1.
Masui ; 62(6): 710-3, 2013 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-23814999

RESUMO

A 70-year-old woman was scheduled to undergo surgery for removal of thyroid tumor under general anesthesia. A routine preoperative evaluation confirmed that the patient was stable with no signs of cyanosis and dyspnea. However, during pre-oxygenation as well as mechanical ventilation with 100% oxygen, she showed sustained low SpO2 values (i.e., 91%). Arterial blood gas analysis at FIO2 of 1.0 showed an oxygen partial pressure (PaO2) of 297 mmHg. Unexpectedly, the analysis revealed methemoglobinemia (MetHb concentration: 15%) causing a discrepancy between the low SpO2 and normal PaO2 values in this patient. Methemoglobinemia is an uncommon cause of cyanosis; however, anesthesiologists should be aware that some drugs used during perioperative period (e.g., local anesthetics) can cause methemoglobinemia. While our case was a mild one and the patient recovered with no complications, methemoglobinemia levels above 30% could cause tissue hypoxemia and, thereby, requiring a treatment with methylene blue or ascorbic acid.


Assuntos
Anestesia Geral , Metemoglobinemia/diagnóstico , Idoso , Feminino , Humanos , Oximetria , Oxigênio/análise , Neoplasias da Glândula Tireoide/cirurgia