigation (RRN) and Manual CFS ablation. The secondary objective was to compare CFS with non-CFS ablation for both navigation modes. METHODS: Prospective registries of consecutive cases undergoing their first ablation for persistent atrial fibrillation (AF) from six hospitals in the United Kingdom and South Africa were analyzed: 50 Manual/CFS and 50 RRN/CFS cases were included. Historical control non-CFS ablation patients were matched by propensity score, giving a total 200 patient cohort. RESULTS: RRN/CFS was associated with improved single procedure 1-year success rates (64% vs 36%, P = 0.01) and shorter fluoroscopy times (41% reduction, P < 0.0005) than Manual/CFS ablation, without any difference in procedure times (P = 0.8). The mean contact force was higher in RRN/CFS than Manual/CFS cases (16 [15-18 g] vs 13 [12-15 g], respectively, P = 0.003). Compared with non-CFS historical controls, CFS cases had higher 1-year success rates for RRN (64% vs 36%, P = 0.01), but not Manual ablation (36% vs 38%, P = 1). Procedure times were reduced for CFS cases (20%, P < 0.005 both navigation modes), as were fluoroscopy times (Manual: 43%, RRN 83%, P < 0.005 for both). There were no differences in rates of major or minor complications for either comparison (P > 0.5). CONCLUSIONS: A combination of RRN and CFS is associated with improved success rates at 1 year and fluoroscopy times for persistent AF ablation, compared with Manual ablation and non-CFS RRN ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Procedimentos Cirúrgicos Robóticos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros
13.
Eur Heart J ; 39(25): 2337-2338, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30052946
14.
Eur Heart J ; 39(37): 3410, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31222217
15.
Eur Heart J Digit Health ; 5(3): 344-355, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774381

RESUMO

Aims: This proof-of-concept study sought to evaluate changes in heart rate (HR) obtained from a consumer wearable device and compare against implantable loop recorder (ILR)-detected recurrence of atrial fibrillation (AF) and atrial tachycardia (AT) after AF ablation. Methods and results: REMOTE-AF (NCT05037136) was a prospectively designed sub-study of the CASA-AF randomized controlled trial (NCT04280042). Participants without a permanent pacemaker had an ILR implanted at their index ablation procedure for longstanding persistent AF. Heart rate and step count were continuously monitored using photoplethysmography (PPG) from a commercially available wrist-worn wearable. Photoplethysmography-recorded HR data were pre-processed with noise filtration and episodes at 1-min interval over 30 min of HR elevations (Z-score = 2) were compared with corresponding ILR data. Thirty-five patients were enrolled, with mean age 70.3 ± 6.8 years and median follow-up 10 months (interquartile range 8-12 months). Implantable loop recorder analysis revealed 17 out of 35 patients (49%) had recurrence of AF/AT. Compared with ILR recurrence, wearable-derived elevations in HR ≥ 110 beats per minute had a sensitivity of 95.3%, specificity 54.1%, positive predictive value (PPV) 15.8%, negative predictive value (NPV) 99.2%, and overall accuracy 57.4%. With PPG-recorded HR elevation spikes (non-exercise related), the sensitivity was 87.5%, specificity 62.2%, PPV 39.2%, NPV 92.3%, and overall accuracy 64.0% in the entire patient cohort. In the AF/AT recurrence only group, sensitivity was 87.6%, specificity 68.3%, PPV 53.6%, NPV 93.0%, and overall accuracy 75.0%. Conclusion: Consumer wearable devices have the potential to contribute to arrhythmia detection after AF ablation. Study Registration: ClinicalTrials.gov Identifier: NCT05037136 https://clinicaltrials.gov/ct2/show/NCT05037136.

16.
Heart Rhythm ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38763376

RESUMO

BACKGROUND: Long-term clinical outcomes of catheter ablation (CA) compared to thoracoscopic surgical ablation (SA) to treat patients with long-standing persistent atrial fibrillation (LSPAF) are not known. OBJECTIVE: The purpose of this study was to compare the long-term (36-month) clinical efficacy, quality of life, and cost-effectiveness of SA and CA in LSPAF. METHODS: Participants were followed up for 3 years using implantable loop recorders and questionnaires to assess the change in quality of life. Intention-to-treat analyses were used to report the findings. RESULTS: Of the 115 patients with LSPAF treated, 104 (90.4%) completed 36-month follow-up [CA: n = 57 (95%); SA: n = 47 (85%)]. After a single procedure without antiarrhythmic drugs, 7 patients (12%) in the CA arm and 5 (11%) in the SA arm [hazard ratio 1.22; 95% confidence interval (CI) 0.81-1.83; P = .41] were free from atrial fibrillation/tachycardia (AF/AT) ≥30 seconds at 36 months. Thirty-three patients (58%) in the CA arm and 26 (55%) in the SA arm (hazard ratio 1.04; 95% CI 0.57-1.88; P = .91) had their AF/AT burden reduced by ≥75%. The overall impact on health-related quality of life was similar, with mean quality-adjusted life year estimates of 2.45 (95% CI 2.31-2.59) for CA and 2.32 (95% CI 2.13-2.52) for SA. Estimated costs were higher for SA (mean £24,682; 95% CI £21,746-£27,618) than for CA (mean £18,002; 95% CI £15,422-£20,581). CONCLUSION: In symptomatic LSPAF, CA and SA were equally effective at achieving arrhythmia outcomes (freedom from AF/AT ≥30 seconds and ≥75% burden reduction) after a single procedure without antiarrhythmic drugs. However, SA is significantly more costly than CA. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT04280042.

17.
Clin Med (Lond) ; 23(5): 437-441, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37775166

RESUMO

Atrial fibrillation (AF) is the most common cardiac arrhythmia and imposes a significant healthcare burden. The landscape of AF has changed considerably over the past few years, with the advent of novel diagnostic approaches, advances in therapies and changing recommendations on best practice from the latest major trials. In this article, we review our evolving understanding of the natural history of AF and explore the contemporary landscape of its diagnosis and management.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia
18.
Eur Heart J Case Rep ; 7(8): ytad380, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37637090

RESUMO

Background: Mitral regurgitation may develop or worsen following right ventricular apical pacing due to dyssynchronous left ventricular contraction. Pre-existing secondary mitral annular dilation is a well-recognized and important contributing factor. This description of pacing-induced torrential mitral regurgitation in the setting of rheumatic mitral valve disease is a rare case in which a primary mitral valve lesion was the antecedent mechanism. Case summary: A 60-year-old man was admitted with dizziness and pre-syncope. Twelve-lead electrocardiogram showed complete heart block. A dual-chamber pacemaker was implanted and programmed in DDD mode. Transthoracic echocardiography performed a day later demonstrated a left ventricular ejection fraction (LVEF) of 63% and moderate mitral regurgitation. The patient presented 4 months later with breathlessness and orthopnoea. Pacemaker interrogation demonstrated a 98% right ventricular pacing burden. Echocardiography revealed torrential mitral regurgitation secondary to left ventricular dyssynchrony and complete loss of leaflet coaptation with preserved systolic function. Post-capillary pulmonary hypertension was diagnosed following right heart catheterization. The patient underwent metallic mitral valve replacement, tricuspid annuloplasty, and left internal mammary artery grafting to the left anterior descending artery for a severe proximal stenosis. On inspection, the native mitral valve was notably rheumatic in appearance, and this was confirmed histologically. Discussion: It is important to closely monitor the progression of mitral regurgitation in those with primary mitral valve disease undergoing right ventricular pacing. Early follow-up may prevent the adverse haemodynamic consequences of worsening mitral regurgitation, with a greater chance of recovery of left ventricular function following surgery.

19.
Circ Cardiovasc Imaging ; 16(6): e015352, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37288553

RESUMO

BACKGROUND: Left atrial (LA) function following catheter or surgical ablation of de-novo long-standing persistent atrial fibrillation (AF) and its impact on AF recurrence was studied in patients participating in the CASA-AF trial (Catheter Ablation vs. Thoracoscopic Surgical Ablation in Long Standing Persistent Atrial Fibrillation). METHODS: All patients underwent echocardiography preablation, 3 and 12 months post-ablation. LA structure and function were assessed by 2-dimensional volume and speckle tracking strain measurements of LA reservoir, conduit, and contractile strain. Left ventricular diastolic function was measured using transmitral Doppler filling velocities and myocardial tissue Doppler velocities to derive the e', E/e', and E/A ratios. Continuous rhythm monitoring was achieved using an implantable loop recorder. RESULTS: Eighty-three patients had echocardiographic data suitable for analysis. Their mean age was 63.6±9.7 years, 73.5% were male, had AF for 22.8±11.6 months, and had a mean LA maximum volume of 48.8±13.8 mL/m2. Thirty patients maintained sinus rhythm, and 53 developed AF recurrence. Ablation led to similar reductions in LA volumes at follow-up in both rhythm groups. However, higher LA emptying fraction (36.3±10.6% versus 27.9±9.9%; P<0.001), reservoir strain (22.6±8.5% versus 16.7±5.7%; P=0.001), and contractile strain (9.2±3.4% versus 5.6±2.5%; P<0.001) were noted in the sinus rhythm compared with AF recurrence group following ablation at 3 months. Diastolic function was better in the sinus rhythm compared with the AF recurrence group with an E/A ratio of 1.5±0.5 versus 2.2±1.2 (P<0.001) and left ventricular E/e' ratio of 8.0±2.1 versus 10.3±4.1 (P<0.001), respectively. LA contractile strain at 3 months was the only independent predictor of AF recurrence. CONCLUSIONS: Following ablation for long-standing persistent AF, improvement in LA function was greater in those who maintained sinus rhythm. LA contractile strain at 3 months was the most important determinant of AF recurrence following ablation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02755688.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/métodos , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Recidiva , Resultado do Tratamento
20.
Clin Res Cardiol ; 111(6): 680-691, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34999932

RESUMO

BACKGROUND: A high proportion of patients undergoing catheter ablation (CA) for atrial fibrillation (AF) experience recurrence of arrhythmia. This meta-analysis aims to identify pre-ablation serum biomarker(s) associated with arrhythmia recurrence to improve patient selection before CA. METHODS: A systematic approach following PRISMA reporting guidelines was utilised in libraries (Pubmed/Medline, Embase, Web of Science, Scopus) and supplemented by scanning through bibliographies of articles. Biomarker levels were compared using a random-effects model and presented as odds ratio (OR). Heterogeneity was examined by meta-regression and subgroup analysis. RESULTS: In total, 73 studies were identified after inclusion and exclusion criteria were applied. Nine out of 22 biomarkers showed association with recurrence of AF after CA. High levels of N-Terminal-pro-B-type-Natriuretic Peptide [OR (95% CI), 3.11 (1.80-5.36)], B-type Natriuretic Peptide [BNP, 2.91 (1.74-4.88)], high-sensitivity C-Reactive Protein [2.04 (1.28-3.23)], Carboxy-terminal telopeptide of collagen type I [1.89 (1.16-3.08)] and Interleukin-6 [1.83 (1.18-2.84)] were strongly associated with identifying patients with AF recurrence. Meta-regression highlighted that AF type had a significant impact on BNP levels (heterogeneity R2 = 55%). Subgroup analysis showed that high BNP levels were more strongly associated with AF recurrence in paroxysmal AF (PAF) cohorts compared to the addition of non-PAF patients. Egger's test ruled out the presence of publication bias from small-study effects. CONCLUSION: Ranking biomarkers based on the strength of association with outcome provides each biomarker relative capacity to predict AF recurrence. This will provide randomised controlled trials, a guide to choosing a priori tool for identifying patients likely to revert to AF, which are required to substantiate these findings.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Biomarcadores , Proteína C-Reativa , Humanos , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS