Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386967

RESUMO

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Obesidade , Ferro
2.
J Appl Clin Med Phys ; 25(7): e14383, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38801204

RESUMO

OBJECTIVE: To assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems. METHOD: A phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50  versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported. RESULTS: An experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45  and 0.33 mg/mL for the first and second-generation DLCT, respectively). CONCLUSION: The implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Espalhamento de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
3.
J Comput Assist Tomogr ; 45(1): 24-28, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32168080

RESUMO

OBJECTIVE: The aim of this study was to investigate if Hounsfield unit (HU) values from virtual noncontrast (VNC) images derived from portal venous phase spectral-detector computed tomography can help to differentiate adrenal adenomas and metastases. METHODS: Spectral-detector computed tomography datasets of 33 patients with presence of adrenal lesions and standard of reference for lesion origin by follow-up/prior examinations or dedicated magnetic resonance imaging were included. Conventional and VNC images were reconstructed from the same scan. Region of interest-based image analysis was performed in adrenal lesions and contralateral healthy adrenal tissue. RESULTS: The 33 lesions consisted of 23 adenomas and 10 metastases. Hounsfield unit values of all lesions in VNC images were significantly lower compared with conventional images (18.2 ± 12.6 HU vs 59.6 ± 21.7 HU, P < 0.001). Hounsfield unit values in adenomas were significantly lower in VNC images (11.3 ± 6.5 HU vs 34.1 ± 9.1 HU, P < 0.001). CONCLUSIONS: Virtual noncontrast HU values differed significantly between adrenal adenomas and metastases and can therefore be used for improved characterization of incidental adrenal lesions and definition of adrenal adenomas.


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/secundário , Glândulas Suprarrenais/patologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adenoma/patologia , Neoplasias das Glândulas Suprarrenais/patologia , Glândulas Suprarrenais/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Interface Usuário-Computador
4.
Radiographics ; 37(7): 1955-1974, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29131773

RESUMO

Advances in scanner technology enabling shorter scan times, improvements in spatial and temporal resolution, and more dose-efficient data reconstruction coupled with rapidly growing evidence from clinical trials have established computed tomography (CT) as an important imaging modality in the evaluation of cardiovascular disorders. Multienergy (or spectral or dual-energy) CT is a relatively recent advance in which attenuation data from different energies are used to characterize materials beyond what is possible at conventional CT. Current technologies for multienergy CT are either source based (ie, dual source, rapid kilovoltage switching, dual spin, and split beam) or detector based (ie, dual layer and photon counting), and material-based decomposition occurs in either image or projection space. In addition to conventional diagnostic images, multienergy CT provides image sets such as iodine maps, virtual nonenhanced, effective atomic number, and virtual monoenergy (VM) images as well as data at the elemental level (CT fingerprinting), which can complement and in some areas overcome the limitations posed by conventional CT methods. In myocardial perfusion imaging, iodine maps improve the sensitivity of perfusion defects, and VM images improve the specificity by decreasing artifacts. Iodine maps are also useful in improving the performance of CT in delayed-enhancement imaging. In pulmonary perfusion imaging, iodine maps enhance the sensitivity of detection of both acute and chronic pulmonary emboli. Low-energy (as measured in kiloelectron volts) VM images allow enhancement of vascular contrast, which can either be used to lower contrast dose or salvage a suboptimal contrast-enhanced study. High-energy VM images can be used to decrease or eliminate artifacts such as beam-hardening and metallic artifacts. Virtual nonenhanced images have similar attenuation as true nonenhanced images and help in reducing radiation dose by eliminating the need for the latter in multiphasic vascular studies. Other potential applications of multienergy CT include calcium scoring from virtual nonenhanced images created from coronary CT angiograms and myocardial iron quantification. Online supplemental material is available for this article. ©RSNA, 2017.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador
5.
Radiographics ; 36(7): 2064-2083, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27768543

RESUMO

Computed tomography is vulnerable to a wide variety of artifacts, including patient- and technique-specific artifacts, some of which are unique to imaging of the heart. Motion is the most common source of artifacts and can be caused by patient, cardiac, or respiratory motion. Cardiac motion artifacts can be reduced by decreasing the heart rate and variability and the duration of data acquisition; adjusting the placement of the data window within a cardiac cycle; performing single-heartbeat scanning; and using multisegment reconstruction, motion-correction algorithms, and electrocardiographic editing. Respiratory motion artifacts can be minimized with proper breath holding and shortened scan duration. Partial volume averaging is caused by the averaging of attenuation values from all tissue contained within a voxel and can be reduced by improving the spatial resolution, using a higher x-ray energy, or displaying images with a wider window width. Beam-hardening artifacts are caused by the polyenergetic nature of the x-ray beam and can be reduced by using x-ray filtration, applying higher-energy x-rays, altering patient position, modifying contrast material protocols, and applying certain reconstruction algorithms. Metal artifacts are complex and have multiple causes, including x-ray scatter, underpenetration, motion, and attenuation values that exceed the typical dynamic range of Hounsfield units. Quantum mottle or noise is caused by insufficient penetration of tissue and can be improved by increasing the tube current or peak tube potential, reconstructing thicker sections, increasing the rotation time, using appropriate patient positioning, and applying iterative reconstruction algorithms. ©RSNA, 2016.


Assuntos
Artefatos , Técnicas de Imagem Cardíaca/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Erros de Diagnóstico/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Medicina Baseada em Evidências , Humanos , Movimento (Física) , Próteses e Implantes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
AJR Am J Roentgenol ; 203(6): 1181-91, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25415695

RESUMO

OBJECTIVE: The purpose of this study was to investigate and validate adaptation of a cardiovascular CT angiography contrast injection protocol for lower tube potential. MATERIALS AND METHODS: Eighty-three patients evaluated for thoracic aortic disease with a 256-MDCT scanner were imaged at 120 kV (group 1) or 100 kV (group 2) with the same contrast protocol (90 mL iopromide 370 mg I/mL at 3.5 mL/s). A pharmacokinetic model was validated and used to simulate aortic attenuation in group 2 patients with 20%, 33%, and 44% reduction in contrast volume. A 44% volume reduction was applied to 50 additional patients who underwent imaging at 100 kV (group 3). Patient characteristics, scanning and radiation parameters, and objective and subjective image indexes were compared among groups. RESULTS: Group 2 patients had higher mean aortic blood attenuation (399±61 HU) than group 1 patients (281±48 HU) (p<0.001) but similar image noise. Group 3 and group 1 patients had similar mean aortic attenuation and noise. Subjective assessment of image quality indicated that group 3 and group 1 had comparable percentages of images with good or excellent diagnostic confidence scores (reader 1, 98% vs 96%; reader 2, 96% vs 96%). CONCLUSION: Lower tube potential (100 kV) for cardiothoracic CT could be accompanied by a 44% reduction in contrast volume with satisfactory aortic blood-pool attenuation in most patients. More personalized adaptation of the contrast protocol that takes into account patient characteristics and tube potential is necessary to ensure sufficient contrast enhancement for all patients.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Iohexol/análogos & derivados , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Doenças da Aorta/metabolismo , Simulação por Computador , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Iohexol/administração & dosagem , Iohexol/farmacocinética , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Artigo em Inglês | MEDLINE | ID: mdl-38836183

RESUMO

Deep learning CT reconstruction (DLR) has become increasingly popular as a method for improving image quality and reducing radiation exposure. Due to their nonlinear nature, these algorithms result in resolution and noise performance which are object-dependent. Therefore, traditional CT phantoms, which lack realistic tissue morphology, have become inadequate for assessing clinical imaging performance. We propose to utilize 3D-printed PixelPrint phantoms, which exhibit lifelike attenuation profiles, textures, and structures, as a better tool for evaluating DLR performance. In this study, we evaluate a DLR algorithm (Precise Image (PI), Philips Healthcare) using a custom PixelPrint lung phantom and perform head-to-head comparisons between DLR, iterative reconstruction, and filtered back projection (FBP) with scans acquired at a broad range of radiation exposures (CTDIvol: 0.5, 1, 2, 4, 6, 9, 12, 15, 19, and 20 mGy). We compared the performance of each resultant image using noise, peak signal to noise ratio (PSNR), structural similarity index (SSIM), feature-based similarity index (FSIM), information theoretic-based statistic similarity measure (ISSM) and universal image quality index (UIQ). Iterative reconstruction at 9 mGy matches the image quality of FBP at 12 mGy (diagnostic reference level) for all metrics, demonstrating a dose reduction capability of 25%. Meanwhile, DLR matches the image quality of diagnostic reference level FBP images at doses between 4 - 9 mGy, demonstrating dose reduction capabilities between 25% and 67%. This study shows that DLR allows for reduced radiation dose compared to both FBP and iterative reconstruction without compromising image quality. Furthermore, PixelPrint phantoms offer more realistic testing conditions compared to traditional phantoms in the evaluation of novel CT technologies. This, in turn, promotes the translation of new technologies, such as DLR, into clinical practice.

8.
Phys Med Biol ; 69(11)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38604190

RESUMO

Objective. Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels.Method. The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different size extension rings to mimic a small- and medium-sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error, structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image.Results.DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25%-83% in the small phantom and by 50%-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR.Conclusion. DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose, which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Razão Sinal-Ruído , Doses de Radiação , Algoritmos
9.
J Cardiovasc Comput Tomogr ; 18(1): 50-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38314547

RESUMO

BACKGROUND: Computed tomography aortic valve calcium (AVC) score has accepted value for diagnosing and predicting outcomes in aortic stenosis (AS). Multi-energy CT (MECT) allows virtual non-contrast (VNC) reconstructions from contrast scans. We aim to compare the VNC-AVC score to the true non-contrast (TNC)-AVC score for assessing AS severity. METHODS: We prospectively included patients undergoing a MECT for transcatheter aortic valve replacement (TAVR) planning. TNC-AVC was acquired before contrast, and VNC-AVC was derived from a retrospectively gated contrast-enhanced scan. The Agatston scoring method was used for quantification, and linear regression analysis to derive adjusted-VNC values. RESULTS: Among 109 patients (55% female) included, 43% had concordant severe and 14% concordant moderate AS. TNC scan median dose-length product was 116 â€‹mGy∗cm. The median TNC-AVC was 2,107 AU (1,093-3,372), while VNC-AVC was 1,835 AU (1293-2,972) after applying the coefficient (1.46) and constant (743) terms. A strong correlation was demonstrated between methods (r â€‹= â€‹0.93; p â€‹< â€‹0.001). Using accepted thresholds (>1,300 AU for women and >2,000 AU for men), 65% (n â€‹= â€‹71) of patients had severe AS by TNC-AVC and 67% (n â€‹= â€‹73) by adjusted-VNC-AVC. After estimating thresholds for adjusted-VNC (>1,564 AU for women and >2,375 AU for men), 56% (n â€‹= â€‹61) had severe AS, demonstrating substantial agreement with TNC-AVC (κ â€‹= â€‹0.77). CONCLUSIONS: MECT-derived VNC-AVC showed a strong correlation with TNC-AVC. After adjustment, VNC-AVC demonstrated substantial agreement with TNC-AVC, potentially eliminating the requirement for an additional scan and enabling reductions in both radiation exposure and acquisition time.


Assuntos
Estenose da Valva Aórtica , Tomografia Computadorizada por Raios X , Masculino , Humanos , Feminino , Estudos Retrospectivos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Cálcio
10.
AJR Am J Roentgenol ; 201(5): 971-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147466

RESUMO

OBJECTIVE: The purpose of this study was to compare high-pitch ECG-synchronized pulmonary CT angiography (CTA) with standard pulmonary CTA with regard to radiation dose and image quality in patients with suspected pulmonary embolism. SUBJECTS AND METHODS: This prospective study was approved by the institutional review board, and participants provided informed consent. Patients with suspected pulmonary embolism (60% women; mean age, 57 ± 14 years) were randomized to undergo high-pitch ECG-synchronized pulmonary CTA (n = 26) or standard pulmonary CTA (n = 21). Two independent readers assessed subjective image quality of pulmonary arteries, cardiovascular structures, and pulmonary parenchyma. Signal intensity (SI) was measured in one segmental and three central pulmonary arteries. RESULTS: High-pitch ECG-synchronized pulmonary CTA showed higher SI (p < 0.001) for pulmonary arteries. Image quality scores indicated improvement in assessment of cardio-vascular structures (p < 0.001), minimization of motion of central (p < 0.001) pulmonary arteries, and an increase in pulmonary arterial enhancement (p = 0.01) with high-pitch ECG-synchronized pulmonary CTA. Image quality scores for lung assessment were higher for standard pulmonary CTA (p < 0.001). The amount of contrast agent administered was similar between techniques (p = 0.86). Radiation dose was lower for high-pitch ECG-synchronized pulmonary CTA (p < 0.001). CONCLUSION: High-pitch ECG-synchronized pulmonary CTA provides higher pulmonary arterial SI, decreased motion of central pulmonary arteries, and improved assessment of cardiovascular structures with similar contrast dose and lower radiation compared with standard pulmonary CTA.


Assuntos
Angiografia/métodos , Técnicas de Imagem de Sincronização Cardíaca , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
11.
Quant Imaging Med Surg ; 13(2): 924-934, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36819257

RESUMO

Background: To determine the spectral accuracy in detector-based dual-energy CT (DECT) at 100 kVp and wide (8 cm) collimation width for dose levels and object sizes relevant to pediatric imaging. Methods: A spectral CT phantom containing tissue-equivalent materials and iodine inserts of varying concentrations was scanned on the latest generation detector-based DECT system. Two 3D-printed extension rings were used to mimic varying pediatric patient sizes. Scans were performed at 100 and 120 kVp, 4 and 8 cm collimation widths, and progressively reduced radiation dose levels, down to 0.9 mGy CTDIvol. Virtual mono-energetic, iodine density, effective atomic number, and electron density results were quantified and compared to their expected values for all acquisition settings and phantom sizes. Results: DECT scans at 100 kVp provided highly accurate spectral results; however, a size dependence was observed for iodine quantification. For the medium phantom configuration (15 cm diameter), measurement errors in iodine density, effective atomic number, and electron density (ED) were below 0.3 mg/mL, 0.2 and 1.8 %EDwater, respectively. The average accuracy was slightly different from scans at 120 kVp; however, not statistically significant for all configurations. Collimation width had no substantial impact. Spectral results were accurate and reliable for radiation exposures down to 0.9 mGy CTDIvol. Conclusions: Detector-based DECT at 100 kVp can provide on-demand or retrospective spectral information with high accuracy even at extremely low doses, thereby making it an attractive solution for pediatric imaging.

12.
medRxiv ; 2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38106064

RESUMO

Objective: Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels. Approach: The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different sized extension rings to mimic a small and medium sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error (RMSE), structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image. Main Results: DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25-83% in the small phantom and by 50-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR with a non-anatomical physics phantom. Significance: DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.

13.
AJR Am J Roentgenol ; 198(4): 931-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22451563

RESUMO

OBJECTIVE: We sought to compare image quality, contrast enhancement, and radiation dose in patients undergoing ECG-triggered high-pitch helical CT or non-ECG-synchronized helical CT of the thoracoabdominal aorta. MATERIALS AND METHODS: We retrospectively assessed data from 101 consecutive patients (81 men, 20 women; mean age, 71 ± 11 [SD] years) undergoing clinically indicated CT angiography (CTA) of the thoracoabdominal aorta on a dual-source scanner using either the ECG-triggered high-pitch helical mode (group 1, n = 52) or non-ECG-synchronized standard-pitch helical mode (group 2, n = 49) during the arterial phase. Two independent readers assessed image quality, noise, and contrast enhancement throughout the thoracoabdominal aorta. Scanner-reported dose-length product values were used to estimate effective dose values. RESULTS: Image quality at the root-proximal ascending level was higher in group 1 (mean ± SD, 2.81 ± 0.40) than in group 2 (1.22 ± 0.47; p < 0.0001), with similar quality for both groups noted at other levels. Group 1 scans displayed higher image noise at all levels. The groups received a similar volume of contrast material (p = 0.77), and similar percentages of cases with acceptable contrast enhancement (> 250 HU) were noted in the two groups. The estimated radiation burden was significantly lower in group 1 (mean ± SD, 5.4 ± 1.8 mSv) than in group 2 (14.4 ± 5.1 mSv; p < 0.0001). CONCLUSION: Imaging of the thoracoabdominal aorta with ECG-triggered high-pitch CTA provides higher quality images of the aortic root and ascending aorta with sufficient contrast enhancement and decreased estimated radiation dose compared with non-ECG-synchronized standard-pitch helical CT.


Assuntos
Angiografia/métodos , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Tomografia Computadorizada Espiral/métodos , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Doses de Radiação , Estudos Retrospectivos
14.
Curr Cardiol Rep ; 14(1): 17-23, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22057687

RESUMO

Since its introduction in the 1970s, diagnostic computed tomography (CT) imaging has grown rapidly and developed into a standard diagnostic test for a wide variety of cardiovascular conditions. Although this has undoubtedly led to improved medical care, it has also been associated with a significant increase in population-based radiation exposure and the potential downstream increase in cancer is a justified concern. For cardiovascular CT, new CT scanner technologies were initially directed toward maximizing image quality rather than minimizing radiation exposure. Only more recently have technologic advances yielded dose-saving protocols for cardiovascular applications, with impressive reduction of radiation exposure. The achievable limits of population-based exposure are dependent on responsible, evidence-based use of CT for cardiovascular imaging as well as exploitation of available and emerging dose-saving strategies.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Neoplasias Induzidas por Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Fatores Etários , Índice de Massa Corporal , Angiografia Coronária/efeitos adversos , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Doses de Radiação , Fatores de Risco
15.
Eur Heart J ; 31(22): 2727-40, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20797981

RESUMO

The rapid expansion of less invasive surgical and transcatheter cardiovascular procedures for a wide range of cardiovascular conditions, including coronary, valvular, structural cardiac, and aortic disease has been paralleled by novel three-dimensional (3-D) approaches to imaging. Three-dimensional imaging allows acquisition of volumetric data sets and subsequent off-line reconstructions along unlimited 2-D planes and 3-D volumes. Pre-procedural 3-D imaging provides detailed understanding of the operative field for surgical/interventional planning. Integration of imaging modalities during the procedure allows real-time guidance. Because computed tomography routinely acquires 3-D data sets, it has been one of the early imaging modalities applied in the context of surgical and interventional planning. This review describes the continuum of applications from pre-operative planning to procedural integration, based on the emerging experience with computed tomography and rotational angiography, respectively. At the same time, the potential adverse effects of imaging with X-ray-based tomographic or angiographic modalities are discussed. It is emphasized that the role of imaging guidance in this context remains unclear and will need to be evaluated in clinical trials. This is in particular true, because data showing improved outcome or even non-inferiority for most of the emerging transcatheter procedures are still lacking.


Assuntos
Ablação por Cateter/métodos , Cardiopatias/cirurgia , Tomografia Computadorizada por Raios X/métodos , Eletrocardiografia , Humanos , Imageamento Tridimensional , Cuidados Intraoperatórios/métodos , Planejamento de Assistência ao Paciente , Cuidados Pré-Operatórios/métodos , Radiografia Intervencionista/métodos , Stents
16.
Plast Reconstr Surg ; 147(1): 49-55, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33002983

RESUMO

BACKGROUND: Neck fat distribution plays an important role in aging, yet how fat distribution changes with age is largely unknown. This study used volumetric computed tomography in live patients to characterize neck fat volume and distribution in young and elderly women. METHODS: A retrospective analysis was conducted of head and neck computed tomographic angiographs of 20 young (aged 20 to 35 years) and 20 old (aged 65 to 89 years) women. Fat volume in the supraplatysmal and subplatysmal planes was quantified. Distribution of fat volume was assessed by dividing each supraplatysmal and subplatysmal compartment into upper, middle, and lower thirds. RESULTS: Total supraplatysmal fat volume was greater than subplatysmal in all patients. Young patients had more total supraplatysmal fat than old patients (p < 0.0001). No difference was found between age groups in subplatysmal fat (p > 0.05). No difference was found between upper/middle/lower third supraplatysmal fat volumes in young patients. When comparing supraplatysmal thirds within the elderly population, the middle third fat volume (28.58 ± 20.01 cm3) was greater than both upper (18.93 ± 10.35 cm3) and lower thirds (15.46 ± 11.57 cm3) (p < 0.01). CONCLUSIONS: This study suggests that total supraplatysmal fat volume decreases with age. Older patients had more fat volume in the upper and middle thirds compared with the lower third of the supraplatysmal fat compartment, whereas young patients had more evenly distributed fat. These results suggest that fat deposition and redistribution in the neck occur with age and may be a contributing factor to the obtuse cervicomandibular angle of the elderly.


Assuntos
Adiposidade/fisiologia , Envelhecimento/fisiologia , Gordura Subcutânea/diagnóstico por imagem , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Pescoço , Estudos Retrospectivos , Gordura Subcutânea/irrigação sanguínea , Gordura Subcutânea/fisiologia , Adulto Jovem
17.
AJR Am J Roentgenol ; 195(2): 486-93, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20651209

RESUMO

OBJECTIVE: The purpose of this study was to investigate replacing unenhanced and arterial single-energy CT acquisitions after endovascular aneurysm repair with one dual-energy CT arterial acquisition. SUBJECTS AND METHODS: Thirty patients underwent arterial dual-energy CT (80 and 140 kVp) and venous single-energy CT (120 kVp) after endovascular aneurysm repair, and the radiation doses were compared with those of a standard triple-phase protocol. Both virtual unenhanced and arterial images were generated with dual-energy CT. Images were reviewed clinically for detection of endoleaks and evaluation of stent and calcium appearance. The aortic luminal attenuation on virtual unenhanced CT images was compared with that on previously acquired true unenhanced images. Virtual unenhanced, arterial, and venous images were compared for thrombus attenuation. Single-energy CT and dual-energy CT images were compared for noise. RESULTS: Replacement of two (unenhanced, arterial) of three single-energy CT acquisitions with one dual-energy CT acquisition resulted in 31% radiation dose savings. All images were clinically interpretable. Thoracic (32 +/- 2 vs 35 +/- 4 HU) and abdominal (30 +/- 3 vs 35 +/- 5 HU) aortic attenuation was similar on virtual unenhanced and true unenhanced images. Thrombus attenuation was similar on virtual unenhanced (32 +/- 6 HU), arterial phase (33 +/- 7 HU), and venous phase (34 +/- 6 HU) images. Decreased stent and calcium attenuation was observed at some locations on virtual unenhanced images. Noise in the thoracic (10 +/- 1 HU) and abdominal (12 +/- 2 HU) aorta was lower on virtual unenhanced images than on true unenhanced images (13 +/- 4 HU, 19 +/- 5 HU). Noise was comparable for dual-energy and single-energy CT (thorax, 16 +/- 2 vs 13 +/- 2 HU; abdomen, 21 +/- 3 vs 23 +/- 5 HU). CONCLUSION: Virtual unenhanced and arterial phase images derived from dual-energy CT can replace true unenhanced and arterial phase single-energy CT images in follow-up after endovascular aneurysm repair (except immediately after the procedure), providing comparable diagnostic information with substantial dose savings.


Assuntos
Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
18.
Eur Heart J ; 30(3): 362-71, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19153177

RESUMO

AIMS: Although multislice computed tomography (MSCT) detects obstructive coronary artery disease (CAD) with high diagnostic accuracy, there is a paucity of long-term prognostic data. We sought to assess the incremental prognostic value of 64-slice CT in patients with suspected but no documented CAD. METHODS AND RESULTS: Coronary MSCT was performed on 227 individuals (61% men, mean age 54 +/- 12 years, 63% with intermediate pre-test probability) without documented CAD, referred for coronary evaluation. Coronary artery disease by MSCT was categorized as follows: none or mild CAD (<50%, n = 172), > or =50% in one vessel (n = 23), two vessels [or in the proximal left anterior descending (LAD), n = 12], and three vessels (or in two vessels including the proximal LAD or left main, n = 20). Baseline risk factors, length of follow-up, and major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), and coronary revascularization were recorded. Over a mean follow-up of 2.3 +/- 0.8 years, there were 18 MACE [including four hard events (one cardiac death and three MIs)]. Also, patients with one or more vessel obstructive CAD had increased hard events compared with those with less than one-vessel disease (log-rank statistic P-value 0.01). One or more vessel obstructive CAD was a significant predictor of MACE on univariable and multivariable Cox proportional survival analysis [hazard ratios 29.1 (6.7-126.6) and 9.82 (3.58-27.01), respectively, both P < 0.0001]. In 172 patients, with no or mild CAD, there was 99% freedom from MACE during follow-up. CONCLUSION: Multislice computed tomography-classified extent of CAD provides incremental prognostic information in patients with suspected but no documented CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Adulto , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/patologia , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Revascularização Miocárdica , Prognóstico , Tomografia Computadorizada por Raios X/métodos
19.
Med Phys ; 47(7): e881-e912, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32215937

RESUMO

In x-ray computed tomography (CT), materials with different elemental compositions can have identical CT number values, depending on the mass density of each material and the energy of the detected x-ray beam. Differentiating and classifying different tissue types and contrast agents can thus be extremely challenging. In multienergy CT, one or more additional attenuation measurements are obtained at a second, third or more energy. This allows the differentiation of at least two materials. Commercial dual-energy CT systems (only two energy measurements) are now available either using sequential acquisitions of low- and high-tube potential scans, fast tube-potential switching, beam filtration combined with spiral scanning, dual-source, or dual-layer detector approaches. The use of energy-resolving, photon-counting detectors is now being evaluated on research systems. Irrespective of the technological approach to data acquisition, all commercial multienergy CT systems circa 2020 provide dual-energy data. Material decomposition algorithms are then used to identify specific materials according to their effective atomic number and/or to quantitate mass density. These algorithms are applied to either projection or image data. Since 2006, a number of clinical applications have been developed for commercial release, including those that automatically (a) remove the calcium signal from bony anatomy and/or calcified plaque; (b) create iodine concentration maps from contrast-enhanced CT data and/or quantify absolute iodine concentration; (c) create virtual non-contrast-enhanced images from contrast-enhanced scans; (d) identify perfused blood volume in lung parenchyma or the myocardium; and (e) characterize materials according to their elemental compositions, which can allow in vivo differentiation between uric acid and non-uric acid urinary stones or uric acid (gout) or non-uric acid (calcium pyrophosphate) deposits in articulating joints and surrounding tissues. In this report, the underlying physical principles of multienergy CT are reviewed and each of the current technical approaches are described. In addition, current and evolving clinical applications are introduced. Finally, the impact of multienergy CT technology on patient radiation dose is summarized.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Imagens de Fantasmas , Fótons , Raios X
20.
Med Phys ; 46(11): 5216-5226, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31442300

RESUMO

PURPOSE: Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners incorporating novel design features. We aimed to compare radiation dose estimates from MC simulation to doses measured in physical anthropomorphic phantoms using metal-oxide semiconductor field-effect transistors (MOSFETs) in a 256-slice CT scanner. METHODS: Fifty MOSFETs were placed in organs within tissue-equivalent anthropomorphic adult and pediatric radiographic phantoms, which were scanned using a variety of chest, cardiac, abdomen, brain, and whole-body protocols on a 256-slice system. MC computations were performed on voxelized CT reconstructions of the phantoms using a highly parallel MC tool developed specifically for diagnostic X-ray energies and rapid computation. Doses were compared between MC estimates and physical measurements. RESULTS: The average ratio of MOSFET to MC dose in the in-field region was close to 1 (range, 0.96-1.12; mean ± SD, 1.01 ± 0.04), indicating outstanding agreement between measured and simulated doses. The difference between measured and simulated doses tended to increase with distance from the in-field region. The error in the MC simulations due to the limited number of simulated photons was less than 1%. The errors in the MOSFET dose determinations in the in-field region for a single scan were mainly due to the calibration method and were typically about 6% (8% if the error in the reading of the ionization chamber that was used for the MOSFET calibration was included). CONCLUSIONS: Radiation dose estimation using a highly parallelized MC method is strongly correlated with experimental measurements in physical adult and infant anthropomorphic phantoms for a wide range of scans performed on a 256-slice CT scanner. Incorporation into CT scanners of radiation-dose distribution estimation, employing the scanner's reconstructed images of the patient, may offer the potential for accurate patient-specific CT dosimetry.


Assuntos
Metais/química , Método de Monte Carlo , Óxidos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Transistores Eletrônicos , Adulto , Calibragem , Humanos , Radiometria , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa