Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Lancet ; 397(10288): 1895-1904, 2021 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-33971152

RESUMO

BACKGROUND: Molecular imaging is increasingly used to guide treatment decisions and planning in prostate cancer. We aimed to evaluate the role of 18F-fluciclovine-PET/CT in improving cancer control compared with conventional imaging (bone scan and either CT or MRI) alone for salvage postprostatectomy radiotherapy. METHODS: In EMPIRE-1, a single-centre, open-label, phase 2/3 randomised controlled trial, patients with prostate cancer with detectable PSA after prostatectomy and negative conventional imaging (no extrapelvic or bone findings) were randomly assigned in a 1:1 ratio to radiotherapy directed by conventional imaging alone or to conventional imaging plus 18F-fluciclovine-PET/CT. Computer-generated randomisation was stratified by PSA concentration, adverse pathology indicators, and androgen deprivation therapy intent. In the 18F-fluciclovine-PET/CT group, radiotherapy decisions were rigidly determined by PET findings, which were also used for target delineation. The primary endpoint was 3 year event-free survival, with events defined as biochemical or clinical recurrence or progression, or initiation of systemic therapy, using univariate and multivariable analyses in patients who received radiotherapy. This trial is registered with ClinicalTrials.gov, NCT01666808 and is closed to new participants. FINDINGS: From Sept 18, 2012, to March 4, 2019, 165 patients were randomly assigned, with median follow-up of 3·52 years (95% CI 2·98-3·95). PET findings resulted in four patients in the 18F-fluciclovine-PET/CT group having radiotherapy aborted; these patients were excluded from survival analyses. Median survival was not reached (95% CI 35·2-not reached; 33% of 81 patients had events) in the conventional imaging group compared with not reached (95% CI not reached-not reached; 20% of 76 patients) in the 18F-fluciclovine-PET/CT group, and 3 year event-free survival was 63·0% (95% CI 49·2-74·0) in the conventional imaging group versus 75·5% (95% CI 62·5-84·6) for 18F-fluciclovine-PET/CT (difference 12·5; 95% CI 4·3-20·8; p=0·0028). In adjusted analyses, study group (hazard ratio 2·04 [95% CI 1·06-3·93], p=0·0327) was significantly associated with event-free survival. Toxicity was similar in both study groups, with the most common adverse events being late urinary frequency or urgency (37 [46%] of 81 patients in the conventional imaging group and 31 [41%] of 76 in the PET group), and acute diarrhoea (11 [14%] in the conventional imaging group and 16 [21%] in the PET group). INTERPRETATION: Inclusion of 18F-fluciclovine-PET into postprostatectomy radiotherapy decision making and planning significantly improved survival free from biochemical recurrence or persistence. Integration of novel PET radiotracers into radiotherapy decisions and planning for prostate cancer patients warrants further study. FUNDING: National Institutes of Health/National Cancer Institute, Blue Earth Diagnostics, and Winship Cancer Institute of Emory University.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prostatectomia/métodos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Radiografia Intervencionista/métodos , Terapia de Salvação/métodos , Adenocarcinoma/radioterapia , Adenocarcinoma/cirurgia , Idoso , Ácidos Carboxílicos , Ciclobutanos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
2.
Radiology ; 284(1): 200-209, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28212051

RESUMO

Purpose To determine if commonly administered doses of technetium 99m (99mTc) mertiatide (MAG3) in the range of 300-370 MBq (approximately 8-10 mCi) contribute to image interpretation and justify the resulting radiation exposure. Materials and Methods The respective institutional review boards approved this HIPAA-compliant study and waived informed consent. Baseline and furosemide 99mTc-MAG3 imaging examinations in 50 patients suspected of having renal obstruction and 48 patients suspected of having renovascular hypertension (RVH) were randomly selected from archived databases and were independently scored by three experienced readers without access to 2-second flow images. Readers were blinded to their original scores, and then they rescored each examination with access to high-activity 2-second flow images. Relative renal function was determined after a low activity (62.9 MBq ± 40.7) baseline acquisition for RVH and a high activity (303.4 MBq ± 48.1) acquisition after administration of enalaprilat. Data were analyzed by using random effects analysis of variance and mean and standard error of the mean for the difference between sets of scores and the difference between relative function measurements. Results There was no significant difference in the scores without flow images compared with blinded scores with high-activity flow images for patients suspected of having obstruction (P = .80) or RVH (P = .24). Moreover, there was no significant difference in the relative uptake measurements after administration of low and high activities (P > .99). Conclusion Administered doses of 99mTc-MAG3 in the range of 300-370 MBq (approximately 8-10 mCi) do not affect the relative function measurements or contribute to interpretation of images in patients suspected of having RVH or obstruction compared with administration of lower doses; unnecessary radiation exposure can be avoided by administering doses in the range of 37-185 MBq as recommended incurrent guidelines. © RSNA, 2017.


Assuntos
Renografia por Radioisótopo/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Obstrução da Artéria Renal/diagnóstico por imagem , Tecnécio Tc 99m Mertiatida/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Semin Dial ; 30(4): 369-372, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28558417

RESUMO

Secondary hyperparathyroidism from chronic renal failure often requires a parathyroidectomy for correction. A successful parathyroidectomy often relies upon localization of all parathyroid tumors. Although most of the tumors are localized during a neck exploration, preoperative localization studies can help identify ectopic and supernumerary tumors. Three of the most common localization studies are radionuclide imaging, ultrasound, and CT scanning. Utility of these studies is strongly dependent on local institutional practice.


Assuntos
Hiperparatireoidismo Secundário/diagnóstico por imagem , Hiperparatireoidismo Secundário/etiologia , Falência Renal Crônica/complicações , Glândulas Paratireoides/diagnóstico por imagem , Humanos , Hiperparatireoidismo Secundário/cirurgia , Falência Renal Crônica/diagnóstico por imagem , Paratireoidectomia , Cintilografia , Tomografia Computadorizada por Raios X , Ultrassonografia
4.
Eur J Nucl Med Mol Imaging ; 43(10): 1773-83, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27091135

RESUMO

PURPOSE: To compare the diagnostic performance of the synthetic amino acid analogue PET radiotracer anti-3-[(18)F]FACBC (fluciclovine) with that of CT in the detection of recurrent prostate carcinoma. METHODS: This was a retrospective analysis of 53 bone scan-negative patients with suspected recurrent prostate carcinoma who underwent fluciclovine PET/CT and routine clinical CT within 90 days of each other. The correlation between imaging findings and histology and clinical follow-up was evaluated. Positivity rates and diagnostic performance were calculated for fluciclovine PET/CT and CT. RESULTS: Of 53 fluciclovine PET/CT and 53 CT examinations, 41 (77.4 %) and 10 (18.9 %), respectively, had positive findings for recurrent disease. Positivity rates were higher with fluciclovine PET/CT than with CT at all prostate-specific antigen (PSA) levels, PSA doubling times and original Gleason scores. In the prostate/bed, fluciclovine PET/CT was true-positive in 31 and CT was true-positive in 4 of 51 patients who met the reference standard. In extraprostatic regions, fluciclovine PET/CT was true-positive in 12 and CT was true-positive in 3 of 41 patients who met the reference standard. Of the 43 index lesions used to prove positivity, 42 (97.7 %) had histological proof. In 51 patients with sufficient follow-up to calculate diagnostic performance in the prostate/bed, fluciclovine PET/CT demonstrated a sensitivity of 88.6 %, a specificity of 56.3 %, an accuracy of 78.4 %, a positive predictive value (PPV) of 81.6 %, and a negative predictive value (NPV) of 69.2 %; the respective values for CT were 11.4 %, 87.5 %, 35.3 %, 66.7 % and 31.1 %. In 41 patients with sufficient follow-up to calculate diagnostic performance in extraprostatic regions, fluciclovine PET/CT demonstrated a sensitivity of 46.2 %, a specificity of 100 %, an accuracy of 65.9 %, a PPV of 100 %, and an NPV of 51.7 %; the respective values for CT were 11.5 %, 100 %, 43.9 %, 100 % and 39.5 %. CONCLUSION: The diagnostic performance of fluciclovine PET/CT in recurrent prostate cancer is superior to that of CT and fluciclovine PET/CT provides better delineation of prostatic from extraprostatic recurrence.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Ácidos Carboxílicos , Ciclobutanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/prevenção & controle , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
5.
AJR Am J Roentgenol ; 205(5): W519-31, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26496574

RESUMO

OBJECTIVE: This image-based article illustrates the anatomic regions of squamous cell carcinomas of the head and neck and describes the metastatic pathways in and TNM staging for each region. Both the role and limitations of FDG PET/CT in imaging such cancers are discussed, and cases exemplifying these issues are reported. Also included is a discussion of the use of FDG PET/CT to monitor the response of squamous cell carcinomas of the head and neck to therapy, in addition to a brief comparison of PET/CT with such traditional imaging modalities as CT, MRI, and ultrasound. CONCLUSION: Understanding the characteristics of squamous cell carcinoma of the head and neck, as imaged by FDG PET/CT, is crucial for determining treatment strategy, because it helps to avoid incorrect staging and also provides an accurate assessment of treatment response.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Multimodal , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/terapia , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
6.
J Urol ; 191(5): 1446-53, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24144687

RESUMO

PURPOSE: We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. MATERIALS AND METHODS: A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. RESULTS: In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. CONCLUSIONS: Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for prostate carcinoma recurrence. The former method detected significantly more prostatic and extraprostatic disease.


Assuntos
Anticorpos Monoclonais , Ácidos Carboxílicos , Carcinoma/diagnóstico , Ciclobutanos , Radioisótopos de Índio , Imagem Multimodal , Recidiva Local de Neoplasia/diagnóstico , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
Hell J Nucl Med ; 16(3): 169-74, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24137579

RESUMO

Our purpose was to evaluate quantitative mid-treatment fluorine-18-fluorodeoxyglucose (18F-FDG) PET/CT scans in predicting the quantitative result of the end of treatment 18F-FDG PET/CT scan. With approval of Emory's Institutional Review Board, data were extracted from 273 existing 18F-FDG PET/CT scans of 143 pediatric patients performed for evaluation of lymphoma. The inclusion criteria were the availability of an initial staging scan (D0) and a mid-treatment scan after 1 to 3 cycles of chemotherapy (D1) and a post-treatment scan (D2). Absolute and relative changed of D1 compared to D0 were measured and their values in predicting D3 values were determined. Analysis was performed on a lesion basis (N=78) in 18 patients with an average of 4.3 lesions per patients. Results showed that the predictive value depended on the value selected as significant for the predictors (D1 SUV and D1 %SUV), and on the limit between negative and positive selected for the predicted value D2 SUV. If the maximum SUV<2.0 in D2 was the limit for negative, the negative predictive value if D1<4 was 0.84%. If positive was defined as D2>3.0, the positive predictive value of D1>4 was 100%. In that way outcome was predictable with absolute certainty in as many as 71% of the lesions with a single limit for D1 and D2. In conclusion, in this limited retrospective study the positive predictive value of the mid-treatment scan, was high for the post-treatment result for patient and lesion response seen on D2.


Assuntos
Antineoplásicos/uso terapêutico , Fluordesoxiglucose F18 , Linfoma/diagnóstico , Linfoma/tratamento farmacológico , Imagem Multimodal/estatística & dados numéricos , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Criança , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Linfoma/epidemiologia , Masculino , Prevalência , Prognóstico , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
8.
World J Nucl Med ; 22(4): 316-320, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152102

RESUMO

Skeletal metastases due to prostate cancer (PCa) are more commonly osteoblastic than osteolytic. In the rarer cases of osteolytic skeletal metastasis of PCa, transition to osteoblastic phenotype occurs following treatment, which indicates successful healing. In this report, we present a case of spontaneous osteolytic to osteoblastic evolution of PCa skeletal metastasis without treatment in a patient with recurrence of PCa. Our patient is a 59-year-old male who had a robotic radical prostatectomy in July 2014 for a T2c adenocarcinoma of the prostate gland (Gleason score = 4 + 3). He had adjuvant pelvic radiotherapy in January 2015 due to prostate-specific antigen (PSA) persistence. PSA began to rise in October 2015. An 18 F-fluciclovine positron emission tomography/computed tomography (PET/CT) scan obtained in June 2017 at a PSA of 0.5 ng/mL was negative. Repeat 18 F-fluciclovine PET/CT of February 2020 at PSA of 3.72 ng/mL showed prostate bed recurrence and a nonavid osteolytic left inferior pubic ramus lesion. 18F radiohybrid prostate-specific membrane antigen ( 18 F-rhPSMA) PET/CT scan of August 2020 performed as part of an ongoing clinical trial confirmed local prostate bed recurrence with a low-grade radiotracer uptake in the osteolytic left inferior pubic ramus bone lesion. Without salvage therapy, 18 F-fluciclovine PET/CT of October 2020 and March 2022 shows progressive sclerosis in the left pubic ramus lesion. An osteolytic to osteoblastic transition of a bone lesion as shown in this patient calls for a rethink in our understanding of untreated PCa skeletal metastasis progression. This case provides novel insight into the understanding of the temporal evolution of skeletal metastasis and calls for further research.

9.
Clin Nucl Med ; 48(9): e455-e457, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37385218

RESUMO

ABSTRACT: 68 Ga-prostate-specific membrane antigen (PSMA) PET/CT is a valuable tool for staging and restaging of prostate cancer. Prostate-specific membrane antigen expression is not specific to prostate cancer, as it is expressed in normal tissues as well as in neoplastic and nonneoplastic processes. Awareness of the broad possibility of lesions with PSMA avidity is necessary to recognize normal variants and avoid potential pitfalls in image interpretation. We present a series of cases showing physiologic focal PSMA avidity in hepatic segment IVb. We correlate this uptake with aberrant hepatic vasculature. The awareness of this variant is important for accurate image interpretation to prevent additional invasive procedures, undue treatment escalation, and denial of curative treatment to patients.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Isótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Gálio , Neoplasias da Próstata/patologia , Ácido Edético , Fígado/metabolismo
10.
Nucl Med Commun ; 44(6): 427-433, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37038959

RESUMO

OBJECTIVE: iRENEX is a software module that incorporates scintigraphic and clinical data to interpret 99m Tc- mercaptoacetyltriglycine (MAG3) diuretic studies and provide reasons for their conclusions. Our objectives were to compare iRENEX interpretations with those of expert physicians, use iRENEX to evaluate resident performance and determine if iRENEX could improve the diagnostic accuracy of experienced residents. METHODS: Baseline and furosemide 99m Tc-MAG3 acquisitions of 50 patients with suspected obstruction (mean age ± SD, 58.7 ±â€…15.8 years, 60% female) were randomly selected from an archived database and independently interpreted by iRENEX, three expert readers and four nuclear medicine residents with one full year of residency. All raters had access to scintigraphic data and a text file containing clinical information and scored each kidney on a scale from +1.0 to -1.0. Scores ≥0.20 represented obstruction with higher scores indicating greater confidence. Scores +0.19 to -0.19 were indeterminate; scores ≤-0.20 indicated no obstruction. Several months later, residents reinterpreted the studies with access to iRENEX. Receiver operating characteristic (ROC) analysis and concordance correlation coefficient (CCC) quantified agreement. RESULTS: The CCC among experts was higher than that among residents, 0.84, versus 0.39, respectively, P  < 0.001. When residents reinterpreted the studies with iRENEX, their CCC improved from 0.39 to 0.73, P  < 0.001. ROC analysis showed significant improvement in the ability of residents to distinguish between obstructed and non-obstructed kidneys using iRENEX ( P  = 0.036). CONCLUSION: iRENEX interpretations were comparable to those of experts. iRENEX reduced interobserver variability among experienced residents and led to better agreement between resident and expert interpretations.


Assuntos
Diuréticos , Tecnécio Tc 99m Mertiatida , Humanos , Feminino , Masculino , Renografia por Radioisótopo , Cintilografia , Computadores , Compostos Radiofarmacêuticos
11.
Clin Nucl Med ; 48(4): e153-e159, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36754362

RESUMO

PURPOSE: We aimed to evaluate the impact of 18 F-fluciclovine PET/CT imaging on failure-free survival (FFS) post-salvage radiotherapy (SRT) for prostate cancer (PCa) recurrence. METHODS: Seventy-nine patients were recruited in a phase 2/3 clinical trial to undergo 18 F-fluciclovine PET/CT before SRT for PCa. Four patients with extrapelvic disease were excluded. All patients were followed up at regular intervals up to 48 months. Treatment failure was defined as a serum prostate-specific antigen level of ≥0.2 ng/mL above the nadir after SRT, confirmed with an additional measurement, requiring systemic treatment or clinical progression. Failure-free survival was computed and compared between patients grouped according to 18 F-fluciclovine PET/CT imaging findings. RESULTS: Eighty percent (60/75) of patients had a positive finding on 18 F-fluciclovine PET/CT, of which 56.7% (34/60) had prostate bed-only uptake, whereas 43.3% (26/60) had pelvic nodal ± bed uptake. Following SRT, disease failure was detected in 36% (27/75) of patients. There was a significant difference in FFS between patients who had a positive versus negative scan (62.3% vs 92.9% [ P < 0.001] at 36 months and 59.4% vs 92.9% [ P < 0.001] at 48 months). Similarly, there was a significant difference in FFS between patients with uptake in pelvic nodes ± bed versus prostate bed only at 36 months (49.8% vs 70.7%; P = 0.003) and at 48 months (49.8% vs 65.6%; P = 0.040). Failure-free survival was also significantly higher in patients with either negative PET/CT or prostate bed-only disease versus those with pelvic nodal ± prostate bed disease at 36 (78% vs 49.8%, P < 0.001) and 48 months (74.4% vs 49.8%, P < 0.001). CONCLUSIONS: Findings on pre-SRT 18 F-fluciclovine PET/CT imaging, even when acted upon to optimize the treatment decisions and treatment planning, are predictive of post-SRT FFS in men who experience PCa recurrence after radical prostatectomy. A negative 18 F-fluciclovine PET/CT is most predictive of a lower risk of failure, whereas the presence of pelvic nodal recurrence portends a higher risk of SRT failure.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/cirurgia , Ácidos Carboxílicos , Falha de Tratamento , Terapia de Salvação , Recidiva Local de Neoplasia , Antígeno Prostático Específico , Prostatectomia
12.
J Nucl Med ; 64(4): 586-591, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36328489

RESUMO

The EMPIRE-1 (Emory Molecular Prostate Imaging for Radiotherapy Enhancement 1) trial reported a survival advantage in recurrent prostate cancer salvage radiotherapy (SRT) guided by 18F-fluciclovine PET/CT versus conventional imaging. We performed a post hoc analysis of the EMPIRE-1 cohort stratified by protocol-specified criteria, comparing failure-free survival (FFS) between study arms. Methods: EMPIRE-1 randomized patients to SRT planning via either conventional imaging only (bone scanning plus abdominopelvic CT or MRI) (arm A) or conventional imaging plus 18F-fluciclovine PET/CT (arm B). Randomization was stratified by prostate-specific antigen (PSA) level (<2.0 vs. ≥ 2.0 ng/mL), adverse pathology, and androgen-deprivation therapy (ADT) intent. We subdivided patients in each arm using the randomization stratification criteria and compared FFS between patient subgroups across study arms. Results: Eighty-one and 76 patients received per-protocol SRT in study arms A and B, respectively. The median follow-up was 3.5 y (95% CI, 3.0-4.0). FFS was 63.0% and 51.2% at 36 and 48 mo, respectively, in arm A and 75.5% at both 36 and 48 mo in arm B. Among patients with a PSA of less than 2 ng/mL (mean, 0.42 ± 0.42 ng/mL), significantly higher FFS was seen in arm B than arm A at 36 mo (83.2% [95% CI, 70.0-91.0] vs. 66.5% [95% CI, 51.6-77.8], P < 0.001) and 48 mo (83.2% [95% CI, 70.0-91.0] vs. 56.2% [95% CI, 40.5-69.2], P < 0.001). No significant difference in FFS between study arms in patients with a PSA of at least 2 ng/mL was observed. Among patients with adverse pathology, significantly higher FFS was seen in arm B than arm A at 48 mo (68.9% [95% CI, 52.1-80.8] vs. 42.8% [95% CI, 26.2-58.3], P < 0.001) though not at the 36-mo follow-up. FFS was higher in patients without adverse pathology in arm B versus arm A (90.2% [95% CI, 65.9-97.5] vs. 73.1% [95% CI, 42.9-89.0], P = 0.006) at both 36 and 48 mo. Patients in whom ADT was intended in arm B had higher FFS than those in arm A, with the difference reaching statistical significance at 48 mo (65.2% [95% CI, 40.3-81.7] vs. 29.1 [95% CI, 6.5-57.2], P < 0.001). Patients without ADT intent in arm B had significantly higher FFS than patients in arm A at 36 mo (80.7% [95% CI, 64.9-90.0] vs. 68.0% [95% CI, 51.1-80.2]) and 48 mo (80.7% [95% CI, 64.9-90.0] vs. 58.6% [95% CI, 41.0-72.6]). Conclusion: The survival advantage due to the addition of 18F-fluciclovine PET/CT to SRT planning is maintained regardless of the presence of adverse pathology or ADT intent. Including 18F-fluciclovine PET/CT to SRT leads to survival benefits in patients with a PSA of less than 2 ng/mL but not in patients with a PSA of 2 ng/mL or higher.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Antagonistas de Androgênios , Recidiva Local de Neoplasia/patologia , Prostatectomia/métodos
13.
Eur J Nucl Med Mol Imaging ; 39(9): 1483-91, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22644714

RESUMO

PURPOSE: Decision support systems for imaging analysis and interpretation are rapidly being developed and will have an increasing impact on the practice of medicine. RENEX is a renal expert system to assist physicians evaluate suspected obstruction in patients undergoing mercaptoacetyltriglycine (MAG3) renography. RENEX uses quantitative parameters extracted from the dynamic renal scan data using QuantEM™II and heuristic rules in the form of a knowledge base gleaned from experts to determine if a kidney is obstructed; however, RENEX does not have access to and could not consider the clinical information available to diagnosticians interpreting these studies. We designed and implemented a methodology to incorporate clinical information into RENEX, implemented motion detection and evaluated this new comprehensive system (iRENEX) in a pilot group of 51 renal patients. METHODS: To reach a conclusion as to whether a kidney is obstructed, 56 new clinical rules were added to the previously reported 60 rules used to interpret quantitative MAG3 parameters. All the clinical rules were implemented after iRENEX reached a conclusion on obstruction based on the quantitative MAG3 parameters, and the evidence of obstruction was then modified by the new clinical rules. iRENEX consisted of a library to translate parameter values to certainty factors, a knowledge base with 116 heuristic interpretation rules, a forward chaining inference engine to determine obstruction and a justification engine. A clinical database was developed containing patient histories and imaging report data obtained from the hospital information system associated with the pertinent MAG3 studies. The system was fine-tuned and tested using a pilot group of 51 patients (21 men, mean age 58.2 ± 17.1 years, 100 kidneys) deemed by an expert panel to have 61 unobstructed and 39 obstructed kidneys. RESULTS: iRENEX, using only quantitative MAG3 data agreed with the expert panel in 87 % (34/39) of obstructed and 90 % (55/61) of unobstructed kidneys. iRENEX, using both quantitative and clinical data agreed with the expert panel in 95 % (37/39) of obstructed and 92 % (56/61) of unobstructed kidneys. The clinical information significantly (p < 0.001) increased iRENEX certainty in detecting obstruction over using the quantitative data alone. CONCLUSION: Our renal expert system for detecting renal obstruction has been substantially expanded to incorporate the clinical information available to physicians as well as advanced quality control features and was shown to interpret renal studies in a pilot group at a standardized expert level. These encouraging results warrant a prospective study in a large population of patients with and without renal obstruction to establish the diagnostic performance of iRENEX.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Interpretação de Imagem Assistida por Computador/métodos , Nefropatias/diagnóstico por imagem , Tecnécio Tc 99m Mertiatida , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Renografia por Radioisótopo , Incerteza
14.
J Nucl Med Technol ; 2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36195443

RESUMO

A sentinel event is any unexpected event that results in death or serious physical or psychological injury to a patient unrelated to a patient's illness. Establishing and determining cause-and-effect relationships is key to preventing future sentinel/near-miss events. However, it can be challenging to establish a cause-and-effect relationship when a process involves multiple steps or people. Root cause analysis (RCA) is a technique that can pinpoint the causes of sentinel events for medical procedures involving numerous steps and people. This article provides a rationale for RCA and the basic steps in a nonmedical RCA investigation. The article then describes a more detailed, nine-step RCA approach for investigating sentinel events and illustrates the technique with a nuclear medicine example.

15.
Radiology ; 259(3): 852-61, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21493787

RESUMO

PURPOSE: To compare the diagnostic performance of the synthetic amino acid analog radiotracer anti-1-amino-3-fluorine 18-fluorocyclobutane-1-carboxylic acid (anti-3-(18)F-FACBC) with that of indium 111 ((111)In)-capromab pendetide in the detection of recurrent prostate carcinoma. MATERIALS AND METHODS: This prospective study was approved by the institutional review board and complied with HIPAA guidelines. Written informed consent was obtained. Fifty patients (mean age, 68.3 years ± 8.1 [standard deviation]; age range, 50-90 years) were included in the study on the basis of the following criteria: (a) Recurrence of prostate carcinoma was suspected after definitive therapy for localized disease, (b) bone scans were negative, and (c) anti-3-(18)F-FACBC positron emission tomography (PET)/computed tomography (CT) and (111)In-capromab pendetide single photon emission computed tomography (SPECT)/CT were performed within 6 weeks of each other. Studies were evaluated by two experienced interpreters for abnormal uptake suspicious for recurrent disease in the prostate bed and extraprostatic locations. The reference standard was a combination of tissue correlation, imaging, laboratory, and clinical data. Diagnostic performance measures were calculated and tests of the statistical significance of differences determined by using the McNemar χ(2) test as well as approximate tests based on the difference between two proportions. RESULTS: For disease detection in the prostate bed, anti-3-(18)F-FACBC had a sensitivity of 89% (32 of 36 patients; 95% confidence interval [CI]: 74%, 97%), specificity of 67% (eight of 12 patients; 95% CI: 35%, 90%), and accuracy of 83% (40 of 48 patients; 95% CI: 70%, 93%). (111)In-capromab pendetide had a sensitivity of 69% (25 of 36 patients; 95% CI: 52%, 84%), specificity of 58% (seven of 12 patients; 95% CI: 28%, 85%), and accuracy of 67% (32 of 48 patients; 95% CI: 52%, 80%). In the detection of extraprostatic recurrence, anti-3-(18)F-FACBC had a sensitivity of 100% (10 of 10 patients; 95% CI: 69%, 100%), specificity of 100% (seven of seven patients; 95% CI: 59%, 100%), and accuracy of 100% (17 of 17 patients; 95% CI: 80%, 100%). (111)In-capromab pendetide had a sensitivity of 10% (one of 10 patients; 95% CI: 0%, 45%), specificity of 100% (seven of seven patients; 95% CI: 59%, 100%), and accuracy of 47% (eight of 17 patients; 95% CI: 23%, 72%). CONCLUSION: anti-3-(18)F-FACBC PET/CT was more sensitive than (111)In-capromab pendetide SPECT/CT in the detection of recurrent prostate carcinoma and is highly accurate in the differentiation of prostatic from extraprostatic disease. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11102023/-/DC1.


Assuntos
Anticorpos Monoclonais , Ácidos Carboxílicos , Ciclobutanos , Radioisótopos de Índio , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Humanos , Indicadores e Reagentes , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
16.
EJNMMI Res ; 11(1): 43, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33934268

RESUMO

PURPOSE: 99mTc-tricarbonyl-nitrilotriacetic acid, [99mTc]Tc(CO)3(NTA), is a new 99mTc-renal radiopharmaceutical with a clearance equal to that of 131I-ortho-iodohippuran, [131I]I-OIH. Our purpose was to compare the performance of [99mTc]Tc(CO)3(NTA) and [99mTc]Tc-MAG3 in patients with suspected obstruction. METHODS: [99mTc]Tc(CO)3(NTA) was prepared with commercially available NTA ligand and CRS Isolink kit, and isolated by HPLC. Eighteen adult patients referred for diuretic renography received an intravenous injection of approximately 40 mg of furosemide 15 min prior to either [99mTc]Tc(CO)3(NTA) or [99mTc]Tc-MAG3 (mean activity of 47 ± 4.4 MBq). Data were acquired for 24 min followed by an anterior image of the liver and gall bladder and a measure of voided volume. Patients received a second furosemide injection equal to one third of the original dose followed fifteen minutes later by administration of the alternate tracer, mean activity of 320 ± 34 MBq. Clearances were measured using a camera-based technique. RESULTS: The clearance of NTA was greater than that of MAG3, 331 ± 146 versus 271 ± 105 mL/min/1.73 m2, respectively, p < 0.0001. The kidney to background ratio for NTA was greater than that of MAG3 for both left and right kidneys, p < 0.001; the 20 min/maximum count ratio was significantly less, p < 0.0001. There was no significant difference in the voiding volumes following NTA and MAG3 administration, 598 ± 237 mL versus 498 ± 170 mL, respectively, p = 0.07. Gall bladder activity was not observed with NTA but was present in 6/17 MAG3 studies. Images and renogram curves were comparable except for two patients where the NTA study excluded obstruction but the MAG3 study suggested an indeterminate or obstructed kidney. CONCLUSIONS: Unlike MAG3, NTA is not eliminated via the hepatobiliary track. Moreover, NTA has a higher kidney to background ratio and more rapid clearance than MAG3. These advantages should allow more robust camera-based clearance measurements and may lead to better discrimination between obstructed and non-obstructed kidneys.

17.
J Nucl Med Technol ; 49(4): 350-353, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34862264

RESUMO

Establishing a cause-and-effect relationship for an adverse event is one of the key steps in preventing them and involves multiple people, resources, and steps, thus requiring a root cause analysis. Here, we describe a root cause analysis performed in the nuclear medicine department for an event involving Na131I contamination. Oral administration of Na131I in a capsule minimizes the risk of contamination and spills. However, the patient must be able to swallow a capsule. Na131I in capsule form is currently in widespread use for treatment of hyperthyroidism and thyroid cancer. Na131I in liquid form is rarely available immediately on demand and must be ordered at least 24-48 h in advance of the planned administration. The events leading to the incident, immediate remedial steps taken, and subsequent root cause analysis are described. The corrective actions taken after the root cause analysis, as well as the subsequent effectiveness of these actions, are mentioned. There may be one or multiple causes for an adverse event. It is important to identify the root cause. Corrective actions derived from the root cause can help prevent similar adverse events in the future. Therapeutic procedures in nuclear medicine involve unsealed radioactive sources, further adding a separate layer of immediate steps and reporting to the root cause analysis itself.


Assuntos
Hipertireoidismo , Análise de Causa Fundamental , Contaminação de Medicamentos , Humanos , Radioisótopos do Iodo/efeitos adversos
18.
J Nucl Med Technol ; 49(4): 330-333, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34330806

RESUMO

We aimed to show that the acquisition time of a conventional bone scan could be reduced by half without losing the diagnostic value of the scan. Methods: Fifty adult patients (37 male and 13 female; mean age, 62.5 y; SD, 8.7 y) were enrolled. The patients were injected with 925-1,110 MBq (25-30 mCi) of 99mTc-methylene diphosphonate intravenously. The standard-protocol whole-body planar images were acquired first (scan speed, 10 cm/min; acquisition time, ∼20 min) and were followed immediately by the half-time protocol whole-body planar images (scan speed, 20 cm/min; acquisition time, ∼10 min). Both sets of images were interpreted by 2 nuclear medicine physicians. Each reviewer, when reviewing the standard-protocol images, was self-masked to the result he or she had obtained when reviewing the half-time images, and vice versa. This self-masking was accomplished by allowing a minimum of 2 wk to elapse between the 2 interpretations. We used the κ-coefficient to compare agreement between the standard-protocol results and the half-time results. Results: There was no difference in clinically significant diagnostic information between the half-time and standard protocols. The diagnostic quality of half-time and standard-protocol images did not significantly differ (0.86 < κ < 1.0). Conclusion: Our data suggest that if we reduce the 99mTc-methylene diphosphonate dose by half and keep the acquisition time at its standard value, we gain the benefit of reduced dose without loss of diagnostic value.


Assuntos
Compostos Radiofarmacêuticos , Medronato de Tecnécio Tc 99m , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Tomografia Computadorizada por Raios X
19.
Clin Nucl Med ; 46(5): e282-e285, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33208627

RESUMO

ABSTRACT: 18F-Fluciclovine is an amino acid-based radiopharmaceutical used primarily for PET imaging of patients with biochemical recurrence of prostate cancer. We report a case of a 66-year-old man with recently diagnosed metastatic castrate-resistant prostate cancer and a left supraclavicular lymph node with incidental radiotracer uptake on 18F-fluciclovine PET/CT. Left neck core needle biopsy confirmed high-grade, poorly differentiated carcinoma with neuroendocrine features positive for synaptophysin and chromogranin, and negative for prostate markers.


Assuntos
Ácidos Carboxílicos/metabolismo , Ciclobutanos/metabolismo , Tumores Neuroendócrinos/metabolismo , Tumores Neuroendócrinos/secundário , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias de Próstata Resistentes à Castração/patologia , Idoso , Transporte Biológico , Humanos , Masculino , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia
20.
J Nucl Med ; 62(8): 1089-1096, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33517323

RESUMO

Imaging with novel PET radiotracers has significantly influenced radiotherapy decision making and radiation planning in patients with recurrent prostate cancer (PCa). The purpose of this analysis was to report the final results for management decision changes based on 18F-fluciclovine PET/CT findings and determine whether the decision change trend remained after completion of accrual. Methods: Patients with detectable prostate-specific antigen (PSA) after prostatectomy were randomized to undergo either conventional imaging (CI) only (arm A) or CI plus 18F-fluciclovine PET/CT (arm B) before radiotherapy. In arm B, positivity rates on CI and 18F-fluciclovine PET/CT for detection of recurrent PCa were determined. Final decisions on whether to offer radiotherapy and whether to include only the prostate bed or also the pelvis in the radiotherapy field were based on 18F-fluciclovine PET/CT findings. Radiotherapy decisions before and after 18F-fluciclovine PET/CT were compared. The statistical significance of decision changes was determined using the Clopper-Pearson (exact) binomial method. Prognostic factors were compared between patients with and without decision changes. Results: All 165 patients enrolled in the study had standard-of-care CI and were initially planned to receive radiotherapy. Sixty-three of 79 (79.7%) patients (median PSA, 0.33 ng/mL) who underwent 18F-fluciclovine PET/CT (arm B) had positive findings. 18F-Fluciclovine PET/CT had a significantly higher positivity rate than CI did for the whole body (79.7% vs. 13.9%; P < 0.001), prostate bed (69.6% vs. 5.1%; P < 0.001), and pelvic lymph nodes (38.0% vs. 10.1%; P < 0.001). Twenty-eight of 79 (35.4%) patients had the overall radiotherapy decision changed after 18F-fluciclovine PET/CT; in 4 of 79 (5.1%), the decision to use radiotherapy was withdrawn because of extrapelvic disease detected on 18F-fluciclovine PET/CT. In 24 of 75 (32.0%) patients with a final decision to undergo radiotherapy, the radiotherapy field was changed. Changes in overall radiotherapy decisions and radiotherapy fields were statistically significant (P < 0.001). Overall, the mean PSA at PET was significantly different between patients with and without radiotherapy decision changes (P = 0.033). Conclusion:18F-Fluciclovine PET/CT significantly altered salvage radiotherapy decisions in patients with recurrent PCa after prostatectomy. Further analysis to determine the impact of 18F-fluciclovine PET/CT guidance on clinical outcomes after radiotherapy is in progress.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Idoso , Ácidos Carboxílicos , Ciclobutanos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa