Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Magn Reson Imaging ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39165139

RESUMO

BACKGROUND: Magnetic resonance elastography (MRE) can quantify tissue biomechanics noninvasively, including pathological hepatic states like metabolic dysfunction-associated steatohepatitis. PURPOSE: To compare the performance of 2D/3D-MRE using the gravitational (GT) transducer concept with the current commercial acoustic (AC) solution utilizing a 2D-MRE approach. Additionally, quality index markers (QIs) were proposed to identify image pixels with sufficient quality for reliably estimating tissue biomechanics. STUDY TYPE: Prospective. POPULATION: One hundred seventy participants with suspected or confirmed liver disease (median age, 57 years [interquartile range (IQR), 46-65]; 66 females), and 11 healthy volunteers (median age, 31 years [IQR, 27-34]; 5 females). FIELD STRENGTH/SEQUENCE: Participants were scanned twice at 1.5 T and 60 Hz vibration frequency: first, using AC-MRE (2D-MRE, spin-echo EPI sequence, 11 seconds breath-hold), and second, using GT-MRE (2D- and 3D-MRE, gradient-echo sequence, 14 seconds breath-hold). ASSESSMENT: Image analysis was performed by four independent radiologists and one biomedical engineer. Additionally, superimposed analytic plane shear waves of known wavelength and attenuation at fixed shear modulus were used to propose pertinent QIs. STATISTICAL TESTS: Spearman's correlation coefficient (r) was applied to assess the correlation between modalities. Interreader reproducibility was evaluated using Bland-Altman bias and reproducibility coefficients. P-values <0.05 were considered statistically significant. RESULTS: Liver stiffness quantified via GT-2D/3D correlated well with AC-2D (r ≥ 0.89 [95% CI: 0.85-0.92]) and histopathological grading (r ≥ 0.84 [95% CI: 0.72-0.91]), demonstrating excellent agreement in Bland-Altman plots and between readers (κ ≥ 0.86 [95% CI: 0.81-0.91]). However, GT-2D showed a bias in overestimating stiffness compared to GT-3D. Proposed QIs enabled the identification of pixels deviating beyond 10% from true stiffness based on a combination of total wave amplitude, temporal sinusoidal nonlinearity, and wave signal-to-noise ratio for GT-3D. CONCLUSION: GT-MRE represents an alternative to AC-MRE for noninvasive liver tissue characterization. Both GT-2D and 3D approaches correlated strongly with the established commercial approach, offering advanced capabilities in abdominal imaging compared to AC-MRE. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

2.
NMR Biomed ; 36(2): e4828, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36082477

RESUMO

Whole-body magnetic resonance imaging (MRI) has become increasingly popular in oncology. However, the long acquisition time might hamper its widespread application. We sought to assess and compare free-breathing sequences with conventional breath-hold examinations in whole-body MRI using an automated workflow process. This prospective study consisted of 20 volunteers and six patients with a variety of pathologies who had undergone whole-body 1.5-T MRI that included T1-weighted radial and Dixon volumetric interpolated breath-hold examination sequences. Free-breathing sequences were operated by using an automated user interface. Image quality, diagnostic confidence, and image noise were evaluated by two experienced radiologists. Additionally, signal-to-noise ratio was measured. Diagnostic performance for the overall detection of pathologies was assessed using the area under the receiver operating characteristics curve (AUC). Study participants were asked to rate their examination experiences in a satisfaction survey. MR free-breathing scans were rated as at least equivalent to conventional MR scans in more than 92% of cases, showing high overall diagnostic accuracy (95% [95% CI 92-100]) and performance (AUC 0.971, 95% CI 0.942-0.988; p < 0.0001) for the assessment of pathologies at simultaneously reduced examination times (25 ± 2 vs. 32 ± 3 min; p < 0.0001). Interrater agreement was excellent for both free-breathing (Ï° = 0.96 [95% CI 0.88-1.00]) and conventional scans (Ï° = 0.93 [95% CI 0.84-1.00]). Qualitative and quantitative assessment for image quality, image noise, and diagnostic confidence did not differ between the two types of MR image acquisition (all p > 0.05). Scores for patient satisfaction were significantly better for free-breathing compared with breath-hold examinations (p = 0.0145), including significant correlations for the grade of noise (r = 0.79, p < 0.0001), tightness (r = 0.71, p < 0.0001), and physical fatigue (r = 0.52, p = 0.0065). In summary, free-breathing whole-body MRI in tandem with an automated user interface yielded similar diagnostic performance at equivalent image quality and shorter acquisition times compared to conventional breath-hold sequences.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Imagem Corporal Total , Fluxo de Trabalho
3.
Eur J Clin Invest ; 53(12): e14075, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37571983

RESUMO

BACKGROUND: To investigate the potential of radiomic features and dual-source dual-energy CT (DECT) parameters in differentiating between benign and malignant mediastinal masses and predicting patient outcomes. METHODS: In this retrospective study, we analysed data from 90 patients (38 females, mean age 51 ± 25 years) with confirmed mediastinal masses who underwent contrast-enhanced DECT. Attenuation, radiomic features and DECT-derived imaging parameters were evaluated by two experienced readers. We performed analysis of variance (ANOVA) and Chi-square statistic tests for data comparison. Receiver operating characteristic curve analysis and Cox regression tests were used to differentiate between mediastinal masses. RESULTS: Of the 90 mediastinal masses, 49 (54%) were benign, including cases of thymic hyperplasia/thymic rebound (n = 10), mediastinitis (n = 16) and thymoma (n = 23). The remaining 41 (46%) lesions were classified as malignant, consisting of lymphoma (n = 28), mediastinal tumour (n = 4) and thymic carcinoma (n = 9). Significant differences were observed between benign and malignant mediastinal masses in all DECT-derived parameters (p ≤ .001) and 38 radiomic features (p ≤ .044) obtained from contrast-enhanced DECT. The combination of these methods achieved an area under the curve of .98 (95% CI, .893-1.000; p < .001) to differentiate between benign and malignant masses, with 100% sensitivity and 91% specificity. Throughout a follow-up of 1800 days, a multiparametric model incorporating radiomic features, DECT parameters and gender showed promising prognostic power in predicting all-cause mortality (c-index = .8 [95% CI, .702-.890], p < .001). CONCLUSIONS: A multiparametric approach combining radiomic features and DECT-derived imaging biomarkers allows for accurate and noninvasive differentiation between benign and malignant masses in the anterior mediastinum.


Assuntos
Linfoma , Neoplasias do Mediastino , Neoplasias do Timo , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/patologia , Linfoma/diagnóstico por imagem , Neoplasias do Mediastino/diagnóstico por imagem
4.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37409393

RESUMO

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio , Neoplasias , Humanos , Neoplasias/sangue , Neoplasias/complicações , Neoplasias/diagnóstico , Valor Preditivo dos Testes , Fatores de Risco , Tromboembolia Venosa/sangue , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevenção & controle , Bioensaio/normas , Sensibilidade e Especificidade
5.
Eur Radiol ; 32(4): 2168-2177, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820684

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. METHODS: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. RESULTS: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). CONCLUSIONS: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. KEY POINTS: • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


Assuntos
Deslocamento do Disco Intervertebral , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Medula Óssea , Edema , Feminino , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
6.
J Vasc Interv Radiol ; 31(2): 301-310, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31899107

RESUMO

PURPOSE: To examine predictive value of apparent diffusion coefficient (ADC) in diffusion-weighted imaging (DWI) for response of patients with primary and secondary lung neoplasms undergoing transpulmonary chemoembolization (TPCE) and transarterial chemoperfusion (TACP) treatment. MATERIALS AND METHODS: Thirty-one patients (mean age ± SD 64 ± 12.4 y) with 42 lung target lesions (13 primary and 29 secondary) underwent DWI and subsequent ADC analysis on a 1.5T MR imaging scanner before and 30.3 days ± 6.4 after first session of TPCE or TACP. After 3.1 treatment sessions ± 1.4 performed in 2- to 4-week intervals, morphologic response was analyzed by comparing tumor diameter and volume before and after treatment on unenhanced T1-weighted MR images. On a per-lesion basis, response was classified according to Response Evaluation Criteria In Solid Tumors. RESULTS: Threshold ADC increase of 20.7% indicated volume response with 88% sensitivity and 78% specificity (area under the curve [AUC] = 0.84). Differences between ADC changes in volume response groups were significant (P = .002). AUC for volume response predicted by ADC before treatment was 0.77. Median ADC before treatment and mean ADC change were 1.09 × 10-3 mm2/second and 0.36 × 10-3 mm2/second ± 0.23, 1.45 × 10-3 mm2/second and 0.14 × 10-3 mm2/second ± 0.16, and 1.30 × 10-3 mm2/second and 0.06 × 10-3 mm2/second ± 0.19 in partial response, stable disease, and progressive disease groups. In primary lung cancer lesions, strong negative correlation of ADC change with change in diameter (ρ = -.87, P < .001) and volume (ρ = -.66, P = .016) was found. In metastases, respective correlation coefficients were ρ = -.18 (P = .356) and ρ = -.35 (P = .061). CONCLUSIONS: ADC quantification shows considerable diagnostic value for predicting response and monitoring TPCE and TACP treatment of patients with primary and secondary lung neoplasms.


Assuntos
Quimioembolização Terapêutica , Quimioterapia do Câncer por Perfusão Regional , Imagem de Difusão por Ressonância Magnética , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomada de Decisão Clínica , Feminino , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/secundário , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
7.
Eur Radiol ; 29(12): 6539-6549, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31236701

RESUMO

OBJECTIVES: To evaluate the diagnostic value of Lipiodol distribution in angiography and CT to differentiate between hepatocellular carcinoma (HCC) and benign nodules of LI-RADS 3 and 4 lesions observed in MRI of liver cirrhosis. METHODS: This retrospective study included all patients with liver cirrhosis who had diagnosis of LI-RADS 3 or 4 lesions by MRI who underwent a Lipiodol-based angiography and post-interventional unenhanced CT- and liver biopsy. Two independent radiologists evaluated appearance, contrast enhancement, Lipiodol uptake in angiography, and morphological parameters (size, form, and density) of the lesions in unenhanced post-angiography CT. α-Fetoprotein (AFP) levels and pre-existing liver conditions were additionally taken into consideration. Differences between HCC lesions and benign nodules were analyzed. Sensitivity and specificity were calculated. P < 0.05 was considered as statistically significant. RESULTS: Of 60 patients (men, n = 42 [70.0%]; women, 18 [30.0%]; mean age, 61 ± 9.1 years) 36 (60.0%) had HCC and 24 (40.0%) benign nodules. Clear visibility in angiography (sensitivity [se], 100%; specificity [sp], 87.5%) with homogeneous or lacunar Lipiodol enhancement (se, 86.1%; sp, 100%) in consecutive CT can be diagnosed as HCC lesions in cirrhotic liver. Lesion form (p < 0.001), round or oval, and intense contrast (p < 0.001) are minor features which can facilitate the findings. Furthermore, patients with HCC showed a larger lesion size in CT (p = 0.026). CONCLUSION: Clearly detectable lesions in Lipiodol-based angiography and a homogeneous or lacunar enhancement in post-angiographic non-contrast CT allow for differentiation of intrahepatic lesions classified as LI-RADS 3 or 4 into benign vs. malign liver lesions with high sensitivity and specificity in patients with liver cirrhosis. Definite diagnosis may not require an additional biopsy. KEY POINTS: • Combination of clear visibility in Lipiodol-based angiography and homogeneous or lacunar enhancement in following native CT scan is HCC-defining. • In lesions classified with MRI as LI-RADS 3 or 4, evaluation based on Lipiodol angiography and following plain CT performed is highly sensitive and specific for the differentiation between HCC and benign nodules in a cirrhotic liver. • The results lead to an alternative pathway in the diagnosis of HCC in cirrhotic liver without the need of an additional liver biopsy.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/farmacocinética , Óleo Etiodado/farmacocinética , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia/métodos , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/patologia , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Eur Radiol Exp ; 8(1): 95, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39186171

RESUMO

BACKGROUND: We evaluated the role of dual-energy computed tomography (DECT)-based collagen maps in assessing thoracic disc degeneration. METHODS: We performed a retrospective analysis of patients who underwent DECT and magnetic resonance imaging (MRI) of the thoracic spine within a 2-week period from July 2019 to October 2022. Thoracic disc degeneration was classified by three blinded radiologists into three Pfirrmann categories: no/mild (grade 1-2), moderate (grade 3-4), and severe (grade 5). The DECT performance was determined using MRI as a reference standard. Interreader reliability was assessed using intraclass correlation coefficient (ICC). Five-point Likert scales were used to assess diagnostic confidence and image quality. RESULTS: In total, 612 intervertebral discs across 51 patients aged 68 ± 16 years (mean ± standard deviation), 28 males and 23 females, were assessed. MRI revealed 135 no/mildly degenerated discs (22.1%), 470 moderately degenerated discs (76.8%), and 7 severely degenerated discs (1.1%). DECT collagen maps achieved an overall accuracy of 1,483/1,838 (80.8%) for thoracic disc degeneration. Overall recall (sensitivity) was 331/405 (81.7%) for detecting no/mild degeneration, 1,134/1,410 (80.4%) for moderate degeneration, and 18/21 (85.7%) for severe degeneration. Interrater agreement was good (ICC = 0.89). Assessment of DECT-based collagen maps demonstrated high diagnostic confidence (median 4; interquartile range 3-4) and good image quality (median 4; interquartile range 4-4). CONCLUSION: DECT showed an overall 81% accuracy for disc degeneration by visualizing differences in the collagen content of thoracic discs. RELEVANCE STATEMENT: Utilizing DECT-based collagen maps to distinguish various stages of thoracic disc degeneration could be clinically relevant for early detection of disc-related conditions. This approach may be particularly beneficial when MRI is contraindicated. KEY POINTS: A total of 612 intervertebral discs across 51 patients were retrospectively assessed with DECT, using MRI as a reference standard. DECT-based collagen maps allowed thoracic disc degeneration assessment achieving an overall 81% accuracy with good interrater agreement (ICC = 0.89). DECT-based collagen maps could be a good alternative in the case of contraindications to MRI.


Assuntos
Colágeno , Degeneração do Disco Intervertebral , Imageamento por Ressonância Magnética , Vértebras Torácicas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Degeneração do Disco Intervertebral/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
9.
Acad Radiol ; 30(12): 3010-3021, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37105804

RESUMO

RATIONALE AND OBJECTIVES: To investigate the diagnostic value of radiomics features and dual-source dual-energy CT (DECT) based material decomposition in differentiating low-risk thymomas, high-risk thymomas, and thymic carcinomas. MATERIALS AND METHODS: This retrospective study included 32 patients (16 males, mean age 66 ± 14 years) with pathologically confirmed thymic masses who underwent contrast-enhanced DECT between 10/2014 and 01/2023. Two experienced readers evaluated all patients regarding conventional radiomics features, as well as DECT-based features, including attenuation (HU), iodine density (mg/mL), and fat fraction (%). Data comparisons were performed using analysis of variance and chi-square statistic tests. Receiver operating characteristic curve analysis and Cox-regression tests were used to discriminate between low-risk/high-risk thymomas and thymic carcinomas. RESULTS: Of the 32 thymic tumors, 12 (38%) were low-risk thymomas, 11 (34%) were high-risk thymomas, and 9 (28%) were thymic carcinomas. Values differed significantly between low-risk thymoma, high-risk thymoma, and thymic carcinoma regarding DECT-based features (p ≤ 0.023) and 30 radiomics features (p ≤ 0.037). The area under the curve to differentiate between low-risk/high-risk thymomas and thymic cancer was 0.998 (95% CI, 0.915-1.000; p < 0.001) for the combination of DECT imaging parameters and radiomics features, yielding a sensitivity of 100% and specificity of 96%. During a follow-up of 60 months (IQR, 35-60 months), the multiparametric approach including radiomics features, DECT parameters, and clinical parameters showed an excellent prognostic power to predict all-cause mortality (c-index = 0.978 [95% CI, 0.958-0.998], p = 0.003). CONCLUSION: A multiparametric approach including conventional radiomics features and DECT-based features facilitates accurate, non-invasive discrimination between low-risk/high-risk thymomas and thymic carcinomas.


Assuntos
Iodo , Timoma , Neoplasias do Timo , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Timoma/diagnóstico , Timoma/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/patologia , Prognóstico
10.
Cancer Imaging ; 23(1): 38, 2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37072856

RESUMO

BACKGROUND: The advent of next-generation computed tomography (CT)- and magnetic resonance imaging (MRI) opened many new perspectives in the evaluation of tumor characteristics. An increasing body of evidence suggests the incorporation of quantitative imaging biomarkers into clinical decision-making to provide mineable tissue information. The present study sought to evaluate the diagnostic and predictive value of a multiparametric approach involving radiomics texture analysis, dual-energy CT-derived iodine concentration (DECT-IC), and diffusion-weighted MRI (DWI) in participants with histologically proven pancreatic cancer. METHODS: In this study, a total of 143 participants (63 years ± 13, 48 females) who underwent third-generation dual-source DECT and DWI between November 2014 and October 2022 were included. Among these, 83 received a final diagnosis of pancreatic cancer, 20 had pancreatitis, and 40 had no evidence of pancreatic pathologies. Data comparisons were performed using chi-square statistic tests, one-way ANOVA, or two-tailed Student's t-test. For the assessment of the association of texture features with overall survival, receiver operating characteristics analysis and Cox regression tests were used. RESULTS: Malignant pancreatic tissue differed significantly from normal or inflamed tissue regarding radiomics features (overall P < .001, respectively) and iodine uptake (overall P < .001, respectively). The performance for the distinction of malignant from normal or inflamed pancreatic tissue ranged between an AUC of ≥ 0.995 (95% CI, 0.955-1.0; P < .001) for radiomics features, ≥ 0.852 (95% CI, 0.767-0.914; P < .001) for DECT-IC, and ≥ 0.690 (95% CI, 0.587-0.780; P = .01) for DWI, respectively. During a follow-up of 14 ± 12 months (range, 10-44 months), the multiparametric approach showed a moderate prognostic power to predict all-cause mortality (c-index = 0.778 [95% CI, 0.697-0.864], P = .01). CONCLUSIONS: Our reported multiparametric approach allowed for accurate discrimination of pancreatic cancer and revealed great potential to provide independent prognostic information on all-cause mortality.


Assuntos
Iodo , Neoplasias Pancreáticas , Feminino , Humanos , Imageamento por Ressonância Magnética , Prognóstico , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Retrospectivos
11.
Acad Radiol ; 29(6): 880-887, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34266738

RESUMO

PURPOSE: To assess the influence of intravenously injected contrast agent on bone mineral density (BMD) assessment in dual-source dual-energy CT. METHODS: This retrospective study included 1,031 patients (mean age, 53 ± 7 years; 519 women) who had undergone third-generation dual-source dual-energy CT in context of tumor staging between January 2019 and December 2019. Dedicated postprocessing software based on material decomposition was used for phantomless volumetric BMD assessment of trabecular bone of the lumbar spine. Volumetric trabecular BMD values derived from unenhanced and contrast-enhanced portal venous phase were compared by calculating correlation and agreement analyses using Pearson product-moment correlation, linear regression, and Bland-Altman plots. RESULTS: Mean BMD values were 115.53 ± 37.23 and 116.10 ± 37.78 mg/cm3 in unenhanced and contrast-enhanced dual-energy CT series, respectively. Values from contrast-enhanced portal venous phase differed not significantly from those of the unenhanced phase (p = 0.44) and showed high correlation (r = 0.971 [95% CI, 0.969-0.973]) with excellent agreement in Bland-Altman plots. Mean difference of the two phases was 0.61 mg/cm3 (95% limits of agreement, -17.14 and 18.36 mg/cm3). CONCLUSION: Portal venous phase dual-source dual-energy CT allows for accurate opportunistic BMD assessment of trabecular bone of the lumbar spine compared to unenhanced imaging. Therefore, dual-source CT may provide greater flexibility regarding BMD assessment in clinical routine and reduce radiation exposure by avoiding additional osteodensitometry examinations, as contrast-enhanced CT scans in context of tumor staging are increasingly performed in dual-energy mode.


Assuntos
Densidade Óssea , Meios de Contraste , Absorciometria de Fóton/métodos , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
12.
Acad Radiol ; 29(6): 861-870, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35346565

RESUMO

PURPOSE: To assess and correlate pulmonary involvement and outcome of SARS-CoV-2 pneumonia with the degree of coronary plaque burden based on the CAC-DRS classification (Coronary Artery Calcium Data and Reporting System). METHODS: This retrospective study included 142 patients with confirmed SARS-CoV-2 pneumonia (58 ± 16 years; 57 women) who underwent non-contrast CT between January 2020 and August 2021 and were followed up for 129 ± 72 days. One experienced blinded radiologist analyzed CT series for the presence and extent of calcified plaque burden according to the visual and quantitative HU-based CAC-DRS Score. Pulmonary involvement was automatically evaluated with a dedicated software prototype by another two experienced radiologists and expressed as Opacity Score. RESULTS: CAC-DRS Scores derived from visual and quantitative image evaluation correlated well with the Opacity Score (r=0.81, 95% CI 0.76-0.86, and r=0.83, 95% CI 0.77-0.89, respectively; p<0.0001) with higher correlation in severe than in mild stage SARS-CoV-2 pneumonia (p<0.0001). Combined, CAC-DRS and Opacity Scores revealed great potential to discriminate fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89-0.97), and the need for intensive care treatment (AUC 0.801, 95% CI 0.77-0.83). Visual and quantitative CAC-DRS Scores provided independent prognostic information on all-cause mortality (p=0.0016 and p<0.0001, respectively), both in univariate and multivariate analysis. CONCLUSIONS: Coronary plaque burden is strongly correlated to pulmonary involvement, adverse outcome, and death due to respiratory failure in patients with SARS-CoV-2 pneumonia, offering great potential to identify individuals at high risk.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Placa Aterosclerótica , Calcificação Vascular , Cálcio , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Pulmão , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , SARS-CoV-2 , Calcificação Vascular/diagnóstico por imagem
13.
Eur Radiol Exp ; 5(1): 43, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34608576

RESUMO

BACKGROUND: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). METHODS: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. RESULTS: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984-0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. CONCLUSIONS: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.


Assuntos
Densidade Óssea , Tomografia Computadorizada por Raios X , Absorciometria de Fóton , Vértebras Lombares/diagnóstico por imagem , Imagens de Fantasmas
14.
Acad Radiol ; 27(7): e168-e175, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31727567

RESUMO

RATIONALE AND OBJECTIVES: To compare dual-energy CT virtual monoenergetic images (VMI) and standard reconstructions for reliability of quantitative size measurements and diagnostic accuracy for the detection of colorectal liver metastases (CRLM). MATERIALS AND METHODS: We retrospectively included 98 patients (mean age, 61.1±11.5 years) with colorectal cancer, of whom 49 subjects had CRLM. All patients underwent a portal-venous phase dual-energy CT examination. Standard linearly-blended reformats and 40-keV VMI were reconstructed. For both reconstruction techniques, two blinded readers performed measurements of CRLM twice in a preset sequence. Three additional radiologists independently assessed all liver lesions in terms of dignity (benign vs. malignant). Sensitivity, specificity and diagnostic accuracy were calculated on a per-patient basis using MRI as reference standard. Readers scored the suitability for metric measurements and their diagnostic confidence using 5-point Likert scales. Inter-rater agreement was evaluated using intraclass correlation coefficient (ICC). RESULTS: Inter-rater agreement for lesion size measurements was higher for 40-keV VMI (ICC, 0.88) compared to standard linearly-blended series (ICC, 0.80). Sensitivity and diagnostic accuracy for the detection of CRLM were significantly higher for VMI at 40-keV compared to standard reconstructions (90.6% vs. 80.6%, and 89.1% vs. 81.3%; p < 0.001). Reader scores indicated that 40-keV VMI were more suitable for metric lesion measurements and provided greater diagnostic confidence compared to standard reformats (median, 5 vs. 3, and 5 vs. 4; both p < 0.001). CONCLUSION: Low-keV VMI reconstructions improve reliability of quantitative size measurements and diagnostic accuracy for the assessment of CRLM compared to standard linearly-blended images.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Idoso , Neoplasias Colorretais/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
15.
Cancer Immunol Immunother ; 58(10): 1557-63, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19184001

RESUMO

PURPOSE: To asses if laser-induced thermotherapy (LITT) induces a specific cytotoxic T cell response in patients treated with LITT for colorectal cancer liver metastases. METHODS: Eleven patients with liver metastases of colorectal cancer underwent LITT. Blood was sampled before and after LITT. Peripheral T cell activation was assessed by an interferon gamma (IFNg) secretion assay and flow cytometry. Test antigens were autologous liver and tumor lysate obtained from each patient by biopsy. T cells were stained for CD3/CD4/CD8 and IFNg to detect activated T cells. The ratio of IFNg positive to IFNg negative T cells was determined as the stimulation index (SI). To assess cytolytic activity, T cells were co-incubated with human colorectal cancer cells (CaCo) and cytosolic adenylate kinase release was measured by a luciferase assay. RESULTS: IFNg secretion assay: before LITT SI was 12.73 (+/-4.83) for CD3+, 4.36 (+/-3.32) for CD4+ and 3.64 (+/-1.77) for CD8+ T cells against autologous tumor tissue. Four weeks after LITT SI had increased to 92.09 (+/-12.04) for CD3+ (P < 0.001), 42.92 (+/-16.68) for CD4+ (P < 0.001) and 47.54 (+/-15.68) for CD8+ T cells (P < 0.001) against autologous tumor tissue. No increased SI was observed with normal liver tissue at any time point. Cytotoxicity assay: before LITT activity against the respective cancer cells was low, with RLU = 1,493 (+/-1,954.68), whereas after LITT cytolytic activity had increased to RLU = 7,260 [+/-3,929.76 (P < 0.001)]. CONCLUSION: Patients with liver metastases of colorectal cancer show a tumor-specific cytotoxic T cell stimulation and a significantly increased cytolytic activity of CD3+, CD4+ and CD8+ T cells after LITT against an allogenic tumor (CaCo cell line).


Assuntos
Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Neoplasias Colorretais/imunologia , Hipertermia Induzida , Neoplasias Hepáticas/imunologia , Ativação Linfocitária/fisiologia , Linfócitos T Citotóxicos/imunologia , Idoso , Idoso de 80 Anos ou mais , Linfócitos T CD4-Positivos/patologia , Linfócitos T CD8-Positivos/patologia , Ablação por Cateter , Neoplasias Colorretais/patologia , Feminino , Citometria de Fluxo , Humanos , Interferon gama/metabolismo , Lasers , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
Radiology ; 251(3): 788-95, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19336670

RESUMO

PURPOSE: To evaluate the effect of preprocedural prediction of the best tube angle obliquity for visualization of the uterine artery origin by using three-dimensional (3D)-reconstructed contrast material-enhanced magnetic resonance (MR) angiography on the radiation dose, fluoroscopy time, and contrast medium volume during uterine artery embolization (UAE). MATERIALS AND METHODS: The study was approved by the institutional review board. Informed consent was obtained. The prospective study included 20 consecutive prospective patients (age range, 37-56 years) for whom preprocedural prediction of the best tube angle obliquity was determined by using 3D-reconstructed contrast-enhanced MR angiography; the best tube angle obliquity was provided to the interventionist. Three-dimensional reconstruction was performed by using an application of the angiographic unit. The radiation dose, fluoroscopy time, and contrast medium volume for those patients were compared with those data in 20 retrospectively assessed control patients (age range, 39-56 years) from the prior 20 procedures performed by the same interventionist. RESULTS: Tube angle prediction resulted in a significant reduction in the radiation dose utilized (P < .001), fluoroscopy time (P = .002), and contrast medium volume (P < .001) for the sample patients compared with those for the control patients. Overall radiation dose was reduced from a mean of 11 044 microGy per square meter to a mean of 4172.5 microGy per square meter. Fluoroscopy time was reduced from a mean of 15 minutes 30 seconds to 8 minutes 49 seconds. Contrast medium volume was reduced from a mean of 135 mL to 75 mL. CONCLUSION: Preprocedural prediction of the best tube angle obliquity for visualization of the origin of the uterine artery by using 3D-reconstructed contrast-enhanced MR angiography results in significant reductions in radiation dose, fluoroscopy time, and contrast medium volume during UAE.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Embolização da Artéria Uterina , Adulto , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
17.
J Vasc Interv Radiol ; 19(11): 1569-75, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18824376

RESUMO

PURPOSE: To evaluate the feasibility of three-dimensional (3D) reconstructed contrast-enhanced (CE) magnetic resonance (MR) angiography in mapping the pelvic arteries in women before uterine artery embolization (UAE). MATERIALS AND METHODS: CE MR angiography studies before UAE in 49 women (age range, 38-57 years; mean, 47.04 y +/- 4.7 [SD]) who underwent UAE for uterine leiomyomas between February 2005 and February 2007 were retrospectively evaluated by two radiologists in consensus. Studies were performed on a 1.5-T MR unit with a 3D fast low-angle shot sequence in the coronal direction. Reconstruction was performed with 3D computed tomographic angiography reconstruction software. RESULTS: In the current study, 98 internal iliac arteries (IIAs) from 49 women were studied. The superior and inferior gluteal arteries were visualized in all cases (N = 98; 100%), the lateral sacral artery in 86 cases (88%), the iliolumbar artery in 84 (86%), the obturator artery in 81 (83%), the internal pudendal artery in 96 (98%), and the uterine artery in 95 (97%). The superior vesical and middle rectal arteries were seen in 21 (21%) and 11 (11%) cases, respectively. The mean length of the uterine artery was 12.56 cm (range, 4.6-22.2 cm), and it showed the longest traceable length among all branches. The uterine artery showed five patterns of origin. The superior gluteal artery showed constant origin from the posterior division of the IIA, whereas the iliolumbar and obturator arteries showed the most variations in origin. CONCLUSIONS: Three-dimensional reconstructed CE MR angiography can detect most branches of the IIA in addition to their point of origin. Therefore, it can be used as a mapping tool of the pelvic arterial tree before UAE.


Assuntos
Gadolínio DTPA , Artéria Ilíaca/patologia , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Embolização da Artéria Uterina/métodos , Adulto , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Rofo ; 190(6): 513-520, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29763951

RESUMO

PURPOSE: This study was carried out to investigate the impact of abdominal dynamic four-dimensional CT angiography (4D-CTA) for guiding transarterial chemoembolization (TACE) on the amount of contrast material used, operator radiation exposure, catheter consumption, and diagnostic confidence. MATERIALS AND METHODS: Written consent was waived for this IRB-approved retrospective study. 29 patients (20 men; mean age: 65.7 ±â€Š11.5 years) with malignant liver lesions underwent 4D-CTA, prior to initial TACE. Time-resolved volume-rendering technique (VRT), maximum-intensity projection (MIP), and multiplanar reconstruction (MPR) series were reconstructed, enabling a direct selective catheterization of the tumor-supplying artery without prior conventional digital subtraction angiography (DSA). 29 patients (16 men; mean age: 69.4 ±â€Š13.9) who underwent traditional TACE served as the control group. The amount of administered contrast media, operator radiation exposure, and catheter consumption during TACE were compared. Two radiologists assessed diagnostic confidence in the exclusion of portal vein thrombosis. RESULTS: 4D-CTA TACE resulted in a significant reduction in the amount of contrast media used, compared to traditional TACE (-61.0 ml/ -66.3 % intra-arterial, -12.8 ml/ -13.8 % overall; P < 0.001). The dose-area product indicating operator radiation exposure during intervention was reduced by 50.5 % (P < 0.001), and 0.7 fewer catheters on average were used (P = 0.063), while 4D-CTA data was available to guide TACE. Diagnostic confidence in the exclusion of portal vein thrombosis was significantly enhanced by 4D-CTA, compared to traditional DSA images (scores, 3.9 and 2.4, respectively; P < 0.001). CONCLUSION: Dynamic 4D-CTA enables TACE with a substantially reduced amount of contrast material, decreases operator radiation exposure, and increases diagnostic confidence in the exclusion of portal vein thrombosis. KEY POINTS: · 4D-CTA prior to TACE decreases the amount of utilized contrast material.. · The intra-arterial fraction of contrast media can be reduced by two-thirds.. · The risk of CIN may be decreased by means of 4D-CTA TACE.. · Operator radiation exposure is lower using 4D-CTA for guiding TACE.. · 4D-CTA portography allows for a higher diagnostic confidence than conventional DSA images.. CITATION FORMAT: · Albrecht MH, Vogl TJ, Wichmann JL et al. Dynamic 4D-CT Angiography for Guiding Transarterial Chemoembolization: Impact on the Reduction of Contrast Material, Operator Radiation Exposure, Catheter Consumption, and Diagnostic Confidence. Fortschr Röntgenstr 2018; 190: 513 - 520.


Assuntos
Catéteres , Quimioembolização Terapêutica , Tomografia Computadorizada Quadridimensional , Exposição Ocupacional/prevenção & controle , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/irrigação sanguínea , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/terapia , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Colangiocarcinoma/irrigação sanguínea , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/terapia , Estudos de Coortes , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Falha de Equipamento , Feminino , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ácidos Tri-Iodobenzoicos/administração & dosagem
19.
Eur Radiol ; 16(10): 2317-25, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16622690

RESUMO

The aim of the study was to compare prospectively magnetic resonance cholangiography (MRC) and magnetic resonance imaging (MRI) with endoscopic retrograde cholangiography (ERC) in the diagnosis and staging of Klatskin tumours of the biliary tree (hilar cholangiocarcinomas). Forty-six patients with suspected Klatskin tumours of the biliary tract underwent MRI and heavily T2-weighted, non-breathhold, respiratory-triggered fast spin-echo MRC. Forty-two patients underwent ERC within 24 h; in four patients, ERC was not feasible, and percutaneous trans-hepatic cholangiography (PTC) was carried out instead. Two independent investigators evaluated imaging results for the presence of tumour, bile duct dilatation, and stenosis. Clinical and histopathological correlation revealed Klatskin tumours in 33 patients. MRI revealed a slightly hyperintense signal of infiltrated bile ducts in T2-weighted fast spin-echo sequences. The malignant lesion was regularly visualized as a hypointense area in T1-weighted gradient-echo sequences with substantial contrast enhancement along the involved bile duct walls. MRC revealed the location and extension of the tumour in 31 of 33 cases correctly (sensitivity 94%, specificity 100%, diagnostic accuracy 95%). In 27 of 31 cases, ERC enabled accurate staging and diagnosis of Klatskin tumours with a sensitivity of 87%. ERC and PTC combined yielded a sensitivity of 84% and a specificity of 97%. Tumours were grouped according to the Bismuth classification, with MRC allowing correct identification of type I tumour in seven patients, type II tumour in four patients, type III tumour in 12 patients, and type IV tumour in ten patients. MRC provided superior visualization of completely obstructed peripheral systems. MRC in combination with MRI is a reliable non-invasive diagnostic method for the pre-therapeutic staging of Klatskin tumours.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico , Colangiopancreatografia Retrógrada Endoscópica , Colangiopancreatografia por Ressonância Magnética , Ducto Hepático Comum , Tumor de Klatskin/diagnóstico , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Tumor de Klatskin/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
20.
Eur Radiol ; 15 Suppl 5: E78-90, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18637234

RESUMO

Multidetector computed tomography (MDCT), is the latest breakthrough in CT technology. Thin sections can now be acquired a routine basis in a single-breathhold with 3D-isotropic reconstructions. This results in improved lesion detection of benign as well as malignant abdominal tumours. The ability to scan through the entire abdomen in seconds allows multiphasic acquisitions. Therefore precise timing and optimized contrast is of great importance. Hypervascularized solid abdominal tumours are best depicted within the time generally regarded as the arterial dominant phase in MDCT, conversely hypovascular lesions are best depicted during venous phase imaging. The acquisition of an early arterial phase provides precise documentation of the arterial vascular system and should be obtained in preoperative abdominal imaging. Three clear separate circulatory phases enable best results in the pretherapeutic work-up of abdominal patients. Regarding follow-up oncologic work-up in colorectal metastatic disease a venous dominant phase might be the optimal protocol. Regarding contrast optimization, the traditional concept of imaging, where the injection duration equals the scanning duration cannot be used without modifications. To ensure adequate vessel opacification as well as soft tissue imaging with fast MDCT acquisitions, the iodine administration rate needs to be increased. This can be achieved either by an increase of injection flow rate or -more conveniently- by using a higher iodine concentration of the contrast medium. Especially for hypervascular tumours, e.g. HCC, a considerably to far higher contrasts can be achieved using higher concentrated contrast material. The overall improvement in precise timing and better visibility enable a comprehensive approach to abdominal imaging in MDCT.


Assuntos
Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Meios de Contraste , Humanos , Imageamento Tridimensional , Hepatopatias/diagnóstico por imagem , Pancreatopatias/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa